A rat model for evaluating physiological responses to femoral shaft fracture reduction using a surgical robot
Description
AbstractThe first step in treatment of displaced femoral shaft fractures is adequate reduction of the fracture fragments. Manually performed, reduction can be challenging, and is frequently associated with soft tissue damage, especially when repeated reduction attempts are made. The magnitude of local and systemic inflammatory responses caused by prolonged and repeated reduction maneuvers has not been fully established. We devised an operative technique utilizing a robotic reduction device for use in a rat. A femoral fracture was simulated by means of an osteotomy. The robot enabled reproduction of both manual and guided precision reductions, performed in a single path movement. An external fixator was designed specifically to manipulate the rat femur and also for fixation of the osteotomy region. First, reduction accuracy was assessed in eight femurs, then the quality of fixator placement and reduction accuracy was analyzed in 22 femurs. In the first case, 100% of the femurs were accurately reduced. In the second case, 91% had successful stable fixation and an accurate reduction was achieved in 86% of the specimens. We demonstrated the feasibility of a model of robot‐assisted fracture reduction that could be used to analyze the effects of reduction on the surrounding soft tissue via biochemical and histopathological means. A future aspect will be to evaluate whether the robot confers an advantage in fracture reduction versus the conventional technique, which would have significant implications for the use of robotic devices in orthopaedic surgery. © 2008 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res
Additional details
Identifiers
- OpenAlex
- W2121560896
- PMID
- 18634014
- URL
- https://onlinelibrary.wiley.com/doi/10.1002/jor.20698
Dates
- Issued
-
July 16, 2008
References
- Bunn, J. R., Canning, J., Burke, G., Mushipe, M., Marsh, D. R., & Li, G. (2004). Production of consistent crush lesions in murine quadriceps muscle—A biomechanical, histomorphological and immunohistochemical study. Journal of Orthopaedic Research, 22(6), 1336–1344. https://doi.org/10.1016/j.orthres.2004.03.013
- Cipolle, M. D., Pasquale, M. D., Shearer, J., Caldwell, M., & Cerra, F. (1994). BLUNT INJURY AUGMENTS INTERLEUKIN-6 BUT NOT TUMOR NECROSIS FACTOR IN ISOLATED, PERFUSED RAT HINDLIMBS. The Journal of Trauma: Injury, Infection, and Critical Care, 37(1), 91–99. https://doi.org/10.1097/00005373-199407000-00016
- Gosling, T., Westphal, R., Hufner, T., Faulstich, J., Kfuri, M., Wahl, F., & Krettek, C. (2005). Robot-assisted fracture reduction: A preliminary study in the femur shaft. Medical and Biological Engineering and Computing, 43(1), 115–120. https://doi.org/10.1007/bf02345131
- Harwood, P. J., Giannoudis, P. V., van Griensven, M., Krettek, C., & Pape, H.-C. (2005). Alterations in the Systemic Inflammatory Response after Early Total Care and Damage Control Procedures for Femoral Shaft Fracture in Severely Injured Patients. The Journal of Trauma: Injury, Infection, and Critical Care, 58(3), 446–454. https://doi.org/10.1097/01.ta.0000153942.28015.77
- Levy, R. M., Prince, J. M., Yang, R., Mollen, K. P., Liao, H., Watson, G. A., Fink, M. P., Vodovotz, Y., & Billiar, T. R. (2006). Systemic inflammation and remote organ damage following bilateral femur fracture requires Toll-like receptor 4. American Journal of Physiology-Regulatory, Integrative and Comparative Physiology, 291(4), R970–R976. https://doi.org/10.1152/ajpregu.00793.2005
- Pape, H.-C., Hildebrand, F., Pertschy, S., Zelle, B., Garapati, R., Grimme, K., & Krettek, C. (2002). Changes in the Management of Femoral Shaft Fractures in Polytrauma Patients: From Early Total Care to Damage Control Orthopedic Surgery. The Journal of Trauma: Injury, Infection, and Critical Care, 53(3), 452–462. https://doi.org/10.1097/00005373-200209000-00010
- Pape, H.-C., Schmidt, R. E., Rice, J., van Griensven, M., das Gupta, R., Krettek, C., & Tscherne, H. (2000). Biochemical changes after trauma and skeletal surgery of the lower extremity: Quantification of the operative burden. Critical Care Medicine, 28(10), 3441–3448. https://doi.org/10.1097/00003246-200010000-00012
- Pasquale, M. D., Cipolle, M. D., Monaco, J., & Simon, N. (1996). Early inflammatory response correlates with the severity of injury. Critical Care Medicine, 24(7), 1238–1242. https://doi.org/10.1097/00003246-199607000-00029
- Wang, W., Smail, N., Wang, P., & Chaudry, I. H. (1998). Increased Gut Permeability after Hemorrhage Is Associated with Upregulation of Local and Systemic IL-6. Journal of Surgical Research, 79(1), 39–46. https://doi.org/10.1006/jsre.1998.5385
- https://doi.org/10.1080/10929080701657974 https://doi.org/10.1080/10929080701657974
- Roumen, R. M. H., Redl, H., Schlag, G., Zilow, G., Sandtner, W., Koller, W., Hendriks, T., & Goris, R. J. A. (1995). Inflammatory mediators in relation to the development of multiple organ failure in patients after severe blunt trauma. Critical Care Medicine, 23(3), 474–480. https://doi.org/10.1097/00003246-199503000-00010
Citations
- Zhou, X., Chen, Y., Miao, G., Guo, Y., Zhang, Q., & Bi, J. (2025). Computer-aided robotics for applications in fracture reduction surgery: Advances, challenges, and opportunities. iScience, 28(1), 111509. https://doi.org/10.1016/j.isci.2024.111509
- Alruwaili, F., Saeedi-Hosseiny, M. S., Guzman, L., McMillan, S., Iordachita, I. I., & Abedin-Nasab, M. H. (2022). A 3-Armed 6-DOF Parallel Robot for Femur Fracture Reduction: Trajectory and Force Testing. 2022 International Symposium on Medical Robotics (ISMR), 1–6. https://doi.org/10.1109/ismr48347.2022.9807539
- Saeedi-Hosseiny, M. S., Alruwaili, F., McMillan, S., Iordachita, I., & Abedin-Nasab, M. H. (2022). A Surgical Robotic System for Long-Bone Fracture Alignment: Prototyping and Cadaver Study. IEEE Transactions on Medical Robotics and Bionics, 4(1), 172–182. https://doi.org/10.1109/tmrb.2021.3129277
- ZHU, Q., TIAN, M., LIU, Q., & WANG, X. (2022). DESIGN, KINEMATICS AND MANIPULABILITY ANALYSES OF A SERIAL-LINK ROBOT FOR MINIMALLY INVASIVE TREATMENT IN FEMORAL SHAFT FRACTURES. Journal of Mechanics in Medicine and Biology, 22(09). https://doi.org/10.1142/s0219519422400607
- Alruwaili, F., Saeedi-Hosseiny, M. S., Clancy, M., McMillan, S., Iordachita, I. I., & Abedin-Nasab, M. H. (2022). Experimental Evaluation of a 3-Armed 6-DOF Parallel Robot for Femur Fracture Surgery. Journal of Medical Robotics Research, 07(04). https://doi.org/10.1142/s2424905x22410094
- Orelaja, O. A., Xingsong, W., Li, J., Sh Dauda, I., Afiz, I. A., Odunlami, S. A., Badmos, A. A., & Sharif, U. (2021). Design of a vibration damping robot and force evaluation in intraoperative robotic‐assisted femoral shaft repair using a modified soft damper. The International Journal of Medical Robotics and Computer Assisted Surgery, 18(1). https://doi.org/10.1002/rcs.2349
- https://doi.org/10.1177/01423312211000928
- Nguyen Phu, S., & Essomba, T. (2021). Kinematic analysis of an augmented 3-RPSP tripod mechanism with six degrees of freedom for bone reduction surgery. Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science, 236(8), 4059–4072. https://doi.org/10.1177/09544062211048044
- Abedin-Nasab, M. H., & Saeedi-Hosseiny, M. S. (2020). Robossis: Orthopedic Surgical Robot. In Handbook of Robotic and Image-Guided Surgery (pp. 515–528). Elsevier. https://doi.org/10.1016/b978-0-12-814245-5.00030-x
- Essomba, T., & Nguyen Phu, S. (2020). Kinematic Analysis and Design of a Six-Degrees of Freedom 3-RRPS Mechanism for Bone Reduction Surgery. Journal of Medical Devices, 15(1). https://doi.org/10.1115/1.4049057
- Bai, L., Yang, J., Chen, X., Sun, Y., & Li, X. (2019). Medical Robotics in Bone Fracture Reduction Surgery: A Review. Sensors, 19(16), 3593. https://doi.org/10.3390/s19163593
- Zheng, G., & Nolte, L.-P. (2018). Computer-Aided Orthopaedic Surgery: State-of-the-Art and Future Perspectives. In Advances in Experimental Medicine and Biology (pp. 1–20). Springer Singapore. https://doi.org/10.1007/978-981-13-1396-7_1
- Peterburs, B., Mittelstaedt, A., Haas, P., Petri, M., Westphal, R., Dullin, C., Sehmisch, S., & Neunaber, C. (2018). Biomechanical and histological analyses of the fracture healing process after direct or prolonged reduction. European Journal of Medical Research, 23(1). https://doi.org/10.1186/s40001-018-0337-6
- Panzica, M., Suero, E. M., Westphal, R., Citak, M., Liodakis, E., Hawi, N., Petri, M., Krettek, C., & Stuebig, T. (2017). Robotic distal locking of intramedullary nailing: Technical description and cadaveric testing. The International Journal of Medical Robotics and Computer Assisted Surgery, 13(4), Article e1831. https://doi.org/10.1002/rcs.1831
- Suero, E. M., Hartung, T., Westphal, R., Hawi, N., Liodakis, E., Citak, M., Krettek, C., & Stuebig, T. (2017). Improving the human–robot interface for telemanipulated robotic long bone fracture reduction: Joystick device vs. haptic manipulator. The International Journal of Medical Robotics and Computer Assisted Surgery, 14(1), Article e1863. https://doi.org/10.1002/rcs.1863
- Suero, E. M., Westphal, R., Citak, M., Hawi, N., Liodakis, E., Omar, M., Krettek, C., & Stuebig, T. (2017). Comparison of algorithms for automated femur fracture reduction. The International Journal of Medical Robotics and Computer Assisted Surgery, 14(1), Article e1864. https://doi.org/10.1002/rcs.1864
- Suero, E. M., Westphal, R., Citak, M., Stueber, V., Lueke, U., Krettek, C., & Stuebig, T. (2017). Repeatability and reproducibility of a telemanipulated fracture reduction system. Journal of Robotic Surgery, 12(3), 409–416. https://doi.org/10.1007/s11701-017-0749-2
- Zhu, Q., Liang, B., Wang, X., Sun, X., & Wang, L. (2017). Minimally invasive treatment of displaced femoral shaft fractures with a teleoperated robot-assisted surgical system. Injury, 48(10), 2253–2259. https://doi.org/10.1016/j.injury.2017.07.014
- Abedinnasab, M. H., Farahmand, F., & Gallardo-Alvarado, J. (2017). The Wide-Open Three-Legged Parallel Robot for Long-Bone Fracture Reduction. Journal of Mechanisms and Robotics, 9(1). https://doi.org/10.1115/1.4035495
- Neunaber, C., Wypior, H., Westphal, R., Petri, M., Goesling, T., Hildebrand, F., Krettek, C., & Haas, P. (2016). Repetitive reduction lead to significant elevated IL-6 and decreased IL-10 levels in femoral osteotomies: A quantitative analysis of a robot-assisted reduction process in a rat model. Injury, 47(8), 1669–1675. https://doi.org/10.1016/j.injury.2016.05.017
- Zhu, Q., Liang, B., Wang, X., Sun, X., & Wang, L. (2016). Force–torque intraoperative measurements for femoral shaft fracture reduction. Computer Assisted Surgery, 21(sup1), 37–44. https://doi.org/10.1080/24699322.2016.1240311
- Zhu, Q., Sun, X., Wang, X., Wu, Q., & Liang, B. (2015). Development of intraoperative noninvasive force measuring system during femoral fracture reduction. 2015 IEEE International Symposium on Medical Measurements and Applications (MeMeA) Proceedings, 335–339. https://doi.org/10.1109/memea.2015.7145223
- Zheng, G., & Nolte, L. P. (2015). Computer-Assisted Orthopedic Surgery: Current State and Future Perspective. Frontiers in Surgery, 2. https://doi.org/10.3389/fsurg.2015.00066
- Zheng, G., & Nolte, L.-P. (2013). Image-Guided Orthopaedic Surgery. In Intraoperative Imaging and Image-Guided Therapy (pp. 647–659). Springer New York. https://doi.org/10.1007/978-1-4614-7657-3_49
- Hüfner, T., Oszwald, M., Stübig, T., Brunnemer, U., Gösling, T., Krettek, C., & Citak, M. (2009). Femurschaftfraktur: Computergestützte Reposition und Torsionskontrolle. Trauma und Berufskrankheit, 11(3), 148–151. https://doi.org/10.1007/s10039-009-1493-2