Reference values for jitter recorded by concentric needle electrodes in healthy controls: A multicenter study
Authors/Creators
-
1.
Uppsala University
-
2.
Duke Medical Center
- 3. Department of Clinical Neurophysiology Queen Elizabeth Hospital Birmingham, University Hospitals Birmingham NHS Foundation Trust Birmingham UK
-
4.
Karolinska University Hospital
-
5.
Wellcome Trust
-
6.
Ljubljana University Medical Centre
- 7. Department of Clinical Medicine The Artic University of Norway Tromsø Norway
- 8. Department of Clinical Neurophysiology University Hospital of North Norway Tromsø Norway
-
9.
Universidade de São Paulo
- 10. Fleury Medicina e Saúde São Paulo Brazil
- 11. San Rafael University Hospital Granada Spain
- 12. Department of Clinical Neurophysiology Ibermutuamur Granada Spain
- 13. Department of Clinical Neurophysiology Vithas Virgen del Mar Hospital Almeria Spain
- 14. Doctoral Program in Clinical Medicine and Public Health University of Granada Granada Spain
-
15.
Mayo Clinic
-
16.
Karolinska Institutet
- 17. Neuromuscular Investigation Laboratory Faculdade Medicina São José do Rio Preto São Paulo Brazil
Description
ABSTRACT Introduction: The aim of this study was to create reference values for jitter measured with concentric needle electrodes. Methods: Operators worldwide contributed recordings from orbicularis oculi (OO), frontalis (FR), and extensor digitorum (ED) muscles in healthy controls. Criteria for acceptable signal quality were agreed upon in advance. Fifteen or 20 recordings of acceptable quality from each muscle were required for voluntary and electrical stimulation recordings, respectively. Results: Recordings from 59 to 92 subjects were obtained for each muscle and activation type. Outlier limits for mean consecutive difference and individual jitter data for voluntary activation were: OO, 31 and 45 µs; FR, 28 and 38 µs; ED, 30 and 43 µs; and for electrical stimulation they were: OO, 27 and 36 µs; FR, 21 and 28 µs; ED, 24 and 35 µs. Conclusion: Reference jitter values from concentric needle electrode recordings were developed from signals of defined quality while seeking to avoid creating supernormal values. Muscle Nerve 53: 351–362, 2016
Additional details
Identifiers
- OpenAlex
- W1869806335
- PMID
- 26112058
- URL
- https://onlinelibrary.wiley.com/doi/10.1002/mus.24750
Funding
- Swedish Brain Foundation (Hjarnfonden)
Dates
- Issued
-
November 13, 2015
References
- Erta?, M., Baslo, M. B., Yildiz, N., Yazici, J., & �ge, A. E. (2000). Concentric needle electrode for neuromuscular jitter analysis. Muscle & Nerve, 23(5), 715–719. https://doi.org/10.1002/(sici)1097-4598(200005)23:5%3C715::aid-mus8%3E3.0.co;2-v
- Benatar, M., Hammad, M., & Doss‐Riney, H. (2006). Concentric‐needle single‐fiber electromyography for the diagnosis of myasthenia gravis. Muscle & Nerve, 34(2), 163–168. https://doi.org/10.1002/mus.20568
- Stålberg, E. V., & Sanders, D. B. (2009). Jitter recordings with concentric needle electrodes. Muscle & Nerve, 40(3), 331–339. https://doi.org/10.1002/mus.21424
- Narayanaswami, P., Pantoja‐Galicia, N., Betensky, R. A., & Rutkove, S. B. (2012). Application of futility analysis to refine jitter recordings in myasthenia gravis. Muscle & Nerve, 45(4), 486–491. https://doi.org/10.1002/mus.22340
- Sanders, D. B. (2002). Clinical impact of single-fiber electromyography. Muscle & Nerve, 999(S11), S15–S20. https://doi.org/10.1002/mus.10141
- Kouyoumdjian, J. A., & Stålberg, E. V. (2008). Reference jitter values for concentric needle electrodes in voluntarily activated extensor digitorum communis and orbicularis oculi muscles. Muscle & Nerve, 37(6), 694–699. https://doi.org/10.1002/mus.21043
- Kouyoumdjian, J. A., & Stålberg, E. V. (2011). Concentric needle jitter on stimulated Orbicularis Oculi in 50 healthy subjects. Clinical Neurophysiology, 122(3), 617–622. https://doi.org/10.1016/j.clinph.2010.07.012
- Kouyoumdjian, J. A., & Stålberg, E. V. (2013). Concentric needle jitter on voluntary activated frontalis in 20 healthy subjects. Muscle & Nerve, 47(3), 440–442. https://doi.org/10.1002/mus.23710
- Thiele, B., & Stalberg, E. (1974). The bimodal jitter: a single fibre electromyographic finding. Journal of Neurology, Neurosurgery & Psychiatry, 37(4), 403–411. https://doi.org/10.1136/jnnp.37.4.403
- EMG, A. H. C. of T. A. S. I. G. on S. F., & Gilchrist, J. M. (1992). Single fiber EMG reference values: A collaborative effort. Muscle & Nerve, 15(2), 151–161. https://doi.org/10.1002/mus.880150205
- Trontelj, J. V., & Stålberg, E. (1992). Jitter measurement by axonal micro-stimulation. Guidelines and technical notes. Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section, 85(1), 30–37. https://doi.org/10.1016/0168-5597(92)90098-v
- Ekstedt, J., Nilsson, G., & Stalberg, E. (1974). Calculation of the electromyographic jitter. Journal of Neurology, Neurosurgery & Psychiatry, 37(5), 526–539. https://doi.org/10.1136/jnnp.37.5.526
- Propagation velocity in single human muscle fibres
- Sarrigiannis, P. G., Kennett, R. P., Read, S., & Farrugia, M. E. (2005). Single‐fiber EMG with a concentric needle electrode: Validation in myasthenia gravis. Muscle & Nerve, 33(1), 61–65. https://doi.org/10.1002/mus.20435
- Kouyoumdjian, J. A., & Stålberg, E. V. (2007). Concentric needle single fiber electromyography: normative jitter values on voluntary activated Extensor Digitorum Communis. Arquivos De Neuro-Psiquiatria, 65(2b), 446–449. https://doi.org/10.1590/s0004-282x2007000300016
- Kouyoumdjian, J. A., & Stålberg, E. V. (2012). Concentric needle jitter in stimulated frontalis in 20 healthy subjects. Muscle & Nerve, 45(2), 276–278. https://doi.org/10.1002/mus.22306
- Kokubun, N., Sonoo, M., Imai, T., Arimura, Y., Kuwabara, S., Komori, T., Kobayashi, M., Nagashima, T., Hatanaka, Y., Tsuda, E., Misawa, S., Abe, T., & Arimura, K. (2012). Reference values for voluntary and stimulated single-fibre EMG using concentric needle electrodes: A multicentre prospective study. Clinical Neurophysiology, 123(3), 613–620. https://doi.org/10.1016/j.clinph.2011.07.044
- Cattaneo, L., Cucurachi, L., & Pavesi, G. (2007). Concentric needle recording of neuromuscular jitter in the temporalis muscle. Neurophysiologie Clinique/Clinical Neurophysiology, 37(1), 50–51. https://doi.org/10.1016/j.neucli.2007.02.001
- Bischoff, C., Stålberg, E., Falck, B., & Eeg‐Olofsson, K. E. (1994). Reference values of motor unit action potentials obtained with multi‐MUAP analysis. Muscle & Nerve, 17(8), 842–851. https://doi.org/10.1002/mus.880170803
- Stalberg, E., & Trontelj, J. V. (1970). Demonstration of axon reflexes in human motor nerve fibres. Journal of Neurology, Neurosurgery & Psychiatry, 33(5), 571–579. https://doi.org/10.1136/jnnp.33.5.571
- Aris Kouyoumdjian, J., Fanani, A. C. da S., & Stålberg, E. V. (2011). Concentric needle jitter on stimulated frontalis and extensor digitorum in 20 myasthenia gravis patients. Muscle & Nerve, 44(6), 912–918. https://doi.org/10.1002/mus.22203
Citations
- Morena, J. M. (2026). Electrodiagnostic Approach to Defects of Neuromuscular Transmission. Muscle & Nerve. https://doi.org/10.1002/mus.70146
- Fidancı, H., Alaydın, H. C., Ertürk, A. Y., Eke, M. N., & Önal, O. (2026). Repetitive nerve stimulation findings in iatrogenic botulism compared with myasthenia gravis. Neurological Sciences, 47(1). https://doi.org/10.1007/s10072-026-08810-1
- Cornacchini, S., Verza, M. U., Spagni, G., Beretta, F., Farina, A., Bastianelli, M., Cassardo, A., Mei, C., Lotti, A., Barilaro, A., Massacesi, L., Damato, V., & Grippo, A. (2026). Stimulated single-fiber electromyography in the diagnostic workup of diplopia and ptosis. Clinical Neurophysiology Practice, 11, 796–803. https://doi.org/10.1016/j.cnp.2026.09.004
- Vesperinas, A., Rocaspana-Codana, J., Reyes-Leiva, D., Caballero-Ávila, M., Carbayo, Á., Collet-Vidiella, R., Llansó, L., Gallardo, E., Turon-Sans, J., Rojas-García, R., & Cortés-Vicente, E. (2026). Challenges in myasthenia gravis diagnosis: an analysis of the diagnostic process of myasthenia gravis in a specialized clinic. Neuromuscular Disorders, 59, 106284. https://doi.org/10.1016/j.nmd.2025.106284
- León-Ruiz, M., Ghosh, R., Bole, K., Dubey, S., & Benito-León, J. (2026). Clarifications to “Isolated bilateral facial palsy as the initial presenting manifestation of generalized myasthenia gravis preceding myasthenic crisis”: The importance of not forgetting single-fiber electromyography. Neurología, 41(8), 502027. https://doi.org/10.1016/j.nrl.2026.502027
- León-Ruiz, M., Ghosh, R., Bole, K., Dubey, S., & Benito-León, J. (2026). Clarifications to “Isolated bilateral facial palsy as the initial presenting manifestation of generalized myasthenia gravis preceding myasthenic crisis”: the importance of not forgetting single-fiber electromyography. Neurología (English Edition), 41(8), 502027. https://doi.org/10.1016/j.nrleng.2026.502027
- Trillenberg, P., & Ohlen, D. S. (2025). Utility of the Predictive Summary Index for Comparison of Diagnostic Protocols in Myasthenia Gravis With Repetitive Nerve Stimulation and Concentric Needle Jitter. Brain and Behavior, 15(11). https://doi.org/10.1002/brb3.71016
- Natarajan, V., & Verma, S. (2025). Orbicularis Oculi Stimulated Jitter Analysis in Children With Autoimmune Myasthenia Gravis. Muscle & Nerve, 71(4), 593–599. https://doi.org/10.1002/mus.28363
- Kouyoumdjian, J. A., & Graca, C. R. (2025). Concentric Needle Jitter Measurements in Voluntarily Activated Deltoid Muscle in Healthy Control Subjects. Muscle & Nerve, 71(6), 1076–1080. https://doi.org/10.1002/mus.28376
- Lainez, E., Llauradó, A., Gratacòs-Viñola, M., Seoane, J. L., Trallero-Araguás, E., Ariño, H., Roca-Herrera, M., Juntas, R., & Raguer, N. (2025). Electrophysiological findings in immune checkpoint inhibitor-related neuromuscular events. Clinical Neurophysiology, 179, 2110989. https://doi.org/10.1016/j.clinph.2025.2110989
- Valle, C., Malanda, A., Garnés-Camarena, O., Stashuk, D. W., Azkona, G., Rodríguez-Falces, J., & Navallas, J. (2025). Peaks or threshold-crossing: A comparative analysis of neuromuscular jitter measurement methods. Journal of Electromyography and Kinesiology, 85, 103065. https://doi.org/10.1016/j.jelekin.2025.103065
- León-Ruiz, M., Rízea, C., Álvarez-Troncoso, J., Quintana-Díaz, M., Zmork-Martínez, G., Benito-León, J., & Rodríguez-Pardo, J. (2025). Myasthenic crisis probably triggered by local lidocaine infiltration unveiling generalized myasthenia gravis without extraocular muscle involvement. Neurology Perspectives, 5(3), 100193. https://doi.org/10.1016/j.neurop.2025.100193
- Trillenberg, P., & Otto, M. (2025). Diagnostik von Endplattenstörungen mit Jitter-Bestimmung mit der konzentrischen Nadelelektrode. Klinische Neurophysiologie, 56(03), 141–149. https://doi.org/10.1055/a-2537-9652
- Kouyoumdjian, J. A., Yamamoto, L. A. R., & Graca, C. R. (2025). Reply to the letter “Long-COVID may not be explained by skeletal muscle involvement, but rather by other, more compelling pathophysiological concepts”. Arquivos De Neuro-Psiquiatria, 83(10), 001–002. https://doi.org/10.1055/s-0045-1812889
- https://doi.org/10.1097/wnp.0000000000001164
- https://doi.org/10.2139/ssrn.5333563
- https://doi.org/10.3389/fneur.2025.1586031
- https://doi.org/10.3390/toxins17080407
- Cosentino, G., Prunetti, P., Tammam, G., Zaffina, C., Gastaldi, M., Tassorelli, C., Alfonsi, E., & Todisco, M. (2024). Diagnostic accuracy of voluntary and stimulated neuromuscular jitter studies in ocular myasthenia gravis. Muscle & Nerve. https://doi.org/10.1002/mus.28202
- Gengadharan, P. N., Ong, W. T., Tan, J. Y., Shahrizaila, N., Goh, K. J., & Tan, C. Y. (2024). Ocular Myasthenia gravis: determining the predictive factors of secondary generalisation. Acta Neurologica Belgica, 125(2), 351–358. https://doi.org/10.1007/s13760-024-02693-9
- Mousavi, A., Kumar, P., & Frykman, H. (2024). The changing landscape of autoantibody testing in myasthenia gravis in the setting of novel drug treatments. Clinical Biochemistry, 133-134, 110826. https://doi.org/10.1016/j.clinbiochem.2024.110826
- Bhandari, V., Sivadasan, A., Barnett-Tapia, C., Katzberg, H., & Bril, V. (2024). Using jitter analysis with concentric needle electrodes to assess disease status and treatment responses in myasthenia gravis. Clinical Neurophysiology Practice, 9, 227–232. https://doi.org/10.1016/j.cnp.2024.06.004
- Zambelis, T., Zouvelou, V., & Anagnostou, E. (2024). SFEMG in extensor digitorum communis and tibialis anterior: Relative sensitivity in myasthenia gravis. Neurophysiologie Clinique, 54(4), 102957. https://doi.org/10.1016/j.neucli.2024.102957
- Koysuren, A., & Temucin, C. M. (2024). Concentric needle jitter analysis of the genioglossus muscle in patients with motor neuron disease. Neurological Research, 46(6), 578–582. https://doi.org/10.1080/01616412.2024.2339096
- https://doi.org/10.1212/wnl.0000000000209395
1–25 of 73