Published January 25, 2022 | Journal article | Version v1 | https://doi.org/10.1093/ejcts/ezac016

4D-flow cardiac magnetic resonance imaging after aortic root replacement with long-valved decellularized aortic homografts: comparison to valve-sparing aortic root replacement and healthy controls

Description

Abstract OBJECTIVES Long-valved decellularized aortic homografts (DAH) may be used in young patients to treat aortic valve disease associated with aortic root dilatation, thereby eliminating the need for prosthetic material and anticoagulation. METHODS Thirty-three male subjects in 3 equally sized cohorts were compared: patients following DAH implantation with a median age of 29 years [interquartile range (IQR) 27.5–37.5], patients post-valve-sparing aortic root replacement (VSARR), median 44 years (IQR 31.5–49) and healthy controls, median 33 years (IQR 28–40, P = 0.228). Time-resolved three-dimensional phase-contrast cardiac magnetic resonance imaging was performed to assess maximum blood flow velocity, pulse wave velocity, mechanical energy loss (EL), wall shear stress and flow patterns (vorticity, eccentricity, helicity) in 5 different planes of the aorta. RESULTS The mean time between surgery and cardiovascular magnetic resonance was 2.56 ± 2.0 years in DAH vs 2.67 ± 2.1 in VSARR, P = 0.500. No significant differences in maximum velocity and pulse wave velocity were found between healthy controls and DAH across all planes. Velocity in the proximal aorta was significantly higher in VSARR (182.91 ± 53.91 cm/s, P = 0.032) compared with healthy controls. EL was significantly higher in VSARR in the proximal aorta with 1.85 mW (IQR 1.39–2.95) compared with healthy controls, 1.06 mW (0.91–1.22, P = 0.016), as well as in the entire thoracic aorta. In contrast, there was no significant EL in DAH in the proximal, 1.27 m/W (0.92–1.53, P = 0.296), as well as in the thoracic aorta, 7.7 m/W (5.25–9.90, P = 0.114), compared with healthy controls. There were no significant differences in wall shear stress parameters for all 5 regions of the thoracic aorta between the 3 groups. DAH patients, however, showed more vorticity, helicity and eccentricity in the ascending aorta compared with healthy controls (P < 0.019). CONCLUSIONS Decellularized long aortic homografts exhibit near to normal haemodynamic parameters 2.5 years postoperatively compared with healthy controls and VSARR.

Additional details

Funding

European Union's HORIZON 2020 Programme
643597
ROR icon European Commission
HORIZON2020

Dates

Issued
January 25, 2022

References

  1. Zhao, D. F., Seco, M., Wu, J. J., Edelman, J. B., Wilson, M. K., Vallely, M. P., Byrom, M. J., & Bannon, P. G. (2016). Mechanical Versus Bioprosthetic Aortic Valve Replacement in Middle-Aged Adults: A Systematic Review and Meta-Analysis. The Annals of Thoracic Surgery, 102(1), 315–327. https://doi.org/10.1016/j.athoracsur.2015.10.092
  2. Shrestha, M. L., Beckmann, E., Abd Alhadi, F., Krueger, H., Meyer-Bockenkamp, F., Bertele, S., Koigeldiyev, N., Kaufeld, T., Fleissner, F., Korte, W., Schmitto, J., Cebotari, S., Harringer, W., Haverich, A., & Martens, A. (2018). Elective David I Procedure Has Excellent Long-Term Results: 20-Year Single-Center Experience. The Annals of Thoracic Surgery, 105(3), 731–738. https://doi.org/10.1016/j.athoracsur.2017.08.040
  3. Tudorache, I., Horke, A., Cebotari, S., Sarikouch, S., Boethig, D., Breymann, T., Beerbaum, P., Bertram, H., Westhoff-Bleck, M., Theodoridis, K., Bobylev, D., Cheptanaru, E., Ciubotaru, A., & Haverich, A. (2016). Decellularized aortic homografts for aortic valve and aorta ascendens replacement. European Journal of Cardio-Thoracic Surgery, 50(1), 89–97. https://doi.org/10.1093/ejcts/ezw013
  4. Sekaran, N. K., Crowley, A. L., de Souza, F. R., Resende, E. S., & Rao, S. V. (2017). The Role for Cardiovascular Remodeling in Cardiovascular Outcomes. Current Atherosclerosis Reports, 19(5). https://doi.org/10.1007/s11883-017-0656-z
  5. Noda, C., Ambale Venkatesh, B., Ohyama, Y., Liu, C.-Y., Chamera, E., Redheuil, A., Teixido-Tura, G., Chugh, A. R., Wu, C. O., Hundley, G. W., Bluemke, D. A., & Lima, J. A. C. (2015). Reproducibility of functional aortic analysis using magnetic resonance imaging: the MESA. European Heart Journal – Cardiovascular Imaging, 17(8), 909–917. https://doi.org/10.1093/ehjci/jev215
  6. Hope, M. D., Hope, T. A., Crook, S. E. S., Ordovas, K. G., Urbania, T. H., Alley, M. T., & Higgins, C. B. (2011). 4D Flow CMR in Assessment of Valve-Related Ascending Aortic Disease. JACC: Cardiovascular Imaging, 4(7), 781–787. https://doi.org/10.1016/j.jcmg.2011.05.004
  7. Bissell, M. M., Hess, A. T., Biasiolli, L., Glaze, S. J., Loudon, M., Pitcher, A., Davis, A., Prendergast, B., Markl, M., Barker, A. J., Neubauer, S., & Myerson, S. G. (2013). Aortic Dilation in Bicuspid Aortic Valve Disease. Circulation: Cardiovascular Imaging, 6(4), 499–507. https://doi.org/10.1161/circimaging.113.000528
  8. Markl, M., Frydrychowicz, A., Kozerke, S., Hope, M., & Wieben, O. (2012). 4D flow MRI. Journal of Magnetic Resonance Imaging, 36(5), 1015–1036. https://doi.org/10.1002/jmri.23632
  9. Markl, M., Draney, M. T., Miller, D. C., Levin, J. M., Williamson, E. E., Pelc, N. J., Liang, D. H., & Herfkens, R. J. (2005). Time-resolved three-dimensional magnetic resonance velocity mapping of aortic flow in healthy volunteers and patients after valve-sparing aortic root replacement. The Journal of Thoracic and Cardiovascular Surgery, 130(2), 456–463. https://doi.org/10.1016/j.jtcvs.2004.08.056
  10. Kvitting, J.-P. E., Ebbers, T., Wigström, L., Engvall, J., Olin, C. L., & Bolger, A. F. (2004). Flow patterns in the aortic root and the aorta studied with time-resolved, 3-dimensional, phase-contrast magnetic resonance imaging: implications for aortic valve–sparing surgery. The Journal of Thoracic and Cardiovascular Surgery, 127(6), 1602–1607. https://doi.org/10.1016/j.jtcvs.2003.10.042
  11. Redheuil, A., Wu, C. O., Kachenoura, N., Ohyama, Y., Yan, R. T., Bertoni, A. G., Hundley, G. W., Duprez, D. A., Jacobs, D. R., Daniels, L. B., Darwin, C., Sibley, C., Bluemke, D. A., & Lima, J. A. C. (2014). Proximal Aortic Distensibility Is an Independent Predictor of All-Cause Mortality and Incident CV Events. Journal of the American College of Cardiology, 64(24), 2619–2629. https://doi.org/10.1016/j.jacc.2014.09.060
  12. Murgo, J. P., Westerhof, N., Giolma, J. P., & Altobelli, S. A. (1980). Aortic input impedance in normal man: relationship to pressure wave forms. Circulation, 62(1), 105–116. https://doi.org/10.1161/01.cir.62.1.105
  13. Vlachopoulos, C., Aznaouridis, K., & Stefanadis, C. (2010). Prediction of Cardiovascular Events and All-Cause Mortality With Arterial Stiffness. Journal of the American College of Cardiology, 55(13), 1318–1327. https://doi.org/10.1016/j.jacc.2009.10.061
  14. Laurent, S., Boutouyrie, P., Asmar, R., Gautier, I., Laloux, B., Guize, L., Ducimetiere, P., & Benetos, A. (2001). Aortic Stiffness Is an Independent Predictor of All-Cause and Cardiovascular Mortality in Hypertensive Patients. Hypertension, 37(5), 1236–1241. https://doi.org/10.1161/01.hyp.37.5.1236
  15. Ben-Shlomo, Y., Spears, M., Boustred, C., May, M., Anderson, S. G., Benjamin, E. J., Boutouyrie, P., Cameron, J., Chen, C.-H., Cruickshank, J. K., Hwang, S.-J., Lakatta, E. G., Laurent, S., Maldonado, J., Mitchell, G. F., Najjar, S. S., Newman, A. B., Ohishi, M., Pannier, B., … Wilkinson, I. B. (2014). Aortic Pulse Wave Velocity Improves Cardiovascular Event Prediction. Journal of the American College of Cardiology, 63(7), 636–646. https://doi.org/10.1016/j.jacc.2013.09.063
  16. Oechtering, T. H., Sieren, M. M., Hunold, P., Hennemuth, A., Huellebrand, M., Scharfschwerdt, M., Richardt, D., Sievers, H.-H., Barkhausen, J., & Frydrychowicz, A. (2020). Time-resolved 3-dimensional magnetic resonance phase contrast imaging (4D Flow MRI) reveals altered blood flow patterns in the ascending aorta of patients with valve-sparing aortic root replacement. The Journal of Thoracic and Cardiovascular Surgery, 159(3), 798–810.e1. https://doi.org/10.1016/j.jtcvs.2019.02.127
  17. Markl, M., Chan, F. P., Alley, M. T., Wedding, K. L., Draney, M. T., Elkins, C. J., Parker, D. W., Wicker, R., Taylor, C. A., Herfkens, R. J., & Pelc, N. J. (2003). Time‐resolved three‐dimensional phase‐contrast MRI. Journal of Magnetic Resonance Imaging, 17(4), 499–506. https://doi.org/10.1002/jmri.10272
  18. Reiter, U., Reiter, G., & Fuchsjäger, M. (2016). MR phase-contrast imaging in pulmonary hypertension. The British Journal of Radiology, 89(1063), 20150995. https://doi.org/10.1259/bjr.20150995
  19. Markl, M., Wallis, W., Brendecke, S., Simon, J., Frydrychowicz, A., & Harloff, A. (2010). Estimation of global aortic pulse wave velocity by flow‐sensitive 4D MRI. Magnetic Resonance in Medicine, 63(6), 1575–1582. https://doi.org/10.1002/mrm.22353
  20. Review of MRI-based measurements of pulse wave velocity: a biomarker of arterial stiffness
  21. Dyverfeldt, P., Ebbers, T., & Länne, T. (2014). Pulse wave velocity with 4D flow MRI: Systematic differences and age-related regional vascular stiffness. Magnetic Resonance Imaging, 32(10), 1266–1271. https://doi.org/10.1016/j.mri.2014.08.021
  22. Stalder, A. F., Russe, M. F., Frydrychowicz, A., Bock, J., Hennig, J., & Markl, M. (2008). Quantitative 2D and 3D phase contrast MRI: Optimized analysis of blood flow and vessel wall parameters. Magnetic Resonance in Medicine, 60(5), 1218–1231. https://doi.org/10.1002/mrm.21778
  23. Barker, A. J., van Ooij, P., Bandi, K., Garcia, J., Albaghdadi, M., McCarthy, P., Bonow, R. O., Carr, J., Collins, J., Malaisrie, S. C., & Markl, M. (2013). Viscous energy loss in the presence of abnormal aortic flow. Magnetic Resonance in Medicine, 72(3), 620–628. https://doi.org/10.1002/mrm.24962
  24. von Knobelsdorff-Brenkenhoff, F., Trauzeddel, R. F., Barker, A. J., Gruettner, H., Markl, M., & Schulz-Menger, J. (2014). Blood flow characteristics in the ascending aorta after aortic valve replacement—a pilot study using 4D-flow MRI. International Journal of Cardiology, 170(3), 426–433. https://doi.org/10.1016/j.ijcard.2013.11.034
  25. Geiger, J., Markl, M., Herzer, L., Hirtler, D., Loeffelbein, F., Stiller, B., Langer, M., & Arnold, R. (2011). Aortic flow patterns in patients with Marfan syndrome assessed by flow‐sensitive four‐dimensional MRI. Journal of Magnetic Resonance Imaging, 35(3), 594–600. https://doi.org/10.1002/jmri.23500

1–25 of 31

Citations

  1. Jodłowski, M., Hudziak, D., Bachowski, R., & Gocoł, R. (2026). Aortic Root Aneurysms: Pathophysiology, Indications for Intervention, and Contemporary Surgical Management Including Minimally Invasive Approaches. Life, 16(11), 1816. https://doi.org/10.3390/life16111816
  2. Kari, F. A., Czerny, M., Borger, M., Misfeld, M., Zimmer, E., Siepe, M., Hagl, C., Detter, C., Petersen, J., Richardt, D., Ensminger, S., Werner, P., Andreas, M., Pichlmaier, M., & Mueller, C. S. (2025). Valve-sparing aortic root replacement: Strategies to avoid residual aortic regurgitation. JTCVS Open, 24, 85–95. https://doi.org/10.1016/j.xjon.2025.02.015
  3. Cvitkovic, T., Horke, A., Bobylev, D., Avsar, M., Holst, T., Beerbaum, P., Boethig, D., Petena, E., Tsimashok, V., Westhoff-Bleck, M., Gutberlet, M., Beyer, F. H., Wacker, F., Ruhparwar, A., Vogel-Claussen, J., Sarikouch, S., & Czerner, C. (2025). Aortic Compliance After Root Replacement With Decellularized Homografts Versus in Donor Age-Matched Healthy Controls. Interdisciplinary CardioVascular and Thoracic Surgery, 41(1). https://doi.org/10.1093/icvts/ivaf303
  4. Yang, M., Nie, Z., Yue, H., Liang, W., & Wu, Z. (2025). Aortopathy associated with bicuspid aortic valve: advances in clinical and hemodynamics research. Frontiers in Physiology, 16. https://doi.org/10.3389/fphys.2025.1576072
  5. Shen, H., Zhou, W., ChunrongTu, Peng, Y., Li, X., Liu, D., Wang, X., Zhang, X., Zeng, X., & Zhang, J. (2024). Thoracic aorta injury detected by 4D flow MRI predicts subsequent main adverse cardiovascular events in breast cancer patients receiving anthracyclines: A longitudinal study. Magnetic Resonance Imaging, 109, 67–73. https://doi.org/10.1016/j.mri.2024.03.010
  6. Horke, A., Bobylev, D., Avsar, M., Cvitkovic, T., Meyns, B., Rega, F., Hazekamp, M., Cesnjevar, R., Schmiady, M., Staebler, B., Dewald, O., Ciubotaru, A., Michel-Behnke, I., Zimpfer, D., Jashari, R., Boethig, D., Cebotari, S., Beerbaum, P., Tudorache, I., & Sarikouch, S. (2024). Paediatric aortic valve replacement using decellularized allografts: a multicentre update following 143 implantations and five-year mean follow-up. European Journal of Cardio-Thoracic Surgery, 65(4). https://doi.org/10.1093/ejcts/ezae112
  7. Horke, A., Tudorache, I., Laufer, G., Andreas, M., Pomar, J. L., Pereda, D., Quintana, E., Sitges, M., Meyns, B., Rega, F., Hazekamp, M., Cesnjevar, R., Schmiady, M. O., Pepper, J., Rosendahl, U., Lichtenberg, A., Stadnik, D., Jashari, R., Boethig, D., … Sarikouch, S. (2024). Five-year results from a prospective, single-arm European trial on decellularized allografts for aortic valve replacement—the ARISE Study and ARISE Registry Data. European Journal of Cardio-Thoracic Surgery, 65(4). https://doi.org/10.1093/ejcts/ezae121
  8. Sarikouch, S., Ruhparwar, A., & Horke, A. (2023). Möglichkeiten des Aortenklappenersatzes beim jungen Erwachsenen: dezellularisierte menschliche Spenderklappen. Zeitschrift für Herz-,Thorax- und Gefäßchirurgie, 38(1), 23–28. https://doi.org/10.1007/s00398-023-00611-4
  9. Andreeva, A., Coti, I., Werner, P., Scherzer, S., Kocher, A., Laufer, G., & Andreas, M. (2023). Aortic Valve Replacement in Adult Patients with Decellularized Homografts: A Single-Center Experience. Journal of Clinical Medicine, 12(21), 6713. https://doi.org/10.3390/jcm12216713
  10. Peterss, S., Hagl, C., & Pichlmaier, M. (2022). Of hypes and paradigms in the search of the ideal valved conduit in the young. European Journal of Cardio-Thoracic Surgery, 61(6), 1316–1317. https://doi.org/10.1093/ejcts/ezac134