Avoiding Untimely Implantable Cardioverter/Defibrillator Implantation by Intensified Heart Failure Therapy Optimization Supported by the Wearable Cardioverter/Defibrillator—The PROLONG Study
Description
Background Optimal timing of implantation of an implantable cardioverter/defibrillator ( ICD ) after newly diagnosed heart failure is unclear given that late reverse remodelling may occur. We aimed to analyze left ventricular ejection fraction ( LVEF ) after diagnosis of an LVEF ≤35% during optimization of heart failure drug therapy. Methods and Results One hundred fifty‐six patients with newly diagnosed LVEF ≤35% receiving a wearable cardioverter/defibrillator ( WCD ) were analyzed. WCD was prescribed for 3 months until first re‐evaluation. Indications for prolongation of WCD wearing period instead of ICD implantation were: (1) LVEF at 3‐month visit 30% to 35%; (2) increase in LVEF of ≥5% compared to the last visit; and (3) nonoptimized heart failure medication. Mean LVEF was 24±7% at diagnosis and 39±11% at last follow‐up (mean, 12±10 months). Whereas 88 patients presented a primary preventive ICD indication ( LVEF ≤35%) at 3‐month follow‐up, only 58 showed a persistent primary preventive ICD indication at last follow‐up. This delayed improvement in LVEF was related to nonischemic origin of cardiomyopathy, New York Heart Association functional class at baseline, heart rate, better LVEF after 3 months, and higher dosages of mineralocorticoid receptor antagonist. Twelve appropriate WCD shocks for ventricular tachycardia/ventricular fibrillation occurred in 11 patients. Two patients suffered from ventricular tachycardia/ventricular fibrillation beyond 3 months after diagnosis. Conclusions A relevant proportion of patients with newly diagnosed heart failure shows recovery of LVEF >35% beyond 3 months after initiation of heart failure therapy. To avoid untimely ICD implantation, prolongation of WCD period should be considered in these patients to prevent sudden cardiac death while allowing left ventricular reverse remodeling during intensified drug therapy.
Additional details
Identifiers
- OpenAlex
- W2577467549
- PMID
- 28096098
- URL
- https://www.ahajournals.org/doi/10.1161/JAHA.116.004512
Dates
- Issued
-
January 11, 2017
References
- Priori, S. G., Blomström-Lundqvist, C., Mazzanti, A., Blom, N., Borggrefe, M., Camm, J., Elliott, P. M., Fitzsimons, D., Hatala, R., Hindricks, G., Kirchhof, P., Kjeldsen, K., Kuck, K.-H., Hernandez-Madrid, A., Nikolaou, N., Norekvål, T. M., Spaulding, C., Van Veldhuisen, D. J., Group, E. S. D., … Parkhomenko, A. (2015). 2015 ESC Guidelines for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death. European Heart Journal, 36(41), 2793–2867. https://doi.org/10.1093/eurheartj/ehv316
- Ponikowski, P., Voors, A. A., Anker, S. D., Bueno, H., Cleland, J. G. F., Coats, A. J. S., Falk, V., González-Juanatey, J. R., Harjola, V.-P., Jankowska, E. A., Jessup, M., Linde, C., Nihoyannopoulos, P., Parissis, J. T., Pieske, B., Riley, J. P., Rosano, G. M. C., Ruilope, L. M., Ruschitzka, F., … Reviewers, D. (2016). 2016 ESC Guidelines for the Diagnosis and Treatment of Acute and Chronic Heart Failure. European Journal of Heart Failure, 18(8), 891–975. https://doi.org/10.1002/ejhf.592
- Hohnloser, S. H., Kuck, K. H., Dorian, P., Roberts, R. S., Hampton, J. R., Hatala, R., Fain, E., Gent, M., & Connolly, S. J. (2004). Prophylactic Use of an Implantable Cardioverter–Defibrillator after Acute Myocardial Infarction. New England Journal of Medicine, 351(24), 2481–2488. https://doi.org/10.1056/nejmoa041489
- Steinbeck, G., Andresen, D., Seidl, K., Brachmann, J., Hoffmann, E., Wojciechowski, D., Kornacewicz-Jach, Z., Sredniawa, B., Lupkovics, G., Hofgärtner, F., Lubinski, A., Rosenqvist, M., Habets, A., Wegscheider, K., & Senges, J. (2009). Defibrillator Implantation Early after Myocardial Infarction. New England Journal of Medicine, 361(15), 1427–1436. https://doi.org/10.1056/nejmoa0901889
- Sheppard, R., Mather, P. J., Alexis, J. D., Starling, R. C., Boehmer, J. P., Thohan, V., Pauly, D. F., Markham, D. W., Zucker, M., Kip, K. E., & McNamara, D. M. (2012). Implantable Cardiac Defibrillators and Sudden Death in Recent Onset Nonischemic Cardiomyopathy: Results From IMAC2. Journal of Cardiac Failure, 18(9), 675–681. https://doi.org/10.1016/j.cardfail.2012.07.004
- Solomon, S. D., Zelenkofske, S., McMurray, J. J. V., Finn, P. V., Velazquez, E., Ertl, G., Harsanyi, A., Rouleau, J. L., Maggioni, A., Kober, L., White, H., Van de Werf, F., Pieper, K., Califf, R. M., & Pfeffer, M. A. (2005). Sudden Death in Patients with Myocardial Infarction and Left Ventricular Dysfunction, Heart Failure, or Both. New England Journal of Medicine, 352(25), 2581–2588. https://doi.org/10.1056/nejmoa043938
- Sjöblom, J., Muhrbeck, J., Witt, N., Alam, M., & Frykman-Kull, V. (2014). Evolution of Left Ventricular Ejection Fraction After Acute Myocardial Infarction. Circulation, 130(9), 743–748. https://doi.org/10.1161/circulationaha.114.009924
- BERTHELOT‐RICHER, M., BONENFANT, F., CLAVEL, M., FARAND, P., PHILIPPON, F., AYALA‐PAREDES, F., ESSADIQI, B., BADRA‐VERDU, M. G., & ROUX, J. (2016). Arrhythmic Risk Following Recovery of Left Ventricular Ejection Fraction in Patients with Primary Prevention ICD. Pacing and Clinical Electrophysiology, 39(7), 680–689. https://doi.org/10.1111/pace.12868
- Duncker D, Veltman C. The wearable cardioverter/defibrillator—Toy or Tool? J Atr Fibrillation. 2016;8:69–77.
- Members, A. F., McMurray, J. J. V., Adamopoulos, S., Anker, S. D., Auricchio, A., Böhm, M., Dickstein, K., Falk, V., Filippatos, G., Fonseca, C., Gomez-Sanchez, M. A., Jaarsma, T., Køber, L., Lip, G. Y. H., Maggioni, A. P., Parkhomenko, A., Pieske, B. M., Popescu, B. A., Rønnevik, P. K., … Ponikowski, P. (2012). ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure 2012. European Heart Journal, 33(14), 1787–1847. https://doi.org/10.1093/eurheartj/ehs104
- Schmidt, S., Hurlimann, D., Starck, C. T., Hindricks, G., Luscher, T. F., Ruschitzka, F., & Steffel, J. (2013). Treatment with higher dosages of heart failure medication is associated with improved outcome following cardiac resynchronization therapy. European Heart Journal, 35(16), 1051–1060. https://doi.org/10.1093/eurheartj/eht514
- Fonarow, G. C., Yancy, C. W., Hernandez, A. F., Peterson, E. D., Spertus, J. A., & Heidenreich, P. A. (2011). Potential impact of optimal implementation of evidence-based heart failure therapies on mortality. American Heart Journal, 161(6), 1024–1030.e3. https://doi.org/10.1016/j.ahj.2011.01.027
- Brooks, G. C., Lee, B. K., Rao, R., Lin, F., Morin, D. P., Zweibel, S. L., Buxton, A. E., Pletcher, M. J., Vittinghoff, E., & Olgin, J. E. (2016). Predicting Persistent Left Ventricular Dysfunction Following Myocardial Infarction. Journal of the American College of Cardiology, 67(10), 1186–1196. https://doi.org/10.1016/j.jacc.2015.12.042
- McNamara, D. M., Starling, R. C., Cooper, L. T., Boehmer, J. P., Mather, P. J., Janosko, K. M., Gorcsan, J., Kip, K. E., & Dec, G. W. (2011). Clinical and Demographic Predictors of Outcomes in Recent Onset Dilated Cardiomyopathy. Journal of the American College of Cardiology, 58(11), 1112–1118. https://doi.org/10.1016/j.jacc.2011.05.033
- Kini, V., Soufi, M. K., Deo, R., Epstein, A. E., Bala, R., Riley, M., Groeneveld, P. W., Shalaby, A., & Dixit, S. (2014). Appropriateness of Primary Prevention Implantable Cardioverter-Defibrillators at the Time of Generator Replacement. Journal of the American College of Cardiology, 63(22), 2388–2394. https://doi.org/10.1016/j.jacc.2014.03.025
- Grimm, W., Timmesfeld, N., & Efimova, E. (2013). Left ventricular function improvement after prophylactic implantable cardioverter-defibrillator implantation in patients with non-ischaemic dilated cardiomyopathy. Europace, 15(11), 1594–1600. https://doi.org/10.1093/europace/eut097
- Al-Khatib, S. M. (2011). Non–Evidence-Based ICD Implantations in the United States. JAMA, 305(1), 43. https://doi.org/10.1001/jama.2010.1915
- Kleemann, T., Becker, T., Doenges, K., Vater, M., Senges, J., Schneider, S., Saggau, W., Weisse, U., & Seidl, K. (2007). Annual Rate of Transvenous Defibrillation Lead Defects in Implantable Cardioverter-Defibrillators Over a Period of >10 Years. Circulation, 115(19), 2474–2480. https://doi.org/10.1161/circulationaha.106.663807
- van der Heijden, A. C., Borleffs, C. J. W., Buiten, M. S., Thijssen, J., van Rees, J. B., Cannegieter, S. C., Schalij, M. J., & van Erven, L. (2015). The clinical course of patients with implantable cardioverter-defibrillators: Extended experience on clinical outcome, device replacements, and device-related complications. Heart Rhythm, 12(6), 1169–1176. https://doi.org/10.1016/j.hrthm.2015.02.035
- Wilber, D. J., Zareba, W., Hall, W. J., Brown, M. W., Lin, A. C., Andrews, M. L., Burke, M., & Moss, A. J. (2004). Time Dependence of Mortality Risk and Defibrillator Benefit After Myocardial Infarction. Circulation, 109(9), 1082–1084. https://doi.org/10.1161/01.cir.0000121328.12536.07
- Maggioni, A. P., Anker, S. D., Dahlström, U., Filippatos, G., Ponikowski, P., Zannad, F., Amir, O., Chioncel, O., Leiro, M. C., Drozdz, J., Erglis, A., Fazlibegovic, E., Fonseca, C., Fruhwald, F., Gatzov, P., Goncalvesova, E., Hassanein, M., Hradec, J., Kavoliuniene, A., … Tavazzi, L. (2013). Are Hospitalized or Ambulatory Patients with Heart Failure Treated in Accordance with European Society of Cardiology Guidelines? Evidence from 12 440 Patients of the ESC Heart Failure Long-Term Registry. European Journal of Heart Failure, 15(10), 1173–1184. https://doi.org/10.1093/eurjhf/hft134
- Güder, G., Störk, S., Gelbrich, G., Brenner, S., Deubner, N., Morbach, C., Wallenborn, J., Berliner, D., Ertl, G., & Angermann, C. E. (2015). Nurse-Coordinated Collaborative Disease Management Improves the Quality of Guideline-Recommended Heart Failure Therapy, Patient-Reported Outcomes, and Left Ventricular Remodelling. European Journal of Heart Failure, 17(4), 442–452. https://doi.org/10.1002/ejhf.252
- Duncker, D., Haghikia, A., König, T., Hohmann, S., Gutleben, K.-J., Westenfeld, R., Oswald, H., Klein, H., Bauersachs, J., Hilfiker-Kleiner, D., & Veltmann, C. (2014). Risk for Ventricular Fibrillation in Peripartum Cardiomyopathy with Severely Reduced Left Ventricular Function—Value of the Wearable Cardioverter/Defibrillator. European Journal of Heart Failure, 16(12), 1331–1336. https://doi.org/10.1002/ejhf.188
- Schwab, J. O., Bänsch, D., Israel, C., & Nowak, B. (2015). Stellungnahme zum Einsatz des tragbaren Kardioverter/Defibrillators. Der Kardiologe, 9(2), 165–170. https://doi.org/10.1007/s12181-015-0651-y
- Piccini, J. P., Allen, L. A., Kudenchuk, P. J., Page, R. L., Patel, M. R., & Turakhia, M. P. (2016). Wearable Cardioverter-Defibrillator Therapy for the Prevention of Sudden Cardiac Death. Circulation, 133(17), 1715–1727. https://doi.org/10.1161/cir.0000000000000394
1–25 of 27
Citations
- Landra, F., Curti, E., Falasconi, G., Penela, D., Bergonti, M., Saglietto, A., Benali, K., Latini, A. C., Turturiello, D., Soto-Iglesias, D., Santoro, A., Taravelli, E., Rossi, A., Martí-Almor, J., Conte, G., Anselmino, M., Vernooy, K., & Berruezo, A. (2026). Impact of atrial fibrillation catheter ablation on primary prevention ICD eligibility in heart failure with reduced ejection fraction: a systematic review and meta-analysis. Journal of Interventional Cardiac Electrophysiology, 69(6), 1405–1420. https://doi.org/10.1007/s10840-026-02302-0
- Buter, J., DeVore, A., Januzzi, J. L., Khan, M. S., Lala, A., & Metra, M. (2026). Early Sudden Cardiac Death Risk in Heart Failure: Time to Rethink Primary Prevention?. Journal of Cardiac Failure. https://doi.org/10.1016/j.cardfail.2026.09.037
- Ba, D. B., Rioux, M.-A., Mondésert, B., Parent, M.-C., Fortier, A., Todd, J., Jarjour, M., O’Meara, E., & Ducharme, A. (2026). Adherence to Guidelines in Patients With Heart Failure and Reduced Ejection Fraction Before Defibrillator Implantation. CJC Open, 8(11), 1497–1505. https://doi.org/10.1016/j.cjco.2026.06.014
- Velibey, Y., Kahraman, E., Borklu, E. B., Karatas, M. B., Guvenc, T. S., & Bolca, O. (2026). Delayed ejection fraction recovery in the era of contemporary guideline-directed medical therapy: Is the conventional 3-month waiting period for device therapy still enough?. Acta Cardiologica, 1–4. https://doi.org/10.1080/00015385.2026.2714628
- Sliwa, K., Viljoen, C., Hoevelmann, J., Rakisheva, A., Ali Farhan, H., Damasceno, A., Jessen, N., Jovanova, S., Mbakwem, A., Simpson, M., Jackson, A. M., Petrie, M. C., van der Meer, P., Van Craenenbroeck, E., Kahl, K. G., Tschöpe, C., Sinagra, G., Seferovic, P., Bayes-Genis, A., & Bauersachs, J. (2026). Access to medical care globally for patients with peripartum cardiomyopathy: a clinical consensus statement of the Heart Failure Association of the ESC. European Journal of Heart Failure. https://doi.org/10.1093/ejhf/xuag024
- Yogarajah, J., Dannebaum, J., Halim, A., Sedighi, J., Mensch, M., Kuniss, M., Neumann, T., Rieth, A., Treiber, J., Sossalla, S., & Hain, A. (2026). Prevalence and Recovery of Arrhythmia‐Induced Cardiomyopathy in Patients With Newly Diagnosed Heart Failure Using a Wearable Defibrillator: A Real‐World Cohort Study. Journal of Cardiovascular Electrophysiology, 37(7), 1465–1475. https://doi.org/10.1111/jce.70366
- Duncker, D., & Marijon, E. (2026). Protecting the Vulnerable Phase in Newly Diagnosed Heart Failure. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.70561
- Matteucci, A., Bonanni, M., Mariani, M. V., Sgarra, L., Nesti, L., Pierucci, N., Di Fusco, S. A., Fedele, S., Nardi, F., & Colivicchi, F. (2026). Wearable Cardioverter-Defibrillator in Patients at Transient Risk of Sudden Cardiac Death: State of the Art and Contemporary Clinical Evidence. Diagnostics, 16(18), 2990. https://doi.org/10.3390/diagnostics16182990
- Jakstaite, A. M., Mueller-Leisse, J., Hillmann, H. A. K., Hohmann, S., Eiringhaus, J., Bavendiek, U., Kempf, T., Veltmann, C., Bauersachs, J., Duncker, D., & Berliner, D. (2025). Right Ventricular Dysfunction for Prediction of Long-Term Recovery in de novo HFrEF : A PROLONG-II Substudy. ESC Heart Failure, 12(3), 2166–2176. https://doi.org/10.1002/ehf2.15236
- Malgie, J., Wilde, M. I., Koudstaal, S., Denham, R., da Fonseca, C. A., Swart, H. P., van Ofwegen, C. E. E., Yilmaz, A., Pisters, R., Linssen, G. C. M., Faber, N., van Heerebeek, L., van de Swaluw, J. E. C., de Boer, R. A., Brunner-La Rocca, H.-P., & Brugts, J. J. (2025). Real-Life Implementation of Guideline-Recommended Medical Therapy in Heart Failure with Reduced Ejection Fraction: Effects on Prognosis and Left Ventricular Ejection Fraction. Primary results of TITRATE-HF. European Journal of Heart Failure, 27(12), 2735–2746. https://doi.org/10.1002/ejhf.70006
- Kontogiannis, V., Goromonzi, F., Both, B., Semrau, F., Branagan-Harris, M., Atkinson, J., Roberts, P. R., & Javanbakht, M. (2025). Cost-Utility Analysis of LifeVest® in Post-Myocardial Infarction Patients at Risk of Sudden Cardiac Death in England. PharmacoEconomics - Open, 9(2), 301–312. https://doi.org/10.1007/s41669-024-00553-z
- De Backer, J., Haugaa, K. H., Hasselberg, N. E., de Hosson, M., Brida, M., Castelletti, S., Cauldwell, M., Cerbai, E., Crotti, L., de Groot, N. M. S., Estensen, M.-E., Goossens, E. S., Haring, B., Kurpas, D., McEniery, C. M., Peters, S. A. E., Rakisheva, A., Sambola, A., Schlager, O., … Zakirova, F. (2025). 2025 ESC Guidelines for the management of cardiovascular disease and pregnancy. European Heart Journal, 46(43), 4462–4568. https://doi.org/10.1093/eurheartj/ehaf193
- Duncker, D., Marijon, E., Metra, M., Piot, O., Fudim, M., Siebert, U., Frey, N., Maier, L. S., & Bauersachs, J. (2025). Sudden cardiac death in newly diagnosed non-ischaemic or ischaemic cardiomyopathy assessed with a wearable cardioverter-defibrillator: the German nationwide SCD-PROTECT study. European Heart Journal, 46(43), 4597–4606. https://doi.org/10.1093/eurheartj/ehaf668
- Migliore, F., Perrotta, L., Mills, M. T., Anic, A., Sultan, A., Futyma, P., Mazurek, M., Nesti, M., Duray, G. Z., Pittorru, R., & Chun, J. K. R. (2025). Role of the wearable cardioverter defibrillator in the initial period of sudden cardiac death risk stratification: results of a European Heart Rhythm Association survey. Europace, 27(7). https://doi.org/10.1093/europace/euaf118
- Duncker, D., Garcia, R., Bonderman, D., Casolo, G., Farkowski, M., Israel, C., & Marijon, E. (2025). A review on wearable cardioverter-defibrillators in clinical practice for sudden cardiac death prevention and heart failure management. Europace, 27(11). https://doi.org/10.1093/europace/euaf257
- Adebayo, M., & Zadinsky, J. (2025). Evaluation of Quality-of-Life Assessment Instruments for Heart Failure Patients. CIN: Computers, Informatics, Nursing. https://doi.org/10.1097/cin.0000000000001371
- Tanaka, Y., Kitano, D., Yoda, S., Mizobuchi, S., Miyagawa, M., Fukumoto, K., Fujito, H., Hatta, T., Saito, Y., Toyama, K., & Okumura, Y. (2025). Stress phase bandwidth as a predictor of left ventricular reverse remodeling in patients with new-onset acute decompensated heart failure with reduced ejection fraction. BMC Cardiovascular Disorders, 25(1). https://doi.org/10.1186/s12872-025-04548-4
- Wanezaki, M., Watanabe, T., Iizuka, A., Kobayashi, T., Edamura, S., Sugai, T., Tamura, H., Nishiyama, S., Yamaguchi, R., Hashimoto, N., Otaki, Y., Kutsuzawa, D., Kato, S., Arimoto, T., Inoue, S., Ko, T., Nomura, S., Komuro, I., & Watanabe, M. (2025). Recent Trends in Achievement Rates and Time Required for Left Ventricular Reverse Remodeling in Dilated Cardiomyopathy. Circulation Reports, 7(2), 97–105. https://doi.org/10.1253/circrep.cr-24-0148
- Shchendrygina, A., Yehya, A., & Skouri, H. (2025). The Timing for Primary Prevention for ICD in the Current Era of Pharmacotherapy. Cardiac Failure Review, 11. https://doi.org/10.15420/cfr.2025.05
- Dell'Era, G., Caimmi, P., Spinoni, E. G., Battistini, E., Porcellini, S., De Vecchi, F., Santagostino, M., Ghiglieno, C., Degiovanni, A., Leigheb, F., Kozel, D., Capponi, A., & Patti, G. (2024). Wearable Defibrillator to Improve Accuracy in Selecting Candidates to Implantable Defibrillator: A Real-World Experience. ESC Heart Failure, 11(6), 3993–3999. https://doi.org/10.1002/ehf2.14840
- Sliwa, K., Rakisheva, A., Viljoen, C., Pfeffer, T., Simpson, M., Jackson, A. M., Petrie, M. C., van der Meer, P., Al Farhan, H., Jovanova, S., Mbakwem, A., Sinagra, G., Van Craenenbroeck, E., Hoevelmann, J., Johnson, M. R., Mindham, R., Chioncel, O., Kahl, K. G., Rosano, G., … Bauersachs, J. (2024). Living with Peripartum Cardiomyopathy: A Statement from the Heart Failure Association and the Association of Cardiovascular Nursing and Allied Professions of the European Society of Cardiology. European Journal of Heart Failure, 26(10), 2143–2154. https://doi.org/10.1002/ejhf.3377
- Kreimer, F., Koepsel, K., Gotzmann, M., Kovacs, B., Dreher, T. C., Blockhaus, C., Klein, N., Kuntz, T., Shin, D.-I., Lapp, H., Rosenkaimer, S., Abumayyaleh, M., Hamdani, N., Saguner, A. M., Erath, J. W., Duru, F., Beiert, T., Schiedat, F., Weth, C., … El-Battrawy, I. (2024). Predictors of ventricular tachyarrhythmia in patients with a wearable cardioverter defibrillator: an international multicenter registry. Journal of Interventional Cardiac Electrophysiology, 67(8), 1917–1928. https://doi.org/10.1007/s10840-024-01869-w
- Sánchez, C. L. (2024). Peripartum cardiomyopathy. In Critical Heart Condition During Pregnancy (pp. 101–107). Elsevier. https://doi.org/10.1016/b978-0-443-22008-1.00003-8
- Weipert, K. F., Chasan, R., Gündüz, D., Roussopoulos, K., Rosenbauer, J., & Erkapic, D. (2024). Repetitive ineffective shock delivery with max 6 joules of a wearable defibrillator during ventricular fibrillation with lethal consequences. HeartRhythm Case Reports, 10(5), 341–345. https://doi.org/10.1016/j.hrcr.2024.02.012
- Chen, Q.-F., Lu, Y., Katsouras, C. S., Peng, Y., Sun, J., Li, M., Liu, C., Yao, H., Lian, L., Feng, X., Lin, W.-H., & Zhou, X.-D. (2024). Characteristics, outcomes and the necessity of continued guideline-directed medical therapy in patients with heart failure with improved ejection fraction. Annals of Medicine, 57(1). https://doi.org/10.1080/07853890.2024.2442535
1–25 of 86