Dispersed Hydrogel Actuator for Modiolar Hugging Cochlear Implant Electrode Arrays
Additional details
Identifiers
- OpenAlex
- W2345144831
- PMID
- 26863644
- URL
- http://ieeexplore.ieee.org/document/7397973/
Funding
-
Deutsche Forschungsgemeinschaft
- Cluster of Excellence "Hearing4All" and Lower Austria Life Science
- LS 010-017
Dates
- Issued
-
November 2016
References
- Stieghorst, J., Bondarenkova, A., Burblies, N., Behrens, P., & Doll, T. (2015). 3D silicone rubber interfaces for individually tailored implants. Biomedical Microdevices, 17(3), Article 54. https://doi.org/10.1007/s10544-015-9960-y
- Lenarz, T. (2009). Funktionsersatz des Innenohres. In Medizintechnik (pp. 1933–1949). Springer Berlin Heidelberg. https://doi.org/10.1007/978-3-540-93936-8_83
- St??ver, T., Issing, P., Graurock, G., Erfurt, P., ElBeltagy, Y., Paasche, G., & Lenarz, T. (2005). Evaluation of the Advance Off-Stylet Insertion Technique and the Cochlear Insertion Tool in Temporal Bones. Otology & Neurotology, 26(6), 1161–1170. https://doi.org/10.1097/01.mao.0000179527.17285.85
- Tegtmeier, K., Aliuos, P., Stieghorst, J., Schickedanz, M., Golly, F., Zernetsch, H., Glasmacher, B., & Doll, T. (2014). Aligned carbon nanotube‐liquid silicone rubber conductors and electrode surfaces for stimulating medical implants. Physica Status Solidi (a), 211(6), 1439–1447. https://doi.org/10.1002/pssa.201330405
- Sidorenko, A., Krupenkin, T., Taylor, A., Fratzl, P., & Aizenberg, J. (2007). Reversible Switching of Hydrogel-Actuated Nanostructures into Complex Micropatterns. Science, 315(5811), 487–490. https://doi.org/10.1126/science.1135516
- Liu, Z., & Calvert, P. (2000). Multilayer Hydrogels as Muscle-Like Actuators. Advanced Materials, 12(4), 288–291. https://doi.org/10.1002/(sici)1521-4095(200002)12:4%3C288::aid-adma288%3E3.0.co;2-1
- Seldon, H. L., Dahm, M. C., Clark, G. M., & Crowe, S. (1994). Silastic with polyacrylic acid filler: swelling properties, biocompatibility and potential use in cochlear implants. Biomaterials, 15(14), 1161–1169. https://doi.org/10.1016/0142-9612(94)90237-2
- Mirzadeh, H., & Abbasi, F. (2003). Segmented detachable structure of cochlear‐implant electrodes for close‐hugging engagement with the modiolus. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 68B(2), 191–198. https://doi.org/10.1002/jbm.b.20011
- Stieghorst, J., Tegtmeier, K., Aliuos, P., Zernetsch, H., Glasmacher, B., & Doll, T. (2014). Self‐bending hydrogel actuation for electrode shafts in cochlear implants. Physica Status Solidi (a), 211(6), 1455–1461. https://doi.org/10.1002/pssa.201330404
- Christensen, L. H., Breiting, V. B., Aasted, A., Jørgensen, A., & Kebuladze, I. (2003). Long-Term Effects of Polyacrylamide Hydrogel on Human Breast Tissue. Plastic and Reconstructive Surgery, 111(6), 1883–1890. https://doi.org/10.1097/01.prs.0000056873.87165.5a
- Zarini, E., Supino, R., Pratesi, G., Laccabue, D., Tortoreto, M., Scanziani, E., Ghisleni, G., Paltrinieri, S., Tunesi, G., & Nava, M. (2004). Biocompatibility and Tissue Interactions of a New Filler Material for Medical Use. Plastic and Reconstructive Surgery, 114(4), 934–942. https://doi.org/10.1097/01.prs.0000133425.22598.d0
- Eshraghi, A. A., Yang, N. W., & Balkany, T. J. (2003). Comparative Study of Cochlear Damage With Three Perimodiolar Electrode Designs. The Laryngoscope, 113(3), 415–419. https://doi.org/10.1097/00005537-200303000-00005
- Fishman, K. E., Shannon, R. V., & Slattery, W. H. (1997). Speech Recognition as a Function of the Number of Electrodes Used in the SPEAK Cochlear Implant Speech Processor. Journal of Speech, Language, and Hearing Research, 40(5), 1201–1215. https://doi.org/10.1044/jslhr.4005.1201
- Rebscher, S. J. (2008). Considerations for design of future cochlear implant electrode arrays: Electrode array stiffness, size,. The Journal of Rehabilitation Research and Development, 45(5), 731–748. https://doi.org/10.1682/jrrd.2007.08.0119
- The use of electrophysical tests
- Cohen, L. T., Saunders, E., Knight, M. R., & Cowan, R. S. C. (2006). Psychophysical measures in patients fitted with Contour™ and straight Nucleus electrode arrays. Hearing Research, 212(1-2), 160–175. https://doi.org/10.1016/j.heares.2005.11.005
- Würfel, W., Lanfermann, H., Lenarz, T., & Majdani, O. (2014). Cochlear length determination using Cone Beam Computed Tomography in a clinical setting. Hearing Research, 316, 65–72. https://doi.org/10.1016/j.heares.2014.07.013
- Shepherd, R. K., Hatsushika, S., & Clark, G. M. (1993). Electrical stimulation of the auditory nerve: The effect of electrode position on neural excitation. Hearing Research, 66(1), 108–120. https://doi.org/10.1016/0378-5955(93)90265-3
- Wolfgang Karl Gstoettner, Oliver Ad. (2001). Perimodiolar Electrodes in Cochlear Implant Surgery. Acta Oto-Laryngologica, 121(2), 216–219. https://doi.org/10.1080/000164801300043569
- Marrinan, M. S., Roland, J. T., Reitzen, S. D., Waltzman, S. B., Cohen, L. T., & Cohen, N. L. (2004). Degree of Modiolar Coiling, Electrical Thresholds, and Speech Perception After Cochlear Implantation. Otology & Neurotology, 25(3), 290–294. https://doi.org/10.1097/00129492-200405000-00015
- Géléoc, G. S. G., & Holt, J. R. (2014). Sound Strategies for Hearing Restoration. Science, 344(6184). https://doi.org/10.1126/science.1241062
- Lenarz, T., Stöver, T., Buechner, A., Paasche, G., Briggs, R., Risi, F., Pesch, J., & Battmer, R.-D. (2006). Temporal Bone Results and Hearing Preservation with a New Straight Electrode. Audiology and Neurotology, 11(Suppl. 1), 34–41. https://doi.org/10.1159/000095612
- Clark, G. M., Hallwoeth, R. J., & Zdanius, K. (1975). A cochlear implant electrode. The Journal of Laryngology & Otology, 89(8), 787–792. https://doi.org/10.1017/s0022215100081020
- de Cássia Novaes, W., & Berg, A. (2003). Experiences with a New Nonbiodegradable Hydrogel (Aquamid): A Pilot Study. Aesthetic Plastic Surgery, 27(5), 376–380. https://doi.org/10.1007/s00266-003-2119-x
- Surface treatment of silicone rubber
1–25 of 30
Citations
- Kim, M., Cury, J., Kessler, L., Triplett, M., Sahota, S., Kampasi, K., Tan, X., Haque, R.-. ul ., & Richter, C.-P. (2024). Waveguides for neurostimulation in the cochlea. Frontiers in Audiology and Otology, 2. https://doi.org/10.3389/fauot.2024.1221778
- Terutsuki, D., Yoroizuka, H., Osawa, S., Ogihara, Y., Abe, H., Nakagawa, A., Iwasaki, M., & Nishizawa, M. (2022). Totally Organic Hydrogel‐Based Self‐Closing Cuff Electrode for Vagus Nerve Stimulation. Advanced Healthcare Materials, 11(23). https://doi.org/10.1002/adhm.202201627
- Yilmaz-Bayraktar, S., Foremny, K., Kreienmeyer, M., Warnecke, A., & Doll, T. (2022). Medical-Grade Silicone Rubber–Hydrogel-Composites for Modiolar Hugging Cochlear Implants. Polymers, 14(9), 1766. https://doi.org/10.3390/polym14091766
- Gomes, C. M., Liu, C., Paten, J. A., Felton, S. M., & Deravi, L. F. (2018). Protein‐Based Hydrogels that Actuate Self‐Folding Systems. Advanced Functional Materials, 29(4), Article 1805777. https://doi.org/10.1002/adfm.201805777
- Stieghorst, J., & Doll, T. (2018). Rheological behavior of PDMS silicone rubber for 3D printing of medical implants. Additive Manufacturing, 24, 217–223. https://doi.org/10.1016/j.addma.2018.10.004