Published November 2016 | Journal article | Version v1 | https://doi.org/10.1109/tbme.2016.2524663

Dispersed Hydrogel Actuator for Modiolar Hugging Cochlear Implant Electrode Arrays

Additional details

Funding

ROR icon Deutsche Forschungsgemeinschaft
Cluster of Excellence "Hearing4All" and Lower Austria Life Science
LS 010-017

Dates

Issued
November 2016

References

  1. Stieghorst, J., Bondarenkova, A., Burblies, N., Behrens, P., & Doll, T. (2015). 3D silicone rubber interfaces for individually tailored implants. Biomedical Microdevices, 17(3), Article 54. https://doi.org/10.1007/s10544-015-9960-y
  2. Lenarz, T. (2009). Funktionsersatz des Innenohres. In Medizintechnik (pp. 1933–1949). Springer Berlin Heidelberg. https://doi.org/10.1007/978-3-540-93936-8_83
  3. St??ver, T., Issing, P., Graurock, G., Erfurt, P., ElBeltagy, Y., Paasche, G., & Lenarz, T. (2005). Evaluation of the Advance Off-Stylet Insertion Technique and the Cochlear Insertion Tool in Temporal Bones. Otology & Neurotology, 26(6), 1161–1170. https://doi.org/10.1097/01.mao.0000179527.17285.85
  4. Tegtmeier, K., Aliuos, P., Stieghorst, J., Schickedanz, M., Golly, F., Zernetsch, H., Glasmacher, B., & Doll, T. (2014). Aligned carbon nanotube‐liquid silicone rubber conductors and electrode surfaces for stimulating medical implants. Physica Status Solidi (a), 211(6), 1439–1447. https://doi.org/10.1002/pssa.201330405
  5. Sidorenko, A., Krupenkin, T., Taylor, A., Fratzl, P., & Aizenberg, J. (2007). Reversible Switching of Hydrogel-Actuated Nanostructures into Complex Micropatterns. Science, 315(5811), 487–490. https://doi.org/10.1126/science.1135516
  6. Liu, Z., & Calvert, P. (2000). Multilayer Hydrogels as Muscle-Like Actuators. Advanced Materials, 12(4), 288–291. https://doi.org/10.1002/(sici)1521-4095(200002)12:4%3C288::aid-adma288%3E3.0.co;2-1
  7. Seldon, H. L., Dahm, M. C., Clark, G. M., & Crowe, S. (1994). Silastic with polyacrylic acid filler: swelling properties, biocompatibility and potential use in cochlear implants. Biomaterials, 15(14), 1161–1169. https://doi.org/10.1016/0142-9612(94)90237-2
  8. Mirzadeh, H., & Abbasi, F. (2003). Segmented detachable structure of cochlear‐implant electrodes for close‐hugging engagement with the modiolus. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 68B(2), 191–198. https://doi.org/10.1002/jbm.b.20011
  9. Stieghorst, J., Tegtmeier, K., Aliuos, P., Zernetsch, H., Glasmacher, B., & Doll, T. (2014). Self‐bending hydrogel actuation for electrode shafts in cochlear implants. Physica Status Solidi (a), 211(6), 1455–1461. https://doi.org/10.1002/pssa.201330404
  10. Christensen, L. H., Breiting, V. B., Aasted, A., Jørgensen, A., & Kebuladze, I. (2003). Long-Term Effects of Polyacrylamide Hydrogel on Human Breast Tissue. Plastic and Reconstructive Surgery, 111(6), 1883–1890. https://doi.org/10.1097/01.prs.0000056873.87165.5a
  11. Zarini, E., Supino, R., Pratesi, G., Laccabue, D., Tortoreto, M., Scanziani, E., Ghisleni, G., Paltrinieri, S., Tunesi, G., & Nava, M. (2004). Biocompatibility and Tissue Interactions of a New Filler Material for Medical Use. Plastic and Reconstructive Surgery, 114(4), 934–942. https://doi.org/10.1097/01.prs.0000133425.22598.d0
  12. Eshraghi, A. A., Yang, N. W., & Balkany, T. J. (2003). Comparative Study of Cochlear Damage With Three Perimodiolar Electrode Designs. The Laryngoscope, 113(3), 415–419. https://doi.org/10.1097/00005537-200303000-00005
  13. Fishman, K. E., Shannon, R. V., & Slattery, W. H. (1997). Speech Recognition as a Function of the Number of Electrodes Used in the SPEAK Cochlear Implant Speech Processor. Journal of Speech, Language, and Hearing Research, 40(5), 1201–1215. https://doi.org/10.1044/jslhr.4005.1201
  14. Rebscher, S. J. (2008). Considerations for design of future cochlear implant electrode arrays: Electrode array stiffness, size,. The Journal of Rehabilitation Research and Development, 45(5), 731–748. https://doi.org/10.1682/jrrd.2007.08.0119
  15. The use of electrophysical tests
  16. Cohen, L. T., Saunders, E., Knight, M. R., & Cowan, R. S. C. (2006). Psychophysical measures in patients fitted with Contour™ and straight Nucleus electrode arrays. Hearing Research, 212(1-2), 160–175. https://doi.org/10.1016/j.heares.2005.11.005
  17. Würfel, W., Lanfermann, H., Lenarz, T., & Majdani, O. (2014). Cochlear length determination using Cone Beam Computed Tomography in a clinical setting. Hearing Research, 316, 65–72. https://doi.org/10.1016/j.heares.2014.07.013
  18. Shepherd, R. K., Hatsushika, S., & Clark, G. M. (1993). Electrical stimulation of the auditory nerve: The effect of electrode position on neural excitation. Hearing Research, 66(1), 108–120. https://doi.org/10.1016/0378-5955(93)90265-3
  19. Wolfgang Karl Gstoettner, Oliver Ad. (2001). Perimodiolar Electrodes in Cochlear Implant Surgery. Acta Oto-Laryngologica, 121(2), 216–219. https://doi.org/10.1080/000164801300043569
  20. Marrinan, M. S., Roland, J. T., Reitzen, S. D., Waltzman, S. B., Cohen, L. T., & Cohen, N. L. (2004). Degree of Modiolar Coiling, Electrical Thresholds, and Speech Perception After Cochlear Implantation. Otology & Neurotology, 25(3), 290–294. https://doi.org/10.1097/00129492-200405000-00015
  21. Géléoc, G. S. G., & Holt, J. R. (2014). Sound Strategies for Hearing Restoration. Science, 344(6184). https://doi.org/10.1126/science.1241062
  22. Lenarz, T., Stöver, T., Buechner, A., Paasche, G., Briggs, R., Risi, F., Pesch, J., & Battmer, R.-D. (2006). Temporal Bone Results and Hearing Preservation with a New Straight Electrode. Audiology and Neurotology, 11(Suppl. 1), 34–41. https://doi.org/10.1159/000095612
  23. Clark, G. M., Hallwoeth, R. J., & Zdanius, K. (1975). A cochlear implant electrode. The Journal of Laryngology & Otology, 89(8), 787–792. https://doi.org/10.1017/s0022215100081020
  24. de Cássia Novaes, W., & Berg, A. (2003). Experiences with a New Nonbiodegradable Hydrogel (Aquamid): A Pilot Study. Aesthetic Plastic Surgery, 27(5), 376–380. https://doi.org/10.1007/s00266-003-2119-x
  25. Surface treatment of silicone rubber

1–25 of 30