Published October 16, 2018 | Journal article | Version v1 | https://doi.org/10.1371/journal.pone.0205394

Percutaneous MR-guided interventions using an optical Moiré Phase tracking system: Initial results

Additional details

Funding

BMBF
13GW0095A
BMBF
13GW0095C

Dates

Issued
October 16, 2018

References

  1. Barkhausen, J., Kahn, T., Krombach, G., Kuhl, C., Lotz, J., Maintz, D., Ricke, J., Schönberg, S., Vogl, T., Wacker, F., & Radiology, G. A. of C. in A. (2017). White Paper: Interventional MRI: Current Status and Potential for Development Considering Economic Perspectives, Part 1: General Application. RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 189(07), 611–623. https://doi.org/10.1055/s-0043-110011
  2. Rothgang, E., Gilson, W. D., Wacker, F., Hornegger, J., Lorenz, C. H., & Weiss, C. R. (2013). Rapid freehand MR‐guided percutaneous needle interventions: An image‐based approach to improve workflow and feasibility. Journal of Magnetic Resonance Imaging, 37(5), 1202–1212. https://doi.org/10.1002/jmri.23894
  3. Busse, H., Riedel, T., Garnov, N., Thörmer, G., Kahn, T., Moche, M., & Zhang, H. (2015). Targeting Accuracy, Procedure Times and User Experience of 240 Experimental MRI Biopsies Guided by a Clinical Add-On Navigation System. PLOS ONE, 10(7), e0134370. https://doi.org/10.1371/journal.pone.0134370
  4. Weiss, C. R., Nour, S. G., & Lewin, J. S. (2008). MR‐guided biopsy: A review of current techniques and applications. Journal of Magnetic Resonance Imaging, 27(2), 311–325. https://doi.org/10.1002/jmri.21270
  5. Hushek, S. G., Martin, A. J., Steckner, M., Bosak, E., Debbins, J., & Kucharzyk, W. (2008). MR systems for MRI‐guided interventions. Journal of Magnetic Resonance Imaging, 27(2), 253–266. https://doi.org/10.1002/jmri.21269
  6. Meyer, B. C., Brost, A., Kraitchman, D. L., Gilson, W. D., Strobel, N., Hornegger, J., Lewin, J. S., & Wacker, F. K. (2013). Percutaneous Punctures with MR Imaging Guidance: Comparison between MR Imaging–enhanced Fluoroscopic Guidance and Real-time MR Imaging Guidance. Radiology, 266(3), 912–919. https://doi.org/10.1148/radiol.12120117
  7. Fischbach, F., Bunke, J., Thormann, M., Gaffke, G., Jungnickel, K., Smink, J., & Ricke, J. (2010). MR-Guided Freehand Biopsy of Liver Lesions With Fast Continuous Imaging Using a 1.0-T Open MRI Scanner: Experience in 50 Patients. CardioVascular and Interventional Radiology, 34(1), 188–192. https://doi.org/10.1007/s00270-010-9836-8
  8. Barkhausen, J., Kahn, T., Krombach, G., Kuhl, C., Lotz, J., Maintz, D., Ricke, J., Schönberg, S., Vogl, T., Wacker, F., & Radiology, G. A. of C. in A. (2017). White Paper: Interventional MRI: Current Status and Potential for Development Considering Economic Perspectives, Part 2: Liver and Other Applications in Oncology. RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 189(11), 1047–1054. https://doi.org/10.1055/s-0043-112336
  9. Christoforou, E., Akbudak, E., Ozcan, A., Karanikolas, M., & Tsekos, N. V. (2007). Performance of interventions with manipulator-driven real-time MR guidance: implementation and initial in vitro tests. Magnetic Resonance Imaging, 25(1), 69–77. https://doi.org/10.1016/j.mri.2006.08.016
  10. Moche, M., Zajonz, D., Kahn, T., & Busse, H. (2010). MRI‐guided procedures in various regions of the body using a robotic assistance system in a closed‐bore scanner: Preliminary clinical experience and limitations. Journal of Magnetic Resonance Imaging, 31(4), 964–974. https://doi.org/10.1002/jmri.21990
  11. Wacker, F. K., Vogt, S., Khamene, A., Jesberger, J. A., Nour, S. G., Elgort, D. R., Sauer, F., Duerk, J. L., & Lewin, J. S. (2006). An Augmented Reality System for MR Image–guided Needle Biopsy: Initial Results in a Swine Model. Radiology, 238(2), 497–504. https://doi.org/10.1148/radiol.2382041441
  12. Fritz, J., U-Thainual, P., Ungi, T., Flammang, A. J., Kathuria, S., Fichtinger, G., Iordachita, I. I., & Carrino, J. A. (2014). MR-Guided Vertebroplasty With Augmented Reality Image Overlay Navigation. CardioVascular and Interventional Radiology, 37(6), 1589–1596. https://doi.org/10.1007/s00270-014-0885-2
  13. de Oliveira, A., Rauschenberg, J., Beyersdorff, D., Semmler, W., & Bock, M. (2008). Automatic passive tracking of an endorectal prostate biopsy device using phase‐only cross‐correlation. Magnetic Resonance in Medicine, 59(5), 1043–1050. https://doi.org/10.1002/mrm.21430
  14. Busse, H., Garnov, N., Thörmer, G., Zajonz, D., Gründer, W., Kahn, T., & Moche, M. (2010). Flexible add‐on solution for MR image‐guided interventions in a closed‐bore scanner environment. Magnetic Resonance in Medicine, 64(3), 922–928. https://doi.org/10.1002/mrm.22464
  15. Kariniemi, J., Blanco Sequeiros, R., Ojala, R., & Tervonen, O. (2004). MRI-guided abdominal biopsy in a 0.23-T open-configuration MRI system. European Radiology, 15(6), 1256–1262. https://doi.org/10.1007/s00330-004-2566-z
  16. Maclaren, J., Armstrong, B. S. R., Barrows, R. T., Danishad, K. A., Ernst, T., Foster, C. L., Gumus, K., Herbst, M., Kadashevich, I. Y., Kusik, T. P., Li, Q., Lovell-Smith, C., Prieto, T., Schulze, P., Speck, O., Stucht, D., Zaitsev, M., & Hess, C. P. (2012). Measurement and Correction of Microscopic Head Motion during Magnetic Resonance Imaging of the Brain. PLoS ONE, 7(11), e48088. https://doi.org/10.1371/journal.pone.0048088
  17. Stucht, D., Danishad, K. A., Schulze, P., Godenschweger, F., Zaitsev, M., Speck, O., & Kassubek, J. (2015). Highest Resolution In Vivo Human Brain MRI Using Prospective Motion Correction. PLOS ONE, 10(7), e0133921. https://doi.org/10.1371/journal.pone.0133921
  18. Lüsebrink, F., Sciarra, A., Mattern, H., Yakupov, R., & Speck, O. (2017). T1-weighted in vivo human whole brain MRI dataset with an ultrahigh isotropic resolution of 250 μm. Scientific Data, 4(1). https://doi.org/10.1038/sdata.2017.32
  19. van den Berg, J. C. (2014). Update on New Tools for Three-dimensional Navigation in Endovascular Procedures. AORTA, 2(6), 279–285. https://doi.org/10.12945/j.aorta.2014.14-054
  20. Development of NASA-TLX (Task Load Index): Results of Empirical and Theoretical Research. (1988). Development of NASA-TLX (Task Load Index): Results of Empirical and Theoretical Research. In Advances in Psychology (pp. 139–183). Elsevier. https://doi.org/10.1016/s0166-4115(08)62386-9

Citations

  1. Uribe Rivera, A. K., & Giménez, M. E. (2025). Democratization in abdominal ablation therapies: The impact of percutaneous robotic assistance on accuracy—A systematic review. Journal of Robotic Surgery, 19(1). https://doi.org/10.1007/s11701-024-02158-4
  2. Uribe Rivera, A. K., Seeliger, B., Goffin, L., García-Vázquez, A., Mutter, D., & Giménez, M. E. (2024). Robotic Assistance in Percutaneous Liver Ablation Therapies: A Systematic Review and Meta-Analysis. Annals of Surgery Open, 5(2), e406. https://doi.org/10.1097/as9.0000000000000406
  3. Peters, J., Licher, J., Hensen, B., Wacker, F., & Raatz, A. (2024). Soft Robotic Actuator Leveraging Switchable Strain-Limiting Structures for Tumor Biopsy and Ablation in MRI. 2024 IEEE 7th International Conference on Soft Robotics (RoboSoft), 983–989. https://doi.org/10.1109/robosoft60065.2024.10521966
  4. Sengupta, S., Yan, X., Hoyt, T. L., Drake, G., Gunderman, A., & Chen, Y. (2021). Minimal artifact actively shimmed metallic needles in MRI. Magnetic Resonance in Medicine, 87(1), 541–550. https://doi.org/10.1002/mrm.28977
  5. Sengupta, S. (2020). Modeling of active shimming of metallic needles for interventional MRI. Magnetic Resonance in Medicine, 84(5), 2858–2870. https://doi.org/10.1002/mrm.28320
  6. Rothgang, E., Anderson, W. S., Breton, E., Gangi, A., Garnon, J., Hensen, B., Judy, B. F., Kägebein, U., & Wacker, F. K. (2020). Interventional imaging: MR. In Handbook of Medical Image Computing and Computer Assisted Intervention (pp. 673–699). Elsevier. https://doi.org/10.1016/b978-0-12-816176-0.00032-6
  7. Pan, L., Valdeig, S., Kägebein, U., Qing, K., Fetics, B., Roth, A., Nevo, E., Hensen, B., Weiss, C. R., Wacker, F. K., & Zu, Z. (2020). Integration and evaluation of a gradient-based needle navigation system for percutaneous MR-guided interventions. PLOS ONE, 15(7), e0236295. https://doi.org/10.1371/journal.pone.0236295