Perspective review of optical imaging in welfare assessment in animal-based research
Authors/Creators
-
1.
RWTH Aachen University
-
2.
Medizinische Hochschule Hannover
- 3. Georg-August-Univ. Göttingen
Description
To refine animal research, vital signs, activity, stress, and pain must be monitored. In chronic studies, some measures can be assessed using telemetry sensors. Although this methodology provides high-precision data, an initial surgery for device implantation is necessary, potentially leading to stress, wound infections, and restriction of motion. Recently, camera systems have been adapted for animal research. We give an overview of parameters that can be assessed using imaging in the visible, near-infrared, and thermal spectrum of light. It focuses on heart activity, respiration, oxygen saturation, and motion, as well as on wound analysis. For each parameter, we offer recommendations on the minimum technical requirements of appropriate systems, regions of interest, and light conditions, among others. In general, these systems demonstrate great performance. For heart and respiratory rate, the error was <4 beats / min and 5 breaths/min. Furthermore, the systems are capable of tracking animals during different behavioral tasks. Finally, studies indicate that inhomogeneous temperature distribution around wounds might be an indicator of (pending) infections. In sum, camera-based techniques have several applications in animal research. As vital parameters are currently only assessed in sedated animals, the next step should be the integration of these modalities in home-cage monitoring.
Additional details
Identifiers
Funding
- German Research Foundation
- CZ 215/3-1
- German Research Foundation
- BL953/10-1
- German Research Foundation
- TH903/22-1
- German Research Foundation
- TO 542/5-1
- German Research Foundation
- KI1072/20-1
- German Research Foundation
- LI 588/5-1
- German Research Foundation
- TR 447/5-1
-
Deutsche Forschungsgemeinschaft
- 542/5-1
-
Deutsche Forschungsgemeinschaft
- FOR 2591: Severity assessment in animalbased research 321137804
-
Deutsche Forschungsgemeinschaft
- FOR2591
Dates
- Issued
-
July 8, 2019
References
- Baumans, V. (2004). Use of animals in experimental research: an ethical dilemma?. Gene Therapy, 11(S1), S64–S66. https://doi.org/10.1038/sj.gt.3302371
- Festing, S., & Wilkinson, R. (2007). The ethics of animal research. The EMBO Reports, 8(6), 526–530. https://doi.org/10.1038/sj.embor.7400993
- Seventh report on the statistics on the number of animals used for experimental and other scientific purposes in the member states of the European Union
- Roelfsema, P. R., & Treue, S. (2014). Basic Neuroscience Research with Nonhuman Primates: A Small but Indispensable Component of Biomedical Research. Neuron, 82(6), 1200–1204. https://doi.org/10.1016/j.neuron.2014.06.003
- Mutlu, K., Rabell, J. E., Martin del Olmo, P., & Haesler, S. (2018). IR thermography-based monitoring of respiration phase without image segmentation. Journal of Neuroscience Methods, 301, 1–8. https://doi.org/10.1016/j.jneumeth.2018.02.017
- Niemeyer, J. E. (2016). Telemetry for small animal physiology. Lab Animal, 45(7), 255–257. https://doi.org/10.1038/laban.1048
- Applications of telemetry in small laboratory animals for studying cardiovascular diseases
- Mouse physiology
- Barbosa Pereira, C., Kunczik, J., Zieglowski, L., Tolba, R., Abdelrahman, A., Zechner, D., Vollmar, B., Janssen, H., Thum, T., & Czaplik, M. (2018). Remote Welfare Monitoring of Rodents Using Thermal Imaging. Sensors, 18(11), 3653. https://doi.org/10.3390/s18113653
- González-Sánchez, C., Fraile, J.-C., Pérez-Turiel, J., Damm, E., Schneider, J., Zimmermann, H., Schmitt, D., & Ihmig, F. (2016). Capacitive Sensing for Non-Invasive Breathing and Heart Monitoring in Non-Restrained, Non-Sedated Laboratory Mice. Sensors, 16(7), 1052. https://doi.org/10.3390/s16071052
- Pereira, C. B., Yu, X., Czaplik, M., Rossaint, R., Blazek, V., & Leonhardt, S. (2015). Remote monitoring of breathing dynamics using infrared thermography. Biomedical Optics Express, 6(11), 4378. https://doi.org/10.1364/boe.6.004378
- Barbosa Pereira, C., Czaplik, M., Blazek, V., Leonhardt, S., & Teichmann, D. (2018). Monitoring of Cardiorespiratory Signals Using Thermal Imaging: A Pilot Study on Healthy Human Subjects. Sensors, 18(5), 1541. https://doi.org/10.3390/s18051541
- Knobel, R. B., Guenther, B. D., & Rice, H. E. (2011). Thermoregulation and Thermography in Neonatal Physiology and Disease. Biological Research For Nursing, 13(3), 274–282. https://doi.org/10.1177/1099800411403467
- Pereira, C. B., Czaplik, M., Blanik, N., Rossaint, R., Blazek, V., & Leonhardt, S. (2014). Contact-free monitoring of circulation and perfusion dynamics based on the analysis of thermal imagery. Biomedical Optics Express, 5(4), 1075. https://doi.org/10.1364/boe.5.001075
- Detecting pulse from head motions in video
- Li, M. H., Yadollahi, A., & Taati, B. (2017). Noncontact Vision-Based Cardiopulmonary Monitoring in Different Sleeping Positions. IEEE Journal of Biomedical and Health Informatics, 21(5), 1367–1375. https://doi.org/10.1109/jbhi.2016.2567298
- Poh, M.-Z., McDuff, D. J., & Picard, R. W. (2010). Non-contact, automated cardiac pulse measurements using video imaging and blind source separation. Optics Express, 18(10), 10762. https://doi.org/10.1364/oe.18.010762
- Zhao, F., Li, M., Qian, Y., Tsien, J. Z., & Androulakis, I. P. (2013). Remote Measurements of Heart and Respiration Rates for Telemedicine. PLoS ONE, 8(10), e71384. https://doi.org/10.1371/journal.pone.0071384
- Remote photopletysmographic imaging of dermal perfusion in a porcine animal model
- Unakafov, A. M., Möller, S., Kagan, I., Gail, A., Treue, S., Wolf, F., & Matsumura, K. (2018). Using imaging photoplethysmography for heart rate estimation in non-human primates. PLOS ONE, 13(8), e0202581. https://doi.org/10.1371/journal.pone.0202581
- Reyes, B. A., Reljin, N., Kong, Y., Nam, Y., & Chon, K. H. (2017). Tidal Volume and Instantaneous Respiration Rate Estimation using a Volumetric Surrogate Signal Acquired via a Smartphone Camera. IEEE Journal of Biomedical and Health Informatics, 21(3), 764–777. https://doi.org/10.1109/jbhi.2016.2532876
- Pereira, C. B., Yu, X., Goos, T., Reiss, I., Orlikowsky, T., Heimann, K., Venema, B., Blazek, V., Leonhardt, S., & Teichmann, D. (2019). Noncontact Monitoring of Respiratory Rate in Newborn Infants Using Thermal Imaging. IEEE Transactions on Biomedical Engineering, 66(4), 1105–1114. https://doi.org/10.1109/tbme.2018.2866878
- Jin Fei, & Pavlidis, I. (2010). Thermistor at a Distance: Unobtrusive Measurement of Breathing. IEEE Transactions on Biomedical Engineering, 57(4), 988–998. https://doi.org/10.1109/tbme.2009.2032415
- Barbosa Pereira, C., Yu, X., Czaplik, M., Blazek, V., Venema, B., & Leonhardt, S. (2016). Estimation of breathing rate in thermal imaging videos: a pilot study on healthy human subjects. Journal of Clinical Monitoring and Computing, 31(6), 1241–1254. https://doi.org/10.1007/s10877-016-9949-y
- Vainer, B. G. (2018). A Novel High-Resolution Method for the Respiration Rate and Breathing Waveforms Remote Monitoring. Annals of Biomedical Engineering, 46(7), 960–971. https://doi.org/10.1007/s10439-018-2018-6
1–25 of 37
Citations
- Reddy, S. S. P., Francis, D. L., Thakur, V. K., Manohar, B., Pradhan, S., & Rai, S. (2026). A self‐retaining mouth prop for intraoral access during periodontal surgery in rat models: A technical note. Animal Models and Experimental Medicine. https://doi.org/10.1002/ame2.70300
- Brandwein, C., Leenaars, C. H., Iorgu, A.-M., Becker, L., Pfeiffer, N., Vasilescu, A.-N., Cilurzo, C., Bleich, A., Talbot, S. R., Gass, P., & Mallien, A. S. (2026). Mapping the Evolution of the Rat Forced Swim Test across Interpretation, Welfare and Pharmacology. Pharmacological Research, Article 108146. https://doi.org/10.1016/j.phrs.2026.108146
- https://doi.org/10.3390/microorganisms12040833
- He, R., Shen, L., Wang, Z., Wang, G., Qu, H., Hu, X., & Min, R. (2023). Optical fiber sensors for heart rate monitoring: A review of mechanisms and applications. Results in Optics, 11, Article 100386. https://doi.org/10.1016/j.rio.2023.100386
- https://doi.org/10.1371/journal.pone.0286230
- https://doi.org/10.3389/fvets.2023.1086003
- https://doi.org/10.1145/3565995.3566039
- https://doi.org/10.1242/jeb.243474
- https://doi.org/10.1093/ilar/ilac005
- https://doi.org/10.3390/ani11020442
- https://doi.org/10.3390/s21041200
- https://doi.org/10.1186/s13075-020-02367-w
- https://doi.org/10.3390/app9204474