Published July 7, 2022 | Journal article | Version v1 | https://doi.org/10.1038/s41598-022-15712-7

Comparison study of reconstruction algorithms for volumetric necrosis maps from 2D multi-slice GRE thermometry images

Description

AbstractCancer is a disease which requires a significant amount of careful medical attention. For minimally-invasive thermal ablation procedures, the monitoring of heat distribution is one of the biggest challenges. In this work, three approaches for volumetric heat map reconstruction (Delauney triangulation, minimum volume enclosing ellipsoids (MVEE) and splines) are presented based on uniformly distributed 2D MRI phase images rotated around the applicator's main axis. We compare them with our previous temperature interpolation method with respect to accuracy, robustness and adaptability. All approaches are evaluated during MWA treatment on the same data sets consisting of 13 ex vivo bio protein phantoms, including six phantoms with simulated heat sink effects. Regarding accuracy, the DSC similarity results show a strong trend towards the MVEE ($$0.80\pm 0.03$$ 0.80 ± 0.03 ) and the splines ($$0.77\pm 0.04$$ 0.77 ± 0.04 ) method compared to the Delauney triangulation ($$0.75\pm 0.02$$ 0.75 ± 0.02 ) or the temperature interpolation ($$0.73\pm 0.07$$ 0.73 ± 0.07 ). Robustness is increased for all three approaches and the adaptability shows a significant trend towards the initial interpolation method and the splines. To overcome local inhomogeneities in the acquired data, the use of adaptive simulations should be considered in the future. In addition, the transfer to in vivo animal experiments should be considered to test for clinical applicability.

Files

s41598-022-15712-7.pdf

Files (1.8 MB)

Name Size Download all
md5:312c8e61e017f80829b3a99213916120
1.8 MB Preview Download

Additional details

Dates

Issued
July 7, 2022

References

  1. Bray, F., Ferlay, J., Soerjomataram, I., Siegel, R. L., Torre, L. A., & Jemal, A. (2018). Global cancer statistics 2018: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries. CA: A Cancer Journal for Clinicians, 68(6), 394–424. https://doi.org/10.3322/caac.21492
  2. Sung, H., Ferlay, J., Siegel, R. L., Laversanne, M., Soerjomataram, I., Jemal, A., & Bray, F. (2021). Global Cancer Statistics 2020: GLOBOCAN Estimates of Incidence and Mortality Worldwide for 36 Cancers in 185 Countries. CA: A Cancer Journal for Clinicians, 71(3), 209–249. https://doi.org/10.3322/caac.21660
  3. Ruiter, S. J. S., Heerink, W. J., & de Jong, K. P. (2018). Liver microwave ablation: a systematic review of various FDA-approved systems. European Radiology, 29(8), 4026–4035. https://doi.org/10.1007/s00330-018-5842-z
  4. Yang, G., Xiong, Y., Sun, J., Wang, G., Li, W., Tang, T., & Li, J. (2020). The efficacy of microwave ablation versus liver resection in the treatment of hepatocellular carcinoma and liver metastases: A systematic review and meta-analysis. International Journal of Surgery, 77, 85–93. https://doi.org/10.1016/j.ijsu.2020.03.006
  5. Laimer, G., Schullian, P., Jaschke, N., Putzer, D., Eberle, G., Alzaga, A., Odisio, B., & Bale, R. (2020). Minimal ablative margin (MAM) assessment with image fusion: an independent predictor for local tumor progression in hepatocellular carcinoma after stereotactic radiofrequency ablation. European Radiology, 30(5), 2463–2472. https://doi.org/10.1007/s00330-019-06609-7
  6. Zhu, M., Sun, Z., & Ng, C. K. (2017). Image-guided thermal ablation with MR-based thermometry. Quantitative Imaging in Medicine and Surgery, 7(3), 356–368. https://doi.org/10.21037/qims.2017.06.06
  7. Kägebein, U., Speck, O., Wacker, F., & Hensen, B. (2018). Motion Correction in Proton Resonance Frequency–based Thermometry in the Liver. Topics in Magnetic Resonance Imaging, 27(1), 53–61. https://doi.org/10.1097/rmr.0000000000000157
  8. Alpers, J., Reimert, D. L., Rötzer, M., Gerlach, T., Gutberlet, M., Wacker, F., Hensen, B., & Hansen, C. (2021). 2.5D Thermometry Maps for MRI-Guided Tumor Ablation. In Lecture Notes in Computer Science (pp. 311–320). Springer International Publishing. https://doi.org/10.1007/978-3-030-87202-1_30
  9. Köhler, M. O., Mougenot, C., Quesson, B., Enholm, J., Le Bail, B., Laurent, C., Moonen, C. T. W., & Ehnholm, G. J. (2009). Volumetric HIFU ablation under 3D guidance of rapid MRI thermometry. Medical Physics, 36(8), 3521–3535. https://doi.org/10.1118/1.3152112
  10. Todd, N., Prakash, J., Odéen, H., de Bever, J., Payne, A., Yalavarthy, P., & Parker, D. L. (2013). Toward real‐time availability of 3D temperature maps created with temporally constrained reconstruction. Magnetic Resonance in Medicine, 71(4), 1394–1404. https://doi.org/10.1002/mrm.24783
  11. Odéen, H., Almquist, S., de Bever, J., Christensen, D. A., & Parker, D. L. (2016). MR thermometry for focused ultrasound monitoring utilizing model predictive filtering and ultrasound beam modeling. Journal of Therapeutic Ultrasound, 4(1). https://doi.org/10.1186/s40349-016-0067-6
  12. Marx, M., Ghanouni, P., & Butts Pauly, K. (2016). Specialized volumetric thermometry for improved guidance of MRgFUS in brain: MR Thermometry for Guidance of MRgFUS in Brain. Magnetic Resonance in Medicine, 78(2), 508–517. https://doi.org/10.1002/mrm.26385
  13. Svedin, B. T., Payne, A., Bolster, B. D., & Parker, D. L. (2017). Multiecho pseudo‐golden angle stack of stars thermometry with high spatial and temporal resolution using k‐space weighted image contrast. Magnetic Resonance in Medicine, 79(3), 1407–1419. https://doi.org/10.1002/mrm.26797
  14. Fielden, S. W., Feng, X., Zhao, L., Miller, G. W., Geeslin, M., Dallapiazza, R. F., Elias, W. J., Wintermark, M., Butts Pauly, K., & Meyer, C. H. (2017). A spiral‐based volumetric acquisition for MR temperature imaging. Magnetic Resonance in Medicine, 79(6), 3122–3127. https://doi.org/10.1002/mrm.26981
  15. Zhang, L., Armstrong, T., Li, X., & Wu, H. H. (2019). A variable flip angle golden‐angle‐ordered 3D stack‐of‐radial MRI technique for simultaneous proton resonant frequency shift and T1‐based thermometry. Magnetic Resonance in Medicine, 82(6), 2062–2076. https://doi.org/10.1002/mrm.27883
  16. Chen, Q., Li, Y., Jiang, R., Zou, C., Tie, C., Wen, J., Yang, X., Zhang, X., Liu, X., & Zheng, H. (2020). A flexible 9-channel coil array for fast 3D MR thermometry in MR-guided high-intensity focused ultrasound (HIFU) studies on rabbits at 3 T. Magnetic Resonance Imaging, 65, 37–44. https://doi.org/10.1016/j.mri.2019.10.008
  17. Quah, K., Poorman, M. E., Allen, S. P., & Grissom, W. A. (2019). Simultaneous multislice MRI thermometry with a single coil using incoherent blipped‐controlled aliasing. Magnetic Resonance in Medicine, 83(2), 479–491. https://doi.org/10.1002/mrm.27940
  18. Jiang, R., Jia, S., Qiao, Y., Chen, Q., Wen, J., Liang, D., Liu, X., Zheng, H., & Zou, C. (2020). Real-time volumetric MR thermometry using 3D echo-shifted sequence under an open source reconstruction platform. Magnetic Resonance Imaging, 70, 22–28. https://doi.org/10.1016/j.mri.2020.04.001
  19. Campwala, Z., Szewczyk, B., Maietta, T., Trowbridge, R., Tarasek, M., Bhushan, C., Fiveland, E., Ghoshal, G., Heffter, T., Gandomi, K., Carvalho, P. A., Nycz, C., Jeannotte, E., Staudt, M., Nalwalk, J., Hellman, A., Zhao, Z., Burdette, E. C., Fischer, G., … Pilitsis, J. G. (2021). Predicting ablation zones with multislice volumetric 2-D magnetic resonance thermal imaging. International Journal of Hyperthermia, 38(1), 907–915. https://doi.org/10.1080/02656736.2021.1936215
  20. de Landro, M., Korganbayev, S., Ambarki, K., Verde, J., Odeen, H., Giraudeau, C., & Saccomandi, P. (2021). Magnetic resonance-based measurement system: comparison of 2D and 3D echo-planar imaging sequences for thermometry application. 2021 IEEE International Instrumentation and Measurement Technology Conference (I2MTC), 1–6. https://doi.org/10.1109/i2mtc50364.2021.9460088
  21. Gorny, K. R., Favazza, C. P., Lu, A., Felmlee, J. P., Hangiandreou, N. J., Browne, J. E., Stenzel, W. S., Muggli, J. L., Anderson, A. G., Thompson, S. M., & Woodrum, D. A. (2019). Practical implementation of robust MR-thermometry during clinical MR-guided microwave ablations in the liver at 1.5 T. Physica Medica, 67, 91–99. https://doi.org/10.1016/j.ejmp.2019.10.020
  22. Bowyer, A. (1981). Computing Dirichlet tessellations. The Computer Journal, 24(2), 162–166. https://doi.org/10.1093/comjnl/24.2.162
  23. Watson, D. F. (1981). Computing the n-dimensional Delaunay tessellation with application to Voronoi polytopes. The Computer Journal, 24(2), 167–172. https://doi.org/10.1093/comjnl/24.2.167
  24. Marot, C., Pellerin, J., & Remacle, J. (2018). One machine, one minute, three billion tetrahedra. International Journal for Numerical Methods in Engineering, 117(9), 967–990. https://doi.org/10.1002/nme.5987
  25. Su, T., Wang, W., Liu, H., Liu, Z., Li, X., Jia, Z., Zhou, L., Song, Z., Ding, M., & Cui, A. (2020). An adaptive and rapid 3D Delaunay triangulation for randomly distributed point cloud data. The Visual Computer, 38(1), 197–221. https://doi.org/10.1007/s00371-020-02011-3

1–25 of 38