Derivation of aortic distensibility and pulse wave velocity by image registration with a physics‐based regularisation term
Authors/Creators
-
1.
University of Sheffield
-
2.
King's College London
-
3.
Medizinische Hochschule Hannover
- 4. Department of Cardiovascular Science University of Sheffield Sheffield UK
Description
SUMMARYAnalysis of the cardiovascular system represents a classical problem in which the solid and fluid phases interact intimately, and so is a rich field of application for state‐of‐the‐art fluid–solid interaction (FSI) analyses. In this paper, we focus on the human aorta. Solution of the full FSI problem requires knowledge of the material properties of the wall and information on vessel support. We show that variation of distensibility along the aorta can be obtained from four‐dimensional image data using image registration. If pressure data at one point in the vessel are available, these can be converted to absolute values. Alternatively, values of pulse wave velocity along the vessel can be obtained. The quality of the extracted data is improved by the incorporation into the registration of a regularisation term based on the one‐dimensional wave equation. The method has been validated using simulated data. For idealised vessels, the accuracy with which the distensibility and wave velocity can be extracted is high (1%–2%). The method is applied to six clinical datasets from patients with mild coarctation, for which it is shown that wave velocity along the aorta is relatively constant. Copyright © 2013 John Wiley & Sons, Ltd.
Additional details
Identifiers
- OpenAlex
- W2155294643
- PMID
- 24123929
- URL
- https://onlinelibrary.wiley.com/doi/10.1002/cnm.2589
Dates
- Issued
-
October 10, 2013
References
- Blacher, J., Asmar, R., Djane, S., London, G. M., & Safar, M. E. (1999). Aortic Pulse Wave Velocity as a Marker of Cardiovascular Risk in Hypertensive Patients. Hypertension, 33(5), 1111–1117. https://doi.org/10.1161/01.hyp.33.5.1111
- Hirata, K., Kawakami, M., & O'Rourke, M. F. (2006). Pulse Wave Analysis and Pulse Wave Velocity A Review of Blood Pressure Interpretation 100 Years After Korotkov. Circulation Journal, 70(10), 1231–1239. https://doi.org/10.1253/circj.70.1231
- Lehmann, E. D., Hopkins, K. D., Rawesh, A., Joseph, R. C., Kongola, K., Coppack, S. W., & Gosling, R. G. (1998). Relation Between Number of Cardiovascular Risk Factors/Events and Noninvasive Doppler Ultrasound Assessments of Aortic Compliance. Hypertension, 32(3), 565–569. https://doi.org/10.1161/01.hyp.32.3.565
- Ibrahim, E.-S. H., Johnson, K. R., Miller, A. B., Shaffer, J. M., & White, R. D. (2010). Measuring aortic pulse wave velocity using high-field cardiovascular magnetic resonance: comparison of techniques. Journal of Cardiovascular Magnetic Resonance, 12(1), 26. https://doi.org/10.1186/1532-429x-12-26
- Formaggia, L., Gerbeau, J. F., Nobile, F., & Quarteroni, A. (2001). On the coupling of 3D and 1D Navier–Stokes equations for flow problems in compliant vessels. Computer Methods in Applied Mechanics and Engineering, 191(6-7), 561–582. https://doi.org/10.1016/s0045-7825(01)00302-4
- Wolters, B. J. B. M., Rutten, M. C. M., Schurink, G. W. H., Kose, U., de Hart, J., & van de Vosse, F. N. (2005). A patient-specific computational model of fluid–structure interaction in abdominal aortic aneurysms. Medical Engineering & Physics, 27(10), 871–883. https://doi.org/10.1016/j.medengphy.2005.06.008
- Vignon-Clementel, I. E., Alberto Figueroa, C., Jansen, K. E., & Taylor, C. A. (2006). Outflow boundary conditions for three-dimensional finite element modeling of blood flow and pressure in arteries. Computer Methods in Applied Mechanics and Engineering, 195(29-32), 3776–3796. https://doi.org/10.1016/j.cma.2005.04.014
- Lam, S. K., Fung, G. S. K., Cheng, S. W. K., & Chow, K. W. (2008). A computational study on the biomechanical factors related to stent-graft models in the thoracic aorta. Medical & Biological Engineering & Computing, 46(11), 1129–1138. https://doi.org/10.1007/s11517-008-0361-8
- Tan, F. P. P., Borghi, A., Mohiaddin, R. H., Wood, N. B., Thom, S., & Xu, X. Y. (2009). Analysis of flow patterns in a patient-specific thoracic aortic aneurysm model. Computers & Structures, 87(11-12), 680–690. https://doi.org/10.1016/j.compstruc.2008.09.007
- Kim, H. J., Vignon-Clementel, I. E., Figueroa, C. A., LaDisa, J. F., Jansen, K. E., Feinstein, J. A., & Taylor, C. A. (2009). On Coupling a Lumped Parameter Heart Model and a Three-Dimensional Finite Element Aorta Model. Annals of Biomedical Engineering, 37(11), 2153–2169. https://doi.org/10.1007/s10439-009-9760-8
- Benim, A. C., Nahavandi, A., Assmann, A., Schubert, D., Feindt, P., & Suh, S. H. (2011). Simulation of blood flow in human aorta with emphasis on outlet boundary conditions. Applied Mathematical Modelling, 35(7), 3175–3188. https://doi.org/10.1016/j.apm.2010.12.022
- Coogan, J. S., Chan, F. P., Taylor, C. A., & Feinstein, J. A. (2011). Computational fluid dynamic simulations of aortic coarctation comparing the effects of surgical‐ and stent‐based treatments on aortic compliance and ventricular workload. Catheterization and Cardiovascular Interventions, 77(5), 680–691. https://doi.org/10.1002/ccd.22878
- Liu, X., Fan, Y., Deng, X., & Zhan, F. (2011). Effect of non-Newtonian and pulsatile blood flow on mass transport in the human aorta. Journal of Biomechanics, 44(6), 1123–1131. https://doi.org/10.1016/j.jbiomech.2011.01.024
- Bajcsy, R., & Kovačič, S. (1989). Multiresolution elastic matching. Computer Vision, Graphics, and Image Processing, 46(1), 1–21. https://doi.org/10.1016/s0734-189x(89)80014-3
- Christensen, G. E., Rabbitt, R. D., & Miller, M. I. (1996). Deformable templates using large deformation kinematics. IEEE Transactions on Image Processing, 5(10), 1435–1447. https://doi.org/10.1109/83.536892
- Fast fluid registration of medical images. Visualization in biomedical computing
- Hagemann, A., Rohr, K., Stiehl, H. S., Spetzger, U., & Gilsbach, J. M. (1999). Biomechanical modeling of the human head for physically based, nonrigid image registration. IEEE Transactions on Medical Imaging, 18(10), 875–884. https://doi.org/10.1109/42.811267
- J R Womersley. (1957). Oscillatory Flow in Arteries: the Constrained Elastic Tube as a Model of Arterial Flow and Pulse Transmission. Physics in Medicine & Biology, 2(2), 178–187. https://doi.org/10.1088/0031-9155/2/2/305
- Bramwell, J. C., & Hill, A. V. (1922). The velocity of pulse wave in man. Proceedings of the Royal Society of London. Series B, Containing Papers of a Biological Character, 93(652), 298–306. https://doi.org/10.1098/rspb.1922.0022
- Hardy, C. J., Bolster, B. D., McVeigh, E. R., Adams, W. J., & Zerhouni, E. A. (1994). A one‐dimensional velocity technique for NMR measurement of aortic distensibility. Magnetic Resonance in Medicine, 31(5), 513–520. https://doi.org/10.1002/mrm.1910310507
- Dogui, A., Kachenoura, N., Frouin, F., Lefort, M., De Cesare, A., Mousseaux, E., & Herment, A. (2011). Consistency of aortic distensibility and pulse wave velocity estimates with respect to the Bramwell-Hill theoretical model: a cardiovascular magnetic resonance study. Journal of Cardiovascular Magnetic Resonance, 13(1), 11. https://doi.org/10.1186/1532-429x-13-11
- Wemple, R. R., & Mockros, L. F. (1972). Pressure and flow in the systemic arterial system. Journal of Biomechanics, 5(6), 629–641. https://doi.org/10.1016/0021-9290(72)90035-8
- Barber, D. C., Oubel, E., Frangi, A. F., & Hose, D. R. (2007). Efficient computational fluid dynamics mesh generation by image registration. Medical Image Analysis, 11(6), 648–662. https://doi.org/10.1016/j.media.2007.06.011
- Chapelle, D., & Bathe, K.-J. (2011). The Finite Element Analysis of Shells - Fundamentals. In Computational Fluid and Solid Mechanics. Springer Berlin Heidelberg. https://doi.org/10.1007/978-3-642-16408-8
- Brown, A. G., Shi, Y., Marzo, A., Staicu, C., Valverde, I., Beerbaum, P., Lawford, P. V., & Hose, D. R. (2012). Accuracy vs. computational time: Translating aortic simulations to the clinic. Journal of Biomechanics, 45(3), 516–523. https://doi.org/10.1016/j.jbiomech.2011.11.041
1–25 of 27
Citations
- Vigneswaran, T. V., Sinha, M. D., Valverde, I., Simpson, J. M., & Charakida, M. (2017). Hypertension in Coarctation of the Aorta: Challenges in Diagnosis in Children. Pediatric Cardiology, 39(1), 1–10. https://doi.org/10.1007/s00246-017-1739-x
- Kehl, S., & Gee, M. W. (2016). Calibration of parameters for cardiovascular models with application to arterial growth. International Journal for Numerical Methods in Biomedical Engineering, 33(5). https://doi.org/10.1002/cnm.2822
- https://doi.org/10.1109/tbme.2014.2343673
- Lamata, P., Casero, R., Carapella, V., Niederer, S. A., Bishop, M. J., Schneider, J. E., Kohl, P., & Grau, V. (2014). Images as drivers of progress in cardiac computational modelling. Progress in Biophysics and Molecular Biology, 115(2-3), 198–212. https://doi.org/10.1016/j.pbiomolbio.2014.08.005