Published March 2013 | Other | Version v1 | https://doi.org/10.2217/ebo.12.510

Ear, nose and throat surgery

  • 1. Born in 1971, Omid Majdani started his medical education at the University of Erlangen-Nurnberg, Germany and finished at the Free University of Berlin, Germany (now: Charité University Medicine Berlin) in 1999. His residency followed at the Hannover Medical School (Germany). In 2004, he performed his board certification in otorhinolaryngology. Since then, he has been working at the ENT clinic of Hannover Medical School as a senior surgeon, initially as Head of the Rhinology and Anterior Skull Base team....
  • 2. ROR icon Medizinische Hochschule Hannover
  • 3. ROR icon Leibniz University Hannover

Additional details

Dates

Issued
March 2013

References

  1. Messerklinger W . Endoscopy of the Nose . Urban & Schwarzenberg, MD, USA (1978) .
  2. Draf, W. (1978). Therapeutic Endoscopy of the Paranasal Sinuses. Endoscopy, 10(04), 247–254. https://doi.org/10.1055/s-0028-1098303
  3. Strong, M. S., & Jako, G. J. (1972). Laser Surgery in the Larynx Early Clinical Experience with Continuous Co 2 Laser. Annals of Otology, Rhinology & Laryngology, 81(6), 791–798. https://doi.org/10.1177/000348947208100606
  4. Vaughan, C. W. (1978). Transoral Laryngeal Surgery Using the CO2 Laser: Laboratory Experiments and Clinical Experience. The Laryngoscope, 88(9), 1399–1420. https://doi.org/10.1002/lary.1978.88.9.1399
  5. Mösges, R., & Schlöndorff, G. (1988). A new imaging method for intraoperative therapy control in skull-base surgery. Neurosurgical Review, 11(3-4), 245–247. https://doi.org/10.1007/bf01741417
  6. Lahiri, U., Labadie, R. F., Changchun Liu, Balachandran, R., Majdani, O., & Sarkar, N. (2010). A Step Toward Identification of Surgical Actions in Mastoidectomy. IEEE Transactions on Biomedical Engineering, 57(2), 479–487. https://doi.org/10.1109/tbme.2009.2031982
  7. Federspil, P. A., Geisthoff, U. W., Henrich, D., & Plinkert, P. K. (2003). Development of the First Force‐Controlled Robot for Otoneurosurgery. The Laryngoscope, 113(3), 465–471. https://doi.org/10.1097/00005537-200303000-00014
  8. Adaptation of a Hexapod-Based Robotic System for Extended Endoscope-Assisted Transsphenoidal Skull Base Surgery. (2004). Adaptation of a Hexapod-Based Robotic System for Extended Endoscope-Assisted Transsphenoidal Skull Base Surgery. Min - Minimally Invasive Neurosurgery, 47(1), 41–46. https://doi.org/10.1055/s-2003-812465
  9. Strauss, G., Koulechov, K., Richter, R., Dietz, A., Trantakis, C., & Lüth, T. (2005). Navigated control in functional endoscopic sinus surgery. The International Journal of Medical Robotics and Computer Assisted Surgery, 1(3), 31–41. https://doi.org/10.1002/rcs.25
  10. Bumm, K., Wurm, J., Rachinger, J., Dannenmann, T., Bohr, C., Fahlbusch, R., Iro, H., & Nimsky, C. (2005). An Automated Robotic Approach with Redundant Navigation for Minimal Invasive Extended Transsphenoidal Skull Base Surgery. min - Minimally Invasive Neurosurgery, 48(3), 159–164. https://doi.org/10.1055/s-2005-870903
  11. Eichhorn, K. W. G., & Bootz, F. (2010). Clinical Requirements and Possible Applications of Robot Assisted Endoscopy in Skull Base and Sinus Surgery. In Acta Neurochirurgica Supplementum (pp. 237–240). Springer Vienna. https://doi.org/10.1007/978-3-211-99651-5_37
  12. Nathan, C.-A., Chakradeo, V., Malhotra, K., D'Agostino, H., & Patwardhan, R. (2006). The Voice-Controlled Robotic Assist Scope Holder AESOP for the Endoscopic Approach to the Sella. Skull Base, 16(03), 123–131. https://doi.org/10.1055/s-2006-939679
  13. O'Malley, B. W., Weinstein, G. S., Snyder, W., & Hockstein, N. G. (2006). Transoral Robotic Surgery (TORS) for Base of Tongue Neoplasms. The Laryngoscope, 116(8), 1465–1472. https://doi.org/10.1097/01.mlg.0000227184.90514.1a
  14. Federspil, P. A., Geisthoff, U. W., Henrich, D., & Plinkert, P. K. (2003). Development of the First Force‐Controlled Robot for Otoneurosurgery. The Laryngoscope, 113(3), 465–471. https://doi.org/10.1097/00005537-200303000-00014
  15. Danilchenko, A., Balachandran, R., Toennies, J. L., Baron, S., Munske, B., Fitzpatrick, J. M., Withrow, T. J., Webster, R. J., & Labadie, R. F. (2011). Robotic Mastoidectomy. Otology & Neurotology, 32(1), 11–16. https://doi.org/10.1097/mao.0b013e3181fcee9e
  16. Noble, J. H., Majdani, O., Labadie, R. F., Dawant, B., & Fitzpatrick, J. M. (2010). Automatic determination of optimal linear drilling trajectories for cochlear access accounting for drill‐positioning error. The International Journal of Medical Robotics and Computer Assisted Surgery, 6(3), 281–290. https://doi.org/10.1002/rcs.330
  17. Labadie, R. F., Mitchell, J., Balachandran, R., & Fitzpatrick, J. M. (2009). Customized, rapid-production microstereotactic table for surgical targeting: description of concept and in vitro validation. International Journal of Computer Assisted Radiology and Surgery, 4(3), 273–280. https://doi.org/10.1007/s11548-009-0292-3
  18. Kratchman, L. B., Blachon, G. S., Withrow, T. J., Balachandran, R., Labadie, R. F., & Webster, R. J. (2011). Design of a Bone-Attached Parallel Robot for Percutaneous Cochlear Implantation. IEEE Transactions on Biomedical Engineering, 58(10), 2904–2910. https://doi.org/10.1109/tbme.2011.2162512
  19. Majdani, O., Bartling, S. H., Leinung, M., Stöver, T., Lenarz, M., Dullin, C., & Lenarz, T. (2008). A True Minimally Invasive Approach for Cochlear Implantation: High Accuracy in Cranial Base Navigation Through Flat-Panel-Based Volume Computed Tomography. Otology & Neurotology, 29(2), 120–123. https://doi.org/10.1097/mao.0b013e318157f7d8
  20. Majdani, O., Rau, T. S., Baron, S., Eilers, H., Baier, C., Heimann, B., Ortmaier, T., Bartling, S., Lenarz, T., & Leinung, M. (2009). A robot-guided minimally invasive approach for cochlear implant surgery: preliminary results of a temporal bone study. International Journal of Computer Assisted Radiology and Surgery, 4(5), 475–486. https://doi.org/10.1007/s11548-009-0360-8
  21. Hussong, A., Rau, T. S., Ortmaier, T., Heimann, B., Lenarz, T., & Majdani, O. (2009). An automated insertion tool for cochlear implants: another step towards atraumatic cochlear implant surgery. International Journal of Computer Assisted Radiology and Surgery, 5(2), 163–171. https://doi.org/10.1007/s11548-009-0368-0
  22. Bell, B., Stieger, C., Gerber, N., Arnold, A., Nauer, C., Hamacher, V., Kompis, M., Nolte, L., Caversaccio, M., & Weber, S. (2012). A self-developed and constructed robot for minimally invasive cochlear implantation. Acta Oto-Laryngologica, 132(4), 355–360. https://doi.org/10.3109/00016489.2011.642813
  23. Klenzner, T., Knapp, F. B., Schipper, J., Raczkowsky, J., Woern, H., Kahrs, L. A., Werner, M., & Hering, P. (2009). High precision cochleostomy by use of a pulsed CO2laser – an experimental approach. Cochlear Implants International, 10(sup1), 58–62. https://doi.org/10.1179/cim.2009.10.supplement-1.58
  24. Rau, T. S., Hussong, A., Leinung, M., Lenarz, T., & Majdani, O. (2009). Automated insertion of preformed cochlear implant electrodes: evaluation of curling behaviour and insertion forces on an artificial cochlear model. International Journal of Computer Assisted Radiology and Surgery, 5(2), 173–181. https://doi.org/10.1007/s11548-009-0299-9
  25. Nguyen, Y., Miroir, M., Kazmitcheff, G., Ferrary, E., Sterkers, O., & Grayeli, A. B. (2011). From Conception to Application of a Tele-Operated Assistance Robot for Middle Ear Surgery. Surgical Innovation, 19(3), 241–251. https://doi.org/10.1177/1553350611426012

1–25 of 52