On the interdependence of insertion forces, insertion speed, and lubrication: Aspects to consider when testing cochlear implant electrodes

Description

Objectives During the insertion of cochlear implant (CI) electrode arrays, forces occur which may cause trauma and poorer hearing outcomes. Unfortunately, research groups investigating factors influencing insertion forces come to contradicting results, especially regarding insertion speed. This study was conducted to investigate the origin of these contradicting results and to determine how different testing conditions influence experimental findings. Methods Repeated, automated insertions with three different FLEX28 CI electrode arrays (MED-EL, Innsbruck, Austria) were performed into a newly developed, anatomically correct and 3D-printed mean scala tympani phantom. The testing protocol for each electrode included variations in insertion speed (v = 0.1–2.0 mm/s) and lubrication (90%, 50%, and 10% liquid soap), resulting in 51 insertions per electrode array and a total of 153 insertions. Results The test setup and protocol allowed for repeatable insertions with only minimal change in the morphology of the insertion force profiles per testing condition. Strong but varying dependencies of the maximal insertion forces and work were found regarding both lubrication and speed: work-speed dependency is constant for the 10% lubricant, negative for the 50% lubricant and positive for the 90% lubricant. Conclusion Our results can explain part of the contradicting results found within previous studies by translating interrelations known from lubricated rubber friction to the field of CI electrode array insertion. We show that the main driver behind measured bulk forces are most likely the generated friction forces, which are strongly dependent on insertion speed and lubrication. The employed test setup allows for conducting repeatable and comparable insertion studies, which can be recapitulated by other centers due to the detailed explanation of the test setup as well as the developed and freely available insertion phantom. This study hence represents another important step toward standardizing CI array insertion testing.

Additional details

Dates

Issued
January 24, 2024

References

  1. Wilson, B. S. (2008). Cochlear implants: Current designs and future possibilities. The Journal of Rehabilitation Research and Development, 45(5), 695–730. https://doi.org/10.1682/jrrd.2007.10.0173
  2. JBNN. Anatomy of the Round Window and Hook Region of the Cochlea With Implications for Cochlear Implantation and Other Endocochlear Surgical Procedures.
  3. Wysocki, J. (1999). Dimensions of the human vestibular and tympanic scalae. Hearing Research, 135(1-2), 39–46. https://doi.org/10.1016/s0378-5955(99)00088-x
  4. Intracochlear placement of cochlear implant electrodes in soft surgery technique
  5. Investigation of the effect of cochlear implant electrode length on speech comprehension in quiet and noise compared with the results with users of electro-acoustic-stimulation, a retrospective analysis.
  6. Caversaccio, M., Wimmer, W., Anso, J., Mantokoudis, G., Gerber, N., Rathgeb, C., Schneider, D., Hermann, J., Wagner, F., Scheidegger, O., Huth, M., Anschuetz, L., Kompis, M., Williamson, T., Bell, B., Gavaghan, K., Weber, S., & Pérez-Fernández, N. (2019). Robotic middle ear access for cochlear implantation: First in man. PLOS ONE, 14(8), e0220543. https://doi.org/10.1371/journal.pone.0220543
  7. Nguyen, Y., Kazmitcheff, G., De Seta, D., Miroir, M., Ferrary, E., & Sterkers, O. (2014). Definition of Metrics to Evaluate Cochlear Array Insertion Forces Performed with Forceps, Insertion Tool, or Motorized Tool in Temporal Bone Specimens. BioMed Research International, 2014, 1–9. https://doi.org/10.1155/2014/532570
  8. Salcher, R., John, S., Stieghorst, J., Kluge, M., Repp, F., Fröhlich, M., & Lenarz, T. (2022). Minimally Invasive Cochlear Implantation: First-in-Man of Patient-Specific Positioning Jigs. Frontiers in Neurology, 13. https://doi.org/10.3389/fneur.2022.829478
  9. Shepherd, R. K., Pyman, B. C., Clark, G. M., & Webb, R. L. (1985). Banded Intracochlear Electrode Array: Evaluation of Insertion Trauma in Human Temporal Bones. Annals of Otology, Rhinology & Laryngology, 94(1), 55–59. https://doi.org/10.1177/000348948509400112
  10. Kennedy, D. W. (1987). Multichannel intracochlear electrodes: Mechanism of insertion trauma. The Laryngoscope, 97(1), 42–49. https://doi.org/10.1288/00005537-198701000-00011
  11. Eshraghi, A. A., Yang, N. W., & Balkany, T. J. (2003). Comparative Study of Cochlear Damage With Three Perimodiolar Electrode Designs. The Laryngoscope, 113(3), 415–419. https://doi.org/10.1097/00005537-200303000-00005
  12. Roland, J. T. (2005). A Model for Cochlear Implant Electrode Insertion and Force Evaluation: Results with a New Electrode Design and Insertion Technique. The Laryngoscope, 115(8), 1325–1339. https://doi.org/10.1097/01.mlg.0000167993.05007.35
  13. Avci, E., Nauwelaers, T., Hamacher, V., & Kral, A. (2017). Three-Dimensional Force Profile During Cochlear Implantation Depends on Individual Geometry and Insertion Trauma. Ear & Hearing, 38(3), e168–e179. https://doi.org/10.1097/aud.0000000000000394
  14. Hügl, S., Blum, T., Lenarz, T., Majdani, O., & Rau, T. S. (2018). Impact of anatomical variations on insertion forces. Current Directions in Biomedical Engineering, 4(1), 509–512. https://doi.org/10.1515/cdbme-2018-0122
  15. Clark, J. R., Warren, F. M., & Abbott, J. J. (2011). A Scalable Model for Human Scala-Tympani Phantoms. Journal of Medical Devices, 5(1). https://doi.org/10.1115/1.4002932
  16. Miroir, M., Nguyen, Y., Kazmitcheff, G., Ferrary, E., Sterkers, O., & Grayeli, A. B. (2012). Friction Force Measurement During Cochlear Implant Insertion. Otology & Neurotology, 33(6), 1092–1100. https://doi.org/10.1097/mao.0b013e31825f24de
  17. Aebischer, P., Caversaccio, M., & Wimmer, W. (2021). Fabrication of human anatomy-based scala tympani models with a hydrophilic coating for cochlear implant insertion experiments. Hearing Research, 404, Article 108205. https://doi.org/10.1016/j.heares.2021.108205
  18. Starovoyt, A., Shaheen, E., Putzeys, T., Kerckhofs, G., Politis, C., Wouters, J., & Verhaert, N. (2023). Anatomically and mechanically accurate scala tympani model for electrode insertion studies. Hearing Research, 430, 108707. https://doi.org/10.1016/j.heares.2023.108707
  19. Fung, Y.-C. (1993). Bioviscoelastic Solids. In Biomechanics (pp. 242–320). Springer New York. https://doi.org/10.1007/978-1-4757-2257-4_7
  20. Zuniga, M. G., Hügl, S., Engst, B. G., Lenarz, T., & Rau, T. S. (2021). The Effect of Ultra-slow Velocities on Insertion Forces: A Study Using a Highly Flexible Straight Electrode Array. Otology & Neurotology, 42(8), e1013–e1021. https://doi.org/10.1097/mao.0000000000003148
  21. Aebischer, P., Mantokoudis, G., Weder, S., Anschuetz, L., Caversaccio, M., & Wimmer, W. (2022). In-Vitro Study of Speed and Alignment Angle in Cochlear Implant Electrode Array Insertions. IEEE Transactions on Biomedical Engineering, 69(1), 129–137. https://doi.org/10.1109/tbme.2021.3088232
  22. A simple tool to automate the insertion process in cochlear implant surgery
  23. Kaufmann, C. R., Henslee, A. M., Claussen, A., & Hansen, M. R. (2020). Evaluation of Insertion Forces and Cochlea Trauma Following Robotics-Assisted Cochlear Implant Electrode Array Insertion. Otology & Neurotology, 41(5), 631–638. https://doi.org/10.1097/mao.0000000000002608
  24. Dohr, D., Fiedler, N., Schmidt, W., Grabow, N., Mlynski, R., & Schraven, S. P. (2021). Frictional Behavior of Cochlear Electrode Array Is Dictated by Insertion Speed and Impacts Insertion Force. Applied Sciences, 11(11), 5162. https://doi.org/10.3390/app11115162
  25. Kobler, J.-P., Dhanasingh, A., Kiran, R., Jolly, C., & Ortmaier, T. (2015). Cochlear Dummy Electrodes for Insertion Training and Research Purposes: Fabrication, Mechanical Characterization, and Experimental Validation. BioMed Research International, 2015, 1–9. https://doi.org/10.1155/2015/574209

1–25 of 66

Citations

  1. Rivière, M., Morice, C., Tourrel, G., Laborde, A., Malaquin, L., & Foncy, J. (2026). Three-dimensional printing of human scala tympani models: surface modification to reduce cochlear implant insertion forces with a physiological lubricant. Scientific Reports, 16(1). https://doi.org/10.1038/s41598-026-63614-9
  2. Sümer, B., & Aşkın, G. Ş. (2025). A tribological investigation of cochlear implant electrode arrays with different wire shapes. Tribology International, 209, 110679. https://doi.org/10.1016/j.triboint.2025.110679
  3. Timm, M. E., Avallone, E., Timm, M., Salcher, R. B., Rudnik, N., Lenarz, T., & Schurzig, D. (2025). Anatomical Considerations for Achieving Optimized Outcomes in Individualized Cochlear Implantation. Otology & Neurotology, 46(7), e234–e242. https://doi.org/10.1097/mao.0000000000004520
  4. Cramer, J., Böttcher-Rebmann, G., Fröhlich, M., Artukarslan, E., Timm, M. E., Majdani, O., Lenarz, T., & Rau, T. S. (2025). Robot-assisted Versus Manual: Intracochlear Forces During and After Cochlear Implant Electrode Insertion Show Benefits of Automation and Electrode Guidance. Otology & Neurotology, 47(1), 81–89. https://doi.org/10.1097/mao.0000000000004636
  5. Rudnik, N., Timm, M., Salcher, R., & Lenarz, T. (2025). Surgical Considerations for Partial Cochlear Implant Insertion. Otology & Neurotology, 47(2), e275–e282. https://doi.org/10.1097/mao.0000000000004769
  6. Cramer, J., Salcher, R., Fröhlich, M., Böttcher-Rebmann, G., Artukarslan, E., Lenarz, T., & Rau, T. S. (2025). Preclinical evaluation of a hydraulic actuation system with guide tube for robotic cochlear implant electrode insertion. BioMedical Engineering OnLine, 24(1). https://doi.org/10.1186/s12938-025-01338-z
  7. Haumann, S., Timm, M. E., Büchner, A., Lenarz, T., & Salcher, R. B. (2025). Does the audiogram shape influence the intracochlear recording of Electrocochleography during and after cochlear implantation?. Frontiers in Neuroscience, 18. https://doi.org/10.3389/fnins.2024.1530216
  8. Fröhlich, M., Deutz, J., Wangenheim, M., Rau, T. S., Lenarz, T., Kral, A., & Schurzig, D. (2024). The role of pressure and friction forces in automated insertion of cochlear implants. Frontiers in Neurology, 15. https://doi.org/10.3389/fneur.2024.1430694