Impact of an abdominal belt on breathing patterns and scan efficiency in whole-heart coronary magnetic resonance angiography: comparison between the UK and Japan
Authors/Creators
- Ishida, Masaki1, 2, 3, 4, 5, 6, 7, 8
- Schuster, Andreas1, 2, 3, 4, 5, 6, 7, 8
- Takase, Shinichi9
- Morton, Geraint1, 2, 3, 4, 5, 6, 7, 8
- Chiribiri, Amedeo1, 2, 3, 4, 5, 6, 7, 8
- Bigalke, Boris1, 2, 3, 4, 5, 6, 7, 8
- Schaeffter, Tobias1, 2, 3, 4, 5, 6, 7, 8
- Sakuma, Hajime9
- Nagel, Eike1, 2, 3, 4, 5, 6, 7, 8
-
1.
Engineering and Physical Sciences Research Council
-
2.
St Thomas' Hospital
-
3.
King's College London
-
4.
Guy's and St Thomas' NHS Foundation Trust
-
5.
British Heart Foundation
-
6.
National Institute for Health and Care Research
-
7.
Wellcome EPSRC Centre for Medical Engineering
-
8.
Wellcome Trust
-
9.
Mie University Hospital
Additional details
Identifiers
Funding
-
British Heart Foundation
- RE/08/003
-
National Institute for Health and Care Research
- BRC-CTF 196
-
British Heart Foundation
- True validation of quantitative myocardial perfusion magnetic resonance imaging FS/10/029/28253
-
Bayer (Germany)
-
Philips (United States)
Dates
- Issued
-
January 2011
References
- MEMBERS, W. G., Lloyd-Jones, D., Adams, R., Carnethon, M., De Simone, G., Ferguson, T. B., Flegal, K., Ford, E., Furie, K., Go, A., Greenlund, K., Haase, N., Hailpern, S., Ho, M., Howard, V., Kissela, B., Kittner, S., Lackland, D., Lisabeth, L., … Hong, Y. (2009). Heart Disease and Stroke Statistics—2009 Update. Circulation, 119(3), 480–486. https://doi.org/10.1161/circulationaha.108.191259
- Edelman, R. R., Manning, W. J., Burstein, D., & Paulin, S. (1991). Coronary arteries: breath-hold MR angiography. Radiology, 181(3), 641–643. https://doi.org/10.1148/radiology.181.3.1947074
- Manning, W. J., Li, W., & Edelman, R. R. (1993). A Preliminary Report Comparing Magnetic Resonance Coronary Angiography with Conventional Angiography. New England Journal of Medicine, 328(12), 828–832. https://doi.org/10.1056/nejm199303253281202
- Kim, W. Y., Danias, P. G., Stuber, M., Flamm, S. D., Plein, S., Nagel, E., Langerak, S. E., Weber, O. M., Pedersen, E. M., Schmidt, M., Botnar, R. M., & Manning, W. J. (2001). Coronary Magnetic Resonance Angiography for the Detection of Coronary Stenoses. New England Journal of Medicine, 345(26), 1863–1869. https://doi.org/10.1056/nejmoa010866
- Stuber, M., & Weiss, R. G. (2007). Coronary magnetic resonance angiography. Journal of Magnetic Resonance Imaging, 26(2), 219–234. https://doi.org/10.1002/jmri.20949
- Weber, O. M., Martin, A. J., & Higgins, C. B. (2003). Whole‐heart steady‐state free precession coronary artery magnetic resonance angiography. Magnetic Resonance in Medicine, 50(6), 1223–1228. https://doi.org/10.1002/mrm.10653
- Sakuma, H., Ichikawa, Y., Suzawa, N., Hirano, T., Makino, K., Koyama, N., Van Cauteren, M., & Takeda, K. (2005). Assessment of Coronary Arteries with Total Study Time of Less than 30 Minutes by Using Whole-Heart Coronary MR Angiography. Radiology, 237(1), 316–321. https://doi.org/10.1148/radiol.2371040830
- Jahnke, C., Paetsch, I., Nehrke, K., Schnackenburg, B., Gebker, R., Fleck, E., & Nagel, E. (2005). Rapid and complete coronary arterial tree visualization with magnetic resonance imaging: feasibility and diagnostic performance. European Heart Journal, 26(21), 2313–2319. https://doi.org/10.1093/eurheartj/ehi391
- Sakuma, H., Ichikawa, Y., Chino, S., Hirano, T., Makino, K., & Takeda, K. (2006). Detection of Coronary Artery Stenosis With Whole-Heart Coronary Magnetic Resonance Angiography. Journal of the American College of Cardiology, 48(10), 1946–1950. https://doi.org/10.1016/j.jacc.2006.07.055
- Kato, S., Kitagawa, K., Ishida, N., Ishida, M., Nagata, M., Ichikawa, Y., Katahira, K., Matsumoto, Y., Seo, K., Ochiai, R., Kobayashi, Y., & Sakuma, H. (2010). Assessment of Coronary Artery Disease Using Magnetic Resonance Coronary Angiography. Journal of the American College of Cardiology, 56(12), 983–991. https://doi.org/10.1016/j.jacc.2010.01.071
- Nagel, E. (2010). Magnetic Resonance Coronary Angiography. Journal of the American College of Cardiology, 56(12), 992–994. https://doi.org/10.1016/j.jacc.2010.02.069
- Taylor, A. M., Jhooti, P., Firmin, D. N., & Pennell, D. J. (1999). Automated monitoring of diaphragm end-expiratory position for real-time navigator echo MR coronary angiography. Journal of Magnetic Resonance Imaging, 9(3), 395–401. https://doi.org/10.1002/(sici)1522-2586(199903)9:3%3C395::aid-jmri6%3E3.0.co;2-y
- Wintersperger, B. J., Reeder, S. B., Nikolaou, K., Dietrich, O., Huber, A., Greiser, A., Lanz, T., Reiser, M. F., & Schoenberg, S. O. (2005). Cardiac CINE MR imaging with a 32‐channel cardiac coil and parallel imaging: Impact of acceleration factors on image quality and volumetric accuracy. Journal of Magnetic Resonance Imaging, 23(2), 222–227. https://doi.org/10.1002/jmri.20484
- International comparisons of obesity prevalence. National Obesity Observatory. NHS. 2011, [
- The impact of different positions and thoracial restrains of respiratory induced cardiac motion
- Nagata, M., Kato, S., Kitagawa, K., Ishida, N., Nakajima, H., Nakamori, S., Ishida, M., Miyahara, M., Ito, M., & Sakuma, H. (2011). Diagnostic Accuracy of 1.5-T Unenhanced Whole-Heart Coronary MR Angiography Performed with 32-Channel Cardiac Coils: Initial Single-Center Experience. Radiology, 259(2), 384–392. https://doi.org/10.1148/radiol.11101323
- MORITA, S., SUZUKI, K., MACHIDA, H., FUJIMURA, M., OHNISHI, T., IMURA, C., & UENO, E. (2008). Compression Belt for Navigator-triggered trueFISP Whole-heart Coronary Magnetic Resonance Angiography: Study in Healthy Volunteers. Magnetic Resonance in Medical Sciences, 7(2), 79–83. https://doi.org/10.2463/mrms.7.79
- Danias, P. G., Stuber, M., Botnar, R. M., Kissinger, K. V., Edelman, R. R., & Manning, W. J. (1999). Relationship between motion of coronary arteries and diaphragm during free breathing: lessons from real-time MR imaging. American Journal of Roentgenology, 172(4), 1061–1065. https://doi.org/10.2214/ajr.172.4.10587147
Citations
- Aronis, G., Kurz, M., Angeli, T., & Gföhler, M. (2026). Development and EMG/metabolic assessment of a passive shoulder exoskeleton providing adjustable support for high arm elevation. Applied Ergonomics, 132, 104681. https://doi.org/10.1016/j.apergo.2025.104681
- https://doi.org/10.6009/jjrt.26-1618
- Sang, Y., Li, S., Wang, H., Zhang, H., Zhuang, B., & Xu, L. (2025). Noninvasive coronary imaging: Technological breakthroughs and the integrated application of coronary magnetic resonance angiography. International Journal of Cardiology Cardiovascular Risk and Prevention, 27, 200542. https://doi.org/10.1016/j.ijcrp.2025.200542
- Takafuji, M., Ishida, M., Shiomi, T., Nakayama, R., Fujita, M., Yamaguchi, S., Washiyama, Y., Nagata, M., Ichikawa, Y., Inoue, K., Nakamura, S., & Sakuma, H. (2025). Development of a deep learning algorithm for detecting significant coronary artery stenosis in whole-heart coronary magnetic resonance angiography. Journal of Cardiovascular Magnetic Resonance, 27(2), 101932. https://doi.org/10.1016/j.jocmr.2025.101932
- Yu, A., Gao, H., Ma, Y., Li, J., & Zhang, H. (2024). Feasibility study of the multishot gradient-echo planar imaging sequence in non-enhanced and free-breathing whole-heart magnetic resonance coronary angiography. Clinical Radiology, 79(4), e539–e545. https://doi.org/10.1016/j.crad.2023.12.006
- https://doi.org/10.7759/cureus.60656
- Munoz, C., Fotaki, A., Hua, A., Hajhosseiny, R., Kunze, K. P., Ismail, T. F., Neji, R., Pushparajah, K., Botnar, R. M., & Prieto, C. (2023). Simultaneous Highly Efficient Contrast‐Free Lumen and Vessel Wall MR Imaging for Anatomical Assessment of Aortic Disease. Journal of Magnetic Resonance Imaging, 58(4), 1110–1122. https://doi.org/10.1002/jmri.28613
- Crean, A. (2023). Coronary Artery Anomalies. In Magnetic Resonance Imaging of Congenital Heart Disease (pp. 273–302). Springer International Publishing. https://doi.org/10.1007/978-3-031-29235-4_16
- Wu, X., Tang, L., Li, W., He, S., Yue, X., Peng, P., Wu, T., Zhang, X., Wu, Z., He, Y., Chen, Y., Huang, J., & Sun, J. (2023). Feasibility of accelerated non-contrast-enhanced whole-heart bSSFP coronary MR angiography by deep learning–constrained compressed sensing. European Radiology, 33(11), 8180–8190. https://doi.org/10.1007/s00330-023-09740-8
- https://doi.org/10.6009/jjrt.2023-2182
- Heerfordt, J., Whitehead, K. K., Bastiaansen, J. A. M., Di Sopra, L., Roy, C. W., Yerly, J., Milani, B., Fogel, M. A., Stuber, M., & Piccini, D. (2021). Similarity‐driven multi‐dimensional binning algorithm (SIMBA) for free‐running motion‐suppressed whole‐heart MRA. Magnetic Resonance in Medicine, 86(1), 213–229. https://doi.org/10.1002/mrm.28713
- Smith, L. R., Darty, S. N., Jenista, E. R., Gamoneda, G. L., Wendell, D. C., Azevedo, C. F., Parker, M. A., Kim, R. J., & Kim, H. W. (2021). ECG-gated MR angiography provides better reproducibility for standard aortic measurements. European Radiology, 31(7), 5087–5095. https://doi.org/10.1007/s00330-020-07408-1
- Craft, J., Li, Y., Bhatti, S., & Cao, J. J. (2021). How to do left atrial late gadolinium enhancement: a review. La Radiologia Medica, 126(9), 1159–1169. https://doi.org/10.1007/s11547-021-01383-3
- Bazot, M., Kermarrec, E., Bendifallah, S., & Daraï, E. (2021). MRI of intestinal endometriosis. Best Practice & Research Clinical Obstetrics & Gynaecology, 71, 51–63. https://doi.org/10.1016/j.bpobgyn.2020.05.013
- https://doi.org/10.1186/s12968-020-0601-0
- https://doi.org/10.1259/bjr.20200690
- Heerfordt, J., Stuber, M., Maillot, A., Bianchi, V., & Piccini, D. (2019). A quantitative comparison between a navigated Cartesian and a self‐navigated radial protocol from clinical studies for free‐breathing 3D whole‐heart bSSFP coronary MRA. Magnetic Resonance in Medicine, 84(1), 157–169. https://doi.org/10.1002/mrm.28101
- Ishida, M., & Sakuma, H. (2019). Coronary Magnetic Resonance Angiography: Techniques and Clinical Results. In Contemporary Cardiology (pp. 205–227). Springer New York. https://doi.org/10.1007/978-1-4939-8841-9_13
- Takahashi, J., Ohmoto-Sekine, Y., Yoshida, T., & Miyazaki, M. (2019). Comparison of axial and coronal acquisitions by non-contrast-enhanced renal 3D MR angiography using flow-in time-spatial labeling inversion pulse. Magnetic Resonance Materials in Physics, Biology and Medicine, 33(1), 95–102. https://doi.org/10.1007/s10334-019-00796-6
- Cavedon, C. (2019). Real-time control of respiratory motion: Beyond radiation therapy. Physica Medica, 66, 104–112. https://doi.org/10.1016/j.ejmp.2019.09.241
- Ichikawa, Y., Tomita, Y., Ishida, M., Kobayashi, S., Takeda, K., & Sakuma, H. (2018). Usefulness of abdominal belt for restricting respiratory cardiac motion and improving image quality in myocardial perfusion PET. Journal of Nuclear Cardiology, 25(2), 407–415. https://doi.org/10.1007/s12350-016-0623-z
- Bazot, M., Bharwani, N., Huchon, C., Kinkel-Trugli, K., Cunha, T. M., Guerra, A., Manganaro, L., Bunesch, L., Kido, A., Togashi, K., Thomassin-Naggara, I., & Rockall, A. (2017). Recommandations de la Société européenne d’imagerie génito-urinaire : IRM de l’endométriose pelvienne. Imagerie de la Femme, 27(4), 267–279. https://doi.org/10.1016/j.femme.2017.09.007
- https://doi.org/10.1097/rli.0000000000000321
- https://doi.org/10.22468/cvia.2016.00066
- Bazot, M., Bharwani, N., Huchon, C., Kinkel, K., Cunha, T. M., Guerra, A., Manganaro, L., Buñesch, L., Kido, A., Togashi, K., Thomassin-Naggara, I., & Rockall, A. G. (2016). European society of urogenital radiology (ESUR) guidelines: MR imaging of pelvic endometriosis. European Radiology, 27(7), 2765–2775. https://doi.org/10.1007/s00330-016-4673-z
1–25 of 38