Influence of utilizing hemodialysis membranes outside-in on solute clearance and filtration efficiency – One step towards a novel combined lung and kidney support device
Additional details
Identifiers
Funding
-
Deutsche Forschungsgemeinschaft
- 447746988
-
Deutsche Forschungsgemeinschaft
- SPP2014
Dates
- Issued
-
April 2024
References
- Chen, H., Yu, R.-G., Yin, N.-N., & Zhou, J.-X. (2014). Combination of extracorporeal membrane oxygenation and continuous renal replacement therapy in critically ill patients: a systematic review. Critical Care, 18(6). https://doi.org/10.1186/s13054-014-0675-x
- Sorino, C., Scichilone, N., Pedone, C., Negri, S., Visca, D., & Spanevello, A. (2018). When kidneys and lungs suffer together. Journal of Nephrology, 32(5), 699–707. https://doi.org/10.1007/s40620-018-00563-1
- Seczyńska, B., Królikowski, W., Nowak, I., Jankowski, M., Szułdrzyński, K., & Szczeklik, W. (2014). Continuous Renal Replacement Therapy During Extracorporeal Membrane Oxygenation in Patients Treated in Medical Intensive Care Unit: Technical Considerations. Therapeutic Apheresis and Dialysis, 18(6), 523–534. https://doi.org/10.1111/1744-9987.12188
- Continuous renal replacement therapy during extracorporeal membrane oxygenation: why, when and how?
- A retrospective analysis of the hemolysis occurrence during extracorporeal membrane oxygenation in a single center
- de Tymowski, C., Augustin, P., Houissa, H., Allou, N., Montravers, P., Delzongle, A., Pellenc, Q., & Desmard, M. (2017). CRRT Connected to ECMO: Managing High Pressures. ASAIO Journal, 63(1), 48–52. https://doi.org/10.1097/mat.0000000000000441
- Martins Costa, A., Halfwerk, F., Wiegmann, B., Neidlin, M., & Arens, J. (2022). Trends, Advantages and Disadvantages in Combined Extracorporeal Lung and Kidney Support From a Technical Point of View. Frontiers in Medical Technology, 4. https://doi.org/10.3389/fmedt.2022.909990
- Setty, A. A., Chiang, T. Y., Santos, J. A., Isenberg, B. C., Vedula, E. M., Keating, R. A., Sutherland, D. W., & Borenstein, J. T. (2023). Toward microfluidic integration of respiratory and renal organ support in a single cartridge. Artificial Organs, 47(9), 1442–1451. https://doi.org/10.1111/aor.14603
- Martins Costa, A., Halfwerk, F. R., Thiel, J.-N., Wiegmann, B., Neidlin, M., & Arens, J. (2023). Effect of hollow fiber configuration and replacement on the gas exchange performance of artificial membrane lungs. Journal of Membrane Science, 680, Article 121742. https://doi.org/10.1016/j.memsci.2023.121742
- Catapano, G., Wodetzki, A., & Baurmeister, U. (1992). Blood Flow outside Regularly Spaced Hollow Fibers: The Future Concept of Membrane Devices?. The International Journal of Artificial Organs, 15(6), 327–330. https://doi.org/10.1177/039139889201500602
- Dialysis membranes for acute kidney injury
- Bartlett, R. H. (2020). Physiology of Extracorporeal Gas Exchange. Comprehensive Physiology, 10(3), 879–891. https://doi.org/10.1002/j.2040-4603.2020.tb00130.x
- Wiegmann, B., Maurer, A., Zhang, R., Zardo, P., Haverich, A., & Fischer, S. (2013). Combined Pulmonary and Renal Support in a Single Extracorporeal Device. ASAIO Journal, 59(4), 433–438. https://doi.org/10.1097/mat.0b013e318292e887
- ter Beek, O. E. M., van Gelder, M. K., Lokhorst, C., Hazenbrink, D. H. M., Lentferink, B. H., Gerritsen, K. G. F., & Stamatialis, D. (2021). In vitro study of dual layer mixed matrix hollow fiber membranes for outside-in filtration of human blood plasma. Acta Biomaterialia, 123, 244–253. https://doi.org/10.1016/j.actbio.2020.12.063
- See, E. J., & Bellomo, R. (2021). How I prescribe continuous renal replacement therapy. Critical Care, 25(1). https://doi.org/10.1186/s13054-020-03448-7
- Ronco, C., Bellomo, R., Homel, P., Brendolan, A., Dan, M., Piccinni, P., & La Greca, G. (2000). Effects of different doses in continuous veno-venous haemofiltration on outcomes of acute renal failure: a prospective randomised trial. The Lancet, 356(9223), 26–30. https://doi.org/10.1016/s0140-6736(00)02430-2
- Vásquez Jiménez, E., Anumudu, S. J., & Neyra, J. A. (2021). Dose of Continuous Renal Replacement Therapy in Critically Ill Patients: A Bona Fide Quality Indicator. Nephron, 145(2), 91–98. https://doi.org/10.1159/000512846
- Clark, W. R., Leblanc, M., Ricci, Z., & Ronco, C. (2017). Quantification and Dosing of Renal Replacement Therapy in Acute Kidney Injury: A Reappraisal. Blood Purification, 44(2), 140–155. https://doi.org/10.1159/000475457
- Neyra, J. A., & Tolwani, A. (2021). CRRT prescription and delivery of dose. Seminars in Dialysis, 34(6), 432–439. https://doi.org/10.1111/sdi.12974
- Neyra, J. A., Yessayan, L., Thompson Bastin, M. L., Wille, K. M., & Tolwani, A. J. (2021). How To Prescribe And Troubleshoot Continuous Renal Replacement Therapy: A Case-Based Review. Kidney360, 2(2), 371–384. https://doi.org/10.34067/kid.0004912020
- Operating parameters and performance criteria for hemodialyzers and other membrane-separation devices
- Verification of physicochemical structures of dialysis membrane using reversal dialysis technique
- Polaschegg, H. D. (1993). Automatic, Noninvasive Intradialytic Clearance Measurement. The International Journal of Artificial Organs, 16(4), 185–191. https://doi.org/10.1177/039139889301600404
- Petitclerc, T., Goux, N., Reynier, A. L., & Béné, B. (1993). A Model for Non-Invasive Estimation of in Vivo Dialyzer Performances and Patient's Conductivity during Hemodialysis. The International Journal of Artificial Organs, 16(8), 585–591. https://doi.org/10.1177/039139889301600804
- Mohajerani, F., Clark, W. R., Ronco, C., & Narsimhan, V. (2022). Mass Transport in High-Flux Hemodialysis. Clinical Journal of the American Society of Nephrology, 17(5), 749–756. https://doi.org/10.2215/cjn.09410721
1–25 of 49
Citations
- Tasior, M. M., Gronwald, O., Ter Beek, O., & Stamatialis, D. (2027). Development of new hollow fiber membrane using sulfonated poly(phenylene sulfone) polymer for long term hemodialysis. Journal of Membrane Science, 763, Article 126376. https://doi.org/10.1016/j.memsci.2026.126376
- Kharrouba, E., Moyon, Q., Cove, M. E., Arens, J., Martins Costa, A., Fraser, J. F., & Suen, J. Y. (2026). Comparison of the approaches to combine Renal Replacement Therapy with Extracorporeal Membrane Oxygenation – a Scoping Review. Annals of Intensive Care, 16, Article 100165. https://doi.org/10.1016/j.aicoj.2026.100165
- https://doi.org/10.1111/aor.70139
- Allaoui, B. E., Wu, X., Wu, T., & Pang, C. H. (2025). Advanced Functional Materials in Kidney Dialysis: Progress, Challenges, and Clinical Prospects. Advanced Healthcare Materials, 15(12), Article e03904. https://doi.org/10.1002/adhm.202503904
- Thiel, J.-N., Costa, A. M., Wiegmann, B., Arens, J., Steinseifer, U., & Neidlin, M. (2025). Quantifying the influence of combined lung and kidney support using a cardiovascular model and sensitivity analysis-informed parameter identification. Computers in Biology and Medicine, 186, Article 109668. https://doi.org/10.1016/j.compbiomed.2025.109668
- Filimon, A., Serbezeanu, D., Onofrei, M. D., Pelin, I. M., Dumbrava, O., Suflet, D. M., & Lupa, L. (2025). Development of the electrospun membranes based on quaternized polysulfones with performance and functionality in hemodialysis. Materials & Design, 254, 114068. https://doi.org/10.1016/j.matdes.2025.114068
- Lau, M. P. X. L., Ling, R. R., Ong, B. J. A., Cho, H. J., Jeong, I.-. seok ., Sahoo, T. K., Chua, H. R., Shekar, K., & Ramanathan, K. (2025). Kidney replacement therapy during extracorporeal membrane oxygenation: pathophysiology, technical considerations, and outcomes. Renal Failure, 47(1), Article 2486557. https://doi.org/10.1080/0886022x.2025.2486557
- https://doi.org/10.1097/mat.0000000000002443
- https://doi.org/10.1097/mat.0000000000002505
- https://doi.org/10.3390/membranes15010016