The potential use of scout views as an adjunct tool in CT-guided intervention
Description
Abstract The objective of this study was to evaluate the use of scout views as an adjunct tool in CT-guided intervention. Therefore, different devices used for interventional procedures were assigned to three different groups and placed onto an Alderson phantom. Different body diameters were simulated by adding PMMA/aluminum plates. Multiple scout views (ap) were acquired using a standard CT-scanner with different scan parameters. The visibility of the devices was semi-quantitatively scored by three readers. The interrater reliability was calculated using the intraclass correlation coefficient (ICC). The detectability of the 11 different interventional devices was calculated depending on tube potential, tube current–time product, and the thickness of the additional tissue equivalent. Statistical significance was evaluated using Wilcoxon signed-rank test (with Pratt modification) and the Mann–Whitney-U test, respectively. The ICC over all measurements for the three readers as well as the ICC for the three different devices groups was regarded excellent (> 0.9). The device detectability was significantly different for the different additional tissue thicknesses as well as for the three device groups. Material detectability over all readers improved with higher doses. Defining a median visibility of 3 ("good") or 4 ("very good") as a cut-off value for clinical routine use, we consider a combination of ≥ 80kVp / ≥ 60 mAs or ≥ 90 kVp / ≥ 40 mAs as reasonable scan parameters in normal and overweight patients in our CT setup. In conclusion, CT scout views have a potential use as an additional tool in CT-guided-intervention by enabling fluoroscopy-like planar imaging that may help to visualize dynamic events such as contrast injection or guidewire manipulation.
Additional details
Identifiers
- OpenAlex
- W4414705332
- PMID
- 41034562
- URL
- https://www.nature.com/articles/s41598-025-22040-z
Funding
- Medizinische Hochschule Hannover (MHH)
Dates
- Issued
-
October 1, 2025
References
- Furlow, B. CT-Guided interventional radiology. Radiol. Technol. 90, 581–597 (2019).
- Sarti, M., Brehmer, W. P., & Gay, S. B. (2012). Low-Dose Techniques in CT-guided Interventions. RadioGraphics, 32(4), 1109–1119. https://doi.org/10.1148/rg.324115072
- Prosch, H., Stadler, A., Schilling, M., Bürklin, S., Eisenhuber, E., Schober, E., & Mostbeck, G. (2012). CT fluoroscopy-guided vs. multislice CT biopsy mode-guided lung biopsies: Accuracy, complications and radiation dose. European Journal of Radiology, 81(5), 1029–1033. https://doi.org/10.1016/j.ejrad.2011.01.064
- Fukushima, Y., Nakamura, J., Seki, Y., Ando, M., Miyazaki, M., & Tsushima, Y. (2021). Patients' radiation dose in computed tomography-fluoroscopy-guided percutaneous cryoablation for small renal tumors. European Journal of Radiology, 144, 109972. https://doi.org/10.1016/j.ejrad.2021.109972
- Floridi, C., Cellina, M., Irmici, G., Bruno, A., Rossini, N., Borgheresi, A., Agostini, A., Bruno, F., Arrigoni, F., Arrichiello, A., Candelari, R., Barile, A., Carrafiello, G., & Giovagnoni, A. (2022). Precision Imaging Guidance in the Era of Precision Oncology: An Update of Imaging Tools for Interventional Procedures. Journal of Clinical Medicine, 11(14), 4028. https://doi.org/10.3390/jcm11144028
- Sommer, C. M., Huber, J., Radeleff, B. A., Hosch, W., Stampfl, U., Loenard, B. M., Hallscheidt, P., Haferkamp, A., Kauczor, H. U., & Richter, G. M. (2011). Combined CT- and fluoroscopy-guided nephrostomy in patients with non-obstructive uropathy due to urine leaks in cases of failed ultrasound-guided procedures. European Journal of Radiology, 80(3), 686–691. https://doi.org/10.1016/j.ejrad.2010.09.035
- Erinjeri, J. P., Doustaly, R., Avignon, G., Bendet, A., Petre, E. N., Ziv, E., Yarmohammadi, H., & Solomon, S. B. (2020). Utilization of integrated angiography-CT interventional radiology suites at a tertiary cancer center. BMC Medical Imaging, 20(1). https://doi.org/10.1186/s12880-020-00515-x
- Pfaff, J., Schönenberger, S., Herweh, C., Pham, M., Nagel, S., Ringleb, P. A., Heiland, S., Bendszus, M., & Möhlenbruch, M. A. (2017). Influence of a combined CT/C-arm system on periprocedural workflow and procedure times in mechanical thrombectomy. European Radiology, 27(9), 3966–3972. https://doi.org/10.1007/s00330-017-4762-7
- Wada, D., Nakamori, Y., Kanayama, S., Maruyama, S., Kawada, M., Iwamura, H., Hayakawa, K., Saito, F., & Kuwagata, Y. (2018). First installation of a dual-room IVR-CT system in the emergency room. Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine, 26(1). https://doi.org/10.1186/s13049-018-0484-3
- O'Neill, S., Kavanagh, R. G., Carey, B. W., Moore, N., Maher, M., & O'Connor, O. J. (2018). Using body mass index to estimate individualised patient radiation dose in abdominal computed tomography. European Radiology Experimental, 2(1). https://doi.org/10.1186/s41747-018-0070-5
- McCollough, C., Cody, D., Edyvean, S., Geise, R., Gould, B., Keat, N., Huda, W., Judy, P., Kalender, W., McNitt-Gray, M., Morin, R., Payne, T., Stern, S., & Rothenberg, L. (2008). The Measurement, Reporting, and Management of Radiation Dose in CT. In American Association of Physicists in Medicine. AAPM. https://doi.org/10.37206/97
- Koo, T. K., & Li, M. Y. (2016). A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research. Journal of Chiropractic Medicine, 15(2), 155–163. https://doi.org/10.1016/j.jcm.2016.02.012
- Becker, L. S., Ringe, K. I., Dewald, C. L. A., Canstein, C., Hinrichs, J. B., Wacker, F. K., & Meyer, B. C. (2023). Fully Integrated Laser Guidance for CT-Based Punctures: A Study in Phantoms and Patients. Journal of Vascular and Interventional Radiology, 34(1), 130–138. https://doi.org/10.1016/j.jvir.2022.09.014
- Ringe, K. I., Pöhler, G. H., Rabeh, H., & Wacker, F. (2021). Electromagnetic Navigation System-Guided Microwave Ablation of Hepatic Tumors: A Matched Cohort Study. CardioVascular and Interventional Radiology, 44(3), 500–506. https://doi.org/10.1007/s00270-020-02761-6
- Scharll, Y., Böhler, D., Laimer, G., Schullian, P., & Bale, R. (2023). Laser Target System in Combination with an Aiming Device for Percutaneous CT-Guided Interventions – An Accuracy Study. Academic Radiology, 30(12), 3047–3055. https://doi.org/10.1016/j.acra.2023.03.028
- Lin, C.-Y., Tang, W.-R., Chiang, P.-C., Lien, J.-J. J., Tseng, P.-Y., Liu, Y.-S., Chang, C.-C., & Tseng, Y.-L. (2023). Improving puncture accuracy in percutaneous CT-guided needle insertion with wireless inertial measurement unit: a phantom study. European Radiology, 33(5), 3156–3164. https://doi.org/10.1007/s00330-023-09467-6
- Matsui, Y., Hiraki, T., Gobara, H., Iguchi, T., Fujiwara, H., Kawabata, T., Yamauchi, T., Yamaguchi, T., & Kanazawa, S. (2016). Radiation Exposure of Interventional Radiologists During Computed Tomography Fluoroscopy-Guided Renal Cryoablation and Lung Radiofrequency Ablation: Direct Measurement in a Clinical Setting. CardioVascular and Interventional Radiology, 39(6), 894–901. https://doi.org/10.1007/s00270-016-1308-3
- Wagner, M. G., Hinshaw, J. L., Li, Y., Szczykutowicz, T. P., Laeseke, P., Mistretta, C. A., & Lee, F. T. (2019). Ultra–Low Radiation Dose CT Fluoroscopy for Percutaneous Interventions: A Porcine Feasibility Study. Radiology, 291(1), 241–249. https://doi.org/10.1148/radiol.2019181362
- Kwak, D. H., Ahmed, O., Habib, H., Nijhawan, K., Kumari, D., & Patel, M. (2022). Hybrid CT-angiography (Angio-CT) for combined CT and fluoroscopic procedures in interventional radiology enhances utilization. Abdominal Radiology, 47(8), 2704–2711. https://doi.org/10.1007/s00261-022-03576-4
- Feinberg, N., Funaki, B., Hieromnimon, M., Guajardo, S., Navuluri, R., Zangan, S., Lorenz, J., & Ahmed, O. (2020). Improved Utilization Following Conversion of a Fluoroscopy Suite to Hybrid CT/Angiography System. Journal of Vascular and Interventional Radiology, 31(11), 1857–1863. https://doi.org/10.1016/j.jvir.2020.05.028
- Knox, J. A., Kumar, V., Conrad, M. B., Nanavati, S., Moore, T., & Wilson, M. (2022). Synergy in IR–Hybrid CT/C-arm in the setting of critical trauma. Emergency Radiology, 29(3), 605–609. https://doi.org/10.1007/s10140-022-02015-7
- Nunninger, M., Braun, V. P. B., Ziegert, M., Schwarz, F. B., Hamm, B., Scheel, M., & Jahnke, P. (2019). Scout-guided needle placement—a technical approach for dose reduction in CT-guided periradicular infiltration. Neuroradiology, 62(3), 341–346. https://doi.org/10.1007/s00234-019-02339-1
- Gaspoz, F., Monnin, P., Petter, D., Plé, J., & Ding, S. (2015). Precision and Accuracy of Measurements on CT Scout View. Journal of Medical Imaging and Radiation Sciences, 46(3), 309–316. https://doi.org/10.1016/j.jmir.2015.06.006
- Johnson, P. T., Scott, W. W., Gayler, B. W., Lewin, J. S., & Fishman, E. K. (2014). The CT Scout View: Does It Need to Be Routinely Reviewed as Part of the CT Interpretation?. American Journal of Roentgenology, 202(6), 1256–1263. https://doi.org/10.2214/ajr.13.10545
- Orman, G., Bosemani, T., Tekes, A., Poretti, A., & Huisman, T. A. G. M. (2013). Scout view in pediatric CT neuroradiological evaluation: do not underestimate!. Child's Nervous System, 30(2), 307–311. https://doi.org/10.1007/s00381-013-2288-0
- Nauer, C. B., Kellner-Weldon, F., Von Allmen, G., Schaller, D., & Gralla, J. (2008). Effective Doses from Scan Projection Radiographs of the Head: Impact of Different Scanning Practices and Comparison with Conventional Radiography. American Journal of Neuroradiology, 30(1), 155–159. https://doi.org/10.3174/ajnr.a1293
- Colello, M. J., Pichiotino, E. R., Tanner, S. L., Porter, S. E., & Gurich, R. W. (2020). Predicting Pathologic Bone Lesions Using Scout Computed Tomography (CT) Imaging. Sarcoma, 2020, 1–8. https://doi.org/10.1155/2020/5105196
- Theocharopoulos, N., Chatzakis, G., Karantanas, A., Chlapoutakis, K., & Damilakis, J. (2010). CT evaluation of the low severity cervical spine trauma: When is the scout view enough?. European Journal of Radiology, 75(1), 82–86. https://doi.org/10.1016/j.ejrad.2009.03.024