Published April 2024 | Journal article | Version v1 | https://doi.org/10.1016/j.memsci.2024.122575

Influence of utilizing hemodialysis membranes outside-in on solute clearance and filtration efficiency – One step towards a novel combined lung and kidney support device

Additional details

Dates

Issued
April 2024

References

  1. Chen, H., Yu, R.-G., Yin, N.-N., & Zhou, J.-X. (2014). Combination of extracorporeal membrane oxygenation and continuous renal replacement therapy in critically ill patients: a systematic review. Critical Care, 18(6). https://doi.org/10.1186/s13054-014-0675-x
  2. Sorino, C., Scichilone, N., Pedone, C., Negri, S., Visca, D., & Spanevello, A. (2018). When kidneys and lungs suffer together. Journal of Nephrology, 32(5), 699–707. https://doi.org/10.1007/s40620-018-00563-1
  3. Seczyńska, B., Królikowski, W., Nowak, I., Jankowski, M., Szułdrzyński, K., & Szczeklik, W. (2014). Continuous Renal Replacement Therapy During Extracorporeal Membrane Oxygenation in Patients Treated in Medical Intensive Care Unit: Technical Considerations. Therapeutic Apheresis and Dialysis, 18(6), 523–534. https://doi.org/10.1111/1744-9987.12188
  4. Continuous renal replacement therapy during extracorporeal membrane oxygenation: why, when and how?
  5. A retrospective analysis of the hemolysis occurrence during extracorporeal membrane oxygenation in a single center
  6. de Tymowski, C., Augustin, P., Houissa, H., Allou, N., Montravers, P., Delzongle, A., Pellenc, Q., & Desmard, M. (2017). CRRT Connected to ECMO: Managing High Pressures. ASAIO Journal, 63(1), 48–52. https://doi.org/10.1097/mat.0000000000000441
  7. Martins Costa, A., Halfwerk, F., Wiegmann, B., Neidlin, M., & Arens, J. (2022). Trends, Advantages and Disadvantages in Combined Extracorporeal Lung and Kidney Support From a Technical Point of View. Frontiers in Medical Technology, 4. https://doi.org/10.3389/fmedt.2022.909990
  8. Setty, A. A., Chiang, T. Y., Santos, J. A., Isenberg, B. C., Vedula, E. M., Keating, R. A., Sutherland, D. W., & Borenstein, J. T. (2023). Toward microfluidic integration of respiratory and renal organ support in a single cartridge. Artificial Organs, 47(9), 1442–1451. https://doi.org/10.1111/aor.14603
  9. Martins Costa, A., Halfwerk, F. R., Thiel, J.-N., Wiegmann, B., Neidlin, M., & Arens, J. (2023). Effect of hollow fiber configuration and replacement on the gas exchange performance of artificial membrane lungs. Journal of Membrane Science, 680, Article 121742. https://doi.org/10.1016/j.memsci.2023.121742
  10. Catapano, G., Wodetzki, A., & Baurmeister, U. (1992). Blood Flow outside Regularly Spaced Hollow Fibers: The Future Concept of Membrane Devices?. The International Journal of Artificial Organs, 15(6), 327–330. https://doi.org/10.1177/039139889201500602
  11. Dialysis membranes for acute kidney injury
  12. Bartlett, R. H. (2020). Physiology of Extracorporeal Gas Exchange. Comprehensive Physiology, 10(3), 879–891. https://doi.org/10.1002/j.2040-4603.2020.tb00130.x
  13. Wiegmann, B., Maurer, A., Zhang, R., Zardo, P., Haverich, A., & Fischer, S. (2013). Combined Pulmonary and Renal Support in a Single Extracorporeal Device. ASAIO Journal, 59(4), 433–438. https://doi.org/10.1097/mat.0b013e318292e887
  14. ter Beek, O. E. M., van Gelder, M. K., Lokhorst, C., Hazenbrink, D. H. M., Lentferink, B. H., Gerritsen, K. G. F., & Stamatialis, D. (2021). In vitro study of dual layer mixed matrix hollow fiber membranes for outside-in filtration of human blood plasma. Acta Biomaterialia, 123, 244–253. https://doi.org/10.1016/j.actbio.2020.12.063
  15. See, E. J., & Bellomo, R. (2021). How I prescribe continuous renal replacement therapy. Critical Care, 25(1). https://doi.org/10.1186/s13054-020-03448-7
  16. Ronco, C., Bellomo, R., Homel, P., Brendolan, A., Dan, M., Piccinni, P., & La Greca, G. (2000). Effects of different doses in continuous veno-venous haemofiltration on outcomes of acute renal failure: a prospective randomised trial. The Lancet, 356(9223), 26–30. https://doi.org/10.1016/s0140-6736(00)02430-2
  17. Vásquez Jiménez, E., Anumudu, S. J., & Neyra, J. A. (2021). Dose of Continuous Renal Replacement Therapy in Critically Ill Patients: A Bona Fide Quality Indicator. Nephron, 145(2), 91–98. https://doi.org/10.1159/000512846
  18. Clark, W. R., Leblanc, M., Ricci, Z., & Ronco, C. (2017). Quantification and Dosing of Renal Replacement Therapy in Acute Kidney Injury: A Reappraisal. Blood Purification, 44(2), 140–155. https://doi.org/10.1159/000475457
  19. Neyra, J. A., & Tolwani, A. (2021). CRRT prescription and delivery of dose. Seminars in Dialysis, 34(6), 432–439. https://doi.org/10.1111/sdi.12974
  20. Neyra, J. A., Yessayan, L., Thompson Bastin, M. L., Wille, K. M., & Tolwani, A. J. (2021). How To Prescribe And Troubleshoot Continuous Renal Replacement Therapy: A Case-Based Review. Kidney360, 2(2), 371–384. https://doi.org/10.34067/kid.0004912020
  21. Operating parameters and performance criteria for hemodialyzers and other membrane-separation devices
  22. Verification of physicochemical structures of dialysis membrane using reversal dialysis technique
  23. Polaschegg, H. D. (1993). Automatic, Noninvasive Intradialytic Clearance Measurement. The International Journal of Artificial Organs, 16(4), 185–191. https://doi.org/10.1177/039139889301600404
  24. Petitclerc, T., Goux, N., Reynier, A. L., & Béné, B. (1993). A Model for Non-Invasive Estimation of in Vivo Dialyzer Performances and Patient's Conductivity during Hemodialysis. The International Journal of Artificial Organs, 16(8), 585–591. https://doi.org/10.1177/039139889301600804
  25. Mohajerani, F., Clark, W. R., Ronco, C., & Narsimhan, V. (2022). Mass Transport in High-Flux Hemodialysis. Clinical Journal of the American Society of Nephrology, 17(5), 749–756. https://doi.org/10.2215/cjn.09410721

1–25 of 49

Citations

  1. Tasior, M. M., Gronwald, O., Ter Beek, O., & Stamatialis, D. (2027). Development of new hollow fiber membrane using sulfonated poly(phenylene sulfone) polymer for long term hemodialysis. Journal of Membrane Science, 763, Article 126376. https://doi.org/10.1016/j.memsci.2026.126376
  2. Kharrouba, E., Moyon, Q., Cove, M. E., Arens, J., Martins Costa, A., Fraser, J. F., & Suen, J. Y. (2026). Comparison of the approaches to combine Renal Replacement Therapy with Extracorporeal Membrane Oxygenation – a Scoping Review. Annals of Intensive Care, 16, Article 100165. https://doi.org/10.1016/j.aicoj.2026.100165
  3. https://doi.org/10.1111/aor.70139
  4. Allaoui, B. E., Wu, X., Wu, T., & Pang, C. H. (2025). Advanced Functional Materials in Kidney Dialysis: Progress, Challenges, and Clinical Prospects. Advanced Healthcare Materials, 15(12), Article e03904. https://doi.org/10.1002/adhm.202503904
  5. Thiel, J.-N., Costa, A. M., Wiegmann, B., Arens, J., Steinseifer, U., & Neidlin, M. (2025). Quantifying the influence of combined lung and kidney support using a cardiovascular model and sensitivity analysis-informed parameter identification. Computers in Biology and Medicine, 186, Article 109668. https://doi.org/10.1016/j.compbiomed.2025.109668
  6. Filimon, A., Serbezeanu, D., Onofrei, M. D., Pelin, I. M., Dumbrava, O., Suflet, D. M., & Lupa, L. (2025). Development of the electrospun membranes based on quaternized polysulfones with performance and functionality in hemodialysis. Materials & Design, 254, 114068. https://doi.org/10.1016/j.matdes.2025.114068
  7. Lau, M. P. X. L., Ling, R. R., Ong, B. J. A., Cho, H. J., Jeong, I.-. seok ., Sahoo, T. K., Chua, H. R., Shekar, K., & Ramanathan, K. (2025). Kidney replacement therapy during extracorporeal membrane oxygenation: pathophysiology, technical considerations, and outcomes. Renal Failure, 47(1), Article 2486557. https://doi.org/10.1080/0886022x.2025.2486557
  8. https://doi.org/10.1097/mat.0000000000002443
  9. https://doi.org/10.1097/mat.0000000000002505
  10. https://doi.org/10.3390/membranes15010016