Published April 18, 2016 | Journal article | Version v1 | https://doi.org/10.1111/aor.12735

In Vitro Evaluation of Inflow Cannula Fixation Techniques in Left Ventricular Assist Device Surgery

Description

AbstractThe therapy of terminal heart failure with left ventricular assist devices has become a standard in cardiac surgery. Yet the surgical implantation technique is not standardized and differs from center to center. Complications associated with left ventricular assist device (LVAD) inflow cannula placement are thrombosis, suction events, and flow disturbances. Within this in vitro study we aimed to investigate if the fixation technique of the sewing ring has an impact on the position of the inflow cannula. For this in vitro study the HeartMate III LVAD (Thoratec Corporation, Pleasanton, CA, USA) was used. In five sessions, two approaches were considered for coring of the ventricle for LVAD inflow cannula insertion: "sew‐then‐core" and "core‐then‐sew." In the "sew‐then‐core" technique, the sewing cuff is first affixed to the heart, usually with 8–16 interrupted pledgeted mattress sutures. Subsequently, a cylindrical knife is used to resect a cylindrical core of myocardium to permit cannula insertion. In the "core‐then‐sew" technique, the sequence is reversed such that the knife is used before the suture ring is affixed. When the "sew‐then‐core" technique is used, the mattress sutures may be placed with full‐thickness bites that penetrate the endocardium (i.e., transmural stitching) or partial‐thickness bites that do not penetrate the endocardium (i.e., epicardial stitching). When the "core‐then‐sew" technique is used, the suture is passed fully into the ventricular lumen and fed back through the cored hole, at which point the needle may be reinserted into the freshly cored myocardium such that it exits the epicardium (i.e., transmural stitching with back stitch) or not (i.e., transmural stitching without back stitch). These four different sewing ring fixation suturing techniques were tested by experienced surgeons to affix the sewing ring: transmural stitching, epicardial stitching, transmural stitching with back stitch, and transmural stitching without back stitch. The sewing ring was sewed onto a silicone dummy designed to simulate the left ventricle with standard 2–0 Ethibond sutures (Ethicon, Somerville, NY, USA). Afterward, the dummies were measured and documented via photography. In addition, porcine hearts were used to simulate the suturing techniques in a physiological setting. The setting of the inflow cannula is substantially influenced by the fixation method of the sewing ring. Epicardial stitching showed the best results with stable cannula fixation, minimal gap around the cannula and no contact between the sutures and sewing ring with blood. The method of transmural stitching without back stitch showed the worst results by creating the biggest epithelial gap between inflow cannula and tissue as well as proving the biggest surface for blood contact between sewing ring and sutures. In general, both "sew‐then‐core" techniques resulted in a greater degree of apposition between the cuff and epicardial tissue. Within the study we revealed that the surgical fixation of the sewing ring has a significant impact on the inflow cannula stability, position, and tissue apposition in LVAD implantation surgery. Epicardial stitching of the sewing ring provides the best results in order to prevent suction events as well as thrombosis formation.

Additional details

Dates

Issued
April 18, 2016

References

  1. Slaughter, M. S., Rogers, J. G., Milano, C. A., Russell, S. D., Conte, J. V., Feldman, D., Sun, B., Tatooles, A. J., Delgado, R. M., Long, J. W., Wozniak, T. C., Ghumman, W., Farrar, D. J., & Frazier, O. H. (2009). Advanced Heart Failure Treated with Continuous-Flow Left Ventricular Assist Device. New England Journal of Medicine, 361(23), 2241–2251. https://doi.org/10.1056/nejmoa0909938
  2. Rose, E. A., Gelijns, A. C., Moskowitz, A. J., Heitjan, D. F., Stevenson, L. W., Dembitsky, W., Long, J. W., Ascheim, D. D., Tierney, A. R., Levitan, R. G., Watson, J. T., Ronan, N. S., Shapiro, P. A., Lazar, R. M., Miller, L. W., Gupta, L., Frazier, O. H., Desvigne-Nickens, P., Oz, M. C., … Meier, P. (2001). Long-Term Use of a Left Ventricular Assist Device for End-Stage Heart Failure. New England Journal of Medicine, 345(20), 1435–1443. https://doi.org/10.1056/nejmoa012175
  3. Strueber, M., Larbalestier, R., Jansz, P., Zimpfer, D., Fiane, A. E., Tsui, S., Simon, A., Schmitto, J. D., Khaghani, A., Wieselthaler, G. M., Najarian, K., & Schueler, S. (2014). Results of the post-market Registry to Evaluate the HeartWare Left Ventricular Assist System (ReVOLVE). The Journal of Heart and Lung Transplantation, 33(5), 486–491. https://doi.org/10.1016/j.healun.2014.01.856
  4. Some thoughts about the historic events that led to the first clinical implantation of a total artificial heart
  5. Schmitto, J. D., Molitoris, U., Haverich, A., & Strueber, M. (2012). Implantation of a centrifugal pump as a left ventricular assist device through a novel, minimized approach: Upper hemisternotomy combined with anterolateral thoracotomy. The Journal of Thoracic and Cardiovascular Surgery, 143(2), 511–513. https://doi.org/10.1016/j.jtcvs.2011.07.046
  6. Kirklin, J. K., Naftel, D. C., Kormos, R. L., Pagani, F. D., Myers, S. L., Stevenson, L. W., Acker, M. A., Goldstein, D. L., Silvestry, S. C., Milano, C. A., Baldwin, J. T., Pinney, S., Eduardo Rame, J., & Miller, M. A. (2014). Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) analysis of pump thrombosis in the HeartMate II left ventricular assist device. The Journal of Heart and Lung Transplantation, 33(1), 12–22. https://doi.org/10.1016/j.healun.2013.11.001
  7. Increase in Left Ventricular Assist Device Thrombosis. (2014). Increase in Left Ventricular Assist Device Thrombosis. New England Journal of Medicine, 370(15), 1463–1466. https://doi.org/10.1056/nejmc1401768
  8. Hanke, J., Rojas, S., Avsar, M., Haverich, A., & Schmitto, J. (2015). Minimally-invasive LVAD Implantation: State of the Art. Current Cardiology Reviews, 11(3), 246–251. https://doi.org/10.2174/1573403x1103150514151750
  9. Netuka, I., Sood, P., Pya, Y., Zimpfer, D., Krabatsch, T., Garbade, J., Rao, V., Morshuis, M., Marasco, S., Beyersdorf, F., Damme, L., & Schmitto, J. D. (2015). Fully Magnetically Levitated Left Ventricular Assist System for Treating Advanced HF. Journal of the American College of Cardiology, 66(23), 2579–2589. https://doi.org/10.1016/j.jacc.2015.09.083

Citations

  1. Li, Y., Xi, Y., Wang, X., & Chen, Z. (2025). Mathematical model for qualitative assessment of blood pump-induced thrombosis and stroke risk. Acta Mechanica Sinica, 42(7). https://doi.org/10.1007/s10409-024-24616-x
  2. Li, Y., Wang, H., Liu, X., Xi, Y., Sun, A., Wang, L., Deng, X., Chen, Z., & Fan, Y. (2024). Comprehensive study on simulation, performance evaluation and optimization strategies for blood pumps. Engineering Applications of Computational Fluid Mechanics, 18(1). https://doi.org/10.1080/19942060.2024.2369690
  3. Kikoïne, J., Nowacka, A., Schukraft, S., Abdurashidova, T., Yerly, P., Tozzi, P., Ltaief, Z., Rosner, L., Hullin, R., & Kirsch, M. (2024). Clinical outcomes of HeartMate 3 left ventricular assist device support with a Bridge to Transplant vs a Destination Therapy strategy: a single-centre retrospective cohort. Swiss Medical Weekly, 154(7), 3529. https://doi.org/10.57187/s.3529
  4. Dimitrov, K., & Zimpfer, D. (2024). Exploring Standard and Alternative Sites for Left Ventricular Assist Device Inflow Cannula and Outflow Graft Placement. In Cardiology and Cardiovascular Medicine. IntechOpen. https://doi.org/10.5772/intechopen.114053
  5. Mariani, S., Bounader, K., & Schmitto, J. D. (2023, September 8). Incisions and Decisions: Implantation Technique for DurableLVADs. In Textbook of Transplantation and Mechanical Support for End‐Stage Heart and Lung Disease (1st ed., pp. 734–746). Wiley. https://doi.org/10.1002/9781119633884.ch53
  6. Peev, M. P., & Salerno, C. T. (2023). HeartMate 3. In Mechanical Circulatory Support (pp. 1–18). Springer International Publishing. https://doi.org/10.1007/978-3-030-86172-8_9-1
  7. Gordon, J. S., Blazoski, C. M., Wood, C. T., Zuber, C., Massey, H. T., Throckmorton, A., & Tchantchaleishvili, V. (2022). Mechanical and interventional support for heart failure with preserved ejection fraction: A review. Artificial Organs, 46(11), 2109–2117. https://doi.org/10.1111/aor.14275
  8. Malone, G., Abdelsayed, G., Bligh, F., Al Qattan, F., Syed, S., Varatharajullu, P., Msellati, A., Mwipatayi, D., Azhar, M., Malone, A., Fatimi, S. H., Conway, C., & Hameed, A. (2022). Advancements in left ventricular assist devices to prevent pump thrombosis and blood coagulopathy. Journal of Anatomy, 242(1), 29–49. https://doi.org/10.1111/joa.13675
  9. Motomura, T. (2020). EVAHEART 2 Left Ventricular Assist System: A Hemocompatible Centrifugal Pump with Physiological Pulsatility. In Mechanical Support for Heart Failure (pp. 535–544). Springer International Publishing. https://doi.org/10.1007/978-3-030-47809-4_32
  10. Nowacka, A., Hullin, R., Tozzi, P., Barras, N., Regamey, J., Yerly, P., Rosner, L., Marcucci, C., Rusca, M., Liaudet, L., & Kirsch, M. (2020). Short-term single-centre experience with the HeartMate 3 left ventricular assist device for advanced heart failure. European Journal of Cardio-Thoracic Surgery, 58(3), 511–518. https://doi.org/10.1093/ejcts/ezaa075
  11. Potapov, E. V., Antonides, C., Crespo-Leiro, M. G., Combes, A., Färber, G., Hannan, M. M., Kukucka, M., de Jonge, N., Loforte, A., Lund, L. H., Mohacsi, P., Morshuis, M., Netuka, I., Özbaran, M., Pappalardo, F., Scandroglio, A. M., Schweiger, M., Tsui, S., Zimpfer, D., & Gustafsson, F. (2019). 2019 EACTS Expert Consensus on long-term mechanical circulatory support. European Journal of Cardio-Thoracic Surgery, 56(2), 230–270. https://doi.org/10.1093/ejcts/ezz098
  12. Motomura, T., Tuzun, E., Yamazaki, K., Tatsumi, E., Benkowski, R., & Yamazaki, S. (2019). Preclinical Evaluation of the EVAHEART 2 Centrifugal Left Ventricular Assist Device in Bovines. ASAIO Journal, 65(8), 845–854. https://doi.org/10.1097/mat.0000000000000869
  13. Motomura, T., & Kelly, B. (2019). Surgical Techniques for Implanting the EVAHEART 2 Double Cuff Tipless Inflow Cannula. ASAIO Journal, 65(8), e86–e89. https://doi.org/10.1097/mat.0000000000000914
  14. Lanfear, A. T., Hamandi, M., Fan, J., DiMaio, J. M., & George, T. J. (2019). Trends in HeartMate 3: What we know so far. Journal of Cardiac Surgery, 35(1), 180–187. https://doi.org/10.1111/jocs.14319
  15. Malchesky, P. S. (2018). Artificial Organs 2017: A Year in Review. Artificial Organs, 42(3), 305–331. https://doi.org/10.1111/aor.13137