Reliability of a pulse oximeter in the detection of hyperoxemia
Additional details
Identifiers
- OpenAlex
- W1987117918
- PMID
- 8419620
- URL
- https://linkinghub.elsevier.com/retrieve/pii/S0022347605834948
Dates
- Issued
-
January 1993
References
- Physiology of oxygenation and its relation to pulse oximetry in neonates
- Flynn, J. T., Bancalari, E., Snyder, E. S., Goldberg, R. N., Feuer, W., Cassady, J., Schiffman, J., Feldman, H. I., Baghynski, B., Buckley, E., Roberts, J., & Gillings, D. (1992). A Cohort Study of Transcutaneous Oxygen Tension and the Incidence and Severity of Retinopathy of Prematurity. New England Journal of Medicine, 326(16), 1050–1054. https://doi.org/10.1056/nejm199204163261603
- Bucher, H.-U., Fanconi, S., Baeckert, P., & Duc, G. (1989). Hyperoxemia in Newborn Infants: Detection by Pulse Oximetry. Pediatrics, 84(2), 226–230. https://doi.org/10.1542/peds.84.2.226
- Southall, D. P., Bignall, S., Stebbens, V. A., Alexander, J. R., Rivers, R. P., & Lissauer, T. (1987). Pulse oximeter and transcutaneous arterial oxygen measurements in neonatal and paediatric intensive care. Archives of Disease in Childhood, 62(9), 882–888. https://doi.org/10.1136/adc.62.9.882
- Pulse oximetry versus transcutaneous oxygen monitoring in perinatology application
- Wasunna, A., & Whitelaw, A. G. (1987). Pulse oximetry in preterm infants. Archives of Disease in Childhood, 62(9), 957–958. https://doi.org/10.1136/adc.62.9.957
- Pulse oximetry
- SOUTHALL, D. (1992). Inappropriate sensor application in pulse oximetry. The Lancet, 340(8817), 481–482. https://doi.org/10.1016/0140-6736(92)91799-e
- Poets, C. F., Stebbens, V. A., Alexander, J. R., Arrowsmith, W. A., Salfield, S. A. W., & Southall, D. P. (1992). Arterial oxygen saturation in preterm infants at discharge from the hospital and six weeks later. The Journal of Pediatrics, 120(3), 447–454. https://doi.org/10.1016/s0022-3476(05)80919-9
- Halliday, H. L., Dumpit, F. M., & Brady, J. P. (1980). Effects of Inspired Oxygen on Echocardiographic Assessment of Pulmonary Vascular Resistance and Myocardial Contractility in Bronchopulmonary Dysplasia. Pediatrics, 65(3), 536–540. https://doi.org/10.1542/peds.65.3.536
- Tay-Uyboco, J. S., Kwiatkowski, K., Cates, D. B., Kavanagh, L., & Rigatto, H. (1989). Hypoxic airway constriction in infants of very low birth weight recovering from moderate to severe bronchopulmonary dysplasia. The Journal of Pediatrics, 115(3), 456–459. https://doi.org/10.1016/s0022-3476(89)80855-8
- Teague, W. G., Pian, M. S., Heldt, G. P., & Tooley, W. H. (1988). An Acute Reduction in the Fraction of Inspired Oxygen Increases Airway Constriction in Infants with Chronic Lung Disease. American Review of Respiratory Disease, 137(4), 861–865. https://doi.org/10.1164/ajrccm/137.4.861
Citations
- King, B., Dove, J., McGonigle, S. J., Ames, W. A., & Vesoulis, Z. A. (2025). Identifying performance differences between two pulse oximetry systems in simulated critical neonatal conditions. Journal of Perinatology, 45(11), 1608–1614. https://doi.org/10.1038/s41372-025-02364-4
- Vesoulis, Z., Tims, A., Lodhi, H., Lalos, N., & Whitehead, H. (2021). Racial discrepancy in pulse oximeter accuracy in preterm infants. Journal of Perinatology, 42(1), 79–85. https://doi.org/10.1038/s41372-021-01230-3
- https://doi.org/10.1097/mop.0000000000000993
- https://doi.org/10.1111/apa.15225
- Di Fiore, J. M., MacFarlane, P. M., & Martin, R. J. (2019). Intermittent Hypoxemia in Preterm Infants. Clinics in Perinatology, 46(3), 553–565. https://doi.org/10.1016/j.clp.2019.05.006
- Poets, C. F. (2019). Noninvasive Monitoring and Assessment of Oxygenation in Infants. Clinics in Perinatology, 46(3), 417–433. https://doi.org/10.1016/j.clp.2019.05.010
- Bancalari, E., Claure, N., & Jain, D. (2018). Neonatal Respiratory Therapy. In Avery's Diseases of the Newborn (pp. 632–652.e6). Elsevier. https://doi.org/10.1016/b978-0-323-40139-5.00045-0
- https://doi.org/10.3389/fped.2015.00094
- Bancalari, E., & Claure, N. (2012). Principles of Respiratory Monitoring and Therapy. In Avery's Diseases of the Newborn (pp. 612–632). Elsevier. https://doi.org/10.1016/b978-1-4377-0134-0.10045-9
- Tin, W., Carlo, W. A., & Gupta, S. (2012). Oxygenation Targeting and Outcomes in Preterm Infants. In The Newborn Lung: Neonatology Questions and Controversies (pp. 301–327). Elsevier. https://doi.org/10.1016/b978-1-4377-2682-4.00015-9
- https://doi.org/10.3345/kjp.2011.54.9.359
- Ellsbury, D. L., & Ursprung, R. (2010). Comprehensive Oxygen Management for the Prevention of Retinopathy of Prematurity: The Pediatrix Experience. Clinics in Perinatology, 37(1), 203–215. https://doi.org/10.1016/j.clp.2010.01.012
- Tin, W., & Gupta, S. (2008). Optimal Levels of Oxygenation in Preterm Infants: Impact on Short- and Long-Term Outcomes. In The Newborn Lung (pp. 333–360). Elsevier. https://doi.org/10.1016/b978-141603166-6.10015-4
- Tan, S., & Campbell, M. (2008). Acid–base physiology and blood gas interpretation in the neonate. Paediatrics and Child Health, 18(4), 172–177. https://doi.org/10.1016/j.paed.2007.12.013
- https://doi.org/10.1542/peds.2007-0117
- https://doi.org/10.4037/ajcc2007.16.2.168
- Obladen, M. (n.d.). Blutgasanalyse und Sauerstofftherapie. In Neugeborenen-intensivmedizin (pp. 97–121). Springer Berlin Heidelberg. https://doi.org/10.1007/978-3-540-33738-6_6
- Shiao, S.-Y. P. K., Ou, C.-N., & Pierantoni, H. (2006). The measurement of accurate fetal hemoglobin and related oxygen saturation by the hemoximeter. Clinica Chimica Acta, 374(1-2), 75–80. https://doi.org/10.1016/j.cca.2006.05.042
- Hansen, T. N., Corbet, A., Gest, A. L., & Moise, A. A. (2005). Principles of Respiratory Monitoring and Therapy. In Avery's Diseases of the Newborn (pp. 648–669). Elsevier. https://doi.org/10.1016/b978-072169347-7.50047-0
- Shiao, S.-Y. P. K. (2005). Accurate Measurements of Oxygen Saturation in Neonates: Paired Arterial and Venous Blood Analyses. Newborn and Infant Nursing Reviews, 5(4), 170–178. https://doi.org/10.1053/j.nainr.2005.09.001
- https://doi.org/10.1097/00005237-200510000-00010
- Reich, J. D., Miller, S., Brogdon, B., Casatelli, J., Gompf, T. C., Huhta, J. C., & Sullivan, K. (2003). The use of pulse oximetry to detect congenital heart disease. The Journal of Pediatrics, 142(3), 268–272. https://doi.org/10.1067/mpd.2003.87
- https://doi.org/10.1542/neo.4.12.e340
- Obladen, M. (2002). Blutgasanalyse und Sauerstofftherapie. In Neugeborenenintensivpflege (pp. 93–117). Springer Berlin Heidelberg. https://doi.org/10.1007/978-3-662-08937-8_6
- https://doi.org/10.1136/fn.87.3.f217
1–25 of 39