Published July 10, 2025 | Journal article | Version v1 | https://doi.org/10.3389/fimmu.2025.1601742

PET imaging of tissue reactions in the implanted cochlea: results of a pilot study

Description

PurposeAfter cochlear implantation, molecular processes at the electrode–nerve interface significantly influence the variability in clinical outcomes. The present study investigates molecular processes in a guinea pig model of cochlear implant (CI) using positron emission tomography/computed tomography (PET/CT) and correlates the imaging findings with histological analyses.MethodsAnimals were examined with PET in the 3 weeks and 9–12 months post-implantation using the inflammation marker [18F]FDG and, at the later time points, [68Ga]FAPI-46 as a marker for fibrosis. Tracer accumulation in the cochlea was determined from PET imaging based on the co-registered CT. Nine animals (seven with unilateral CI) were included. Uptake in non-implanted cochleae served as reference. Tissue growth around the implant was evaluated histologically.ResultsPost-implantation, [18F]FDG uptake was significantly increased when pooling early and late in investigation time points, while after 1 year, [68Ga]FAPI-46 uptake was increased inside the cochlear. Cochlear volumes measured by CT did not show significant differences between compared groups. Tissue growth around the implant was observed in all animals, with a trend toward increased growth associated with insertion depth. However, no clear correlation was observed between the extent of tissue growth and the uptake intensities of FDG and FAPI.DiscussionThe data indicate that increased accumulation of PET biomarkers in the cochlea after implantation can be detected in guinea pigs using a dedicated PET/CT. Given the high resolution of current clinical PET/CT devices, this method is expected to be suitable for use in patients, particularly for assessing the effect of anti-inflammatory or anti-fibrotic therapies.

Files

fimmu.2025.1601742.pdf

Files (5.3 MB)

Name Size Download all
md5:a71f56a33354496382fe82dc9affca55
5.3 MB Preview Download

Additional details

Dates

Issued
July 10, 2025

References

  1. Lenarz, T. (2018). Cochlear implant – state of the art. GMS Current Topics in Otorhinolaryngology - Head and Neck Surgery; 16:Doc04. https://doi.org/10.3205/cto000143
  2. Carlson, M. L. (2020). Cochlear Implantation in Adults. New England Journal of Medicine, 382(16), 1531–1542. https://doi.org/10.1056/nejmra1904407
  3. Holden, L. K., Finley, C. C., Firszt, J. B., Holden, T. A., Brenner, C., Potts, L. G., Gotter, B. D., Vanderhoof, S. S., Mispagel, K., Heydebrand, G., & Skinner, M. W. (2013). Factors Affecting Open-Set Word Recognition in Adults With Cochlear Implants. Ear & Hearing, 34(3), 342–360. https://doi.org/10.1097/aud.0b013e3182741aa7
  4. Hendricks, J. L., Chikar, J. A., Crumling, M. A., Raphael, Y., & Martin, D. C. (2008). Localized cell and drug delivery for auditory prostheses. Hearing Research, 242(1-2), 117–131. https://doi.org/10.1016/j.heares.2008.06.003
  5. Wilk, M., Hessler, R., Mugridge, K., Jolly, C., Fehr, M., Lenarz, T., Scheper, V., & Yamamoto, M. (2016). Impedance Changes and Fibrous Tissue Growth after Cochlear Implantation Are Correlated and Can Be Reduced Using a Dexamethasone Eluting Electrode. PLOS ONE, 11(2), e0147552. https://doi.org/10.1371/journal.pone.0147552
  6. Braack, K. J., Miles, T., Amat, F., Brown, D. J., Atlas, M. D., Kuthubutheen, J., Mulders, W. H. A. M., & Prêle, C. M. (2023). Using x-ray micro computed tomography to quantify intracochlear fibrosis after cochlear implantation in a Guinea pig model. Heliyon, 9(9), Article e19343. https://doi.org/10.1016/j.heliyon.2023.e19343
  7. Heutink, F., Klabbers, T. M., Huinck, W. J., Lucev, F., van der Woude, W. J., Mylanus, E. A. M., & Verbist, B. M. (2022). Ultra-High-Resolution CT to Detect Intracochlear New Bone Formation after Cochlear Implantation. Radiology, 302(3), 605–612. https://doi.org/10.1148/radiol.211400
  8. Casali, M., Lauri, C., Altini, C., Bertagna, F., Cassarino, G., Cistaro, A., Erba, A. P., Ferrari, C., Mainolfi, C. G., Palucci, A., Prandini, N., Baldari, S., Bartoli, F., Bartolomei, M., D’Antonio, A., Dondi, F., Gandolfo, P., Giordano, A., Laudicella, R., … Signore, A. (2021). State of the art of 18F-FDG PET/CT application in inflammation and infection: a guide for image acquisition and interpretation. Clinical and Translational Imaging, 9(4), 299–339. https://doi.org/10.1007/s40336-021-00445-w
  9. Bentestuen, M., Al-Obaydi, N., & Zacho, H. D. (2023). FAPI-avid nonmalignant PET/CT findings: An expedited systematic review. Seminars in Nuclear Medicine, 53(5), 694–705. https://doi.org/10.1053/j.semnuclmed.2023.02.001
  10. Schmidkonz, C., Kuwert, T., Atzinger, A., Cordes, M., Schett, G., Ramming, A., & Götz, T. (2022). Fibroblast Activation Protein Inhibitor Imaging in Nonmalignant Diseases: A New Perspective for Molecular Imaging. Journal of Nuclear Medicine, 63(12), 1786–1792. https://doi.org/10.2967/jnumed.122.264205
  11. Shi, X. (2016). Pathophysiology of the cochlear intrastrial fluid-blood barrier (review). Hearing Research, 338, 52–63. https://doi.org/10.1016/j.heares.2016.01.010
  12. Sun, W., & Wang, W. (2015). Advances in research on labyrinth membranous barriers. Journal of Otology, 10(3), 99–104. https://doi.org/10.1016/j.joto.2015.11.003
  13. Guedj, E., Varrone, A., Boellaard, R., Albert, N. L., Barthel, H., van Berckel, B., Brendel, M., Cecchin, D., Ekmekcioglu, O., Garibotto, V., Lammertsma, A. A., Law, I., Peñuelas, I., Semah, F., Traub-Weidinger, T., van de Giessen, E., Van Weehaeghe, D., & Morbelli, S. (2021). EANM procedure guidelines for brain PET imaging using [18F]FDG, version 3. European Journal of Nuclear Medicine and Molecular Imaging, 49(2), 632–651. https://doi.org/10.1007/s00259-021-05603-w
  14. Zhao, L., Niu, B., Fang, J., Pang, Y., Li, S., Xie, C., Sun, L., Zhang, X., Guo, Z., Lin, Q., & Chen, H. (2021). Synthesis, Preclinical Evaluation, and a Pilot Clinical PET Imaging Study of 68 Ga-Labeled FAPI Dimer. Journal of Nuclear Medicine, 63(6), 862–868. https://doi.org/10.2967/jnumed.121.263016
  15. Ohlemiller, K. K., Dwyer, N., Henson, V., Fasman, K., & Hirose, K. (2024). A critical evaluation of "leakage" at the cochlear blood-stria-barrier and its functional significance. Frontiers in Molecular Neuroscience, 17. https://doi.org/10.3389/fnmol.2024.1368058
  16. Sekulic, M., Puche, R., Bodmer, D., & Petkovic, V. (2023). Human blood-labyrinth barrier model to study the effects of cytokines and inflammation. Frontiers in Molecular Neuroscience, 16. https://doi.org/10.3389/fnmol.2023.1243370
  17. Iyer, J. S., Batts, S. A., Chu, K. K., Sahin, M. I., Leung, H. M., Tearney, G. J., & Stankovic, K. M. (2016). Micro-optical coherence tomography of the mammalian cochlea. Scientific Reports, 6(1). https://doi.org/10.1038/srep33288
  18. Measurements of selected parameters of the Guinea pig temporal bone
  19. Constantinescu, C. C., & Mukherjee, J. (2009). Performance evaluation of an Inveon PET preclinical scanner. Physics in Medicine and Biology, 54(9), 2885–2899. https://doi.org/10.1088/0031-9155/54/9/020
  20. Goertzen, A. L., Bao, Q., Bergeron, M., Blankemeyer, E., Blinder, S., Cañadas, M., Chatziioannou, A. F., Dinelle, K., Elhami, E., Jans, H.-S., Lage, E., Lecomte, R., Sossi, V., Surti, S., Tai, Y.-C., Vaquero, J. J., Vicente, E., Williams, D. A., & Laforest, R. (2012). NEMA NU 4-2008 Comparison of Preclinical PET Imaging Systems. Journal of Nuclear Medicine, 53(8), 1300–1309. https://doi.org/10.2967/jnumed.111.099382
  21. Knoop, B. O., Geworski, L., Hofmann, M., Munz, D. L., & Knapp, W. H. (2002). Use of recovery coefficients as a test of system linearity of response in positron emission tomography (PET). Physics in Medicine and Biology, 47(8), 1237–1254. https://doi.org/10.1088/0031-9155/47/8/302
  22. Behrends, W., Wulf, K., Raggl, S., Fröhlich, M., Eickner, T., Dohr, D., Esser, K.-H., Lenarz, T., Scheper, V., & Paasche, G. (2023). Dual Drug Delivery in Cochlear Implants: In Vivo Study of Dexamethasone Combined with Diclofenac or Immunophilin Inhibitor MM284 in Guinea Pigs. Pharmaceutics, 15(3), 726. https://doi.org/10.3390/pharmaceutics15030726
  23. Round window versus cochleostomy technique in cochlear implantation: Histologic findings https://doi.org/10.1097/mao.0b013e318263d56d24
  24. Behrends, W., Ahrens, D., Bankstahl, J. P., Esser, K.-H., Paasche, G., Lenarz, T., & Scheper, V. (2023). Refinement of systemic guinea pig deafening in hearing research: Sensorineural hearing loss induced by co-administration of kanamycin and furosemide via the leg veins. Laboratory Animals, 57(6), 631–641. https://doi.org/10.1177/00236772231167679
  25. Lexow, G. J., Schurzig, D., Gellrich, N.-C., Lenarz, T., Majdani, O., & Rau, T. S. (2016). Visualization, measurement and modelling of the cochlea using rotating midmodiolar slice planes. International Journal of Computer Assisted Radiology and Surgery, 11(10), 1855–1869. https://doi.org/10.1007/s11548-016-1374-7

1–25 of 62