A synthetic lung model (ASYLUM) for validation of functional lung imaging methods shows significant differences between signal-based and deformation-field-based ventilation measurements
Authors/Creators
Description
IntroductionValidation of functional free-breathing MRI involves a comparison to more established or more direct measurements. This procedure is cost-intensive, as it requires access to patient cohorts, lengthy protocols, expenses for consumables, and binds working time. Therefore, the purpose of this study is to introduce a synthetic lung model (ASYLUM), which mimics dynamic MRI acquisition and includes predefined lung abnormalities for an alternative validation approach. The model is evaluated with different registration and quantification methods and compared with real data.MethodsA combination of trigonometric functions, deformation fields, and signal combinations were used to create 20 synthetic image time series. Lung voxels were assigned either to normal or one of six abnormality classes. The images were registered with three registration algorithms. The registered images were further analyzed with three quantification methods: deformation-based or signal-based regional ventilation (JVent/RVent) analysis and perfusion amplitude (QA). The registration results were compared with predefined deformations. Quantification methods were evaluated regarding predefined amplitudes and with respect to sensitivity, specificity, and spatial overlap of defects. In addition, 36 patients with chronic obstructive pulmonary disease were included for verification of model interpretations using CT as the gold standard.ResultsOne registration method showed considerably lower quality results (76% correlation vs. 92/97%, p ≤ 0.0001). Most ventilation defects were correctly detected with RVent and QA (e.g., one registration variant with sensitivity ≥78%, specificity ≥88). Contrary to this, JVent showed very low sensitivity for lower lung quadrants (0–16%) and also very low specificity (1–29%) for upper lung quadrants. Similar patterns of defect detection differences between RVent and JVent were also observable in patient data: Firstly, RVent was more aligned with CT than JVent for all quadrants (p ≤ 0.01) except for one registration variant in the lower left region. Secondly, stronger differences in overlap were observed for the upper quadrants, suggesting a defect bias in the JVent measurements in the upper lung regions.ConclusionThe feasibility of a validation framework for free-breathing functional lung imaging using synthetic time series was demonstrated. Evaluating different ventilation measurements, important differences were detected in synthetic and real data, with signal-based regional ventilation assessment being a more reliable method in the investigated setting.
Additional details
Identifiers
Dates
- Issued
-
September 4, 2024
References
- Sharma, M., Wyszkiewicz, P. V., Desaigoudar, V., Guo, F., Capaldi, D. P., & Parraga, G. (2022). Quantification of pulmonary functional MRI: state-of-the-art and emerging image processing methods and measurements. Physics in Medicine & Biology, 67(22), 22TR01. https://doi.org/10.1088/1361-6560/ac9510
- Bauman, G., Puderbach, M., Deimling, M., Jellus, V., Chefd'hotel, C., Dinkel, J., Hintze, C., Kauczor, H., & Schad, L. R. (2009). Non‐contrast‐enhanced perfusion and ventilation assessment of the human lung by means of fourier decomposition in proton MRI. Magnetic Resonance in Medicine, 62(3), 656–664. https://doi.org/10.1002/mrm.22031
- Bauman, G., & Bieri, O. (2016). Matrix pencil decomposition of time‐resolved proton MRI for robust and improved assessment of pulmonary ventilation and perfusion. Magnetic Resonance in Medicine, 77(1), 336–342. https://doi.org/10.1002/mrm.26096
- Fischer, A., Weick, S., Ritter, C. O., Beer, M., Wirth, C., Hebestreit, H., Jakob, P. M., Hahn, D., Bley, T., & Köstler, H. (2014). SElf‐gated Non‐Contrast‐Enhanced FUnctional Lung imaging (SENCEFUL) using a quasi‐random fast low‐angle shot (FLASH) sequence and proton MRI. NMR in Biomedicine, 27(8), 907–917. https://doi.org/10.1002/nbm.3134
- Mendes Pereira, L., Wech, T., Weng, A. M., Kestler, C., Veldhoen, S., Bley, T. A., & Köstler, H. (2018). UTE‐SENCEFUL: first results for 3D high‐resolution lung ventilation imaging. Magnetic Resonance in Medicine, 81(4), 2464–2473. https://doi.org/10.1002/mrm.27576
- Voskrebenzev, A., Gutberlet, M., Klimeš, F., Kaireit, T. F., Schönfeld, C., Rotärmel, A., Wacker, F., & Vogel‐Claussen, J. (2017). Feasibility of quantitative regional ventilation and perfusion mapping with phase‐resolved functional lung (PREFUL) MRI in healthy volunteers and COPD, CTEPH, and CF patients. Magnetic Resonance in Medicine, 79(4), 2306–2314. https://doi.org/10.1002/mrm.26893
- Klimeš, F., Voskrebenzev, A., Gutberlet, M., Kern, A. L., Behrendt, L., Grimm, R., Suhling, H., Crisosto, C. G., Kaireit, T. F., Pöhler, G. H., Glandorf, J., Wacker, F., & Vogel‐Claussen, J. (2020). 3D phase‐resolved functional lung ventilation MR imaging in healthy volunteers and patients with chronic pulmonary disease. Magnetic Resonance in Medicine, 85(2), 912–925. https://doi.org/10.1002/mrm.28482
- Kjørstad, Å., Corteville, D. M. R., Henzler, T., Schmid-Bindert, G., Hodneland, E., Zöllner, F. G., & Schad, L. R. (2014). Quantitative lung ventilation using Fourier decomposition MRI; comparison and initial study. Magnetic Resonance Materials in Physics, Biology and Medicine, 27(6), 467–476. https://doi.org/10.1007/s10334-014-0432-9
- Chassagnon, G., Martin, C., Marini, R., Vakalopolou, M., Régent, A., Mouthon, L., Paragios, N., & Revel, M.-P. (2019). Use of Elastic Registration in Pulmonary MRI for the Assessment of Pulmonary Fibrosis in Patients with Systemic Sclerosis. Radiology, 291(2), 487–492. https://doi.org/10.1148/radiol.2019182099
- Boucneau, T., Fernandez, B., Larson, P., Darrasse, L., & Maître, X. (2020). 3D Magnetic Resonance Spirometry. Scientific Reports, 10(1). https://doi.org/10.1038/s41598-020-66202-7
- Tan, F., Zhu, X., Chan, M., Deveshwar, N., Willmering, M. M., Lustig, M., & Larson, P. E. Z. (2023). Pulmonary Ventilation Analysis Using 1 H Ultra-Short Echo Time (UTE) Lung MRI: A Reproducibility Study [Preprint]. In bioRxiv. openRxiv. https://doi.org/10.1101/2023.10.22.563196
- Lederlin, M., Bauman, G., Eichinger, M., Dinkel, J., Brault, M., Biederer, J., & Puderbach, M. (2013). Functional MRI using Fourier decomposition of lung signal: Reproducibility of ventilation- and perfusion-weighted imaging in healthy volunteers. European Journal of Radiology, 82(6), 1015–1022. https://doi.org/10.1016/j.ejrad.2012.12.003
- Voskrebenzev, A., Gutberlet, M., Becker, L., Wacker, F., & Vogel‐Claussen, J. (2015). Reproducibility of fractional ventilation derived by Fourier decomposition after adjusting for tidal volume with and without an MRI compatible spirometer. Magnetic Resonance in Medicine, 76(5), 1542–1550. https://doi.org/10.1002/mrm.26047
- Pöhler, G. H., Klimeš, F., Behrendt, L., Voskrebenzev, A., Gonzalez, C. C., Wacker, F., Hohlfeld, J. M., & Vogel‐Claussen, J. (2020). Repeatability of Phase‐Resolved Functional Lung (PREFUL)‐MRI Ventilation and Perfusion Parameters in Healthy Subjects and COPD Patients. Journal of Magnetic Resonance Imaging, 53(3), 915–927. https://doi.org/10.1002/jmri.27385
- Klimeš, F., Voskrebenzev, A., Gutberlet, M., Obert, A. J., Pöhler, G. H., Grimm, R., Behrendt, L., Crisosto, C., Glandorf, J., Moher Alsady, T., Wacker, F., & Vogel‐Claussen, J. (2021). Repeatability of dynamic 3D phase‐resolved functional lung (PREFUL) ventilation MR Imaging in patients with chronic obstructive pulmonary disease and healthy volunteers. Journal of Magnetic Resonance Imaging, 54(2), 618–629. https://doi.org/10.1002/jmri.27543
- Bauman, G., Puderbach, M., Heimann, T., Kopp-Schneider, A., Fritzsching, E., Mall, M. A., & Eichinger, M. (2013). Validation of Fourier decomposition MRI with dynamic contrast-enhanced MRI using visual and automated scoring of pulmonary perfusion in young cystic fibrosis patients. European Journal of Radiology, 82(12), 2371–2377. https://doi.org/10.1016/j.ejrad.2013.08.018
- Capaldi, D. P. I., Sheikh, K., Guo, F., Svenningsen, S., Etemad-Rezai, R., Coxson, H. O., Leipsic, J. A., McCormack, D. G., & Parraga, G. (2015). Free-breathing Pulmonary 1H and Hyperpolarized 3He MRI. Academic Radiology, 22(3), 320–329. https://doi.org/10.1016/j.acra.2014.10.003
- Behrendt, L., Voskrebenzev, A., Klimeš, F., Gutberlet, M., Winther, H. B., Kaireit, T. F., Alsady, T. M., Pöhler, G. H., Derlin, T., Wacker, F., & Vogel‐Claussen, J. (2019). Validation of Automated Perfusion‐Weighted Phase‐Resolved Functional Lung (PREFUL)‐MRI in Patients With Pulmonary Diseases. Journal of Magnetic Resonance Imaging, 52(1), 103–114. https://doi.org/10.1002/jmri.27027
- Kaireit, T. F., Kern, A., Voskrebenzev, A., Pöhler, G. H., Klimes, F., Behrendt, L., Gutberlet, M., Moher‐Alsady, T., Dittrich, A., Wacker, F., Hohlfeld, J., & Vogel‐Claussen, J. (2020). Flow Volume Loop and Regional Ventilation Assessment Using Phase‐Resolved Functional Lung ( PREFUL ) MRI : Comparison With 129 Xenon Ventilation MRI and Lung Function Testing. Journal of Magnetic Resonance Imaging, 53(4), 1092–1105. https://doi.org/10.1002/jmri.27452
- Marshall, H., Voskrebenzev, A., Smith, L. J., Biancardi, A. M., Kern, A. L., Collier, G. J., Wielopolski, P. A., Ciet, P., Tiddens, H. A. W. M., Vogel‐Claussen, J., & Wild, J. M. (2022). 129Xe and Free‐Breathing 1H Ventilation MRI in Patients With Cystic Fibrosis: A Dual‐Center Study. Journal of Magnetic Resonance Imaging, 57(6), 1908–1921. https://doi.org/10.1002/jmri.28470
- Vogel-Claussen, J. (2021). Functional Lung MRI: Deep Learning Turns Proton into Helium Ventilation Maps—The Battle Is On!. Radiology, 298(2), 439–440. https://doi.org/10.1148/radiol.2020204069
- Hughes, P. J. C., Smith, L., Chan, H.-F., Tahir, B. A., Norquay, G., Collier, G. J., Biancardi, A., Marshall, H., & Wild, J. M. (2019). Assessment of the influence of lung inflation state on the quantitative parameters derived from hyperpolarized gas lung ventilation MRI in healthy volunteers. Journal of Applied Physiology, 126(1), 183–192. https://doi.org/10.1152/japplphysiol.00464.2018
- Murphy, K., van Ginneken, B., Reinhardt, J. M., Kabus, S., Ding, K., Deng, X., Cao, K., Du, K., Christensen, G. E., Garcia, V., Vercauteren, T., Ayache, N., Commowick, O., Malandain, G., Glocker, B., Paragios, N., Navab, N., Gorbunova, V., Sporring, J., … Pluim, J. P. W. (2011). Evaluation of Registration Methods on Thoracic CT: The EMPIRE10 Challenge. IEEE Transactions on Medical Imaging, 30(11), 1901–1920. https://doi.org/10.1109/tmi.2011.2158349
- Klimeš, F., Voskrebenzev, A., Gutberlet, M., Kern, A., Behrendt, L., Kaireit, T. F., Czerner, C., Renne, J., Wacker, F., & Vogel‐Claussen, J. (2019). Free‐breathing quantification of regional ventilation derived by phase‐resolved functional lung (PREFUL) MRI. NMR in Biomedicine, 32(6), Article e4088. https://doi.org/10.1002/nbm.4088
- Voskrebenzev, A., Kaireit, T. F., Klimeš, F., Pöhler, G. H., Behrendt, L., Biller, H., Berschneider, K., Wacker, F., Welte, T., Hohlfeld, J. M., & Vogel-Claussen, J. (2022). PREFUL MRI Depicts Dual Bronchodilator Changes in COPD: A Retrospective Analysis of a Randomized Controlled Trial. Radiology: Cardiothoracic Imaging, 4(2). https://doi.org/10.1148/ryct.210147
1–25 of 53
Citations
- Klimeš, F., Plummer, J. W., Voskrebenzev, A., Gutberlet, M., Klein, M. M., Willmering, M. M., Matheson, A. M., Bdaiwi, A. S., Wacker, F., Woods, J. C., Cleveland, Z. I., Walkup, L. L., & Vogel‐Claussen, J. (2026). Comparison of Signal‐ and Volume‐Based Ventilation‐Weighted Assessment Using 3D FLORET UTE MRI in Patients With Various Pulmonary Disease. Magnetic Resonance in Medicine, Article mrm.70239. https://doi.org/10.1002/mrm.70239
- Voskrebenzev, A., Kaireit, T. F., Klein, M. M., Kern, A. L., Behrendt, L., Klimeš, F., Müller, R. A., Kayser, T., Wacker, F., Vogel-Claussen, J., & Hohlfeld, J. M. (2026). Phase-resolved functional lung MRI detects single-dose and sustained bronchodilator responses in COPD in a randomized crossover trial. European Radiology, 36(10), 7731–7746. https://doi.org/10.1007/s00330-026-12604-6
- Kern, A. L., Klimeš, F., Voskrebenzev, A., Shin, H., & Vogel‐Claussen, J. (2025). Functional Pulmonary Imaging. Journal of Magnetic Resonance Imaging, 62(4), 986–1008. https://doi.org/10.1002/jmri.29778