Published June 18, 2020 | Journal article | Version v1 | https://doi.org/10.1097/mao.0000000000002714

Hearing Preservation With a New Atraumatic Lateral Wall Electrode

Description

Introduction: Many individuals have some residual hearing which should be preserved with cochlear implantation. To achieve this goal electrode arrays must fulfil certain design requirements. A new thin lateral wall electrode array (HiFocus SlimJ) was systematically designed on the basis of μCT studies of human cochlea anatomy. The primary objective of this study was to report on initial retrospective hearing preservation results from a cohort of subjects consecutively implanted with this electrode. Secondary objectives were to report on insertion depth and speech perception results for this new array. Methods: Twenty subjects with considerable residual hearing in low frequencies were consecutively implanted with the SlimJ electrode array. The electrode was inserted slowly through the round window and the insertion process was controlled by intracochlear electrocochleography measuring cochlear microphonics through the cochlear implant. Postoperative cone beam computed tomography was conducted and precise scalar location and angular insertion depth was estimated following image fusion with the preoperative images. Results: Low frequency hearing at 1 month postsurgery was preserved within 30 dB HL in 85% of subjects and within 15 dB HL in 50% of subjects. Mean angular insertion depth was 393 degrees (SD 62 degrees) with a range from 294 to 520 degrees. All electrode contacts in all subjects were identified within scala tympani. Conclusion: The SlimJ electrode array is easy to handle for atraumatic insertion through the round window, adjusted insertion depth controlled by electrocochleography measurements, and reliable fixation at the posterior tympanotomy. Hearing preservation rates are encouraging on the short term. We aim to further report on larger data sets and long-term outcomes.

Additional details

Dates

Issued
June 18, 2020

References

  1. Gifford, R. H., Dorman, M. F., Skarzynski, H., Lorens, A., Polak, M., Driscoll, C. L. W., Roland, P., & Buchman, C. A. (2013). Cochlear Implantation With Hearing Preservation Yields Significant Benefit for Speech Recognition in Complex Listening Environments. Ear & Hearing, 34(4), 413–425. https://doi.org/10.1097/aud.0b013e31827e8163
  2. Holden, L. K., Finley, C. C., Firszt, J. B., Holden, T. A., Brenner, C., Potts, L. G., Gotter, B. D., Vanderhoof, S. S., Mispagel, K., Heydebrand, G., & Skinner, M. W. (2013). Factors Affecting Open-Set Word Recognition in Adults With Cochlear Implants. Ear & Hearing, 34(3), 342–360. https://doi.org/10.1097/aud.0b013e3182741aa7
  3. Carlson, M. L., Driscoll, C. L. W., Gifford, R. H., Service, G. J., Tombers, N. M., Hughes-Borst, B. J., Neff, B. A., & Beatty, C. W. (2011). Implications of Minimizing Trauma During Conventional Cochlear Implantation. Otology & Neurotology, 32(6), 962–968. https://doi.org/10.1097/mao.0b013e3182204526
  4. Finley, C. C., Holden, T. A., Holden, L. K., Whiting, B. R., Chole, R. A., Neely, G. J., Hullar, T. E., & Skinner, M. W. (2008). Role of Electrode Placement as a Contributor to Variability in Cochlear Implant Outcomes. Otology & Neurotology, 29(7), 920–928. https://doi.org/10.1097/mao.0b013e318184f492
  5. Aschendorff, A., Kromeier, J., Klenzner, T., & Laszig, R. (2007). Quality Control After Insertion of the Nucleus Contour and Contour Advance Electrode in Adults. Ear & Hearing, 28(2), 75S–79S. https://doi.org/10.1097/aud.0b013e318031542e
  6. Incerti, P. V., Ching, T. Y. C., & Cowan, R. (2013). A Systematic Review of Electric-Acoustic Stimulation. Trends in Amplification, 17(1), 3–26. https://doi.org/10.1177/1084713813480857
  7. Lenarz, T., James, C., Cuda, D., Fitzgerald O'Connor, A., Frachet, B., Frijns, J. H. M., Klenzner, T., Laszig, R., Manrique, M., Marx, M., Merkus, P., Mylanus, E. A. M., Offeciers, E., Pesch, J., Ramos-Macias, A., Robier, A., Sterkers, O., & Uziel, A. (2013). European multi-centre study of the Nucleus Hybrid L24 cochlear implant. International Journal of Audiology, 52(12), 838–848. https://doi.org/10.3109/14992027.2013.802032
  8. Zhang, T., Dorman, M. F., & Spahr, A. J. (2010). Information From the Voice Fundamental Frequency (F0) Region Accounts for the Majority of the Benefit When Acoustic Stimulation Is Added to Electric Stimulation. Ear & Hearing, 31(1), 63–69. https://doi.org/10.1097/aud.0b013e3181b7190c
  9. Wanna, G. B., O'Connell, B. P., Francis, D. O., Gifford, R. H., Hunter, J. B., Holder, J. T., Bennett, M. L., Rivas, A., Labadie, R. F., & Haynes, D. S. (2017). Predictive factors for short‐ and long‐term hearing preservation in cochlear implantation with conventional‐length electrodes. The Laryngoscope, 128(2), 482–489. https://doi.org/10.1002/lary.26714
  10. Eshraghi, A. A., Ahmed, J., Krysiak, E., Ila, K., Ashman, P., Telischi, F. F., Angeli, S., Prentiss, S., Martinez, D., & Valendia, S. (2016). Clinical, surgical, and electrical factors impacting residual hearing in cochlear implant surgery. Acta Oto-Laryngologica, 137(4), 384–388. https://doi.org/10.1080/00016489.2016.1256499
  11. O'Connell, B. P., Hunter, J. B., & Wanna, G. B. (2016). The importance of electrode location in cochlear implantation. Laryngoscope Investigative Otolaryngology, 1(6), 169–174. https://doi.org/10.1002/lio2.42
  12. Connor, S. E. J., Holland, N. J., Agger, A., Leong, A. C., Varghese, R. A., Jiang, D., & Fitzgerald O'Connor, A. (2012). Round window electrode insertion potentiates retention in the scala tympani. Acta Oto-Laryngologica, 132(9), 932–937. https://doi.org/10.3109/00016489.2012.680493
  13. Mittmann, P., Mittmann, M., Ernst, A., & Todt, I. (2016). Intracochlear Pressure Changes due to 2 Electrode Types: An Artificial Model Experiment. Otolaryngology–Head and Neck Surgery, 156(4), 712–716. https://doi.org/10.1177/0194599816684104
  14. Todt, I., Mittmann, M., Ernst, A., & Mittmann, P. (2016). Comparison of the effects of four different cochlear implant electrodes on intra-cochlear pressure in a model. Acta Oto-Laryngologica, 137(3), 235–241. https://doi.org/10.1080/00016489.2016.1232490
  15. Stakhovskaya, O., Sridhar, D., Bonham, B. H., & Leake, P. A. (2007). Frequency Map for the Human Cochlear Spiral Ganglion: Implications for Cochlear Implants. Journal of the Association for Research in Otolaryngology, 8(2), 220–233. https://doi.org/10.1007/s10162-007-0076-9
  16. Carlyon, R. P., Macherey, O., Frijns, J. H. M., Axon, P. R., Kalkman, R. K., Boyle, P., Baguley, D. M., Briggs, J., Deeks, J. M., Briaire, J. J., Barreau, X., & Dauman, R. (2010). Pitch Comparisons between Electrical Stimulation of a Cochlear Implant and Acoustic Stimuli Presented to a Normal-hearing Contralateral Ear. Journal of the Association for Research in Otolaryngology, 11(4), 625–640. https://doi.org/10.1007/s10162-010-0222-7
  17. Frijns, . >Johan H. M., Kalkman, R. K., Vanpoucke, F. J., Bongers, J. S., & Briaire, J. J. (2009). Simultaneous and non-simultaneous dual electrode stimulation in cochlear implants: evidence for two neural response modalities. Acta Oto-Laryngologica, 129(4), 433–439. https://doi.org/10.1080/00016480802610218
  18. O'Connell, B. P., Cakir, A., Hunter, J. B., Francis, D. O., Noble, J. H., Labadie, R. F., Zuniga, G., Dawant, B. M., Rivas, A., & Wanna, G. B. (2016). Electrode Location and Angular Insertion Depth Are Predictors of Audiologic Outcomes in Cochlear Implantation. Otology & Neurotology, 37(8), 1016–1023. https://doi.org/10.1097/mao.0000000000001125
  19. Svrakic, M., Roland, J. T., McMenomey, S. O., & Svirsky, M. A. (2016). Initial Operative Experience and Short-term Hearing Preservation Results With a Mid-scala Cochlear Implant Electrode Array. Otology & Neurotology, 37(10), 1549–1554. https://doi.org/10.1097/mao.0000000000001238
  20. Adunka, O., & Kiefer, J. (2006). Impact of electrode insertion depth on intracochlear trauma. Otolaryngology–Head and Neck Surgery, 135(3), 374–382. https://doi.org/10.1016/j.otohns.2006.05.002
  21. Suhling, M.-C., Majdani, O., Salcher, R., Leifholz, M., Büchner, A., Lesinski-Schiedat, A., & Lenarz, T. (2016). The Impact of Electrode Array Length on Hearing Preservation in Cochlear Implantation. Otology & Neurotology, 37(8), 1006–1015. https://doi.org/10.1097/mao.0000000000001110
  22. Neben, N., Buechner, A., Schuessler, M., & Lenarz, T. (2017). Outcome evaluation on cochlear implant users with residual hearing. Cochlear Implants International, 19(2), 88–99. https://doi.org/10.1080/14670100.2017.1390852
  23. Jurawitz, M.-C., Büchner, A., Harpel, T., Schüssler, M., Majdani, O., Lesinski-Schiedat, A., & Lenarz, T. (2014). Hearing Preservation Outcomes with Different Cochlear Implant Electrodes: Nucleus® Hybrid™-L24 and Nucleus Freedom™ CI422. Audiology and Neurotology, 19(5), 293–309. https://doi.org/10.1159/000360601
  24. Cohen, L. T., Saunders, E., Knight, M. R., & Cowan, R. S. C. (2006). Psychophysical measures in patients fitted with Contour™ and straight Nucleus electrode arrays. Hearing Research, 212(1-2), 160–175. https://doi.org/10.1016/j.heares.2005.11.005
  25. Jeyakumar, A., Peña, S. F., & Brickman, T. M. (2014). Round Window Insertion of Precurved Electrodes Is Traumatic. Otology & Neurotology, 35(1), 52–57. https://doi.org/10.1097/mao.0000000000000194

1–25 of 51

Citations

  1. Thompson, N. J., Brown, K. D., Buss, E., Nix, E. P., Overton, A. B., Selleck, A. M., Dedmon, M. M., & Dillon, M. T. (2026). Cochlear Implant Recipients With Electrodes in the Acoustic Region: Long‐Term Hearing Preservation. The Laryngoscope, 136(7), 3203–3210. https://doi.org/10.1002/lary.70472
  2. Huang, T. C., & Lunos, S. (2026). Hearing Preservation Rates After Cochlear Implantation Using Soft Surgery Techniques. The Laryngoscope, 136(11), 4996–5002. https://doi.org/10.1002/lary.70664
  3. Ibrahim, S. A., Sobhy, T. S., Shoeib, S. A., & Teaima, A. A. (2026). Comparison of the Outcomes of Lateral Wall, Perimodiolar, and Midscala Electrodes in Cochlear Implantation Surgery: A Meta-Analysis. International Archives of Otorhinolaryngology, 30(03), 001–009. https://doi.org/10.1055/s-0046-1820087
  4. Lind, M. J., Dunn, C. C., Claussen, A. D., Gantz, B. J., Hansen, M. R., Goodman, S. S., & Scheperle, R. A. (2026). Longitudinal Acoustic Threshold and Concurrent Electrode Impedance Changes After Cochlear Implantation With Lateral Wall Electrode Arrays. Otology & Neurotology. https://doi.org/10.1097/mao.0000000000004855
  5. Gisbert Aguilar, J., Platero Zamarreño, A., De Paula Vernetta, C., Guzmán Calvete, A., Martín-Lagos Martínez, J., Müller Locatelli, N., Martínez Martínez, M., & Martínez de Estíbariz Cerdán, U. (2026). Positive intra-operative electrocochleography track patterns with the HiFocus SlimJ electrode array are associated with stable and improved hearing preservation rates. Frontiers in Audiology and Otology, 3. https://doi.org/10.3389/fauot.2025.1708896
  6. Chatterjee, M., Tejani, V. D., & Schvartz-Leyzac, K. C. (2025). Cochlear Implants: Signal Coding Strategies. In Advances in Implantation Otology (pp. 249–276). Springer Nature Singapore. https://doi.org/10.1007/978-981-96-8671-1_15
  7. Ordóñez Ordóñez, L. E., Angulo Martinez, E. S., Vanegas, S. C., Hernández, E. C., Peroza Fuentes, E., Dwyer, R. T., & Martinho-Carvalho, A. C. (2025). Intra and postoperative electrocochleography in cochlear implant recipients: retrospective chart review. Cochlear Implants International, 26(2), 139–149. https://doi.org/10.1080/14670100.2025.2515703
  8. Walia, A., Shew, M. A., Lee, D. S., Ortmann, A., Varghese, J., Lefler, S., Durakovic, N., Wick, C. C., Herzog, J. A., & Buchman, C. A. (2025). Electrocochleography-Guided Pull-Back Technique of Perimodiolar Electrode for Improved Hearing Preservation. Otology & Neurotology, 46(7), 766–774. https://doi.org/10.1097/mao.0000000000004407
  9. Klausner, M. S., Valley, Z. A., Bornstein, R., Albinus, R., Koka, K., & Stidham, K. R. (2025). Intraoperative Electrocochleography Audiogram: Correlation With Postoperative Audiometric Results in Patients With Residual Hearing. Otology & Neurotology, 47(2), e208–e215. https://doi.org/10.1097/mao.0000000000004724
  10. Samuel, O., Denanto, F. M., Dalbert, A., Collins, A., Shute, W., Bester, C., & O'Leary, S. (2025). Intraoperative Intracochlear Electrocochleography and Hearing Preservation Early after Cochlear Implantation: A Meta-Analysis. Audiology and Neurotology, 1–16. https://doi.org/10.1159/000549281
  11. Haumann, S., Büchner, A., Lenarz, T., & Salcher, R. B. (2025). Hearing preservation after cochlear implantation evaluated using Auditory Steady State Responses. Frontiers in Audiology and Otology, 3. https://doi.org/10.3389/fauot.2025.1560648
  12. Fan, Y., & Gifford, R. H. (2024). Objective measure of binaural processing: Acoustic change complex in response to interaural phase differences. Hearing Research, 448, 109020. https://doi.org/10.1016/j.heares.2024.109020
  13. Harris, M. S., Koka, K., Thompson-Harvey, A., Harvey, E., Riggs, W. J., Saleh, S., Holder, J. T., Dwyer, R. T., Prentiss, S. M., Lefler, S. M., Kozlowski, K., Hiss, M. M., Ortmann, A. J., Nelson-Bakkum, E. R., Büchner, A., Salcher, R., Harvey, S. A., Hoffer, M. E., Bohorquez, J. E., … Adunka, O. F. (2024). Amplitude Parameters Are Predictive of Hearing Preservation in a Randomized Controlled Trial of Intracochlear Electrocochleography During Cochlear Implant Surgery. Otology & Neurotology, 45(8), 887–894. https://doi.org/10.1097/mao.0000000000004286
  14. Meuser, M., Schwitzer, S., Thiele, M., Boyle, P., Ernst, A., & Basta, D. (2024). Intra-Cochlear Electrode Position Impacts the Preservation of Residual Hearing in an Animal Model of Cochlear Implant Surgery. Audiology and Neurotology, 1–11. https://doi.org/10.1159/000540266
  15. Haumann, S., Timm, M. E., Büchner, A., Lenarz, T., & Salcher, R. B. (2024). Intracochlear Recording of Electrocochleography During and After Cochlear Implant Insertion Dependent on the Location in the Cochlea. Trends in Hearing, 28. https://doi.org/10.1177/23312165241248973
  16. Haumann, S., Mynarek (née Bradler), M., Maier, H., Helmstaedter, V., Büchner, A., Lenarz, T., & Teschner, M. J. (2024). Does Intraoperative Extracochlear Electrocochleography Correlate With Postoperative Audiometric Hearing Thresholds in Cochlear Implant Surgery? A Retrospective Analysis of Cochlear Monitoring. Trends in Hearing, 28. https://doi.org/10.1177/23312165241252240
  17. Vecchi, J. T., Claussen, A. D., & Hansen, M. R. (2024). Decreasing the physical gap in the neural-electrode interface and related concepts to improve cochlear implant performance. Frontiers in Neuroscience, 18. https://doi.org/10.3389/fnins.2024.1425226
  18. Geys, M., Sijgers, L., Dobrev, I., Dalbert, A., Röösli, C., Pfiffner, F., & Huber, A. (2024). ZH-ECochG Bode Plot: A Novel Approach to Visualize Electrocochleographic Data in Cochlear Implant Users. Journal of Clinical Medicine, 13(12), 3470. https://doi.org/10.3390/jcm13123470
  19. Thompson, N. J., Dillon, M. T., Nix, E. P., Overton, A. B., Selleck, A. M., Dedmon, M. M., & Brown, K. D. (2023). Variables Affecting Cochlear Implant Performance After Loss of Residual Hearing. The Laryngoscope, 134(4), 1868–1873. https://doi.org/10.1002/lary.31066
  20. Höing, B., Eichler, T., Juelly, V., Meyer, M., Jung, L., Waschkies, L., Lang, S., & Arweiler-Harbeck, D. (2023). Digital live imaging of intraoperative electrocochleography during cochlear implantation: the first 50 patients. European Archives of Oto-Rhino-Laryngology, 281(3), 1175–1183. https://doi.org/10.1007/s00405-023-08197-1
  21. Patro, A., Lindquist, N. R., Schauwecker, N., Holder, J. T., Perkins, E. L., Haynes, D. S., & Tawfik, K. O. (2023). Comparison of Speech Recognition and Hearing Preservation Outcomes Between the Mid-Scala and Lateral Wall Electrode Arrays. Otology & Neurotology, 45(1), 52–57. https://doi.org/10.1097/mao.0000000000004064
  22. Dillon, M. T., Buss, E., Johnson, A. D., Canfarotta, M. W., & O'Connell, B. P. (2023). Comparison of Two Place-Based Mapping Procedures on Masked Sentence Recognition as a Function of Electrode Array Angular Insertion Depth and Presence of Acoustic Low-Frequency Information: A Simulation Study. Audiology and Neurotology, 28(6), 478–487. https://doi.org/10.1159/000531262
  23. Jwair, S., Versnel, H., Stokroos, R. J., & Thomeer, H. G. X. M. (2022). The effect of the surgical approach and cochlear implant electrode on the structural integrity of the cochlea in human temporal bones. Scientific Reports, 12(1). https://doi.org/10.1038/s41598-022-21399-7
  24. Lenarz, T., Büchner, A., & Illg, A. (2022). Cochlea-Implantation: Konzept, Therapieergebnisse und Lebensqualität. Laryngo-Rhino-Otologie, 101(S 01), S36–S78. https://doi.org/10.1055/a-1731-9321
  25. Gendre, A., Quinn, S., Jones, H., Hintze, J., Simões-Franklin, C., Walshe, P., Viani, L., & Glynn, F. (2022). National study of hearing preservation rates and outcomes after cochlear implantation in Ireland. Cochlear Implants International, 23(5), 241–248. https://doi.org/10.1080/14670100.2022.2061102

1–25 of 36