Relations Between Scalar Shift and Insertion Depth in Human Cochlear Implantation
Description
Objective: The intracochlear position of an electrode array may influence the outcome after cochlear implantation. The design of the electrode array can increase the risk of trauma causing penetration of the basilar membrane or shift of the electrode array into the scala vestibuli. The aim of the present study was to identify a scalar shift after implantation of two different electrode arrays developed by one manufacturer. Study Design: Retrospective analysis. Setting: Tertiary referral center. Patients and Intervention: Cochlear implant recipients implanted between 2010 and 2014 and receiving either a mid-scala (n = 30) or a perimodiolar (n = 30) electrode array. Main Outcome Measure: Occurrence of scalar shift in association with the electrode type. Results: Scalar shift occurred in 26.7% (8 of 30) of the patients implanted with a perimodiolar electrode array and in 6.7% (2 of 30) of the patients implanted with the mid-scala electrode array. The mean insertion depth in the patients experiencing scalar shift after implantation of the mid-scala electrode was much deeper (21.59 ± 0.34 mm) when compared with the mean insertion depth of the patients with scalar shift after implantation with a perimodiolar electrode array (17.85 ± 2.19 mm). There tends to be a correlation between the cochlear length and the occurrence of a scalar shift. However, the number of patients with scalar shift in the mid-scala group is rather small. Conclusion: Based on the presented data, more patients implanted with a perimodiolar electrode array have a scalar shift when compared with the midscalar electrode array.
Additional details
Identifiers
- OpenAlex
- W2990768848
- PMID
- 31789806
- URL
- https://journals.lww.com/10.1097/MAO.0000000000002460
Dates
- Issued
-
February 2020
References
- Wilson, B. S., & Dorman, M. F. (2008). Cochlear implants: A remarkable past and a brilliant future. Hearing Research, 242(1-2), 3–21. https://doi.org/10.1016/j.heares.2008.06.005
- Finley, C. C., Holden, T. A., Holden, L. K., Whiting, B. R., Chole, R. A., Neely, G. J., Hullar, T. E., & Skinner, M. W. (2008). Role of Electrode Placement as a Contributor to Variability in Cochlear Implant Outcomes. Otology & Neurotology, 29(7), 920–928. https://doi.org/10.1097/mao.0b013e318184f492
- Aschendorff, A., Kromeier, J., Klenzner, T., & Laszig, R. (2007). Quality Control After Insertion of the Nucleus Contour and Contour Advance Electrode in Adults. Ear & Hearing, 28(2), 75S–79S. https://doi.org/10.1097/aud.0b013e318031542e
- Nordfalk, K. F., Rasmussen, K., Hopp, E., Greisiger, R., & Jablonski, G. E. (2013). Scalar position in cochlear implant surgery and outcome in residual hearing and the vestibular system. International Journal of Audiology, 53(2), 121–127. https://doi.org/10.3109/14992027.2013.854413
- Pfingst, B. E., Hughes, A. P., Colesa, D. J., Watts, M. M., Strahl, S. B., & Raphael, Y. (2015). Insertion trauma and recovery of function after cochlear implantation: Evidence from objective functional measures. Hearing Research, 330, 98–105. https://doi.org/10.1016/j.heares.2015.07.010
- Eshraghi, A. A., & Van De Water, T. R. (2006). Cochlear implantation trauma and noise‐induced hearing loss: Apoptosis and therapeutic strategies. The Anatomical Record Part A: Discoveries in Molecular, Cellular, and Evolutionary Biology, 288A(4), 473–481. https://doi.org/10.1002/ar.a.20305
- Chiesa Estomba, C. M., Rivera Schmitz, T., Betances Reinoso, F. A., Dominguez Collado, L., Estevez Garcia, M., & Lorenzo Lorenzo, A. I. (2017). Complications after cochlear implantation in adult patients. 10-Year retrospective analysis of a tertiary academic centre. Auris Nasus Larynx, 44(1), 40–45. https://doi.org/10.1016/j.anl.2016.03.012
- Quesnel, A. M., Nakajima, H. H., Rosowski, J. J., Hansen, M. R., Gantz, B. J., & Nadol, J. B. (2016). Delayed loss of hearing after hearing preservation cochlear implantation: Human temporal bone pathology and implications for etiology. Hearing Research, 333, 225–234. https://doi.org/10.1016/j.heares.2015.08.018
- Holden, L. K., Finley, C. C., Firszt, J. B., Holden, T. A., Brenner, C., Potts, L. G., Gotter, B. D., Vanderhoof, S. S., Mispagel, K., Heydebrand, G., & Skinner, M. W. (2013). Factors Affecting Open-Set Word Recognition in Adults With Cochlear Implants. Ear & Hearing, 34(3), 342–360. https://doi.org/10.1097/aud.0b013e3182741aa7
- Shepherd, R. K., Hatsushika, S., & Clark, G. M. (1993). Electrical stimulation of the auditory nerve: The effect of electrode position on neural excitation. Hearing Research, 66(1), 108–120. https://doi.org/10.1016/0378-5955(93)90265-3
- van der Beek, F. B., Boermans, P. P. B. M., Verbist, B. M., Briaire, J. J., & Frijns, J. H. M. (2005). Clinical Evaluation of the Clarion CII HiFocus 1 with and Without Positioner. Ear and Hearing, 26(6), 577–592. https://doi.org/10.1097/01.aud.0000188116.30954.21
- A. KAWANO, H. L. SELDON, G. M. CLAR. (1998). Intracochlear Factors Contributing to Psychophysical Percepts Following Cochlear Implantation. Acta Oto-Laryngologica, 118(3), 313–326. https://doi.org/10.1080/00016489850183386
- Saunders, E., Cohen, L., Aschendorff, A., Shapiro, W., Knight, M., Stecker, M., Richter, B., Waltzman, S., Tykocinski, M., Roland, T., Laszig, R., & Cowan, R. (2002). Threshold, Comfortable Level and Impedance Changes as a Function of Electrode-Modiolar Distance. Ear and Hearing, 23(Supplement), 28S–40S. https://doi.org/10.1097/00003446-200202001-00004
- Long, C. J., Holden, T. A., McClelland, G. H., Parkinson, W. S., Shelton, C., Kelsall, D. C., & Smith, Z. M. (2014). Examining the Electro-Neural Interface of Cochlear Implant Users Using Psychophysics, CT Scans, and Speech Understanding. Journal of the Association for Research in Otolaryngology, 15(2), 293–304. https://doi.org/10.1007/s10162-013-0437-5
- Huang, T. C., Reitzen, S. D., Marrinan, M. S., Waltzman, S. B., & Roland, J. T. (2006). Modiolar Coiling, Electrical Thresholds, and Speech Perception after Cochlear Implantation Using the Nucleus Contour Advance Electrode with the Advance Off Stylet Technique. Otology & Neurotology, 27(2), 159–166. https://doi.org/10.1097/01.mao.0000187047.58544.d0
- Marrinan, M. S., Roland, J. T., Reitzen, S. D., Waltzman, S. B., Cohen, L. T., & Cohen, N. L. (2004). Degree of Modiolar Coiling, Electrical Thresholds, and Speech Perception After Cochlear Implantation. Otology & Neurotology, 25(3), 290–294. https://doi.org/10.1097/00129492-200405000-00015
- van der Beek, F. B., Briaire, J. J., van der Marel, K. S., Verbist, B. M., & Frijns, J. H. M. (2016). Intracochlear Position of Cochlear Implants Determined Using CT Scanning versus Fitting Levels: Higher Threshold Levels at Basal Turn. Audiology and Neurotology, 21(1), 54–67. https://doi.org/10.1159/000442513
- Gstöttner, W., Pok, S.-M., Peters, S., Kiefer, J., & Adunka, O. (2005). Kochleaimplantat mit Tieftonrestgehörerhalt. HNO, 53(9), 784–791. https://doi.org/10.1007/s00106-004-1170-5
- Adunka, O., Gstoettner, W., Hambek, M., Unkelbach, M. H., Radeloff, A., & Kiefer, J. (2004). Preservation of Basal Inner Ear Structures in Cochlear Implantation. ORL, 66(6), 306–312. https://doi.org/10.1159/000081887
- O'Connell, B. P., Cakir, A., Hunter, J. B., Francis, D. O., Noble, J. H., Labadie, R. F., Zuniga, G., Dawant, B. M., Rivas, A., & Wanna, G. B. (2016). Electrode Location and Angular Insertion Depth Are Predictors of Audiologic Outcomes in Cochlear Implantation. Otology & Neurotology, 37(8), 1016–1023. https://doi.org/10.1097/mao.0000000000001125
- Zuniga, M. G., Rivas, A., Hedley-Williams, A., Gifford, R. H., Dwyer, R., Dawant, B. M., Sunderhaus, L. W., Hovis, K. L., Wanna, G. B., Noble, J. H., & Labadie, R. F. (2017). Tip Fold-over in Cochlear Implantation: Case Series. Otology & Neurotology, 38(2), 199–206. https://doi.org/10.1097/mao.0000000000001283
- Mittmann, P., Todt, I., Ernst, A., Rademacher, G., Mutze, S., Göricke, S., Schlamann, M., Ramalingam, R., Lang, S., Christov, F., & Arweiler-Harbeck, D. (2016). Electrophysiological detection of scalar changing perimodiolar cochlear electrode arrays: a long term follow-up study. European Archives of Oto-Rhino-Laryngology, 273(12), 4251–4256. https://doi.org/10.1007/s00405-016-4175-2
- Cuda, D., & Murri, A. (2017). Cochlear implantation with the nucleus slim modiolar electrode (CI532): a preliminary experience. European Archives of Oto-Rhino-Laryngology, 274(12), 4141–4148. https://doi.org/10.1007/s00405-017-4774-6
- van Wermeskerken, G. K. A., van Olphen, A. F., & Graamans, K. (2009). Imaging of electrode position in relation to electrode functioning after cochlear implantation. European Archives of Oto-Rhino-Laryngology, 266(10), 1527–1531. https://doi.org/10.1007/s00405-009-0939-2
- Ruivo, J., Mermuys, K., Bacher, K., Kuhweide, R., Offeciers, E., & Casselman, J. W. (2009). Cone Beam Computed Tomography, A Low-Dose Imaging Technique in the Postoperative Assessment of Cochlear Implantation. Otology & Neurotology, 30(3), 299–303. https://doi.org/10.1097/mao.0b013e31819679f9
1–25 of 46
Citations
- Mao, J., Huang, L., Chi, Z., Chen, M., Li, W., & Li, S. (2024). Impact of cochlear detailed morphology on insertion results and intracochlear trauma of a slim pre-curved electrode array: a micro-CT study. European Archives of Oto-Rhino-Laryngology, 282(4), 1769–1781. https://doi.org/10.1007/s00405-024-09058-1
- Franke-Trieger, A., Lailach, S., Strahl, S. B., Murrmann, K., Schebsdat, E., Neudert, M., & Zahnert, T. (2024). Voltage Matrix Algorithm for Intraoperative Detection of Cochlear Implant Electrode Misplacement. Audiology and Neurotology, 30(3), 252–262. https://doi.org/10.1159/000543264
- Hasan, Z., Key, S., Lee, M., & Da Cruz, M. (2023). Systematic Review of Intracochlear Measurements and Effect on Postoperative Auditory Outcomes after Cochlear Implant Surgery. Otology & Neurotology, 45(1), e1–e17. https://doi.org/10.1097/mao.0000000000004044
- Jwair, S., Versnel, H., Stokroos, R. J., & Thomeer, H. G. X. M. (2022). The effect of the surgical approach and cochlear implant electrode on the structural integrity of the cochlea in human temporal bones. Scientific Reports, 12(1). https://doi.org/10.1038/s41598-022-21399-7
- Knoll, R. M., Trakimas, D. R., Wu, M. J., Lubner, R. J., Nadol, J. B., Ishiyama, A., Santos, F., Jung, D. H., Remenschneider, A. K., & Kozin, E. D. (2022). Intracochlear New Fibro-Ossification and Neuronal Degeneration Following Cochlear Implant Electrode Translocation: Long-Term Histopathological Findings in Humans. Otology & Neurotology, 43(2), e153–e164. https://doi.org/10.1097/mao.0000000000003402
- Ramos de Miguel, Á., Riol Sancho, D., Falcón-González, J. C., Pavone, J., Rodríguez Herrera, L., Borkoski Barreiro, S., Falcón Benitez, N., & Ramos Macias, Á. (2022). Assessing the Placement of the Cochlear Slim Perimodiolar Electrode Array by Trans Impedance Matrix Analysis: A Temporal Bone Study. Journal of Clinical Medicine, 11(14), 3930. https://doi.org/10.3390/jcm11143930
- Ovari, A., Hühnlein, L., Nguyen-Dalinger, D., Strüder, D. F., Külkens, C., Niclaus, O., & Meyer, J. E. (2022). Functional Outcomes and Quality of Life after Cochlear Implantation in Patients with Long-Term Deafness. Journal of Clinical Medicine, 11(17), 5156. https://doi.org/10.3390/jcm11175156
- Avasarala, V. S., Jinka, S. K., & Jeyakumar, A. (2022). Complications of Cochleostomy Versus Round Window Surgical Approaches: A Systematic Review and Meta-Analysis. Cureus. https://doi.org/10.7759/cureus.25451
- Torres, R., Hochet, B., Daoudi, H., Carré, F., Mosnier, I., Sterkers, O., Ferrary, E., & Nguyen, Y. (2021). Atraumatic Insertion of a Cochlear Implant Pre-Curved Electrode Array by a Robot-Automated Alignment with the Coiling Direction of the Scala Tympani. Audiology and Neurotology, 27(2), 148–155. https://doi.org/10.1159/000517398
- Jwair, S., Prins, A., Wegner, I., Stokroos, R. J., Versnel, H., & Thomeer, H. G. X. M. (2020). Scalar Translocation Comparison Between Lateral Wall and Perimodiolar Cochlear Implant Arrays ‐ A Meta‐Analysis. The Laryngoscope, 131(6), 1358–1368. https://doi.org/10.1002/lary.29224