Published January 2011 | Journal article | Version v1 | https://doi.org/10.1186/1532-429x-13-71

Impact of an abdominal belt on breathing patterns and scan efficiency in whole-heart coronary magnetic resonance angiography: comparison between the UK and Japan

Additional details

Funding

ROR icon British Heart Foundation
RE/08/003
ROR icon National Institute for Health and Care Research
BRC-CTF 196
ROR icon British Heart Foundation
True validation of quantitative myocardial perfusion magnetic resonance imaging FS/10/029/28253
ROR icon Bayer (Germany)
ROR icon Philips (United States)

Dates

Issued
January 2011

References

  1. MEMBERS, W. G., Lloyd-Jones, D., Adams, R., Carnethon, M., De Simone, G., Ferguson, T. B., Flegal, K., Ford, E., Furie, K., Go, A., Greenlund, K., Haase, N., Hailpern, S., Ho, M., Howard, V., Kissela, B., Kittner, S., Lackland, D., Lisabeth, L., … Hong, Y. (2009). Heart Disease and Stroke Statistics—2009 Update. Circulation, 119(3), 480–486. https://doi.org/10.1161/circulationaha.108.191259
  2. Edelman, R. R., Manning, W. J., Burstein, D., & Paulin, S. (1991). Coronary arteries: breath-hold MR angiography. Radiology, 181(3), 641–643. https://doi.org/10.1148/radiology.181.3.1947074
  3. Manning, W. J., Li, W., & Edelman, R. R. (1993). A Preliminary Report Comparing Magnetic Resonance Coronary Angiography with Conventional Angiography. New England Journal of Medicine, 328(12), 828–832. https://doi.org/10.1056/nejm199303253281202
  4. Kim, W. Y., Danias, P. G., Stuber, M., Flamm, S. D., Plein, S., Nagel, E., Langerak, S. E., Weber, O. M., Pedersen, E. M., Schmidt, M., Botnar, R. M., & Manning, W. J. (2001). Coronary Magnetic Resonance Angiography for the Detection of Coronary Stenoses. New England Journal of Medicine, 345(26), 1863–1869. https://doi.org/10.1056/nejmoa010866
  5. Stuber, M., & Weiss, R. G. (2007). Coronary magnetic resonance angiography. Journal of Magnetic Resonance Imaging, 26(2), 219–234. https://doi.org/10.1002/jmri.20949
  6. Weber, O. M., Martin, A. J., & Higgins, C. B. (2003). Whole‐heart steady‐state free precession coronary artery magnetic resonance angiography. Magnetic Resonance in Medicine, 50(6), 1223–1228. https://doi.org/10.1002/mrm.10653
  7. Sakuma, H., Ichikawa, Y., Suzawa, N., Hirano, T., Makino, K., Koyama, N., Van Cauteren, M., & Takeda, K. (2005). Assessment of Coronary Arteries with Total Study Time of Less than 30 Minutes by Using Whole-Heart Coronary MR Angiography. Radiology, 237(1), 316–321. https://doi.org/10.1148/radiol.2371040830
  8. Jahnke, C., Paetsch, I., Nehrke, K., Schnackenburg, B., Gebker, R., Fleck, E., & Nagel, E. (2005). Rapid and complete coronary arterial tree visualization with magnetic resonance imaging: feasibility and diagnostic performance. European Heart Journal, 26(21), 2313–2319. https://doi.org/10.1093/eurheartj/ehi391
  9. Sakuma, H., Ichikawa, Y., Chino, S., Hirano, T., Makino, K., & Takeda, K. (2006). Detection of Coronary Artery Stenosis With Whole-Heart Coronary Magnetic Resonance Angiography. Journal of the American College of Cardiology, 48(10), 1946–1950. https://doi.org/10.1016/j.jacc.2006.07.055
  10. Kato, S., Kitagawa, K., Ishida, N., Ishida, M., Nagata, M., Ichikawa, Y., Katahira, K., Matsumoto, Y., Seo, K., Ochiai, R., Kobayashi, Y., & Sakuma, H. (2010). Assessment of Coronary Artery Disease Using Magnetic Resonance Coronary Angiography. Journal of the American College of Cardiology, 56(12), 983–991. https://doi.org/10.1016/j.jacc.2010.01.071
  11. Nagel, E. (2010). Magnetic Resonance Coronary Angiography. Journal of the American College of Cardiology, 56(12), 992–994. https://doi.org/10.1016/j.jacc.2010.02.069
  12. Taylor, A. M., Jhooti, P., Firmin, D. N., & Pennell, D. J. (1999). Automated monitoring of diaphragm end-expiratory position for real-time navigator echo MR coronary angiography. Journal of Magnetic Resonance Imaging, 9(3), 395–401. https://doi.org/10.1002/(sici)1522-2586(199903)9:3%3C395::aid-jmri6%3E3.0.co;2-y
  13. Wintersperger, B. J., Reeder, S. B., Nikolaou, K., Dietrich, O., Huber, A., Greiser, A., Lanz, T., Reiser, M. F., & Schoenberg, S. O. (2005). Cardiac CINE MR imaging with a 32‐channel cardiac coil and parallel imaging: Impact of acceleration factors on image quality and volumetric accuracy. Journal of Magnetic Resonance Imaging, 23(2), 222–227. https://doi.org/10.1002/jmri.20484
  14. International comparisons of obesity prevalence. National Obesity Observatory. NHS. 2011, [
  15. The impact of different positions and thoracial restrains of respiratory induced cardiac motion
  16. Nagata, M., Kato, S., Kitagawa, K., Ishida, N., Nakajima, H., Nakamori, S., Ishida, M., Miyahara, M., Ito, M., & Sakuma, H. (2011). Diagnostic Accuracy of 1.5-T Unenhanced Whole-Heart Coronary MR Angiography Performed with 32-Channel Cardiac Coils: Initial Single-Center Experience. Radiology, 259(2), 384–392. https://doi.org/10.1148/radiol.11101323
  17. MORITA, S., SUZUKI, K., MACHIDA, H., FUJIMURA, M., OHNISHI, T., IMURA, C., & UENO, E. (2008). Compression Belt for Navigator-triggered trueFISP Whole-heart Coronary Magnetic Resonance Angiography: Study in Healthy Volunteers. Magnetic Resonance in Medical Sciences, 7(2), 79–83. https://doi.org/10.2463/mrms.7.79
  18. Danias, P. G., Stuber, M., Botnar, R. M., Kissinger, K. V., Edelman, R. R., & Manning, W. J. (1999). Relationship between motion of coronary arteries and diaphragm during free breathing: lessons from real-time MR imaging. American Journal of Roentgenology, 172(4), 1061–1065. https://doi.org/10.2214/ajr.172.4.10587147

Citations

  1. Aronis, G., Kurz, M., Angeli, T., & Gföhler, M. (2026). Development and EMG/metabolic assessment of a passive shoulder exoskeleton providing adjustable support for high arm elevation. Applied Ergonomics, 132, 104681. https://doi.org/10.1016/j.apergo.2025.104681
  2. https://doi.org/10.6009/jjrt.26-1618
  3. Sang, Y., Li, S., Wang, H., Zhang, H., Zhuang, B., & Xu, L. (2025). Noninvasive coronary imaging: Technological breakthroughs and the integrated application of coronary magnetic resonance angiography. International Journal of Cardiology Cardiovascular Risk and Prevention, 27, 200542. https://doi.org/10.1016/j.ijcrp.2025.200542
  4. Takafuji, M., Ishida, M., Shiomi, T., Nakayama, R., Fujita, M., Yamaguchi, S., Washiyama, Y., Nagata, M., Ichikawa, Y., Inoue, K., Nakamura, S., & Sakuma, H. (2025). Development of a deep learning algorithm for detecting significant coronary artery stenosis in whole-heart coronary magnetic resonance angiography. Journal of Cardiovascular Magnetic Resonance, 27(2), 101932. https://doi.org/10.1016/j.jocmr.2025.101932
  5. Yu, A., Gao, H., Ma, Y., Li, J., & Zhang, H. (2024). Feasibility study of the multishot gradient-echo planar imaging sequence in non-enhanced and free-breathing whole-heart magnetic resonance coronary angiography. Clinical Radiology, 79(4), e539–e545. https://doi.org/10.1016/j.crad.2023.12.006
  6. https://doi.org/10.7759/cureus.60656
  7. Munoz, C., Fotaki, A., Hua, A., Hajhosseiny, R., Kunze, K. P., Ismail, T. F., Neji, R., Pushparajah, K., Botnar, R. M., & Prieto, C. (2023). Simultaneous Highly Efficient Contrast‐Free Lumen and Vessel Wall MR Imaging for Anatomical Assessment of Aortic Disease. Journal of Magnetic Resonance Imaging, 58(4), 1110–1122. https://doi.org/10.1002/jmri.28613
  8. Crean, A. (2023). Coronary Artery Anomalies. In Magnetic Resonance Imaging of Congenital Heart Disease (pp. 273–302). Springer International Publishing. https://doi.org/10.1007/978-3-031-29235-4_16
  9. Wu, X., Tang, L., Li, W., He, S., Yue, X., Peng, P., Wu, T., Zhang, X., Wu, Z., He, Y., Chen, Y., Huang, J., & Sun, J. (2023). Feasibility of accelerated non-contrast-enhanced whole-heart bSSFP coronary MR angiography by deep learning–constrained compressed sensing. European Radiology, 33(11), 8180–8190. https://doi.org/10.1007/s00330-023-09740-8
  10. https://doi.org/10.6009/jjrt.2023-2182
  11. Heerfordt, J., Whitehead, K. K., Bastiaansen, J. A. M., Di Sopra, L., Roy, C. W., Yerly, J., Milani, B., Fogel, M. A., Stuber, M., & Piccini, D. (2021). Similarity‐driven multi‐dimensional binning algorithm (SIMBA) for free‐running motion‐suppressed whole‐heart MRA. Magnetic Resonance in Medicine, 86(1), 213–229. https://doi.org/10.1002/mrm.28713
  12. Smith, L. R., Darty, S. N., Jenista, E. R., Gamoneda, G. L., Wendell, D. C., Azevedo, C. F., Parker, M. A., Kim, R. J., & Kim, H. W. (2021). ECG-gated MR angiography provides better reproducibility for standard aortic measurements. European Radiology, 31(7), 5087–5095. https://doi.org/10.1007/s00330-020-07408-1
  13. Craft, J., Li, Y., Bhatti, S., & Cao, J. J. (2021). How to do left atrial late gadolinium enhancement: a review. La Radiologia Medica, 126(9), 1159–1169. https://doi.org/10.1007/s11547-021-01383-3
  14. Bazot, M., Kermarrec, E., Bendifallah, S., & Daraï, E. (2021). MRI of intestinal endometriosis. Best Practice & Research Clinical Obstetrics & Gynaecology, 71, 51–63. https://doi.org/10.1016/j.bpobgyn.2020.05.013
  15. https://doi.org/10.1186/s12968-020-0601-0
  16. https://doi.org/10.1259/bjr.20200690
  17. Heerfordt, J., Stuber, M., Maillot, A., Bianchi, V., & Piccini, D. (2019). A quantitative comparison between a navigated Cartesian and a self‐navigated radial protocol from clinical studies for free‐breathing 3D whole‐heart bSSFP coronary MRA. Magnetic Resonance in Medicine, 84(1), 157–169. https://doi.org/10.1002/mrm.28101
  18. Ishida, M., & Sakuma, H. (2019). Coronary Magnetic Resonance Angiography: Techniques and Clinical Results. In Contemporary Cardiology (pp. 205–227). Springer New York. https://doi.org/10.1007/978-1-4939-8841-9_13
  19. Takahashi, J., Ohmoto-Sekine, Y., Yoshida, T., & Miyazaki, M. (2019). Comparison of axial and coronal acquisitions by non-contrast-enhanced renal 3D MR angiography using flow-in time-spatial labeling inversion pulse. Magnetic Resonance Materials in Physics, Biology and Medicine, 33(1), 95–102. https://doi.org/10.1007/s10334-019-00796-6
  20. Cavedon, C. (2019). Real-time control of respiratory motion: Beyond radiation therapy. Physica Medica, 66, 104–112. https://doi.org/10.1016/j.ejmp.2019.09.241
  21. Ichikawa, Y., Tomita, Y., Ishida, M., Kobayashi, S., Takeda, K., & Sakuma, H. (2018). Usefulness of abdominal belt for restricting respiratory cardiac motion and improving image quality in myocardial perfusion PET. Journal of Nuclear Cardiology, 25(2), 407–415. https://doi.org/10.1007/s12350-016-0623-z
  22. Bazot, M., Bharwani, N., Huchon, C., Kinkel-Trugli, K., Cunha, T. M., Guerra, A., Manganaro, L., Bunesch, L., Kido, A., Togashi, K., Thomassin-Naggara, I., & Rockall, A. (2017). Recommandations de la Société européenne d’imagerie génito-urinaire : IRM de l’endométriose pelvienne. Imagerie de la Femme, 27(4), 267–279. https://doi.org/10.1016/j.femme.2017.09.007
  23. https://doi.org/10.1097/rli.0000000000000321
  24. https://doi.org/10.22468/cvia.2016.00066
  25. Bazot, M., Bharwani, N., Huchon, C., Kinkel, K., Cunha, T. M., Guerra, A., Manganaro, L., Buñesch, L., Kido, A., Togashi, K., Thomassin-Naggara, I., & Rockall, A. G. (2016). European society of urogenital radiology (ESUR) guidelines: MR imaging of pelvic endometriosis. European Radiology, 27(7), 2765–2775. https://doi.org/10.1007/s00330-016-4673-z

1–25 of 38