A binaural loudness model for evaluating round-window stimulation based on a physiological peripheral auditory front-end module
Additional details
Identifiers
Funding
-
Deutsche Forschungsgemeinschaft
- EXC 2177/1 - Project ID 390895286
- Priority Academic Program Development of Jiangsu Higher Education Institutions
-
National Natural Science Foundation of China
- 52275296
-
Deutsche Forschungsgemeinschaft
- EXC 2177: Hearing4all 390895286
Dates
- Issued
-
December 2026
References
- Banakis Hartl, R. M., & Jenkins, H. A. (2020). Implantable Hearing Aids: Where are we in 2020?. Laryngoscope Investigative Otolaryngology, 5(6), 1184–1191. https://doi.org/10.1002/lio2.495
- Bentler, R. A., & Pavlovic, C. V. (1989). Transfer Functions and Correction Factors Used in Hearing Aid Evaluation and Research. Ear and Hearing, 10(1), 58–63. https://doi.org/10.1097/00003446-198902000-00010
- Byrne, D., Dillon, H., Ching, T., Katsch, R., & Keidser, G. (2001). NAL-NL1 Procedure for Fitting Nonlinear Hearing Aids: Characteristics and Comparisons with Other Procedures. Journal of the American Academy of Audiology, 12(01), 37–51. https://doi.org/10.1055/s-0041-1741117
- Chen, Z., Hu, G., Glasberg, B. R., & Moore, B. C. J. (2011). A new method of calculating auditory excitation patterns and loudness for steady sounds. Hearing Research, 282(1-2), 204–215. https://doi.org/10.1016/j.heares.2011.08.001
- Colletti, V., Soli, S. D., Carner, M., & Colletti, L. (2006). Treatment of mixed hearing losses via implantation of a vibratory transducer on the round window. International Journal of Audiology, 45(10), 600–608. https://doi.org/10.1080/14992020600840903
- Adapting hearing devices to the individual ear acoustics: database and target response correction functions for various device styles
- Elliott, S. J., & Ni, G. (2018). An elemental approach to modelling the mechanics of the cochlea. Hearing Research, 360, 14–24. https://doi.org/10.1016/j.heares.2017.10.013
- Elliott, S. J., Ni, G., & Verschuur, C. A. (2016). Modelling the effect of round window stiffness on residual hearing after cochlear implantation. Hearing Research, 341, 155–167. https://doi.org/10.1016/j.heares.2016.08.006
- Fletcher, H., & Munson, W. A. (1933). Loudness, Its Definition, Measurement and Calculation. The Journal of the Acoustical Society of America, 5(2), 82–108. https://doi.org/10.1121/1.1915637
- Greenwood, D. D. (1990). A cochlear frequency-position function for several species—29 years later. The Journal of the Acoustical Society of America, 87(6), 2592–2605. https://doi.org/10.1121/1.399052
- Grossöhmichen, M., Salcher, R., Lenarz, T., & Maier, H. (2016). The Effect of Simulated Mastoid Obliteration on the Mechanical Output of Electromagnetic Transducers. Otology & Neurotology, 37(7), 919–925. https://doi.org/10.1097/mao.0000000000001062
- Gundersen, T., Skarstein, . øyvin ., & Sikkeland, T. (1978). A Study of the Vibration of the Basilar Membrane in Human Temporal Bone Preparations by the Use of the Mossbauer Effect. Acta Oto-Laryngologica, 86(1-6), 225–232. https://doi.org/10.3109/00016487809124740
- Heeren, W., Hohmann, V., Appell, J. E., & Verhey, J. L. (2013). Relation between loudness in categorical units and loudness in phons and sones. The Journal of the Acoustical Society of America, 133(4), EL314–EL319. https://doi.org/10.1121/1.4795217
- Holube, I., Fredelake, S., Vlaming, M., & Kollmeier, B. (2010). Development and analysis of an International Speech Test Signal (ISTS). International Journal of Audiology, 49(12), 891–903. https://doi.org/10.3109/14992027.2010.506889
- ISO 389-7, 2019. Acoustics — Reference zero for the calibration of audiometric equipment— Part 7: Reference threshold of hearing under free-field and diffuse-field listening conditions. International Organization for Standardization, Geneva.
- Johnstone, B. M., Patuzzi, R., & Yates, G. K. (1986). Basilar membrane measurements and the travelling wave. Hearing Research, 22(1-3), 147–153. https://doi.org/10.1016/0378-5955(86)90090-0
- Kim, H. H., & Barrs, D. M. (2006). Hearing Aids: A Review of What's New. Otolaryngology–Head and Neck Surgery, 134(6), 1043–1050. https://doi.org/10.1016/j.otohns.2006.03.010
- Koch, M., Eßinger, T. M., Maier, H., Sim, J. H., Ren, L., Greene, N. T., Zahnert, T., Neudert, M., & Bornitz, M. (2022). Methods and reference data for middle ear transfer functions. Scientific Reports, 12(1). https://doi.org/10.1038/s41598-022-21245-w
- Noise-induced hearing losses. Can they be explained by basilar membrane movement?
- Liu, H., Liu, Z., Liu, J., Lenarz, T., & Maier, H. (2025). Effect of electromagnetic transducer design parameters on round-window stimulation in otosclerosis: a nonlinear dynamic analysis. Nonlinear Dynamics, 113(14), 18727–18744. https://doi.org/10.1007/s11071-025-11149-5
- Liu, H., Xue, L., Yang, J., Liu, W., Yang, S., & Wang, W. (2020). Modeling the effect of cochlear windows activity on reverse stimulation under the role of physiological third windows. Applied Acoustics, 169, 107473. https://doi.org/10.1016/j.apacoust.2020.107473
- Liu, Z., Liu, H., Guo, W., Chen, W., Liu, W., & Yang, S. (2025). Mechanical stimulation of cochlea for treatment of hearing loss: Comparison between forward stimulation and reverse stimulation with an active cochlear model. Computer Methods and Programs in Biomedicine, 264, Article 108721. https://doi.org/10.1016/j.cmpb.2025.108721
- Consensus Statement on Bone Conduction Devices and Active Middle Ear Implants in Conductive and Mixed Hearing Loss. (2022). Consensus Statement on Bone Conduction Devices and Active Middle Ear Implants in Conductive and Mixed Hearing Loss. Otology & Neurotology, 43(5), 513–529. https://doi.org/10.1097/mao.0000000000003491
- Development and current status of the "Cambridge" loudness models
- A revision of Zwicker's loudness model