In vitro validation of phase‐contrast flow measurements at 3 T in comparison to 1.5 T: Precision, accuracy, and signal‐to‐noise ratios
Description
AbstractPurposeTo evaluate the signal‐to‐noise ratio (SNR), precision, and accuracy of phase‐contrast flow measurements at 3 T with the help of an in vitro model and to compare the results with data from two 1.5‐T scanners.Materials and MethodsUsing an identical setup of a laminar flow model and sequence parameters, measurements were done at one 3‐T and at two 1.5‐T systems. Precision, accuracy, and SNR were obtained for velocity encodings ranging from 55 up to 550 cm−1. SNRs were calculated from the magnitude as well as the flow encoded images.ResultsPrecision and accuracy for the in vitro flow model were similarly high in all scanners with no significant difference. For velocity encodings from 55 cm−1 up to 550 cm−1, the SNR in magnitude as well as phase encoded images of the 3‐T measurements was approximately 2.5 times higher than the SNR obtained from the two 1.5‐T systems.ConclusionEven without optimization for the 3‐T environment, flow measurements show the same high accuracy and precision as is known from clinical 1.5‐T scanners. The superior SNR at 3 T will allow further improvements in temporal and spatial resolution. This will be of interest for small‐size vessels like coronary arteries or for slow diastolic flow patterns. J. Magn. Reson. Imaging 2005;21:604–610. © 2005 Wiley‐Liss, Inc.
Additional details
Identifiers
- OpenAlex
- W2045277904
- PMID
- 15834905
- URL
- https://onlinelibrary.wiley.com/doi/10.1002/jmri.20275
Funding
- Deutsche Forschungsgemeinschaft (DFG)
- Fe 206/8-1-723/01
Dates
- Issued
-
April 15, 2005
References
- Moran, P. R., Moran, R. A., & Karstaedt, N. (1985). Verification and evaluation of internal flow and motion. True magnetic resonance imaging by the phase gradient modulation method. Radiology, 154(2), 433–441. https://doi.org/10.1148/radiology.154.2.3966130
- Zananiri, F. V., Jackson, P. C., Goddard, P. R., Davies, E. R., & Wells, P. N. T. (1991). An evaluation of the accuracy of flow measurements using magnetic resonance imaging (MRI). Journal of Medical Engineering & Technology, 15(4-5), 170–176. https://doi.org/10.3109/03091909109023704
- Boesiger, P., Maier, S. E., Kecheng, L., Scheidegger, M. B., & Meier, D. (1992). Visualization and quantification of the human blood flow by magnetic resonance imaging. Journal of Biomechanics, 25(1), 55–67. https://doi.org/10.1016/0021-9290(92)90245-v
- Moran, P. R. (1982). A flow velocity zeugmatographic interlace for NMR imaging in humans. Magnetic Resonance Imaging, 1(4), 197–203. https://doi.org/10.1016/0730-725x(82)90170-9
- O'Donnell, M. (1985). NMR blood flow imaging using multiecho, phase contrast sequences. Medical Physics, 12(1), 59–64. https://doi.org/10.1118/1.595736
- Phase contrast cine magnetic resonance imaging
- Maier, S. E., Meier, D., Boesiger, P., Moser, U. T., & Vieli, A. (1989). Human abdominal aorta: comparative measurements of blood flow with MR imaging and multigated Doppler US. Radiology, 171(2), 487–492. https://doi.org/10.1148/radiology.171.2.2649924
- EVANS, A. J., IWAI, F., GRIST, T. A., SOSTMAN, H. D., HEDLUND, L. W., SPRITZER, C. E., NEGRO-VILAR, R., BEAM, C. A., & PELC, N. J. (1993). Magnetic Resonance Imaging of Blood Flow with a Phase Subtraction Technique. Investigative Radiology, 28(2), 109–115. https://doi.org/10.1097/00004424-199302000-00004
- Globits, S., Pacher, R., Frank, H., Pacher, B., Mayr, H., Neuhold, A., & Glogar, D. (1995). Comparative Assessment of Right Ventricular Volumes and Ejection Fraction by Thermodilution and Magnetic Resonance Imaging in Dilated Cardiomyopathy. Cardiology, 86(1), 67–72. https://doi.org/10.1159/000176833
- Bakker, C. J. G., Hoogeveen, R. M., & Viergever, M. A. (1999). Construction of a protocol for measuring blood flow by two-dimensional phase-contrast MRA. Journal of Magnetic Resonance Imaging, 9(1), 119–127. https://doi.org/10.1002/(sici)1522-2586(199901)9:1%3C119::aid-jmri16%3E3.0.co;2-f
- Lotz, J., Meier, C., Leppert, A., & Galanski, M. (2002). Cardiovascular Flow Measurement with Phase-Contrast MR Imaging: Basic Facts and Implementation. RadioGraphics, 22(3), 651–671. https://doi.org/10.1148/radiographics.22.3.g02ma11651
- Greil, G., Geva, T., Maier, S. E., & Powell, A. J. (2002). Effect of acquisition parameters on the accuracy of velocity encoded cine magnetic resonance imaging blood flow measurements. Journal of Magnetic Resonance Imaging, 15(1), 47–54. https://doi.org/10.1002/jmri.10029
- Noeske, R., Seifert, F., Rhein, K.-H., & Rinneberg, H. (2000). Human cardiac imaging at 3 T using phased array coils. Magnetic Resonance in Medicine, 44(6), 978–982. https://doi.org/10.1002/1522-2594(200012)44:6%3C978::aid-mrm22%3E3.0.co;2-9
- Wen, H., Denison, T. J., Singerman, R. W., & Balaban, R. S. (1997). The Intrinsic Signal-to-Noise Ratio in Human Cardiac Imaging at 1.5, 3, and 4 T. Journal of Magnetic Resonance, 125(1), 65–71. https://doi.org/10.1006/jmre.1996.1072
- Blechinger, J. C., Madsen, E. L., & Frank, G. R. (1988). Tissue‐mimicking gelatin–agar gels for use in magnetic resonance imaging phantoms. Medical Physics, 15(4), 629–636. https://doi.org/10.1118/1.596219
- Martin Bland, J., & Altman, D. (1986). STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT. The Lancet, 327(8476), 307–310. https://doi.org/10.1016/s0140-6736(86)90837-8
- Hinton, D. P., Wald, L. L., Pitts, J., & Schmitt, F. (2003). Comparison of Cardiac MRI on 1.5 and 3.0 Tesla Clinical Whole Body Systems. Investigative Radiology, 38(7), 436–442. https://doi.org/10.1097/01.rli.0000067489.31556.70
- Bernstein, M. A., Huston, J., Lin, C., Gibbs, G. F., & Felmlee, J. P. (2001). High‐resolution intracranial and cervical MRA at 3.0T: Technical considerations and initial experience. Magnetic Resonance in Medicine, 46(5), 955–962. https://doi.org/10.1002/mrm.1282
- Ocali, O., & Atalar, E. (1998). Ultimate intrinsic signal‐to‐noise ratio in MRI. Magnetic Resonance in Medicine, 39(3), 462–473. https://doi.org/10.1002/mrm.1910390317
- Andersen, A. H., & Kirsch, J. E. (1996). Analysis of noise in phase contrast MR imaging. Medical Physics, 23(6), 857–869. https://doi.org/10.1118/1.597729
- Pelc, N. J., Bernstein, M. A., Shimakawa, A., & Glover, G. H. (1991). Encoding strategies for three‐direction phase‐contrast MR imaging of flow. Journal of Magnetic Resonance Imaging, 1(4), 405–413. https://doi.org/10.1002/jmri.1880010404
- Bernstein, M. A., & Ikezaki, Y. (1991). Comparison of phase‐difference and complex‐difference processing in phase‐contrast MR angiography. Journal of Magnetic Resonance Imaging, 1(6), 725–729. https://doi.org/10.1002/jmri.1880010620
- Conturo, T. E., & Smith, G. D. (1990). Signal‐to‐noise in phase angle reconstruction: Dynamic range extension using phase reference offsets. Magnetic Resonance in Medicine, 15(3), 420–437. https://doi.org/10.1002/mrm.1910150308
- Kim, H.-W., Buckley, D. L., Peterson, D. M., Duensing, G. R., Caserta, J., Fitzsimmons, J., & Blackband, S. J. (2003). In Vivo Prostate Magnetic Resonance Imaging and Magnetic Resonance Spectroscopy at 3 Tesla Using a Transceive Pelvic Phased Array Coil. Investigative Radiology, 38(7), 443–451. https://doi.org/10.1097/01.rli.0000065425.29042.8d
- Niitsu, M., Nakai, T., Ikeda, K., Tang, G.-Y., Yoshioka, H., & Itai, Y. (2000). HIGH-RESOLUTION MR IMAGING OF THE KNEE AT 3 T. Acta Radiologica, 41(1), 84–88. https://doi.org/10.1034/j.1600-0455.2000.041001084.x
1–25 of 26
Citations
- https://doi.org/10.70675/305db4d2z2479z40e4za093z67a17cce36bf
- https://doi.org/10.70675/f0f81dcezfe61z4491z91b3z6897777d34c0
- Daud, E., Trauzeddel, R. F., Müller, M., Vestjens, L. T. W., Gröschel, J., Viezzer, D., Hadler, T., Blaszczyk, E., Jin, N., Giese, D., Schmitter, S., & Schulz-Menger, J. (2025). Assessing reliability and comparability of 4D flow CMR whole heart measurements using retrospective valve tracking: A single-vendor study in the Berlin research network. Magnetic Resonance Imaging, 119, 110368. https://doi.org/10.1016/j.mri.2025.110368
- https://doi.org/10.7759/cureus.87154
- Schmitter, S., & Schnell, S. (2024). 4D Flow MRI. In Quantification of Biophysical Parameters in Medical Imaging (pp. 215–237). Springer International Publishing. https://doi.org/10.1007/978-3-031-61846-8_10
- https://doi.org/10.1186/s41747-024-00435-3
- https://doi.org/10.14814/phy2.70078
- https://doi.org/10.2463/mrms.rev.2021-0104
- https://doi.org/10.3390/diagnostics11020325
- Varghese, J., Craft, J., Crabtree, C. D., Liu, Y., Jin, N., Chow, K., Ahmad, R., & Simonetti, O. P. (2020). Assessment of cardiac function, blood flow and myocardial tissue relaxation parameters at 0.35 T. NMR in Biomedicine, 33(7). https://doi.org/10.1002/nbm.4317
- https://doi.org/10.21203/rs.2.10741/v3
- https://doi.org/10.1186/s12880-019-0404-7
- https://doi.org/10.1186/s12968-019-0586-8
- https://doi.org/10.1186/s41747-019-0089-2
- Bidhult, S., Töger, J., Heiberg, E., Carlsson, M., Arheden, H., Aletras, A. H., & Hedström, E. (2018). Independent validation of metric optimized gating for fetal cardiovascular phase‐contrast flow imaging. Magnetic Resonance in Medicine, 81(1), 495–503. https://doi.org/10.1002/mrm.27392
- Hessenthaler, A., Gaddum, N. R., Holub, O., Sinkus, R., Röhrle, O., & Nordsletten, D. (2017). Experiment for validation of fluid‐structure interaction models and algorithms. International Journal for Numerical Methods in Biomedical Engineering, 33(9). https://doi.org/10.1002/cnm.2848
- Loecher, M., & Ennis, D. B. (2017). Velocity reconstruction with nonconvex optimization for low‐velocity‐encoding phase‐contrast MRI. Magnetic Resonance in Medicine, 80(1), 42–52. https://doi.org/10.1002/mrm.26997
- Francois, C. (2017). MR Flow and Quantification. In Protocols and Methodologies in Basic Science and Clinical Cardiac MRI (pp. 325–345). Springer International Publishing. https://doi.org/10.1007/978-3-319-53001-7_10
- Schmitter, S., & Schnell, S. (2017). 4D Flow MRI. In Quantification of Biophysical Parameters in Medical Imaging (pp. 187–212). Springer International Publishing. https://doi.org/10.1007/978-3-319-65924-4_9
- Karmonik, C., Anderson, J. R., Elias, S., Klucznik, R., Diaz, O., Zhang, Y. J., Grossman, R. G., & Britz, G. W. (2017). Four-Dimensional Phase Contrast Magnetic Resonance Imaging Protocol Optimization Using Patient-Specific 3-Dimensional Printed Replicas for In Vivo Imaging Before and After Flow Diverter Placement. World Neurosurgery, 105, 775–782. https://doi.org/10.1016/j.wneu.2017.06.042
- https://doi.org/10.1136/heartjnl-2016-310819
- Schmitter, S., Schnell, S., Uğurbil, K., Markl, M., & Van de Moortele, P. (2016). Towards high‐resolution 4D flow MRI in the human aorta using kt‐GRAPPA and B1+ shimming at 7T. Journal of Magnetic Resonance Imaging, 44(2), 486–499. https://doi.org/10.1002/jmri.25164
- Correia de Verdier, M., & Wikström, J. (2016). Normal ranges and test-retest reproducibility of flow and velocity parameters in intracranial arteries measured with phase-contrast magnetic resonance imaging. Neuroradiology, 58(5), 521–531. https://doi.org/10.1007/s00234-016-1661-6
- https://doi.org/10.1177/0271678x16631149
- Peng, S., Su, P., Wang, F., Cao, Y., Zhang, R., Lu, H., & Liu, P. (2015). Optimization of phase‐contrast MRI for the quantification of whole‐brain cerebral blood flow. Journal of Magnetic Resonance Imaging, 42(4), 1126–1133. https://doi.org/10.1002/jmri.24866
1–25 of 78