Automated tracing of myelinated axons and detection of the nodes of Ranvier in serial images of peripheral nerves
Authors/Creators
-
1.
Heidelberg University
- 2. Heidelberg Collaboratory for Image Processing (HCI) Interdisciplinary Center for Scientific Computing (IWR), University of Heidelberg Heidelberg Germany
-
3.
University Medical Center Freiburg
-
4.
University of Freiburg
-
5.
Friedrich Miescher Institute
-
6.
Medizinische Hochschule Hannover
Description
SummaryThe development of realistic neuroanatomical models of peripheral nerves for simulation purposes requires the reconstruction of the morphology of the myelinated fibres in the nerve, including their nodes of Ranvier. Currently, this information has to be extracted by semimanual procedures, which severely limit the scalability of the experiments.In this contribution, we propose a supervised machine learning approach for the detailed reconstruction of the geometry of fibres inside a peripheral nerve based on its high‐resolution serial section images. Learning from sparse expert annotations, the algorithm traces myelinated axons, even across the nodes of Ranvier. The latter are detected automatically.The approach is based on classifying the myelinated membranes in a supervised fashion, closing the membrane gaps by solving an assignment problem, and classifying the closed gaps for the nodes of Ranvier detection.The algorithm has been validated on two very different datasets: (i) rat vagus nerve subvolume, SBFSEM microscope, 200 × 200 × 200 nm resolution, (ii) rat sensory branch subvolume, confocal microscope, 384 × 384 × 800 nm resolution. For the first dataset, the algorithm correctly reconstructed 88% of the axons (241 out of 273) and achieved 92% accuracy on the task of Ranvier node detection. For the second dataset, the gap closing algorithm correctly closed 96.2% of the gaps, and 55% of axons were reconstructed correctly through the whole volume. On both datasets, training the algorithm on a small data subset and applying it to the full dataset takes a fraction of the time required by the currently used semiautomated protocols. Our software, raw data and ground truth annotations are available at http://hci.iwr.uni‐heidelberg.de/Benchmarks/. The development version of the code can be found at https://github.com/RWalecki/ATMA.
Additional details
Identifiers
- OpenAlex
- W1573650944
- PMID
- 26191646
- URL
- https://onlinelibrary.wiley.com/doi/10.1111/jmi.12266
Funding
- Familie-Mehdorn-Stiftung
Dates
- Issued
-
June 12, 2015
References
- Andres, B., Koethe, U., Kroeger, T., Helmstaedter, M., Briggman, K. L., Denk, W., & Hamprecht, F. A. (2012). 3D segmentation of SBFSEM images of neuropil by a graphical model over supervoxel boundaries. Medical Image Analysis, 16(4), 796–805. https://doi.org/10.1016/j.media.2011.11.004
- Globally optimal multi‐target tracking on a hexagonal lattice
- Auer, R. N. (1994). Automated nerve fibre size and myelin sheath measurement using microcomputer-based digital image analysis: theory, method and results. Journal of Neuroscience Methods, 51(2), 229–238. https://doi.org/10.1016/0165-0270(94)90015-9
- Berclaz, J., Fleuret, F., Turetken, E., & Fua, P. (2011). Multiple Object Tracking Using K-Shortest Paths Optimization. IEEE Transactions on Pattern Analysis and Machine Intelligence, 33(9), 1806–1819. https://doi.org/10.1109/tpami.2011.21
- Breiman, L. (2001). Random Forests. Machine Learning, 45(1), 5–32. https://doi.org/10.1023/a:1010933404324
- Cardona, A., Saalfeld, S., Schindelin, J., Arganda-Carreras, I., Preibisch, S., Longair, M., Tomancak, P., Hartenstein, V., Douglas, R. J., & Samuel, A. (2012). TrakEM2 Software for Neural Circuit Reconstruction. PLoS ONE, 7(6), e38011. https://doi.org/10.1371/journal.pone.0038011
- Silva, A. P. D. da ., Jordão, C. E. R., & Fazan, V. P. S. (2007). Peripheral nerve morphometry: Comparison between manual and semi-automated methods in the analysis of a small nerve. Journal of Neuroscience Methods, 159(1), 153–157. https://doi.org/10.1016/j.jneumeth.2006.06.012
- Denk, W., Horstmann, H., & Kristen M. Harris. (2004). Serial Block-Face Scanning Electron Microscopy to Reconstruct Three-Dimensional Tissue Nanostructure. PLoS Biology, 2(11), e329. https://doi.org/10.1371/journal.pbio.0020329
- Optimal central nervous system preservation with glutaraldehyde perfusion for ultrastructural study [Article in Spanish]
- Multiscale vessel enhancement filtering
- Efficient automatic 3D‐reconstruction of branching neurons from EM data
- Candidate sampling for neuron reconstruction from anisotropic electron microscopy volumes
- Gierthmuehlen, M., Freiman, T. M., Haastert-Talini, K., Mueller, A., Kaminsky, J., Stieglitz, T., Plachta, D. T. T., & Gronenberg, W. (2013). Computational Tissue Volume Reconstruction of a Peripheral Nerve Using High-Resolution Light-Microscopy and Reconstruct. PLoS ONE, 8(6), e66191. https://doi.org/10.1371/journal.pone.0066191
- Gurobi Optimization(2013).Gurobi Optimizer Reference Manual. https://www.gurobi.com/documentation/6.0/refman/index.html
- Helmstaedter, M., Briggman, K. L., Turaga, S. C., Jain, V., Seung, H. S., & Denk, W. (2013). Connectomic reconstruction of the inner plexiform layer in the mouse retina. Nature, 500(7461), 168–174. https://doi.org/10.1038/nature12346
- Hosni, A., Rhemann, C., Bleyer, M., Rother, C., & Gelautz, M. (2013). Fast Cost-Volume Filtering for Visual Correspondence and Beyond. IEEE Transactions on Pattern Analysis and Machine Intelligence, 35(2), 504–511. https://doi.org/10.1109/tpami.2012.156
- Huelsenbeck, S. C., Rohrbeck, A., Handreck, A., Hellmich, G., Kiaei, E., Roettinger, I., Grothe, C., Just, I., & Haastert-Talini, K. (2012). C3 Peptide Promotes Axonal Regeneration and Functional Motor Recovery after Peripheral Nerve Injury. Neurotherapeutics, 9(1), 185–198. https://doi.org/10.1007/s13311-011-0072-y
- Hunter, D. A., Moradzadeh, A., Whitlock, E. L., Brenner, M. J., Myckatyn, T. M., Wei, C. H., Tung, T. H. H., & Mackinnon, S. E. (2007). Binary imaging analysis for comprehensive quantitative histomorphometry of peripheral nerve. Journal of Neuroscience Methods, 166(1), 116–124. https://doi.org/10.1016/j.jneumeth.2007.06.018
- Kaynig V. Vazquez‐Reina A. Knowles‐Barley S. et al. (2013).Large‐scale automatic reconstruction of neuronal processes from electron microscopy images. arXiv:1303.7186v1[q‐bio.NC].
- A formaldehyde‐glutaraldehyde fixative of high osmolarity for use in electron microscopy
- Online multi‐target tracking by large margin structured learning
- Koethe U.(2000).Generische Programmierung für die Bildverarbeitung Universität Hamburg Hamburg 2000 ISBN: 3‐8311‐0239‐2.
- Kreshuk, A., Straehle, C. N., Sommer, C., Koethe, U., Cantoni, M., Knott, G., Hamprecht, F. A., & Barnes, S. (2011). Automated Detection and Segmentation of Synaptic Contacts in Nearly Isotropic Serial Electron Microscopy Images. PLoS ONE, 6(10), e24899. https://doi.org/10.1371/journal.pone.0024899
- Kuhn, H. W. (1955). The Hungarian method for the assignment problem. Naval Research Logistics Quarterly, 2(1-2), 83–97. https://doi.org/10.1002/nav.3800020109
- Li, Q., Chen, Z., He, X., Wang, Y., Liu, H., & Xu, Q. (2012). Automatic identification and quantitative morphometry of unstained spinal nerve using molecular hyperspectral imaging technology. Neurochemistry International, 61(8), 1375–1384. https://doi.org/10.1016/j.neuint.2012.09.018
1–25 of 45
Citations
- Schadt, L. C., Ruhwedel, T., Pape, C., Sasmita, A. O., Steyer, A. M., & Möbius, W. (2024). Wrapped up: advancements in volume electron microscopy and application in myelin research. Methods in Microscopy, 1(2), 119–136. https://doi.org/10.1515/mim-2024-0013
- Ronchi, G., Fregnan, F., Muratori, L., Gambarotta, G., & Raimondo, S. (2023). Morphological Methods to Evaluate Peripheral Nerve Fiber Regeneration: A Comprehensive Review. International Journal of Molecular Sciences, 24(3), 1818. https://doi.org/10.3390/ijms24031818
- Plebani, E., Biscola, N. P., Havton, L. A., Rajwa, B., Shemonti, A. S., Jaffey, D., Powley, T., Keast, J. R., Lu, K.-H., & Dundar, M. M. (2022). High-throughput segmentation of unmyelinated axons by deep learning. Scientific Reports, 12(1). https://doi.org/10.1038/s41598-022-04854-3
- Kleinnijenhuis, M., Johnson, E., Mollink, J., Jbabdi, S., & Miller, K. L. (2020). A semi-automated approach to dense segmentation of 3D white matter electron microscopy. In bioRxiv. openRxiv. https://doi.org/10.1101/2020.03.19.979393
- Humbel, B. M., Schwarz, H., Tranfield, E. M., & Fleck, R. A. (2019, February 15). Chemical Fixation. In Biological Field Emission Scanning Electron Microscopy (1st ed., pp. 191–221). Wiley. https://doi.org/10.1002/9781118663233.ch10
- Lippens, S., Kremer, A., Borghgraef, P., & Guérin, C. J. (2019). Serial block face-scanning electron microscopy for volume electron microscopy. In Methods in Cell Biology (pp. 69–85). Elsevier. https://doi.org/10.1016/bs.mcb.2019.04.002
- Calì, C., Agus, M., Kare, K., Boges, D. J., Lehväslaiho, H., Hadwiger, M., & Magistretti, P. J. (2019). 3D cellular reconstruction of cortical glia and parenchymal morphometric analysis from Serial Block-Face Electron Microscopy of juvenile rat. Progress in Neurobiology, 183, 101696. https://doi.org/10.1016/j.pneurobio.2019.101696
- Smith, D., & Starborg, T. (2019). Serial block face scanning electron microscopy in cell biology: Applications and technology. Tissue and Cell, 57, 111–122. https://doi.org/10.1016/j.tice.2018.08.011
- Kizilyaprak, C., Stierhof, Y.-D., & Humbel, B. M. (2019). Volume microscopy in biology: FIB-SEM tomography. Tissue and Cell, 57, 123–128. https://doi.org/10.1016/j.tice.2018.09.006
- Xu, Y. K. T., Chitsaz, D., Brown, R. A., Cui, Q. L., Dabarno, M. A., Antel, J. P., & Kennedy, T. E. (2019). Deep learning for high-throughput quantification of oligodendrocyte ensheathment at single-cell resolution. Communications Biology, 2(1). https://doi.org/10.1038/s42003-019-0356-z
- Lai, J., Su, Y., Swain, D. L., Huang, D., Getchevski, D., & Gong, H. (2019). The Role of Schlemm's Canal Endothelium Cellular Connectivity in Giant Vacuole Formation: A 3D Electron Microscopy Study. Investigative Opthalmology & Visual Science, 60(5), 1630. https://doi.org/10.1167/iovs.18-26011
- Romero-Brey, I. (2018). 3D Electron Microscopy (EM) and Correlative Light Electron Microscopy (CLEM) Methods to Study Virus-Host Interactions. In Methods in Molecular Biology (pp. 213–236). Springer New York. https://doi.org/10.1007/978-1-4939-8678-1_11
- Shahbazi, A., Kinnison, J., Vescovi, R., Du, M., Hill, R., Joesch, M., Takeno, M., Zeng, H., da Costa, N. M., Grutzendler, J., Kasthuri, N., & Scheirer, W. J. (2018). Flexible Learning-Free Segmentation and Reconstruction of Neural Volumes. Scientific Reports, 8(1). https://doi.org/10.1038/s41598-018-32628-3
- Shahbazi, A., Kinnison, J., Vescovi, R., Du, M., Hill, R., Joesch, M., Takeno, M., Zeng, H., Costa, N. M. da ., Grutzendler, J., Kasthuri, N., & Scheirer, W. J. (2018). Flexible Learning-Free Segmentation and Reconstruction for Sparse Neuronal Circuit Tracing. In bioRxiv. openRxiv. https://doi.org/10.1101/278515
- Webb, R. I., & Schieber, N. L. (2017). Volume Scanning Electron Microscopy: Serial Block-Face Scanning Electron Microscopy Focussed Ion Beam Scanning Electron Microscopy. In Biological and Medical Physics, Biomedical Engineering (pp. 117–148). Springer International Publishing. https://doi.org/10.1007/978-3-319-68997-5_5
- Buhmann, J. M., Gerhard, S., Cook, M., & Funke, J. (2016). Tracking of microtubules in anisotropic volumes of neural tissue. 2016 IEEE 13th International Symposium on Biomedical Imaging (ISBI), 326–329. https://doi.org/10.1109/isbi.2016.7493275