Published February 2011 | Journal article | Version v1 | https://doi.org/10.1016/j.chroma.2010.12.009

Isolation and purification of blood group antigens using immuno-affinity chromatography on short monolithic columns

Additional details

Dates

Issued
February 2011

References

  1. DENOMME, G. (2004). The structure and function of the molecules that carry human red blood cell and platelet antigens☆. Transfusion Medicine Reviews, 18(3), 203–231. https://doi.org/10.1016/j.tmrv.2004.03.006
  2. Yazdanbakhsh, K., �yen, R., Yu, Q., Lee, S., Antoniou, M., Chaudhuri, A., & Reid, M. E. (2000). High-level, stable expression of blood group antigens in a heterologous system. American Journal of Hematology, 63(3), 114–124. https://doi.org/10.1002/(sici)1096-8652(200003)63:3%3C114::aid-ajh2%3E3.0.co;2-z
  3. Moulds, J. M. (2002). A review of the Knops blood group: separating fact from fallacy. Immunohematology, 18(1), 1–8. https://doi.org/10.21307/immunohematology-2019-496
  4. Moulds, J. M., & Rowe, K. E. (1996). Neutralization of Knops system antibodies using soluble complement receptor 1. Transfusion, 36(6), 517–520. https://doi.org/10.1046/j.1537-2995.1996.36696269510.x
  5. Moulds, J. M., Zimmerman, P. A., Doumbo, O. K., Kassambara, L., Sagara, I., Diallo, D. A., Atkinson, J. P., Krych-Goldberg, M., Hauhart, R. E., Hourcade, D. E., McNamara, D. T., Birmingham, D. J., Rowe, J. A., Moulds, J. J., & Miller, L. H. (2001). Molecular identification of Knops blood group polymorphisms found in long homologous region D of complement receptor 1. Blood, 97(9), 2879–2885. https://doi.org/10.1182/blood.v97.9.2879
  6. Seltsam, A., Agaylan, A., Grueger, D., Meyer, O., Blasczyk, R., & Salama, A. (2008). Rapid detection of JMH antibodies with recombinant Sema7A (CD108) protein and the particle gel immunoassay. Transfusion, 48(6), 1151–1155. https://doi.org/10.1111/j.1537-2995.2008.01660.x
  7. Seltsam, A., Grueger, D., Blasczyk, R., & Flegel, W. A. (2009). Easy identification of antibodies to high‐prevalence Scianna antigens and detection of admixed alloantibodies using soluble recombinant Scianna protein. Transfusion, 49(10), 2090–2096. https://doi.org/10.1111/j.1537-2995.2009.02255.x
  8. Seltsam, A., Strigens, S., Levene, C., Yahalom, V., Moulds, M., Moulds, J. J., Hustinx, H., Weisbach, V., Figueroa, D., Bade‐Doeding, C., DeLuca, D. S., & Blasczyk, R. (2006). The molecular diversity of Sema7A, the semaphorin that carries the JMH blood group antigens. Transfusion, 47(1), 133–146. https://doi.org/10.1111/j.1537-2995.2007.01076.x
  9. HARPAZ, N., FLOWERS, H. M., & SHARON, N. (1977). α‐D‐Galactosidase from Soybeans Destroying Blood‐Group B Antigens. European Journal of Biochemistry, 77(2), 419–426. https://doi.org/10.1111/j.1432-1033.1977.tb11682.x
  10. Shimin, Z., Jianxin, L., Yaomei, W., & Zhiming, Y. (1989). A simplified method for the preparation of wga‐sepharose 4B and its use in the purification of MN blood group antigens. Biomedical Chromatography, 3(1), 10–13. https://doi.org/10.1002/bmc.1130030104
  11. Zuckerman, S. H., Uretsky, S. C., & Douglas, S. D. (1974). Partial Purification of ABO Blood Group Antigens: Sodium Deoxycholate Fractionation of Human Erythrocyte Membranes. Vox Sanguinis, 27(6), 504–514. https://doi.org/10.1111/j.1423-0410.1974.tb02448.x
  12. Champagne, J., Delattre, C., Shanthi, C., Satheesh, B., Duverneuil, L., & Vijayalakshmi, M. A. (2007). Pseudoaffinity Chromatography Using a Convective Interaction Media®-Disk Monolithic Column. Chromatographia, 65(11-12), 639–648. https://doi.org/10.1365/s10337-007-0225-7
  13. Dinh, N. P., Cam, Q. M., Nguyen, A. M., Shchukarev, A., & Irgum, K. (2009). Functionalization of epoxy‐based monoliths for ion exchange chromatography of proteins. Journal of Separation Science, 32(15-16), 2556–2564. https://doi.org/10.1002/jssc.200900243
  14. Mihelič, I., Nemec, D., Podgornik, A., & Koloini, T. (2005). Pressure drop in CIM disk monolithic columns. Journal of Chromatography A, 1065(1), 59–67. https://doi.org/10.1016/j.chroma.2004.10.054
  15. Amatschek, K., Necina, R., Hahn, R., Schallaun, E., Schwinn, H., Josić, D., & Jungbauer, A. (2000). Affinity Chromatography of Human Blood Coagulation Factor VIII on Monoliths with Peptides from a Combinatorial Library. Journal of High Resolution Chromatography, 23(1), 47–58. https://doi.org/10.1002/(sici)1521-4168(20000101)23:1%3C47::aid-jhrc47%3E3.0.co;2-p
  16. Giese, R. W. (2008). Editorial on “Polymethacrylate monoliths for preparative and industrial separation of biomolecular assemblies” by A. Jungbauer and R. Hahn. Journal of Chromatography A, 1184(1-2), 61. https://doi.org/10.1016/j.chroma.2007.12.057
  17. Hahn, R., Panzer, M., Hansen, E., Mollerup, J., & Jungbauer, A. (2002). Mass transfer properties of monoliths. Separation Science and Technology, 37(7), 1545–1565. https://doi.org/10.1081/ss-120002736
  18. Josic, D., Buchacher, A., & Jungbauer, A. (2001). Monoliths as stationary phases for separation of proteins and polynucleotides and enzymatic conversion. Journal of Chromatography B: Biomedical Sciences and Applications, 752(2), 191–205. https://doi.org/10.1016/s0378-4347(00)00499-0
  19. Jungbauer, A., & Hahn, R. (2004). Monoliths for fast bioseparation and bioconversion and their applications in biotechnology. Journal of Separation Science, 27(10-11), 767–778. https://doi.org/10.1002/jssc.200401812
  20. Tennikova, T. B., & Freitag, R. (2000). An Introduction to Monolithic Disks as Stationary Phases for High Performance Biochromatography. Journal of High Resolution Chromatography, 23(1), 27–38. https://doi.org/10.1002/(sici)1521-4168(20000101)23:1%3C27::aid-jhrc27%3E3.0.co;2-t
  21. Tennikova, T. B., & Svec, F. (1993). High-performance membrane chromatography: Highly efficient separation method for proteins in ion-exchange, hydrophobic interaction and reversed-phase modes. Journal of Chromatography A, 646(2), 279–288. https://doi.org/10.1016/0021-9673(93)83340-x
  22. Tetala, K. K. R., & van Beek, T. A. (2010). Bioaffinity chromatography on monolithic supports. Journal of Separation Science, 33(3), 422–438. https://doi.org/10.1002/jssc.200900635
  23. Rucevic, M., Clifton, J. G., Huang, F., Li, X., Callanan, H., Hixson, D. C., & Josic, D. (2006). Use of short monolithic columns for isolation of low abundance membrane proteins. Journal of Chromatography A, 1123(2), 199–204. https://doi.org/10.1016/j.chroma.2006.02.053
  24. Štrancar, A., Koselj, P., Schwinn, H., & Josic, D. (1996). Application of Compact Porous Disks for Fast Separations of Biopolymers and In-Process Control in Biotechnology. Analytical Chemistry, 68(19), 3483–3488. https://doi.org/10.1021/ac960292f
  25. Tennikov, M. B., Gazdina, N. V., Tennikova, T. B., & Svec, F. (1998). Effect of porous structure of macroporous polymer supports on resolution in high-performance membrane chromatography of proteins. Journal of Chromatography A, 798(1-2), 55–64. https://doi.org/10.1016/s0021-9673(97)00873-x

1–25 of 58

Citations

  1. Poddar, S., Sharmeen, S., & Hage, D. S. (2021). Affinity monolith chromatography: A review of general principles and recent developments. ELECTROPHORESIS, 42(24), 2577–2598. https://doi.org/10.1002/elps.202100163
  2. González-González, M., Mayolo-Deloisa, K., & Rito-Palomares, M. (2020). Recent advances in antibody-based monolith chromatography for therapeutic applications. In Approaches to the Purification, Analysis and Characterization of Antibody-Based Therapeutics (pp. 105–116). Elsevier. https://doi.org/10.1016/b978-0-08-103019-6.00005-9
  3. Liangsupree, T., Multia, E., Metso, J., Jauhiainen, M., Forssén, P., Fornstedt, T., Öörni, K., Podgornik, A., & Riekkola, M.-L. (2019). Rapid affinity chromatographic isolation method for LDL in human plasma by immobilized chondroitin-6-sulfate and anti-apoB-100 antibody monolithic disks in tandem. Scientific Reports, 9(1). https://doi.org/10.1038/s41598-019-47750-z
  4. Li, Z., Rodriguez, E., Azaria, S., Pekarek, A., & Hage, D. S. (2017). Affinity monolith chromatography: A review of general principles and applications. ELECTROPHORESIS, 38(22-23), 2837–2850. https://doi.org/10.1002/elps.201700101
  5. Chen, J., Peng, R., & Chen, X. (2017). Hydrophobic interaction membrane chromatography for bioseparation and responsive polymer ligands involved. Frontiers of Materials Science, 11(3), 197–214. https://doi.org/10.1007/s11706-017-0390-z
  6. Miao, C., Bai, R., Xu, S., Hong, T., & Ji, Y. (2017). Carboxylated single-walled carbon nanotube-functionalized chiral polymer monoliths for affinity capillary electrochromatography. Journal of Chromatography A, 1487, 227–234. https://doi.org/10.1016/j.chroma.2017.01.025
  7. https://doi.org/10.15625/1859-3097/17/1/9718
  8. https://doi.org/10.3390/chromatography2020195
  9. https://doi.org/10.4155/fseb2013.14.13
  10. Mitulović, G. (2014). New HPLC Techniques for Proteomics Analysis: A Short Overview of Latest Developments. Journal of Liquid Chromatography & Related Technologies, 38(3), 390–403. https://doi.org/10.1080/10826076.2014.941266
  11. Charcosset, C. (2012). Membrane chromatography. In Membrane Processes in Biotechnology and Pharmaceutics (pp. 169–212). Elsevier. https://doi.org/10.1016/b978-0-444-56334-7.00005-8
  12. Huang, X., & Yuan, D. (2012). Recent Developments of Extraction and Micro-extraction Technologies with Porous Monoliths. Critical Reviews in Analytical Chemistry, 42(1), 38–49. https://doi.org/10.1080/10408347.2012.629950
  13. Gunasena, D. N., & El Rassi, Z. (2011). Organic monoliths for hydrophilic interaction electrochromatography/chromatography and immunoaffinity chromatography. ELECTROPHORESIS, 33(1), 251–261. https://doi.org/10.1002/elps.201100523
  14. Arrua, R. D., & Alvarez Igarzabal, C. I. (2011). Macroporous monolithic supports for affinity chromatography. Journal of Separation Science, 34(16-17), 1974–1987. https://doi.org/10.1002/jssc.201100197
  15. Sproß, J., & Sinz, A. (2011). Monolithic media for applications in affinity chromatography. Journal of Separation Science, 34(16-17), 1958–1973. https://doi.org/10.1002/jssc.201100400
  16. Sushma, K., Vijayalakshmi, M. A., Krishnan, V., & Satheeshkumar, P. K. (2011). Cloning, expression, purification and characterization of a single chain variable fragment specific to tumor necrosis factor alpha in Escherichia coli. Journal of Biotechnology, 156(4), 238–244. https://doi.org/10.1016/j.jbiotec.2011.06.039