Immunodiagnostics and immunosensor design (IUPAC Technical Report)
Description
Abstract This work compiles information on the principles of diagnostic immunochemical methods and the recent advances in this field. It presents an overview of modern techniques for the production of diagnostic antibodies, their modification with the aim of improving their diagnostic potency, the different types of immunochemical detection systems, and the increasing diagnostic applications for human health that include specific disease markers, individualized diagnosis of cancer subtypes, therapeutic and addictive drugs, food residues, and environmental contaminants. A special focus lies in novel developments of immunosensor techniques, promising approaches to miniaturized detection units and the associated microfluidic systems. The trends towards high-throughput systems, multiplexed analysis, and miniaturization of the diagnostic tools are discussed. It is also made evident that progress in the last few years has largely relied on novel chemical approaches.
Additional details
Identifiers
Dates
- Issued
-
October 21, 2014
References
- Salavatifar, M., Amin, S., Jahromi, Z. M., Rasgoo, N., Rastgoo, N., & Arbabi, M. (2011). Green Fluorescent-Conjugated Anti-CEA Single Chain Antibody for the Detection of CEA-Positive Cancer Cells. Hybridoma, 30(3), 229–238. https://doi.org/10.1089/hyb.2011.0009
- Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2011). Point of Care Diagnostics: Status and Future. Analytical Chemistry, 84(2), 487–515. https://doi.org/10.1021/ac2030199
- Saunders, N. A. (2011). Application of Nanomaterials to Arrays for Infectious Disease Diagnosis. Nanomedicine, 6(2), 271–280. https://doi.org/10.2217/nnm.10.161
- Ihara, M., Suzuki, T., Kobayashi, N., Goto, J., & Ueda, H. (2009). Open-Sandwich Enzyme Immunoassay for One-Step Noncompetitive Detection of Corticosteroid 11-Deoxycortisol. Analytical Chemistry, 81(20), 8298–8304. https://doi.org/10.1021/ac900700a
- Einsporn, S., & Koehler, A. (2008). Electron-microscopic localization of lipophilic chemicals by an antibody-based detection system using the blue mussel Mytilus edulis as a model system. Environmental Toxicology and Chemistry, 27(3), 554–560. https://doi.org/10.1897/07-348.1
- McDonagh, C., Stranik, O., Nooney, R., & MacCraith, B. D. (2009). Nanoparticle Strategies for Enhancing The Sensitivity of Fluorescence-Based Biochips. Nanomedicine, 4(6), 645–656. https://doi.org/10.2217/nnm.09.48
- Jonkheijm, P., Weinrich, D., Schröder, H., Niemeyer, C. M., & Waldmann, H. (2008). Chemical Strategies for Generating Protein Biochips. Angewandte Chemie International Edition, 47(50), 9618–9647. https://doi.org/10.1002/anie.200801711
- Hasui, K., & Murata, F. (2005). A new simplified catalyzed signal amplification system for minimizing non-specific staining in tissues with supersensitive immunohistochemistry. Archives of Histology and Cytology, 68(1), 1–17. https://doi.org/10.1679/aohc.68.1
- Bange, A., Halsall, H. B., & Heineman, W. R. (2005). Microfluidic immunosensor systems. Biosensors and Bioelectronics, 20(12), 2488–2503. https://doi.org/10.1016/j.bios.2004.10.016
- Protocols in Biology
- Current Protocols in Chap Unit
- Burger, R., & Ducrée, J. (2012). Handling and analysis of cells and bioparticles on centrifugal microfluidic platforms. Expert Review of Molecular Diagnostics, 12(4), 407–421. https://doi.org/10.1586/erm.12.28
- Binder, S. (2006). Autoantibody Detection Using Multiplex Technologies. Lupus, 15(7), 412–421. https://doi.org/10.1191/0961203306lu2326oa
- Hu, M., Yan, J., He, Y., Lu, H., Weng, L., Song, S., Fan, C., & Wang, L. (2009). Ultrasensitive, Multiplexed Detection of Cancer Biomarkers Directly in Serum by Using a Quantum Dot-Based Microfluidic Protein Chip. ACS Nano, 4(1), 488–494. https://doi.org/10.1021/nn901404h
- Jia, C.-P., Zhong, X.-Q., Hua, B., Liu, M.-Y., Jing, F.-X., Lou, X.-H., Yao, S.-H., Xiang, J.-Q., Jin, Q.-H., & Zhao, J.-L. (2009). Nano-ELISA for highly sensitive protein detection. Biosensors and Bioelectronics, 24(9), 2836–2841. https://doi.org/10.1016/j.bios.2009.02.024
- Ren, S., Wang, X., Lin, Z., Li,, Z., Ying,, X., Chen, G., & Lin, J. (2008). Development of a high‐throughput, indirect antibody immobilization format chemiluminescence enzyme immunoassay (CLEIA) for the determination of progesterone in human serum. Luminescence, 23(3), 175–181. https://doi.org/10.1002/bio.1031
- High Throughput
- Expert
- Pure
- Mohammed, M.-I., & Desmulliez, M. P. Y. (2011). Lab-on-a-chip based immunosensor principles and technologies for the detection of cardiac biomarkers: a review. Lab Chip, 11(4), 569–595. https://doi.org/10.1039/c0lc00204f
- Rogers, S. C., Pruitt, C. W., Crouch, D. J., & Caravati, E. M. (2010). Rapid Urine Drug Screens. Pediatric Emergency Care, 26(9), 665–666. https://doi.org/10.1097/pec.0b013e3181f05443
- Expert
- Expert
- de la Rica
- von
1–25 of 212
Citations
- Yang, J., Zhang, J., Li, X., Xu, X., Wang, Y., Chen, X., Qi, S., Yan, F., Li, Y., Hong, X., & Chen, Y. (2025). Ultrafast Detection of Small Molecules Using a U-Shaped Transmission Terminal and Straight Plasmonic Sensing Region Fiber Probe Biokinetic Platform: A Case Study of Label-Free Hcy Detection via Indirect Competitive Immunoassay. Analytical Chemistry, 97(41), 22662–22671. https://doi.org/10.1021/acs.analchem.5c03937
- Amiri, M., Arshi, S., & Saberi, R. S. (2022). Recent advances in immunosensors for healthcare. In The Detection of Biomarkers (pp. 335–368). Elsevier. https://doi.org/10.1016/b978-0-12-822859-3.00014-6
- Velappan, N., Nguyen, H. B., Micheva-Viteva, S., Bedinger, D., Ye, C., Mangadu, B., Watts, A. J., Meagher, R., Bradfute, S., Hu, B., Waldo, G. S., & Lillo, A. M. (2022). Healthy humans can be a source of antibodies countering COVID-19. Bioengineered, 13(5), 12598–12624. https://doi.org/10.1080/21655979.2022.2076390
- Campos-Ferreira, D., Visani, V., Córdula, C., Nascimento, G. A., Montenegro, L. M. L., Schindler, H. C., & Cavalcanti, I. M. F. (2021). COVID-19 challenges: From SARS-CoV-2 infection to effective point-of-care diagnosis by electrochemical biosensing platforms. Biochemical Engineering Journal, 176, 108200. https://doi.org/10.1016/j.bej.2021.108200
- Lillo, A. M., Velappan, N., Kelliher, J. M., Watts, A. J., Merriman, S. P., Vuyisich, G., Lilley, L. M., Coombs, K. E., Mastren, T., Teshima, M., Stein, B. W., Wagner, G. L., Iyer, S., Bradbury, A. R., Harris, J. F., Dichosa, A. E., & Kozimor, S. A. (2020). <p>Development of Anti-<em>Yersinia pestis</em> Human Antibodies with Features Required for Diagnostic and Therapeutic Applications</p>. ImmunoTargets and Therapy, Volume 9, 299–316. https://doi.org/10.2147/itt.s267077
- Cohen, L., & Walt, D. R. (2018). Highly Sensitive and Multiplexed Protein Measurements. Chemical Reviews, 119(1), 293–321. https://doi.org/10.1021/acs.chemrev.8b00257
- Batistela, D. M., Stevani, C. V., & Freire, R. S. (2017). Immunoassay for Human IgG Using Antibody-functionalized Silver Nanoparticles. Analytical Sciences, 33(10), 1111–1114. https://doi.org/10.2116/analsci.33.1111
- Yáñez-Sedeño, P., Campuzano, S., & Pingarrón, J. (2017). Multiplexed Electrochemical Immunosensors for Clinical Biomarkers. Sensors, 17(5), 965. https://doi.org/10.3390/s17050965
- Duffy, G. F., & Moore, E. J. (2016). Electrochemical Immunosensors for Food Analysis: A Review of Recent Developments. Analytical Letters, 50(1), 1–32. https://doi.org/10.1080/00032719.2016.1167900