Application of a customized 3D printed reduction aid after external fixation of the femur and tibia: Technical note
Description
AbstractBackgroundTo construct a fracture‐specific reduction aid by means of virtual reduction technology and 3D printing to reduce malreduced, externally fixed, long bone fractures.TechniqueFollowing application of an external fixator to a malreduced long bone fracture, we performed postoperative computed tomography to visualise the fragments and their position relative to Schanz screws. DICOM data were transferred to 3D planning software, and the fracture was then virtually reduced. Subsequently, a reduction aid was designed to cover the Schanz screws in such a way that it would maintain the position of the new fragments. Following 3D printing, the solid reduction aid could be applied onto the Schanz screws. The reduction aid fit only in the reduced position of the fracture, thus maintaining correct bone alignment.ConclusionOur reduction technique can be applied during the temporary external fixation period on the preexisting external fixator or as a reduction aid during definitive treatment.
Additional details
Identifiers
- OpenAlex
- W2581449804
- PMID
- 28120475
- URL
- https://onlinelibrary.wiley.com/doi/10.1002/rcs.1803
Dates
- Issued
-
January 25, 2017
References
- Rudloff, M. I., & Smith, W. R. (2009). Intramedullary Nailing of the Femur: Current Concepts Concerning Reaming. Journal of Orthopaedic Trauma, 23(Supplement 5), S12–S17. https://doi.org/10.1097/bot.0b013e31819f258a
- Winquist, R. A., Hansen, S. T., & Clawson, D. K. (1984). Closed intramedullary nailing of femoral fractures. A report of five hundred and twenty cases. The Journal of Bone & Joint Surgery, 66(4), 529–539. https://doi.org/10.2106/00004623-198466040-00006
- Ricci, W. M., Gallagher, B., & Haidukewych, G. J. (2009). Intramedullary Nailing of Femoral Shaft Fractures: Current Concepts. Journal of the American Academy of Orthopaedic Surgeons, 17(5), 296–305. https://doi.org/10.5435/00124635-200905000-00004
- Intramedullary nailing for tibial shaft fractures in adults
- Treatment of closed tibial fractures
- NOWOTARSKI, P. J., TUREN, C. H., BRUMBACK, R. J., & SCARBORO, J. M. (2000). Conversion of External Fixation to Intramedullary Nailing for Fractures of the Shaft of the Femur in Multiply Injured Patients*. The Journal of Bone and Joint Surgery-American Volume, 82(6), 781–788. https://doi.org/10.2106/00004623-200006000-00004
- Scalea, T. M., Boswell, S. A., Scott, J. D., Mitchell, K. A., Kramer, M. E., & Pollak, A. N. (2000). External Fixation as a Bridge to Intramedullary Nailing for Patients with Multiple Injuries and with Femur Fractures: Damage Control Orthopedics. The Journal of Trauma: Injury, Infection, and Critical Care, 48(4), 613–623. https://doi.org/10.1097/00005373-200004000-00006
- Horst, K., Andruszkow, H., Weber, C., Dienstknecht, T., Hildebrand, F., Tarkin, I., & Pape, H.-C. (2015). Standards of external fixation in prolonged applications to allow safe conversion to definitive extremity surgery: the Aachen algorithm for acute ex fix conversion. Injury, 46, S13–S18. https://doi.org/10.1016/s0020-1383(15)30005-x
- Pape, H.-C., Giannoudis, P., & Krettek, C. (2002). The timing of fracture treatment in polytrauma patients: relevance of damage control orthopedic surgery. The American Journal of Surgery, 183(6), 622–629. https://doi.org/10.1016/s0002-9610(02)00865-6
- Pape, H.-C., Hildebrand, F., Pertschy, S., Zelle, B., Garapati, R., Grimme, K., & Krettek, C. (2002). Changes in the Management of Femoral Shaft Fractures in Polytrauma Patients: From Early Total Care to Damage Control Orthopedic Surgery. The Journal of Trauma: Injury, Infection, and Critical Care, 53(3), 452–462. https://doi.org/10.1097/00005373-200209000-00010
- Hildebrand, F., Giannoudis, P., Kretteck, C., & Pape, H.-C. (2004). Damage control: extremities. Injury, 35(7), 678–689. https://doi.org/10.1016/j.injury.2004.03.004
- Pairon, P., Ossendorf, C., Kuhn, S., Hofmann, A., & Rommens, P. M. (2014). Intramedullary nailing after external fixation of the femur and tibia: a review of advantages and limits. European Journal of Trauma and Emergency Surgery, 41(1), 25–38. https://doi.org/10.1007/s00068-014-0448-x
- Dougherty, P. J., Silverton, C., Yeni, Y., Tashman, S., & Weir, R. (2006). Conversion From Temporary External Fixation to Definitive Fixation: Shaft Fractures. Journal of the American Academy of Orthopaedic Surgeons, 14(Supplement), S124–S127. https://doi.org/10.5435/00124635-200600001-00028
- Della Rocca, G. J., & Crist, B. D. (2006). External Fixation Versus Conversion to Intramedullary Nailing for Definitive Management of Closed Fractures of the Femoral and Tibial Shaft. Journal of the American Academy of Orthopaedic Surgeons, 14(Supplement), S131–S135. https://doi.org/10.5435/00124635-200600001-00030
- Liodakis, E., Kenawey, M., Petri, M., Zümrüt, A., Hawi, N., Krettek, C., & Citak, M. (2011). Factors influencing neck anteversion during femoral nailing: A retrospective analysis of 220 torsion-difference CTs. Injury, 42(11), 1342–1345. https://doi.org/10.1016/j.injury.2011.06.004
- Sigurdsen, U., Reikeras, O., & Utvag, S. E. (2010). The Effect of timing of conversion from external fixation to secondary intramedullary nailing in experimental tibial fractures. Journal of Orthopaedic Research, 29(1), 126–130. https://doi.org/10.1002/jor.21182
- McGraw, J. M., & Lim, E. V. (1988). Treatment of open tibial-shaft fractures. External fixation and secondary intramedullary nailing. The Journal of Bone & Joint Surgery, 70(6), 900–911. https://doi.org/10.2106/00004623-198870060-00015
- Gosling, T., Hufner, T., Westphal, R., Faulstich, J., Hankemeier, S., Wahl, F., & Krettek, C. (2006). Overdistraction of the Fracture Eases Reduction in Delayed Femoral Nailing: Results of Intraoperative Force Measurements. The Journal of Trauma: Injury, Infection, and Critical Care, 61(4), 900–904. https://doi.org/10.1097/01.ta.0000197431.05396.27
- Omar, M., Suero, E. M., Hawi, N., Decker, S., Krettek, C., & Citak, M. (2015). Preoperative virtual reduction reduces femoral malrotation in the treatment of bilateral femoral shaft fractures. Archives of Orthopaedic and Trauma Surgery, 135(10), 1385–1389. https://doi.org/10.1007/s00402-015-2285-8
- Suero, E. M., Hüfner, T., Stübig, T., Krettek, C., & Citak, M. (2010). Use of a virtual 3D software for planning of tibial plateau fracture reconstruction. Injury, 41(6), 589–591. https://doi.org/10.1016/j.injury.2009.10.053
- Citak, M., Oszwald, M., O’Loughlin, P. F., Citak, M., Kendoff, D., Hüfner, T., & Krettek, C. (2009). Three-dimensional measurement of femoral antetorsion: comparison to a conventional radiological method. Archives of Orthopaedic and Trauma Surgery, 130(4), 513–518. https://doi.org/10.1007/s00402-009-0923-8
- Stübig, T., Min, W., Arvani, M., Hawi, N., Krettek, C., & Citak, M. (2011). Accuracy of measurement of femoral anteversion in femoral shaft fractures using a computer imaging software: a cadaveric study. Archives of Orthopaedic and Trauma Surgery, 132(5), 613–616. https://doi.org/10.1007/s00402-011-1450-y
- Jaarsma, R. L., Pakvis, D. F. M., Verdonschot, N., Biert, J., & van Kampen, A. (2004). Rotational Malalignment After Intramedullary Nailing of Femoral Fractures. Journal of Orthopaedic Trauma, 18(7), 403–409. https://doi.org/10.1097/00005131-200408000-00002
Citations
- MacFadden, L. N., Adams, L. W., Boerhave, C., O'Connor, H. A., VanDerWolde, B. K., & Skelley, N. W. (2024). Mechanical Analysis of a Novel 3D-printed External Fixator Design Versus Industry-standard External Fixators. Journal of the American Academy of Orthopaedic Surgeons, 32(7), e331–e345. https://doi.org/10.5435/jaaos-d-23-00926
- O'Connor, H. A., Adams, L. W., MacFadden, L. N., & Skelley, N. W. (2023). 3D Printed Orthopaedic External Fixation Devices: A Systematic Review. 3D Printing in Medicine, 9(1). https://doi.org/10.1186/s41205-023-00180-0
- Wu, J., Zhou, P., Zhang, Y., Xiao, L., Li, L., & Xu, S. (2021). A new technology using a customized 3D printed fixator to assist fracture reduction and fixation: Technical note. The International Journal of Medical Robotics and Computer Assisted Surgery, 17(4). https://doi.org/10.1002/rcs.2270
- Yang, S., Lin, H., & Luo, C. (2021). Meta-Analysis of 3D Printing Applications in Traumatic Fractures. Frontiers in Surgery, 8. https://doi.org/10.3389/fsurg.2021.696391
- Swartman, B., Franke, J., Schnurr, C., Märdian, S., Willy, C., DGOU, A. D. der ., DGU, A. der ., & Back, D. A. (2020). Digitaler OP. Der Unfallchirurg, 123(11), 849–855. https://doi.org/10.1007/s00113-020-00886-4
- Zeller, A. N., Neuhaus, M. T., Weissbach, L. V. M., Rana, M., Dhawan, A., Eckstein, F. M., Gellrich, N. C., & Zimmerer, R. M. (2020). Patient-Specific Mandibular Reconstruction Plates Increase Accuracy and Long-Term Stability in Immediate Alloplastic Reconstruction of Segmental Mandibular Defects. Journal of Maxillofacial and Oral Surgery, 19(4), 609–615. https://doi.org/10.1007/s12663-019-01323-9
- Chu, Y.-L., Chen, C.-K., Liu, Y.-C., Lu, T.-W., & Liaw, C.-K. (2020). Geometrical analysis for assessing torsional alignment of humerus. BMC Musculoskeletal Disorders, 21(1). https://doi.org/10.1186/s12891-020-3118-7
- Braun, B. J., Grimm, B., Hanflik, A. M., Marmor, M. T., Richter, P. H., Sands, A. K., & Sivananthan, S. (2020). Finding NEEMO: towards organizing smart digital solutions in orthopaedic trauma surgery. EFORT Open Reviews, 5(7), 408–420. https://doi.org/10.1302/2058-5241.5.200021
- Bruns, N., & Krettek, C. (2019). 3D-Druck in der Unfallchirurgie: Planung, Druck und Aufbereitung. Der Unfallchirurg, 122(4), 270–277. https://doi.org/10.1007/s00113-019-0625-9
- Liodakis, E., Bruns, N., Macke, C., Krettek, C., & Omar, M. (2019). 3D-Druck-Template-gestützte Reposition von Frakturen der langen Röhrenknochen. Der Unfallchirurg, 122(4), 286–292. https://doi.org/10.1007/s00113-019-0627-7
- Krettek, C., & Bruns, N. (2019). Aktueller Stand und neue Entwicklungen des 3D-Drucks in der Unfallchirurgie. Der Unfallchirurg, 122(4), 256–269. https://doi.org/10.1007/s00113-019-0636-6
- Wang, Q., Hu, J., Guan, J., Chen, Y., & Wang, L. (2018). Proximal third humeral shaft fractures fixed with long helical PHILOS plates in elderly patients: benefit of pre-contouring plates on a 3D-printed model—a retrospective study. Journal of Orthopaedic Surgery and Research, 13(1). https://doi.org/10.1186/s13018-018-0908-9
- Printing, R. S. I. G. for . 3D ., Chepelev, L., Wake, N., Ryan, J., Althobaity, W., Gupta, A., Arribas, E., Santiago, L., Ballard, D. H., Wang, K. C., Weadock, W., Ionita, C. N., Mitsouras, D., Morris, J., Matsumoto, J., Christensen, A., Liacouras, P., Rybicki, F. J., & Sheikh, A. (2018). Radiological Society of North America (RSNA) 3D printing Special Interest Group (SIG): guidelines for medical 3D printing and appropriateness for clinical scenarios. 3D Printing in Medicine, 4(1). https://doi.org/10.1186/s41205-018-0030-y
- Rankin, T. M., Wormer, B. A., Miller, J. D., Giovinco, N. A., Al Kassis, S., & Armstrong, D. G. (2018). Image once, print thrice? Three-dimensional printing of replacement parts. The British Journal of Radiology, 91(1083). https://doi.org/10.1259/bjr.20170374