Published 2024 | Journal article | Version v1 | https://doi.org/10.1159/000536065

Photon Counting Computed Tomography with the Radiation Dose of a Chest X-Ray: Feasibility and Diagnostic Yield

Description

Introduction: Photon counting (PC) detectors allow a reduction of the radiation dose in CT. Chest X-ray (CXR) is known to have a low sensitivity and specificity for detection of pneumonic infiltrates. The aims were to establish an ultra-low-dose CT (ULD-CT) protocol at a PC-CT with the radiation dose comparable to the dose of a CXR and to evaluate its clinical yield in patients with suspicion of pneumonia. Methods: A ULD-CT protocol was established with the aim to meet the radiation dose of a CXR. In this retrospective study, all adult patients who received a ULD-CT of the chest with suspected pneumonia were included. Radiation exposure of ULD-CT and CXR was calculated. The clinical significance (new diagnosis, change of therapy, additional findings) and limitations were evaluated by a radiologist and a pulmonologist considering previous CXR and clinical data. Results: Twenty-seven patients (70% male, mean age 68 years) were included. With our ULD-CT protocol, the radiation dose of a CXR could be reached (mean radiation exposure 0.11 mSv). With ULD-CT, the diagnosis changed in 11 patients (41%), there were relevant additional findings in 4 patients (15%), an infiltrate (particularly fungal infiltrate under immunosuppression) could be ruled out with certainty in 10 patients (37%), and the therapy changed in 10 patients (37%). Two patients required an additional CT with contrast medium to rule out a pulmonary embolism or pleural empyema. Conclusions: With ULD-CT, the radiation dose of a CXR could be reached while the clinical impact is higher with change in diagnosis in 41%.

Additional details

Dates

Issued
2024

Citations

  1. https://doi.org/10.1055/a-2977-0644
  2. https://doi.org/10.1148/radiol.251496
  3. https://doi.org/10.1183/23120541.00081-2026
  4. Schwartz, F. R. (2025). Photon-Counting CT in Emergency Radiology. In Clinical Applications of Spectral Photon Counting Computed Tomography Technology (pp. 113–130). Springer Nature Switzerland. https://doi.org/10.1007/978-3-031-85078-3_6
  5. Zellner, M., Sartoretti, T., Flohr, T., Frauenfelder, T., Alkadhi, H., Kellenberger, C. J., & Mergen, V. (2025). Paediatric high-pitch lung imaging with photon-counting detector computed tomography: a dose reduction phantom study. Pediatric Radiology, 55(6), 1191–1201. https://doi.org/10.1007/s00247-025-06235-0
  6. Huflage, H., Hackenbroch, C., Schüle, S., Kunz, A. S., Gruschwitz, P., Razinskas, G., Beer, M., Bley, T. A., Wech, T., & Grunz, J.-P. (2025). Advanced Lung Imaging with Photon-counting Detectors: Insights from Thermoluminescence Dosimetry. Academic Radiology, 32(1), 518–525. https://doi.org/10.1016/j.acra.2024.08.013
  7. Greffier, J., Fitton, I., de Oliveira, F., Dang Tran, K. D., Beregi, J.-P., Croisille, C., Dabli, D., & Van Ngoc Ty, C. (2025). Contribution of photon counting CT to the detectability of lung nodules using ultra-low dose CT protocols: a phantom study. Physica Medica, 138, 105180. https://doi.org/10.1016/j.ejmp.2025.105180
  8. van der Bie, J., van der Laan, T., van Straten, M., Booij, R., Bos, D., Dijkshoorn, M. L., Hirsch, A., Oei, E. H. G., & Budde, R. P. J. (2025). Photon-counting CT: An updated review of clinical results. European Journal of Radiology, 190, Article 112189. https://doi.org/10.1016/j.ejrad.2025.112189
  9. Fayon, M., Hill, K., Waldron, M., Messore, B., Riberi, L., Svedberg, M., Lammertyn, E., Fustik, S., Gramegna, A., Stahl, M., Kerpel-Fronius, A., Balbi, M., Ciet, P., Chassagnon, G., Ferrero, C., Burgel, P.-R., Sutharsan, S., Opitz, M., Andrinopoulou, E.-R., … Sermet, I. (2025). Guidance for chest-CT in children and adults with cystic fibrosis: A European perspective. Respiratory Medicine, 241, Article 108076. https://doi.org/10.1016/j.rmed.2025.108076
  10. https://doi.org/10.1088/1361-6560/add4ba
  11. https://doi.org/10.1093/bjr/tqaf026
  12. https://doi.org/10.1097/rct.0000000000001756
  13. https://doi.org/10.1097/rli.0000000000001174
  14. https://doi.org/10.1158/1078-0432.ccr-25-0597
  15. https://doi.org/10.1183/13993003.02476-2024
  16. https://doi.org/10.3390/tomography11120134
  17. Tafti, S., Abadia, A., Fung, G., Ramirez-Giraldo, J. C., & O’ Doherty, J. (2024). Comparison of Hounsfield Unit variability between two same model photon counting CT detector systems. A phantom study applied to lung CT. Physica Medica, 126, Article 104828. https://doi.org/10.1016/j.ejmp.2024.104828
  18. https://doi.org/10.4187/respcare.12061