Insertion trauma of a cochlear implant electrode array with Nitinol inlay
Additional details
Identifiers
- OpenAlex
- W2296195481
- PMID
- 26961519
- URL
- http://link.springer.com/10.1007/s00405-016-3955-z
Funding
Dates
- Issued
-
March 9, 2016
References
- ASTM 2082 (2006) ASTM Standard F 2082-06: standard test method for determination of transformation temperature of nickel–titanium shape memory alloys by bend and free recovery
- Avci, E., Nauwelaers, T., Lenarz, T., Hamacher, V., & Kral, A. (2014). Variations in microanatomy of the human cochlea. Journal of Comparative Neurology, 522(14), 3245–3261. https://doi.org/10.1002/cne.23594
- Barras, C. D. J., & Myers, K. A. (2000). Nitinol – Its Use in Vascular Surgery and Other Applications. European Journal of Vascular and Endovascular Surgery, 19(6), 564–569. https://doi.org/10.1053/ejvs.2000.1111
- Briggs, R. J. S., Tykocinski, M., Xu, J., Risi, F., Svehla, M., Cowan, R., Stöver, T., Erfurt, P., & Lenarz, T. (2006). Comparison of Round Window and Cochleostomy Approaches with a Prototype Hearing Preservation Electrode. Audiology and Neurotology, 11(Suppl. 1), 42–48. https://doi.org/10.1159/000095613
- Burghard, A., Lenarz, T., Kral, A., & Paasche, G. (2014). Insertion site and sealing technique affect residual hearing and tissue formation after cochlear implantation. Hearing Research, 312, 21–27. https://doi.org/10.1016/j.heares.2014.02.002
- Buytaert, J., Goyens, J., De Greef, D., Aerts, P., & Dirckx, J. (2014). Volume Shrinkage of Bone, Brain and Muscle Tissue in Sample Preparation for Micro-CT and Light Sheet Fluorescence Microscopy (LSFM). Microscopy and Microanalysis, 20(4), 1208–1217. https://doi.org/10.1017/s1431927614001329
- Chen, B., Kha, H. N., & Clark, G. M. (2007). Development of a steerable cochlear implant electrode array. In IFMBE Proceedings (pp. 607–610). Springer Berlin Heidelberg. https://doi.org/10.1007/978-3-540-68017-8_152
- Corbet, S. S. (1997). Multi-electrode cochlear implant and method of manufacturing the same. The Journal of the Acoustical Society of America, 102(4), 1924. https://doi.org/10.1121/1.419663
- Driscoll, C. L. W., Carlson, M. L., Fama, A. F., & Lane, J. I. (2011). Evaluation of the hybrid‐L24® electrode using microcomputed tomography. The Laryngoscope, 121(7), 1508–1516. https://doi.org/10.1002/lary.21837
- Duerig, T., Pelton, A., & Stöckel, D. (1999). An overview of nitinol medical applications. Materials Science and Engineering: A, 273-275, 149–160. https://doi.org/10.1016/s0921-5093(99)00294-4
- Eshraghi, A. A., Yang, N. W., & Balkany, T. J. (2003). Comparative Study of Cochlear Damage With Three Perimodiolar Electrode Designs. The Laryngoscope, 113(3), 415–419. https://doi.org/10.1097/00005537-200303000-00005
- Friedmann, D. R., Peng, R., Fang, Y., McMenomey, S. O., Roland, J. T., & Waltzman, S. B. (2015). Effects of loss of residual hearing on speech performance with the CI422 and the Hybrid-L electrode. Cochlear Implants International, 16(5), 277–284. https://doi.org/10.1179/1754762815y.0000000008
- Gantz, B. J., Turner, C., Gfeller, K. E., & Lowder, M. W. (2005). Preservation of Hearing in Cochlear Implant Surgery: Advantages of Combined Electrical and Acoustical Speech Processing. The Laryngoscope, 115(5), 796–802. https://doi.org/10.1097/01.mlg.0000157695.07536.d2
- Gibson P, Darley I, Treaba C, Parker J, Dadd F (2011) Insertion tool for a cochlear implant electrode array. US 7,894,916 B2
- Hochmair, I., Nopp, P., Jolly, C., Schmidt, M., Schößer, H., Garnham, C., & Anderson, I. (2006). MED-EL Cochlear Implants: State of the Art and a Glimpse Into the Future. Trends in Amplification, 10(4), 201–219. https://doi.org/10.1177/1084713806296720
- Hughes, M. L., & Abbas, P. J. (2006). Electrophysiologic channel interaction, electrode pitch ranking, and behavioral threshold in straight versus perimodiolar cochlear implant electrode arrays. The Journal of the Acoustical Society of America, 119(3), 1538–1547. https://doi.org/10.1121/1.2164969
- Incerti, P. V., Ching, T. Y. C., & Cowan, R. (2013). A Systematic Review of Electric-Acoustic Stimulation. Trends in Amplification, 17(1), 3–26. https://doi.org/10.1177/1084713813480857
- Irving, S., Gillespie, L., Richardson, R., Rowe, D., Fallon, J. B., & Wise, A. K. (2014). Electroacoustic Stimulation: Now and into the Future. BioMed Research International, 2014, 1–17. https://doi.org/10.1155/2014/350504
- Jurawitz, M.-C., Büchner, A., Harpel, T., Schüssler, M., Majdani, O., Lesinski-Schiedat, A., & Lenarz, T. (2014). Hearing Preservation Outcomes with Different Cochlear Implant Electrodes: Nucleus® Hybrid™-L24 and Nucleus Freedom™ CI422. Audiology and Neurotology, 19(5), 293–309. https://doi.org/10.1159/000360601
- Kiefer, J., Pok, M., Adunka, O., Stürzebecher, E., Baumgartner, W., Schmidt, M., Tillein, J., Ye, Q., & Gstoettner, W. (2005). Combined Electric and Acoustic Stimulation of the Auditory System: Results of a Clinical Study. Audiology and Neurotology, 10(3), 134–144. https://doi.org/10.1159/000084023
- Kuzma JA (2000) Cochlear electrode array with positioning stylet. US 6,119,044
- Lenarz, T., James, C., Cuda, D., Fitzgerald O'Connor, A., Frachet, B., Frijns, J. H. M., Klenzner, T., Laszig, R., Manrique, M., Marx, M., Merkus, P., Mylanus, E. A. M., Offeciers, E., Pesch, J., Ramos-Macias, A., Robier, A., Sterkers, O., & Uziel, A. (2013). European multi-centre study of the Nucleus Hybrid L24 cochlear implant. International Journal of Audiology, 52(12), 838–848. https://doi.org/10.3109/14992027.2013.802032
- Lenarz, T., Stöver, T., Buechner, A., Lesinski-Schiedat, A., Patrick, J., & Pesch, J. (2009). Hearing Conservation Surgery Using the Hybrid-L Electrode. Audiology and Neurotology, 14(Suppl. 1), 22–31. https://doi.org/10.1159/000206492
- Lenarz, T., Stöver, T., Buechner, A., Paasche, G., Briggs, R., Risi, F., Pesch, J., & Battmer, R.-D. (2006). Temporal Bone Results and Hearing Preservation with a New Straight Electrode. Audiology and Neurotology, 11(Suppl. 1), 34–41. https://doi.org/10.1159/000095612
- Majdani O, Lenarz T, Harbach L, Pawsey N, Waldmann B, Rau TS (2014a) Insertion under water: cooling the temporal bone for insertion of a new experimental shape memory cochlear implant electrode. In: Proceedings of 14th symposium on cochlear implants and children, December 11–13, Vanderbilt University Medical Center, Nashville
1–25 of 49
Citations
- Chen, Y., Parvez, M. M., & Liou, F. (2025). Modification of TiNi alloy by fast pulse laser heat treatment. The International Journal of Advanced Manufacturing Technology, 139(9-10), 5109–5117. https://doi.org/10.1007/s00170-025-16227-x
- Walia, A., Shew, M. A., Smetak, M., Ortmann, A., Durakovic, N., Jiramongkolchai, P., Lefler, S., Herzog, J. A., & Buchman, C. A. (2025). Perimodiolar Electrode Locations Outperform Lateral Wall Arrays When Controlling for Cochlear Health and Speech Processing Strategy. Otology & Neurotology, 47(2), 257–265. https://doi.org/10.1097/mao.0000000000004699
- Canfarotta, M. W., Dillon, M. T., Thompson, N. J., Selleck, A. M., Dedmon, M. M., & Brown, K. D. (2024). Effects of Insertion Depth and Modiolar Proximity on Cochlear Implant Speech Recognition Outcomes With a Precurved Electrode Array. Otology & Neurotology, 46(3), 272–278. https://doi.org/10.1097/mao.0000000000004405
- Rau, T. S., Ehmann, T., Zuniga, M. G., Plaskonka, K., Keck, A., Majdani, O., & Lenarz, T. (2022). Toward a cochlear implant electrode array with shape memory effect for post‐insertion perimodiolar positioning. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 110(11), 2494–2505. https://doi.org/10.1002/jbm.b.35107
- Malfeld, K., Armbrecht, N., Volk, H. A., Lenarz, T., & Scheper, V. (2021). In Situ 3D-Imaging of the Inner Ear Synapses with a Cochlear Implant. Life, 11(4), 301. https://doi.org/10.3390/life11040301