Bone remodeling after total hip arthroplasty with a short stemmed metaphyseal loading implant: Finite element analysis validated by a prospective DEXA investigation
Description
AbstractIn total hip arthroplasty (THA), short stemmed cementless implants are used because they are thought to stimulate physiological bone remodeling and reduce stress shielding. We performed a numerical investigation on bone remodeling after implantation of a specific short stemmed implant using finite element analysis (FEA). Overall bone mass loss was 2.8% in the entire femur. Bone mass decrease was mostly found in the proximal part of the calcar and in the greater trochanter due to the vast cross section of the implant, probably leading to stress shielding. In the diaphysis, no change in the apparent bone density was proven. The assumptions made agreed well with bone remodeling data from THA recipients who underwent dual‐energy X‐ray absorptiometry. However, the clinical investigation revealed a bone mass increase in the minor trochanter region that was less pronounced in the FEA. Further comparisons to other stem designs must be done to verify if the relative advantages of the investigated implant can be accepted. © 2012 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 30:1822–1829, 2012
Additional details
Identifiers
- OpenAlex
- W2063902806
- PMID
- 22513505
- URL
- https://onlinelibrary.wiley.com/doi/10.1002/jor.22120
Funding
Dates
- Issued
-
April 18, 2012
References
- https://doi.org/10.1302/0301-620x.82b7.10420 https://doi.org/10.1302/0301-620x.82b7.10420
- HUISKES, R., WEINANS, H., & RIETBERGEN, B. V. (1992). The Relationship Between Stress Shielding and Bone Resorption Around Total Hip Stems and the Effects of Flexible Materials. Clinical Orthopaedics and Related Research, 274, 124???134. https://doi.org/10.1097/00003086-199201000-00014
- Falez, F., Casella, F., Panegrossi, G., Favetti, F., & Barresi, C. (2008). Perspectives on metaphyseal conservative stems. Journal of Orthopaedics and Traumatology, 9(1), 49–54. https://doi.org/10.1007/s10195-008-0105-4
- Albanese, C. V., Rendine, M., De Palma, F., Impagliazzo, . a ., Falez, F., Postacchini, F., Villani, C., Passariello, R., & Santori, F. S. (2006). Bone remodelling in THA: A comparative DXA scan study between conventional implants and a new stemless femoral component. A preliminary report. Hip International, 16(Suppl. 3), 9–15. https://doi.org/10.5301/hip.2009.4849
- Panisello, J., Herrero, L., Herrera, A., Canales, V., Martinez, A., & Cuenca, J. (2006). Bone Remodelling after Total Hip Arthroplasty Using an Uncemented Anatomic Femoral Stem: A Three-Year Prospective Study Using Bone Densitometry. Journal of Orthopaedic Surgery, 14(1), 32–37. https://doi.org/10.1177/230949900601400108
- Brodner, W., Bitzan, P., Lomoschitz, F., Krepler, P., Jankovsky, R., Lehr, S., Kainberger, F., & Gottsauner-Wolf, F. (2004). Changes in bone mineral density in the proximal femur after cementless total hip arthroplasty. The Journal of Bone and Joint Surgery. British Volume, 86-B(1), 20–26. https://doi.org/10.1302/0301-620x.86b1.14637
- Modular short‐stem prosthesis in total hip arthroplasty: implant positioning and the influence of navigation
- Initial experience with short Metha stem implantation. 4
- Lerch, M., von der Haar-Tran, A., Windhagen, H., Behrens, B. A., Wefstaedt, P., & Stukenborg-Colsman, C. M. (2011). Bone remodelling around the Metha short stem in total hip arthroplasty: a prospective dual-energy X-ray absorptiometry study. International Orthopaedics, 36(3), 533–538. https://doi.org/10.1007/s00264-011-1361-0
- Behrens, B.-A., Nolte, I., Wefstaedt, P., Stukenborg-Colsman, C., & Bouguecha, A. (2009). Numerical investigations on the strain-adaptive bone remodelling in the periprosthetic femur: Influence of the boundary conditions. BioMedical Engineering OnLine, 8(1). https://doi.org/10.1186/1475-925x-8-7
- Rho, J. Y., Hobatho, M. C., & Ashman, R. B. (1995). Relations of mechanical properties to density and CT numbers in human bone. Medical Engineering & Physics, 17(5), 347–355. https://doi.org/10.1016/1350-4533(95)97314-f
- Speirs, A. D., Heller, M. O., Duda, G. N., & Taylor, W. R. (2007). Physiologically based boundary conditions in finite element modelling. Journal of Biomechanics, 40(10), 2318–2323. https://doi.org/10.1016/j.jbiomech.2006.10.038
- Morlock, M., Schneider, E., Bluhm, A., Vollmer, M., Bergmann, G., Müller, V., & Honl, M. (2001). Duration and frequency of every day activities in total hip patients. Journal of Biomechanics, 34(7), 873–881. https://doi.org/10.1016/s0021-9290(01)00035-5
- Bitsakos, C., Kerner, J., Fisher, I., & Amis, A. A. (2005). The effect of muscle loading on the simulation of bone remodelling in the proximal femur. Journal of Biomechanics, 38(1), 133–139. https://doi.org/10.1016/j.jbiomech.2004.03.005
- Duda, G. N., Heller, M., Albinger, J., Schulz, O., Schneider, E., & Claes, L. (1998). Influence of muscle forces on femoral strain distribution. Journal of Biomechanics, 31(9), 841–846. https://doi.org/10.1016/s0021-9290(98)00080-3
- Heller, M. O., Bergmann, G., Kassi, J.-P., Claes, L., Haas, N. P., & Duda, G. N. (2005). Determination of muscle loading at the hip joint for use in pre-clinical testing. Journal of Biomechanics, 38(5), 1155–1163. https://doi.org/10.1016/j.jbiomech.2004.05.022
- Bergmann, G., Deuretzbacher, G., Heller, M., Graichen, F., Rohlmann, A., Strauss, J., & Duda, G. N. (2001). Hip contact forces and gait patterns from routine activities. Journal of Biomechanics, 34(7), 859–871. https://doi.org/10.1016/s0021-9290(01)00040-9
- Duda, G. N., Schneider, E., & Chao, E. Y. S. (1997). Internal forces and moments in the femur during walking. Journal of Biomechanics, 30(9), 933–941. https://doi.org/10.1016/s0021-9290(97)00057-2
- Behrens, B.-A., Stukenborg-Colsman, C., Nolte, I., Wefstaedt, P., & Bouguecha, A. (2009). Femoral Load Change and Caused Bone Remodeling after Hip Arthroplasty. In IFMBE Proceedings (pp. 77–80). Springer Berlin Heidelberg. https://doi.org/10.1007/978-3-642-03882-2_20
- Speirs, A. D., Heller, M. O., Taylor, W. R., Duda, G. N., & Perka, C. (2007). Influence of changes in stem positioning on femoral loading after THR using a short-stemmed hip implant. Clinical Biomechanics, 22(4), 431–439. https://doi.org/10.1016/j.clinbiomech.2006.12.003
- Roth, A., Richartz, G., Sander, K., Sachse, A., Fuhrmann, R., Wagner, A., & Venbrocks, R.-A. (2005). Verlauf der periprothetischen Knochendichte nach Hüfttotalendoprothesenimplantation: Abhängigkeit von Prothesentyp und knöcherner Ausgangssituation. Der Orthopäde, 34(4), 334–344. https://doi.org/10.1007/s00132-005-0773-1
- https://doi.org/10.1302/0301-620x.82b7.9791 https://doi.org/10.1302/0301-620x.82b7.9791
- Mortimer, E. S., Rosenthall, L., Paterson, I., & Bobyn, J. D. (1996). Effect of Rotation on Periprosthetic Bone Mineral Measurements in a Hip Phantom. Clinical Orthopaedics and Related Research, 324, 269–274. https://doi.org/10.1097/00003086-199603000-00033
- Lengsfeld, M., Günther, D., Pressel, T., Leppek, R., Schmitt, J., & Griss, P. (2002). Validation data for periprosthetic bone remodelling theories. Journal of Biomechanics, 35(12), 1553–1564. https://doi.org/10.1016/s0021-9290(02)00187-2
- Aldinger, P. R., Sabo, D., Pritsch, M., Thomsen, M., Mau, H., Ewerbeck, V., & Breusch, S. J. (2003). Pattern of Periprosthetic Bone Remodeling Around Stable Uncemented Tapered Hip Stems: A prospective 84-month follow-up study and a Median 156-month Cross-Sectional Study with DXA. Calcified Tissue International, 73(2), 115–121. https://doi.org/10.1007/s00223-002-2036-z
1–25 of 34
Citations
- https://doi.org/10.1186/s12891-026-10138-y
- https://doi.org/10.3390/osteology6010002
- Alesi, D., Zinno, R., Scoppolini Massini, M., Barone, G., Valente, D., Pinelli, E., Zaffagnini, S., Mirulla, A. I., & Bragonzoni, L. (2025). Variations in bone mineral density after joint replacement: A systematic review examining different anatomical regions, fixation techniques and implant design. Journal of Experimental Orthopaedics, 12(2). https://doi.org/10.1002/jeo2.70187
- Evola, F. R., Caldaria, A., Costarella, L., D’Amico, A. G., D’Agata, V., Vecchio, M., & Sessa, G. (2025). Comparative study of fitmore and CLS stems in total hip arthroplasty: midterm clinical and radiographic outcomes. MUSCULOSKELETAL SURGERY, 109(3), 357–365. https://doi.org/10.1007/s12306-025-00885-x
- https://doi.org/10.1109/tbme.2025.3568877
- Ramesh, A., Di Laura, A., De Angelis, S., Henckel, J., & Hart, A. (2024). Bone remodeling after revision total hip arthroplasty for large acetabular defects. Journal of Orthopaedic Research, 42(12), 2784–2795. https://doi.org/10.1002/jor.25936
- Rana, M., Karmakar, S. K., Verdonschot, N., & Roychowdhury, A. (2024). Prediction of micro-scale bone adaptation of human trabecular bone under different implanted conditions. Journal of the Mechanical Behavior of Biomedical Materials, 160, 106747. https://doi.org/10.1016/j.jmbbm.2024.106747
- Bahrami, M., Khonakdar, H., Moghaddam, A., Mahand, S. N., Bambizi, P. E., Kruppke, B., & Khonakdar, H. A. (2024). A review of the current status and future prospects of the bone remodeling process: Biological and mathematical perspectives. Progress in Biophysics and Molecular Biology, 194, 16–33. https://doi.org/10.1016/j.pbiomolbio.2024.10.001
- Afghanyar, Y., Kutzner, K. P., Pfeil, J., Drees, P., Rehbein, P., & Dargel, J. (2024). Cementless Short Stems in Total Hip Arthroplasty: Chances and Limits. The Journal of Hip Surgery, 08(03), 125–133. https://doi.org/10.1055/s-0044-1800908
- https://doi.org/10.1186/s13018-024-04944-0
- https://doi.org/10.2139/ssrn.4837891
- Nelson, J. T., Zheng, H., Hallstrom, B. R., Hughes, R. E., Mont, M. A., & Masini, M. A. (2023). Are Short Stems Associated With Higher Fracture Rates and Early Revision Rates in Primary Total Hip Arthroplasty? A Noninferiority Analysis. The Journal of Arthroplasty, 38(7), 1287–1294.e2. https://doi.org/10.1016/j.arth.2023.01.008
- https://doi.org/10.3390/diagnostics13213334
- Sugano, N., Hamada, H., Uemura, K., Takashima, K., & Nakahara, I. (2022). Numerical analysis evaluation of artificial joints. Journal of Artificial Organs, 25(3), 185–190. https://doi.org/10.1007/s10047-022-01345-0
- Afghanyar, Y., Kutzner, K. P., Pfeil, J., Drees, P., Rehbein, P., & Dargel, J. (2022). Zementfreie Kurzschaftprothesen in der Hüftendoprothetik: Möglichkeiten und Limits. Zeitschrift für Orthopädie und Unfallchirurgie, 161(04), 396–404. https://doi.org/10.1055/a-1678-7684
- https://doi.org/10.1080/10255842.2022.2064712
- Chen, X., Myers, C. A., Clary, C. W., DeWall, R. J., Fritz, B., Blauth, M., & Rullkoetter, P. J. (2021). Development of axial compression and combined axial compression and torque loading configurations to reproduce strain in the implanted femur during activities of daily living. Journal of Biomechanics, 120, 110363. https://doi.org/10.1016/j.jbiomech.2021.110363
- Ghaziani, A. O., Soheilifard, R., & Kowsar, S. (2021). The effect of functionally graded materials on bone remodeling around osseointegrated trans-femoral prostheses. Journal of the Mechanical Behavior of Biomedical Materials, 118, 104426. https://doi.org/10.1016/j.jmbbm.2021.104426
- https://doi.org/10.1186/s40634-021-00388-1
- https://doi.org/10.4286/jjmi.91.373
- Fonseca Ulloa, C. A., Seeger, A., Ishaque, B. A., Ahmed, G. A., Rickert, M., & Jahnke, A. (2020). How do the geometries of the broach handles relate to the distribution of force and moments in a femoral model?. Medical Engineering & Physics, 86(1), 122–127. https://doi.org/10.1016/j.medengphy.2020.11.001
- https://doi.org/10.1186/s13018-020-01675-w
- https://doi.org/10.1186/s13018-020-02027-4
- https://doi.org/10.2106/jbjs.20.00351
- Bouguecha, A., Behrens, B.-A., & Lerch, M. (2019). Femoral Postoperative Bone Adaptation – Numerical Calculation and Clinical Validation with DEXA Investigations. In Lecture Notes in Mechanical Engineering (pp. 3–15). Springer International Publishing. https://doi.org/10.1007/978-3-030-19781-0_1
1–25 of 63