Published July 1, 1998 | Journal article | Version v1 | https://doi.org/10.1136/hrt.80.1.54

Extending the limits of transcatheter closure of atrial septal defects with the double umbrella device (CardioSEAL)

Description

Objective To report initial findings from a selected group of patients with morphological variations of the atrial septal defect who underwent transcatheter closure with a second generation redesigned double umbrella device. Patients Two patients with abnormal location of the oval fossa and partial deficiency of the septal rim, three patients with multiple defects, and two patients with a multiperforated aneurysm of the interatrial septum (age range, 3.6–25.5 years). Methods Defects were closed with the double umbrella device (CardioSEAL) consisting of two sets of flexible arms (with central and two mid-arm hinges) covered with sewn Dacron patches. The implantation procedure was monitored by transoesophageal echocardiography. Results The diameter of the defect measured during transoesophageal echocardiography ranged from 7–18 mm and the balloon stretched diameter ranged from 13–21 mm. The size of the devices varied from 28–33 mm and the ratio of device size to defect size varied from 1.6–2.1. Two devices (23 and 28 mm) were chosen in a patient with two separated defects. No complications or serious arrhythmias were observed during implantation or follow up (median, 1.8 months). Residual shunting was trivial in three patients and mild in one patient (inferiorly located additional defect). Conclusions To extend the selection critera of an isolated central interatrial defect for transcatheter closure, some modifications of the implantation technique are needed. Using the redesigned double umbrella device, effective closure in patients with multiple or irregularly shaped atrial septal defects was achieved, indicating a broadening of the spectrum of transcatheter closure.

Additional details

Dates

Issued
July 1, 1998

References

  1. Rao, P. S., Sideris, E. B., Hausdort, G., Rey, C., Lloyd, T. R., Beekman, R. H., Worms, A. M., Bourlon, F., Onorato, E., Khalilullah, M., & Haddad, J. (1994). International experience with secundum atrial septal defect occlusion by the buttoned device. American Heart Journal, 128(5), 1022–1035. https://doi.org/10.1016/0002-8703(94)90602-5
  2. Redington, A. N., & Rigby, M. L. (1994). Transcatheter closure of interatrial communications with a modified umbrella device. Heart, 72(4), 372–377. https://doi.org/10.1136/hrt.72.4.372
  3. Ende, D. J., Chopra, P. S., & Rao, P. S. (1996). Transcatheter closure of atrial septal defect or patent foramen ovale with the buttoned device for prevention of recurrence of paradoxic embolism. The American Journal of Cardiology, 78(2), 233–236. https://doi.org/10.1016/s0002-9149(96)90405-1
  4. Bridges, N. D., Hellenbrand, W., Latson, L., Filiano, J., Newburger, J. W., & Lock, J. E. (1992). Transcatheter closure of patent foramen ovale after presumed paradoxical embolism. Circulation, 86(6), 1902–1908. https://doi.org/10.1161/01.cir.86.6.1902
  5. Justo, R. N., Nykanen, D. G., Boutin, C., McCrindle, B. W., Freedom, R. M., & Benson, L. N. (1996). Clinical impact of transcatheter closure of secundum atrial septal defects with the double umbrella device. The American Journal of Cardiology, 77(10), 889–892. https://doi.org/10.1016/s0002-9149(97)89192-8
  6. Rome, J. J., Keane, J. F., Perry, S. B., Spevak, P. J., & Lock, J. E. (1990). Double-umbrella closure of atrial defects. Initial clinical applications. Circulation, 82(3), 751–758. https://doi.org/10.1161/01.cir.82.3.751
  7. Transcatheter closure of atrial septal defect with a prototype clamshell septal umbrella: one year follow-up.
  8. Schenck, M. H., Sterba, R., Foreman, C. K., & Latson, L. A. (1995). Improvement in noninvasive electrophysiologic findings in children after transcatheter atrial septal defect closure. The American Journal of Cardiology, 76(10), 695–698. https://doi.org/10.1016/s0002-9149(99)80199-4
  9. King, T. D., Thompson, S. L., & Mills, N. L. (1978). Measurement of atrial septal defect during cardiac catheterization. The American Journal of Cardiology, 41(3), 537–542. https://doi.org/10.1016/0002-9149(78)90012-7
  10. Rao, P. S., & Langhough, R. (1991). Relationship of echocardiographic, shunt flow, and angiographic size to the stretched diameter of the atrial septal defect. American Heart Journal, 122(2), 505–508. https://doi.org/10.1016/0002-8703(91)91008-b
  11. Reddy, S. C. B., Rao, P. S., Ewenko, J., Koscik, R., & Wilson, A. D. (1995). Echocardiographic predictors of success of catheter closure of atrial septal defect with the buttoned device. American Heart Journal, 129(1), 76–82. https://doi.org/10.1016/0002-8703(95)90046-2
  12. Hickey, P. R., Wessel, D. L., Streitz, S. L., Fox, M. L., Kern, F. H., Bridges, N. D., & Hansen, D. D. (1992). Transcatheter Closure of Atrial Septal Defects. Anesthesia & Analgesia, 74(1), 44???50. https://doi.org/10.1213/00000539-199201000-00008
  13. Das, G. S., Voss, G., Jarvis, G., Wyche, K., Gunther, R., & Wilson, R. F. (1993). Experimental atrial septal defect closure with a new, transcatheter, self-centering device. Circulation, 88(4), 1754–1764. https://doi.org/10.1161/01.cir.88.4.1754
  14. Hausdorf, G., Schneider, M., Franzbach, B., Kampmann, C., Kargus, K., & Goeldner, B. (1996). Transcatheter closure of secundum atrial septal defects with the atrial septal defect occlusion system (ASDOS): initial experience in children. Heart, 75(1), 83–88. https://doi.org/10.1136/hrt.75.1.83
  15. Boutin, C., Musewe, N. N., Smallhorn, J. F., Dyck, J. D., Kobayashi, T., & Benson, L. N. (1993). Echocardiographic follow-up of atrial septal defect after catheter closure by double-umbrella device. Circulation, 88(2), 621–627. https://doi.org/10.1161/01.cir.88.2.621
  16. Ferreira, S. M., Ho, S. Y., & Anderson, R. H. (1992). Morphological study of defects of the atrial septum within the oval fossa: implications for transcatheter closure of left-to-right shunt. Heart, 67(4), 316–320. https://doi.org/10.1136/hrt.67.4.316
  17. Echocardiographic predictors of candidacy for successful transcatheter atrial septal defect closure.
  18. Godart, F., Rey, C., Francart, C., Jarrar, M., & Vaksmann, G. (1993). Two-dimensional echocardiographic and color doppler measurements of atrial septal defect, and comparison with the balloon-stretched diameter. The American Journal of Cardiology, 72(14), 1095–1097. https://doi.org/10.1016/0002-9149(93)90873-b

Citations

  1. De Cillis, E., Acquaviva, T., Ursi, R., Soldato, N., Basile, P., Siena, P., Carella, M. C., Baggiano, A., Mushtaq, S., Fusini, L., Rabbat, M. G., Pontone, G., Bottio, T., Bortone, A. S., Ciccone, M. M., Milano, A. D., & Guaricci, A. I. (2023). A comparison of intracardiac echocardiography and transesophageal echocardiography for guiding device closure of ostium secundum atrial septal defect: A 15‐year experience. Echocardiography, 41(1). https://doi.org/10.1111/echo.15724
  2. Drexler, I. R., Legasto, A. C., Green, D. B., & Truong, Q. A. (2019). Cardiac Devices. In Contemporary Medical Imaging (pp. 487–500). Humana Press. https://doi.org/10.1007/978-1-60327-237-7_40
  3. Taha, F., & Elshedoudy, S. (2019). Role of 3D transesophageal echocardiography in transcatheter closure of atrial septal aneurysms. Echocardiography, 36(10), 1884–1894. https://doi.org/10.1111/echo.14482
  4. Jea, S. J., Kwon, H. J., Jang, G. Y., Lee, J. Y., Kim, S. J., Son, C. S., & Lee, J. W. (2008). Complications of transcatheter closure of atrial septal defects using the amplatzer septal occluder. Korean Journal of Pediatrics, 51(4), 401. https://doi.org/10.3345/kjp.2008.51.4.401
  5. Numan, M., El Sisi, A., Tofeig, M., Gendi, S., Tohami, T., & El-Said, H. G. (2007). Cribriform Amplatzer Device Closure of Fenestrated Atrial Septal Defects: Feasibility and Technical Aspects. Pediatric Cardiology, 29(3), 530–535. https://doi.org/10.1007/s00246-007-9079-x
  6. Baglini, R. (2007). Intracardiac echocardiography in monitoring atrial septal defect percutaneous closure: Initial experience in an adult laboratory. International Journal of Cardiology, 114(2), 274–276. https://doi.org/10.1016/j.ijcard.2005.11.069
  7. Bjørnstad, P. G. (2006). Is interventional closure the current treatment of choice for selected patients with deficient atrial septation?. Cardiology in the Young, 16(1), 3–10. https://doi.org/10.1017/s1047951105002027
  8. Boucek, M. (2005). Patent foramen ovale closure: role of the pediatric cardiologist. Cardiology Clinics, 23(1), 35–45. https://doi.org/10.1016/j.ccl.2004.10.011
  9. Blom, N. A., Ottenkamp, J., Jongeneel, T. H., DeRuiter, M. C., & Groot, A. C. G.-. de . (2004). Morphogenetic Differences of Secundum Atrial Septal Defects. Pediatric Cardiology, 26(4), 338–343. https://doi.org/10.1007/s00246-004-0711-8
  10. Kay, J. D., O'Laughlin, M. P., Ito, K., Wang, A., Bashore, T. M., & Harrison, J. K. (2004). Five-year clinical and echocardiographic evaluation of the Das AngelWings atrial septal occluder. American Heart Journal, 147(2), 361–368. https://doi.org/10.1016/j.ahj.2003.07.018
  11. Wang, J.-K., Tsai, S.-K., Wu, M.-H., Lin, M.-T., & Lue, H.-C. (2004). Short- and intermediate-term results of transcatheter closure of atrial septal defect with the Amplatzer Septal Occluder. American Heart Journal, 148(3), 511–517. https://doi.org/10.1016/j.ahj.2004.01.030
  12. Butera, G., Carminati, M., Chessa, M., Delogu, A., Drago, M., Piazza, L., Giamberti, A., & Frigiola, A. (2004). CardioSEAL/STARflex versus Amplatzer devices for percutaneous closure of small to moderate (up to 18 mm) atrial septal defects. American Heart Journal, 148(3), 507–510. https://doi.org/10.1016/j.ahj.2004.03.013
  13. Hijazi, Z., & Cao, Q.-L. (2004). Catheter Closure of a Large Atrial Septal Defect (ASD) Using the Amplatzer Septal Occluder (ASO) Device. In Case Studies in Interventional Cardiology (pp. 143–146). CRC Press. https://doi.org/10.1201/b14293-28
  14. FAELLA, H. J., SCIEGATA, A. M., ALONSO, J. L., & JMELNITSKY, L. (2003). ASD Closure with the Amplatzer Device. Journal of Interventional Cardiology, 16(5), 393–397. https://doi.org/10.1046/j.1540-8183.2003.01006.x
  15. KOENIG, P., CAO, Q., HEITSCHMIDT, M., WAIGHT, D. J., & HIJAZI, Z. M. (2003). Role of Intracardiac Echocardiographic Guidance in Transcatheter Closure of Atrial Septal Defects and Patent Foramen Ovale Using the Amplatzer® Device. Journal of Interventional Cardiology, 16(1), 51–62. https://doi.org/10.1046/j.1540-8183.2003.08003.x
  16. Kim, J.-H., Siegel, M. J., Goldstein, J. A., Gutierrez, F. R., & Lasala, J. M. (2003). Radiologic Findings of 2 Commonly Used Cardiac Septal Occluders with Clinical Correlation. Journal of Thoracic Imaging, 18(3), 183–189. https://doi.org/10.1097/00005382-200307000-00008
  17. Brandt, R. R., Neumann, T., Neuzner, J., Rau, M., Faude, I., & Hamm, C. W. (2002). Transcatheter closure of atrial septal defect and patent foramen ovale in adult patients using the Amplatzer occlusion device: No evidence for thrombus deposition with antiplatelet agents. Journal of the American Society of Echocardiography, 15(10), 1094–1098. https://doi.org/10.1067/mje.2002.121666
  18. Hijazi, Z. M., Wang, Z., Cao, Q.-L., Koenig, P., Waight, D., & Lang, R. (2001). Transcatheter closure of atrial septal defects and patent foramen ovale under intracardiac echocardiographic guidance: Feasibility and comparison with transesophageal echocardiography. Catheterization and Cardiovascular Interventions, 52(2), 194–199. https://doi.org/10.1002/1522-726x(200102)52:2%3c194::aid-ccd1046%3e3.0.co;2-4
  19. Lee, C., Kwok, O., Fan, K., Chau, E., Yip, A., & Chow, W. (2001). Transcatheter closure of atrial septal defect using Amplatzer septal occluder in Chinese adults. Catheterization and Cardiovascular Interventions, 53(3), 373–377. https://doi.org/10.1002/ccd.1184
  20. Dobrolet, N. C., Iskowitz, S., Lopez, L., Whalen, R., & Zahn, E. M. (2001). Sequential implantation of two helex septal occluder devices in a patient with complex atrial septal anatomy. Catheterization and Cardiovascular Interventions, 54(2), 242–246. https://doi.org/10.1002/ccd.1276
  21. Celiker, A., Bilgic, A., Ozkutlu, S., Demircin, M., Karagoz, T., & Ayabakan, C. (2001). A late complication with the cardioSEAL ASD occluder device and need for surgical revision. Catheterization and Cardiovascular Interventions, 54(3), 335–338. https://doi.org/10.1002/ccd.1294
  22. CARMINATI, M., CHESSA, M., BUTERA, G., BINI, R. M., GIUSTI, S., FESTA, P., SPADONI, I., REDAELLI, S., & HAUSDORF, G. (2001). Transcatheter Closure of Atrial Septal Defects with the STARFlex Device: Early Results and Follow‐Up. Journal of Interventional Cardiology, 14(3), 319–324. https://doi.org/10.1111/j.1540-8183.2001.tb00339.x
  23. OMEISH, A., & HIJAZI, Z. M. (2001). Transcatheter Closure of Atrial Septal Defects in Children & Adults Using the Amplatzer Septal Occluder. Journal of Interventional Cardiology, 14(1), 37–44. https://doi.org/10.1111/j.1540-8183.2001.tb00709.x
  24. HAUSDORF, G. (2001). StarFlex ASD Closure: Deployment, Techniques, Equipment. Journal of Interventional Cardiology, 14(1), 69–76. https://doi.org/10.1111/j.1540-8183.2001.tb00715.x
  25. Acar, P., Saliba, Z., Bonhoeffer, P., Sidi, D., & Kachaner, J. (2001). Assessment of the geometric profile of the Amplatzer and Cardioseal septal occluders by three dimensional echocardiography. Heart, 85(4), 451–453. https://doi.org/10.1136/heart.85.4.451

1–25 of 46