Published January 1, 2013 | Journal article | Version v1 | https://doi.org/10.1515/bmt-2012-0047

In vivo degradation of magnesium alloy LA63 scaffolds for temporary stabilization of biological myocardial grafts in a swine model

Additional details

Dates

Issued
January 1, 2013

References

  1. Witte, F., Kaese, V., Haferkamp, H., Switzer, E., Meyer-Lindenberg, A., Wirth, C. J., & Windhagen, H. (2005). In vivo corrosion of four magnesium alloys and the associated bone response. Biomaterials, 26(17), 3557–3563. https://doi.org/10.1016/j.biomaterials.2004.09.049
  2. von In vivo assessment of the host reactions to the biodegradation of the two novel magnesium alloys AX in an animal model
  3. Seitz, J., Collier, K., Wulf, E., Bormann, D., & Bach, F. (2011). Comparison of the Corrosion Behavior of Coated and Uncoated Magnesium Alloys in an In Vitro Corrosion Environment. Advanced Engineering Materials, 13(9). https://doi.org/10.1002/adem.201080144
  4. Biodegradable a of material development and applications
  5. Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008). Foreign body reaction to biomaterials. Seminars in Immunology, 20(2), 86–100. https://doi.org/10.1016/j.smim.2007.11.004
  6. von In vivo assessment of the host reactions to the biodegradation of the two novel magnesium alloys AX in an animal model
  7. Bush, V. J., Moyer, T. P., Batts, K. P., & Parisi, J. E. (1995). Essential and toxic element concentrations in fresh and formalin-fixed human autopsy tissues. Clinical Chemistry, 41(2), 284–294. https://doi.org/10.1093/clinchem/41.2.284
  8. von der Höh Rechenberg von Influence of different surface machining treatments of resorbable magnesium alloy implants on degradation EDX - analysis and histology results Mat - Wiss u
  9. Feyerabend, F., Witte, F., Kammal, M., & Willumeit, R. (2006). Unphysiologically High Magnesium Concentrations Support Chondrocyte Proliferation and Redifferentiation. Tissue Engineering, 12(12), 3545–3556. https://doi.org/10.1089/ten.2006.12.3545
  10. Biodegradable magnesium scaffolds part appropriate inflammatory response
  11. Biocompatibility of fluoride - coated magnesium - calcium alloys with optimized degradation kinetics in a subcutaneous mouse model
  12. AR Enhanced effect of combining human cardiac stem cells and bone marrow mesenchymal stem cells to reduce infarct size and to restore cardiac function after myocardial infarction
  13. Ventriculoplasty excision of myocardial aneurysm report of a successful case
  14. Sarko, J. (2005). Bone and Mineral Metabolism. Emergency Medicine Clinics of North America, 23(3), 703–721. https://doi.org/10.1016/j.emc.2005.03.017
  15. toxicity profile a systematic meta analysis
  16. Adhyapak, S. M., & Parachuri, V. R. (2009). Architecture of the left ventricle: insights for optimal surgical ventricular restoration. Heart Failure Reviews, 15(1), 73–83. https://doi.org/10.1007/s10741-009-9151-0
  17. Anderson, J. M., & Shive, M. S. (1997). Biodegradation and biocompatibility of PLA and PLGA microspheres. Advanced Drug Delivery Reviews, 28(1), 5–24. https://doi.org/10.1016/s0169-409x(97)00048-3
  18. In vivo corrosion and corrosion protection of magnesium alloy
  19. Janning, C., Willbold, E., Vogt, C., Nellesen, J., Meyer-Lindenberg, A., Windhagen, H., Thorey, F., & Witte, F. (2010). Magnesium hydroxide temporarily enhancing osteoblast activity and decreasing the osteoclast number in peri-implant bone remodelling☆. Acta Biomaterialia, 6(5), 1861–1868. https://doi.org/10.1016/j.actbio.2009.12.037
  20. von der Höh Rechenberg von Influence of different surface machining treatments of resorbable magnesium alloy implants on degradation EDX - analysis and histology results Mat - Wiss u
  21. Kirkland, N. T., Waterman, J., Birbilis, N., Dias, G., Woodfield, T. B. F., Hartshorn, R. M., & Staiger, M. P. (2011). Buffer-regulated biocorrosion of pure magnesium. Journal of Materials Science: Materials in Medicine, 23(2), 283–291. https://doi.org/10.1007/s10856-011-4517-y
  22. Becaria, A., Campbell, A., & Bondy, S. (2002). Aluminum as a toxicant. Toxicology and Industrial Health, 18(7), 309–320. https://doi.org/10.1191/0748233702th157oa
  23. Biocompatibility of fluoride - coated magnesium - calcium alloys with optimized degradation kinetics in a subcutaneous mouse model
  24. KLEIN, M. D., HERMAN, M. V., GORLIN, R., & Vayo, H. W. (1967). A Hemodynamic Study of Left Ventricular Aneurysm. Circulation, 35(4), 614–630. https://doi.org/10.1161/01.cir.35.4.614
  25. Dziuba, D., Meyer-Lindenberg, A., Seitz, J. M., Waizy, H., Angrisani, N., & Reifenrath, J. (2013). Long-term in vivo degradation behaviour and biocompatibility of the magnesium alloy ZEK100 for use as a biodegradable bone implant. Acta Biomaterialia, 9(10), 8548–8560. https://doi.org/10.1016/j.actbio.2012.08.028

1–25 of 70

Citations

  1. Menze, R., Hesse, B., Kusmierczuk, M., Chen, D., Weitkamp, T., Bettink, S., & Scheller, B. (2024). Synchrotron microtomography reveals insights into the degradation kinetics of bio-degradable coronary magnesium scaffolds. Bioactive Materials, 32, 1–11. https://doi.org/10.1016/j.bioactmat.2023.09.008
  2. Knigge, S., Mueller, M., Fricke, L., Schilling, T., & Glasmacher, B. (2023). In Vitro Investigation of Corrosion Control of Magnesium with Degradable Polycaprolactone Coatings for Cardiovascular Grafts. Coatings, 13(1), 94. https://doi.org/10.3390/coatings13010094
  3. Schilling, T., Cebotari, S., Kaufeld, T., Tudorache, I., Brandes, G., Hartung, D., Wacker, F., Bauer, M., Haverich, A., & Hassel, T. (2023). Stabilizing A Vascularized Autologous Matrix with Flexible Magnesium Scaffolds to Reconstruct Dysfunctional Left Ventricular Myocardium in a Large-Animal Feasibility Study. Journal of Functional Biomaterials, 14(2), 73. https://doi.org/10.3390/jfb14020073
  4. Schilling, T., Bauer, M., Hartung, D., Brandes, G., Tudorache, I., Cebotari, S., Meyer, T., Wacker, F., Haverich, A., & Hassel, T. (2020). Stabilisation of a Segment of Autologous Vascularised Stomach as a Patch for Myocardial Reconstruction with Degradable Magnesium Alloy Scaffolds in a Swine Model. Crystals, 10(6), 438. https://doi.org/10.3390/cryst10060438
  5. Schilling, T., Bauer, M., Biskup, C., Haverich, A., & Hassel, T. (2017). Engineering of biodegradable magnesium alloy scaffolds to stabilize biological myocardial grafts. Biomedical Engineering / Biomedizinische Technik, 62(5), 493–504. https://doi.org/10.1515/bmt-2016-0205
  6. Durisin, M., Reifenrath, J., Weber, C. M., Eifler, R., Maier, H. J., Lenarz, T., & Seitz, J. (2015). Biodegradable nasal stents (MgF2‐coated Mg–2 wt %Nd alloy)—A long‐termin vivostudy. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 105(2), 350–365. https://doi.org/10.1002/jbm.b.33559
  7. Weber, C. M., Eifler, R., Seitz, J.-M., Maier, H. J., Reifenrath, J., Lenarz, T., & Durisin, M. (2015). Biocompatibility of MgF2-coated MgNd2 specimens in contact with mucosa of the nasal sinus – A long term study. Acta Biomaterialia, 18, 249–261. https://doi.org/10.1016/j.actbio.2015.03.003