ARMA – Filtering of Evoked Potentials
Description
SummaryA method of evoked potential data processing alternative to the averaging method will be discussed. It is to extract evoked potentials only from two segments. The theoretical basis of this procedure is the so-called ARMA model which gives a high frequency resolution of a periodic signal mixed with noise in a relatively low signal-to-noise ratio. The method is tested by simulation studies. The applicability will be demonstrated by clinical examples.
Additional details
Identifiers
- OpenAlex
- W2412205258
- PMID
- 6727687
- URL
- http://www.thieme-connect.de/DOI/DOI?10.1055/s-0038-1635318
Dates
- Issued
-
January 1984
Citations
- Guberek, T., & Hedstrom, M. (2017). On or off the record? Detecting patterns of silence about death in Guatemala’s National Police Archive. Archival Science, 17(1), 27–54. https://doi.org/10.1007/s10502-017-9274-3
- https://doi.org/10.1109/iecon.2009.5415104
- https://doi.org/10.1109/icelie.2006.347188
- https://doi.org/10.1103/physreve.69.051909
- Müller, T., Ball, T., Kristeva-Feige, R., Mergner, T., & Timmer, J. (2000). Selecting relevant electrode positions for classification tasks based on the electro-encephalogram. Medical & Biological Engineering & Computing, 38(1), 62–67. https://doi.org/10.1007/bf02344690
- Effern, A., Lehnertz, K., Schreiber, T., Grunwald, T., David, P., & Elger, C. E. (2000). Nonlinear denoising of transient signals with application to event-related potentials. Physica D: Nonlinear Phenomena, 140(3-4), 257–266. https://doi.org/10.1016/s1386-9477(00)00111-9
- Effern, A., Lehnertz, K., Fernández, G., Grunwald, T., David, P., & Elger, C. E. (2000). Single trial analysis of event related potentials: non-linear de-noising with wavelets. Clinical Neurophysiology, 111(12), 2255–2263. https://doi.org/10.1016/s1388-2457(00)00463-6
- https://doi.org/10.1109/10.771199
- Krieger, S., Timmer, J., Lis, S., & Olbrich, H. M. (1995). Some considerations on estimating event-related brain signals. Journal of Neural Transmission, 99(1-3), 103–129. https://doi.org/10.1007/bf01271473
- https://doi.org/10.1109/10.301728
- https://doi.org/10.1109/10.204772
- Bartnik, E. A., Blinowska, K. J., & Durka, P. J. (1992). Single evoked potential reconstruction by means of wavelet transform. Biological Cybernetics, 67(2), 175–181. https://doi.org/10.1007/bf00201024
- Bartnik, E. A., & Blinowska, K. J. (1992). Wavelets—new method of evoked potential analysis. Medical & Biological Engineering & Computing, 30(1), 125–126. https://doi.org/10.1007/bf02446208
- Doncarli, C., Goerig, L., & Guiheneuc, P. (1992). Adaptive smoothing of evoked potentials. Signal Processing, 28(1), 63–76. https://doi.org/10.1016/0165-1684(92)90065-5
- Thakor, N. V., Vaz, C. A., McPherson, R. W., & Hanley, D. F. (1991). Adaptive Fourier series modeling of time-varying evoked potentials: study of human somatosensory evoked response to etomidate anesthetic. Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section, 80(2), 108–118. https://doi.org/10.1016/0168-5597(91)90148-q
- Wright, J. J., Kydd, R. R., & Sergejew, A. A. (1990). Autoregression models of EEG: Results compared with expectations for a multilinear near-equilibrium biophysical process. Biological Cybernetics, 62(3), 201–210. https://doi.org/10.1007/bf00198095
- https://doi.org/10.1109/10.18751
- https://doi.org/10.1109/iembs.1988.94808
- https://doi.org/10.1109/iembs.1988.95292
- Cerutti, S., Baselli, G., Liberati, D., & Pavesi, G. (1987). Single sweep analysis of visual evoked potentials through a model of parametric identification. Biological Cybernetics, 56(2-3), 111–120. https://doi.org/10.1007/bf00317986