Published January 2016 | Journal article | Version v1 | https://doi.org/10.1111/voxs.12192

Recombinant blood group proteins in clinical practice – from puzzling to binary antibody testing

Description

The main drawback of red blood cell (RBC)‐based antibody detection assays is that a positive reaction between serum and test cells does not identify the specificity of a given red blood cell antibody. When antibody mixtures or rare RBC antibodies are present, this indirect method reaches its limits. Recently, CE‐marked recombinant blood group proteins (rBGPs) have become available in sufficient quantity and quality. The advantage of rBGPs over RBCs is that proteins carrying a single antigen can be used in the antibody identification assay, so a positive test directly indicates the presence and specificity of the target antibody. The use of soluble rBGPs in addition to RBCs has been shown to increase the sensitivity and specificity of antibody detection and identification in cases with difficult‐to‐identify antibodies, resulting in increased efficiency in providing blood to immunized patients. The rBGPs have been successfully used in a wide range of solid‐phase assays (ELISA, microspheres, microarrays). Although all relevant antigen specificities have not yet been established, rBGPs have a diagnostic potential that could already be useful in antibody detection assays combining RBC‐derived antigens and recombinantly expressed antigens. Such combined assays would benefit from the potential of rBGPs for single‐step, direct antibody detection and identification, which could greatly facilitate and accelerate the identification of common and rare RBC antibodies. The clinical use of rBGPs in pretransfusion antibody screening would introduce a paradigm shift that could help to reduce the risk of haemolytic transfusion reaction, one of the leading causes of transfusion‐related death.

Additional details

Dates

Issued
January 2016

References

  1. Bolton‐Maggs, P. H. B., & Cohen, H. (2013). Serious H azards of T ransfusion (SHOT) haemovigilance and progress is improving transfusion safety. British Journal of Haematology, 163(3), 303–314. https://doi.org/10.1111/bjh.12547
  2. Seltsam, A., Wagner, F. F., Salama, A., & Flegel, W. A. (2003). Antibodies to high‐frequency antigens may decrease the quality of transfusion support: an observational study. Transfusion, 43(11), 1563–1566. https://doi.org/10.1046/j.1537-2995.2003.00565.x
  3. Seltsam, A., & Blasczyk, R. (2009). Recombinant blood group proteins for use in antibody screening and identification tests. Current Opinion in Hematology, 16(6), 473–479. https://doi.org/10.1097/moh.0b013e3283319a06
  4. Seltsam, A., Grueger, D., Blasczyk, R., & Flegel, W. A. (2009). Easy identification of antibodies to high‐prevalence Scianna antigens and detection of admixed alloantibodies using soluble recombinant Scianna protein. Transfusion, 49(10), 2090–2096. https://doi.org/10.1111/j.1537-2995.2009.02255.x
  5. Seltsam, A., Grüger, D., & Blasczyk, R. (2007). Prokaryotic versus eukaryotic recombinant Lutheran blood group protein for antibody identification. Transfusion, 47(9), 1630–1636. https://doi.org/10.1111/j.1537-2995.2007.01334.x
  6. Seltsam, A., Strigens, S., Levene, C., Yahalom, V., Moulds, M., Moulds, J. J., Hustinx, H., Weisbach, V., Figueroa, D., Bade‐Doeding, C., DeLuca, D. S., & Blasczyk, R. (2006). The molecular diversity of Sema7A, the semaphorin that carries the JMH blood group antigens. Transfusion, 47(1), 133–146. https://doi.org/10.1111/j.1537-2995.2007.01076.x
  7. Seltsam, A., Wagner, F., Lambert, M., Bullock, T., Thornton, N., Scharberg, E. A., Grueger, D., Schneeweiss, C., & Blasczyk, R. (2014). Recombinant blood group proteins facilitate the detection of alloantibodies to high‐prevalence antigens and reveal underlying antibodies: results of an international study. Transfusion, 54(7), 1823–1830. https://doi.org/10.1111/trf.12553
  8. Seltsam, A., Agaylan, A., Grueger, D., Meyer, O., Blasczyk, R., & Salama, A. (2008). Rapid detection of JMH antibodies with recombinant Sema7A (CD108) protein and the particle gel immunoassay. Transfusion, 48(6), 1151–1155. https://doi.org/10.1111/j.1537-2995.2008.01660.x
  9. Seltsam, A., Agaylan, A., Grueger, D., Meyer, O., Blasczyk, R., & Salama, A. (2008). Rapid detection of anti‐Lub with recombinant Lub protein and the particle gel immunoassay. Transfusion, 48(4), 731–734. https://doi.org/10.1111/j.1537-2995.2007.01596.x
  10. Ridgwell, K., Dixey, J., & Scott, M. L. (2007). Production of soluble recombinant proteins with Kell, Duffy and Lutheran blood group antigen activity, and their use in screening human sera for Kell, Duffy and Lutheran antibodies. Transfusion Medicine, 17(5), 384–394. https://doi.org/10.1111/j.1365-3148.2007.00762.x
  11. Daniels, G. L., Green, C. A., Powell, R. M., & Ward, T. (1998). Hemagglutination inhibition of Cromer blood group antibodies with soluble recombinant decay‐accelerating factor. Transfusion, 38(4), 332–336. https://doi.org/10.1046/j.1537-2995.1998.38498257370.x
  12. Moulds, J. M., & Rowe, K. E. (1996). Neutralization of Knops system antibodies using soluble complement receptor 1. Transfusion, 36(6), 517–520. https://doi.org/10.1046/j.1537-2995.1996.36696269510.x
  13. Telen, M., Rao, N., Udani, M., Thompson, E., Kaufman, R., & Lublin, D. (1994). Molecular mapping of the Cromer blood group Cra and Tca epitopes of decay accelerating factor: toward the use of recombinant antigens in immunohematology. Blood, 84(9), 3205–3211. https://doi.org/10.1182/blood.v84.9.3205.3205
  14. Yazdanbakhsh, K., �yen, R., Yu, Q., Lee, S., Antoniou, M., Chaudhuri, A., & Reid, M. E. (2000). High-level, stable expression of blood group antigens in a heterologous system. American Journal of Hematology, 63(3), 114–124. https://doi.org/10.1002/(sici)1096-8652(200003)63:3%3C114::aid-ajh2%3E3.0.co;2-z
  15. Soluble recombinant blood group proteins for red blood cell antibody identification
  16. Alloantibodies directed against high‐frequency red blood cell antigens
  17. Smith, J. D., Hamour, I. M., . Banner, N. R., & Rose, M. L. (2007). C4d Fixing, Luminex Binding Antibodies—A New Tool for Prediction of Graft Failure After Heart Transplantation. American Journal of Transplantation, 7(12), 2809–2815. https://doi.org/10.1111/j.1600-6143.2007.01991.x
  18. Blackall, D. P., Ugorski, M., Smith, M. E., Pahlsson, P., & Spitalnik, S. L. (1992). The binding of human alloantibodies to recombinant glycophorin A. Transfusion, 32(7), 629–632. https://doi.org/10.1046/j.1537-2995.1992.32792391035.x
  19. Ugorski, M., Blackall, D., Pahlsson, P., Shakin-Eshleman, S., Moore, J., & Spitalnik, S. (1993). Recombinant Miltenberger I and II human blood group antigens: the role of glycosylation in cell surface expression and antigenicity of glycophorin A. Blood, 82(6), 1913–1920. https://doi.org/10.1182/blood.v82.6.1913.1913
  20. Liu, W., Avent, N. D., Jones, J. W., Scott, M. L., & Voak, D. (1999). Molecular Configuration of Rh D Epitopes as Defined by Site-Directed Mutagenesis and Expression of Mutant Rh Constructs in K562 Erythroleukemia Cells. Blood, 94(12), 3986–3996. https://doi.org/10.1182/blood.v94.12.3986
  21. Buchs, J.-P., & Nydegger, U. E. (1989). Development of an ABO-ELISA for the quantitation of human blood group anti-A and anti-B IgM and IgG antibodies. Journal of Immunological Methods, 118(1), 37–46. https://doi.org/10.1016/0022-1759(89)90050-1
  22. Spitalnik, S., Cowles, J., Cox, M. T., Baker, D., Holt, J., & Blumberg, N. (1983). A New Technique in Quantitative Immunohematology: Solid‐Phase Kinetic Enzyme‐Linked Immunosorbent Assay. Vox Sanguinis, 45(6), 440–448. https://doi.org/10.1111/j.1423-0410.1983.tb01942.x
  23. Spitalnik, S. L., Cowles, J. W., Cox, M. T., & Blumberg, N. (1983). Neutralization of Lewis Blood Group Antibodies by Synthetic Immunoadsorbents. American Journal of Clinical Pathology, 80(1), 63–65. https://doi.org/10.1093/ajcp/80.1.63
  24. Rearden, A. (1993). Immunogenicity and antigenicity of defined linear determinants of the MN sialoglycoprotein glycophorin A. Transfusion, 33(6), 476–483. https://doi.org/10.1046/j.1537-2995.1993.33693296809.x