Delayed Improvement of Left Ventricular Function in Newly Diagnosed Heart Failure Depends on Etiology—A PROLONG-II Substudy
Description
In patients with newly diagnosed heart failure with reduced ejection fraction (HFrEF), three months of optimal therapy are recommended before considering a primary preventive implantable cardioverter-defibrillator (ICD). It is unclear which patients benefit from a prolonged waiting period under protection of the wearable cardioverter-defibrillator (WCD) to avoid unnecessary ICD implantations. This study included all patients receiving a WCD for newly diagnosed HFrEF (n = 353) at our center between 2012 and 2017. Median follow-up was 2.7 years. From baseline until three months, LVEF improved in patients with all peripartum cardiomyopathy (PPCM), myocarditis, dilated cardiomyopathy (DCM), or ischemic cardiomyopathy (ICM). Beyond this time, LVEF improved in PPCM and DCM only (10 ± 8% and 10 ± 12%, respectively), whereas patients with ICM showed no further improvement. The patients with newly diagnosed HFrEF were compared to 29 patients with a distinct WCD indication, which is an explantation of an infected ICD. This latter group had a higher incidence of WCD shocks and poorer overall survival. All-cause mortality should be considered when deciding on WCD prescription. In patients with newly diagnosed HFrEF, the potential for delayed LVEF recovery should be considered when timing ICD implantation, especially in patients with PPCM and DCM.
Additional details
Identifiers
- OpenAlex
- W4220860088
- PMID
- 35271182
- URL
- https://www.mdpi.com/1424-8220/22/5/2037
Dates
- Issued
-
March 5, 2022
References
- Mehta, P. A., Dubrey, S. W., McIntyre, H. F., Walker, D. M., Hardman, S. M. C., Sutton, G. C., McDonagh, T. A., & Cowie, M. R. (2008). Mode of Death in Patients with Newly Diagnosed Heart Failure in the General Population. European Journal of Heart Failure, 10(11), 1108–1116. https://doi.org/10.1016/j.ejheart.2008.09.004
- Duncker, D., König, T., Hohmann, S., Bauersachs, J., & Veltmann, C. (2017). Ventricular arrhythmias in patients with newly diagnosed nonischemic cardiomyopathy: Insights from the PROLONG study. Clinical Cardiology, 40(8), 586–590. https://doi.org/10.1002/clc.22706
- PICCINI, J. P., AL‐KHATIB, S. M., MYERS, E. R., ANSTROM, K. J., BUXTON, A. E., PETERSON, E. D., & SANDERS, G. D. (2010). Optimal Timing of Implantable Cardioverter‐Defibrillator Implantation After Myocardial Infarction: A Decision Analysis. Journal of Cardiovascular Electrophysiology, 21(7), 791–798. https://doi.org/10.1111/j.1540-8167.2009.01696.x
- Makati, K. J., Fish, A. E., England, H. H., Tighiouart, H., Estes, N. A. M., & Link, M. S. (2006). Equivalent arrhythmic risk in patients recently diagnosed with dilated cardiomyopathy compared with patients diagnosed for 9 months or more. Heart Rhythm, 3(4), 397–403. https://doi.org/10.1016/j.hrthm.2006.01.012
- McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., Chioncel, O., Cleland, J. G. F., Coats, A. J. S., Crespo-Leiro, M. G., Farmakis, D., Gilard, M., Heymans, S., Hoes, A. W., Jaarsma, T., Jankowska, E. A., … Skibelund, A. K. (2021). 2021 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure. European Heart Journal, 42(36), 3599–3726. https://doi.org/10.1093/eurheartj/ehab368
- Taylor, C. J., Ordóñez-Mena, J. M., Roalfe, A. K., Lay-Flurrie, S., Jones, N. R., Marshall, T., & Hobbs, F. D. R. (2019). Trends in survival after a diagnosis of heart failure in the United Kingdom 2000-2017: population based cohort study. BMJ, l223. https://doi.org/10.1136/bmj.l223
- Moliner, P., Lupón, J., de Antonio, M., Domingo, M., Santiago-Vacas, E., Zamora, E., Cediel, G., Santesmases, J., Díez-Quevedo, C., Troya, M. I., Boldó, M., Altmir, S., Alonso, N., González, B., Núñez, J., & Bayes-Genis, A. (2019). Trends in Modes of Death in Heart Failure Over the Last Two Decades: Less Sudden Death but Cancer Deaths on the Rise. European Journal of Heart Failure, 21(10), 1259–1266. https://doi.org/10.1002/ejhf.1569
- Shen, L., Jhund, P. S., Petrie, M. C., Claggett, B. L., Barlera, S., Cleland, J. G. F., Dargie, H. J., Granger, C. B., Kjekshus, J., Køber, L., Latini, R., Maggioni, A. P., Packer, M., Pitt, B., Solomon, S. D., Swedberg, K., Tavazzi, L., Wikstrand, J., Zannad, F., … McMurray, J. J. V. (2017). Declining Risk of Sudden Death in Heart Failure. New England Journal of Medicine, 377(1), 41–51. https://doi.org/10.1056/nejmoa1609758
- Hawkins, N. M., Grubisic, M., Andrade, J. G., Huang, F., Ding, L., Gao, M., & Bashir, J. (2017). Long-term complications, reoperations and survival following cardioverter-defibrillator implant. Heart, 104(3), 237–243. https://doi.org/10.1136/heartjnl-2017-311638
- Ezzat, V. A., Lee, V., Ahsan, S., Chow, A. W., Segal, O., Rowland, E., Lowe, M. D., & Lambiase, P. D. (2015). A systematic review of ICD complications in randomised controlled trials versus registries: is our 'real-world' data an underestimation?. Open Heart, 2(1), e000198. https://doi.org/10.1136/openhrt-2014-000198
- Koneru, J. N., Jones, P. W., Hammill, E. F., Wold, N., & Ellenbogen, K. A. (2018). Risk Factors and Temporal Trends of Complications Associated With Transvenous Implantable Cardiac Defibrillator Leads. Journal of the American Heart Association, 7(10). https://doi.org/10.1161/jaha.117.007691
- Al-Khatib, S. M. (2011). Non–Evidence-Based ICD Implantations in the United States. JAMA, 305(1), 43. https://doi.org/10.1001/jama.2010.1915
- Duncker, D., König, T., Hohmann, S., Bauersachs, J., & Veltmann, C. (2017). Avoiding Untimely Implantable Cardioverter/Defibrillator Implantation by Intensified Heart Failure Therapy Optimization Supported by the Wearable Cardioverter/Defibrillator—The PROLONG Study. Journal of the American Heart Association, 6(1). https://doi.org/10.1161/jaha.116.004512
- DeFilippis, E. M., Butler, J., & Vaduganathan, M. (2017). Waiting Period Before Implantable Cardioverter-Defibrillator Implantation in Newly Diagnosed Heart Failure With Reduced Ejection Fraction. Circulation: Heart Failure, 10(11). https://doi.org/10.1161/circheartfailure.117.004478
- Wong, J. A., Roberts, J. D., & Healey, J. S. (2021). The Optimal Timing of Primary Prevention Implantable Cardioverter-Defibrillator Referral in the Rapidly Changing Medical Landscape. Canadian Journal of Cardiology, 37(4), 644–654. https://doi.org/10.1016/j.cjca.2021.01.024
- Goldberger, J. J., Subačius, H., Patel, T., Cunnane, R., & Kadish, A. H. (2014). Sudden Cardiac Death Risk Stratification in Patients With Nonischemic Dilated Cardiomyopathy. Journal of the American College of Cardiology, 63(18), 1879–1889. https://doi.org/10.1016/j.jacc.2013.12.021
- Duncker, D., & Veltmann, C. (2018). Role of the Wearable Defibrillator in Newly Diagnosed Heart Failure. Current Heart Failure Reports, 15(6), 368–375. https://doi.org/10.1007/s11897-018-0415-7
- Duncker, D., and Veltmann, C. (2016). The Wearable Cardioverter/Defibrillator—Toy or Tool?. J. Atr. Fibrillation, 8.
- Duncker, D., & Veltmann, C. (2018). Defibrillatorweste: Aktueller Stand. Herzschrittmachertherapie + Elektrophysiologie, 29(4), 362–368. https://doi.org/10.1007/s00399-018-0601-z
- Olgin, J. E., Pletcher, M. J., Vittinghoff, E., Wranicz, J., Malik, R., Morin, D. P., Zweibel, S., Buxton, A. E., Elayi, C. S., Chung, E. H., Rashba, E., Borggrefe, M., Hue, T. F., Maguire, C., Lin, F., Simon, J. A., Hulley, S., & Lee, B. K. (2018). Wearable Cardioverter–Defibrillator after Myocardial Infarction. New England Journal of Medicine, 379(13), 1205–1215. https://doi.org/10.1056/nejmoa1800781
- Bhatt, A. G., & Mittal, S. (2020). The wearable cardioverter-defibrillator is not needed for most high-risk patients. Heart Rhythm O2, 1(3), 230–233. https://doi.org/10.1016/j.hroo.2020.07.002
- Jagadish, P. S., Aziz, M., Chinta, V., & Khouzam, R. N. (2020). Misunderstood or Mistrusted? The Under-Utilization of the Wearable Cardioverter Defibrillator in Clinical Practice. Current Problems in Cardiology, 45(4), 100395. https://doi.org/10.1016/j.cpcardiol.2018.09.002
- Mueller-Leisse, J., Brunn, J., Zormpas, C., Hohmann, S., Hillmann, H. A. K., Eiringhaus, J., Bauersachs, J., Veltmann, C., & Duncker, D. (2021). Extended Follow-Up After Wearable Cardioverter-Defibrillator Period: The PROLONG-II Study. ESC Heart Failure, 8(6), 5142–5148. https://doi.org/10.1002/ehf2.13586
- Ellenbogen, K. A., Koneru, J. N., Sharma, P. S., Deshpande, S., Wan, C., & Szymkiewicz, S. J. (2017). Benefit of the Wearable Cardioverter-Defibrillator in Protecting Patients After Implantable-Cardioverter Defibrillator Explant. JACC: Clinical Electrophysiology, 3(3), 243–250. https://doi.org/10.1016/j.jacep.2016.09.002
- Jiang, X., Ming, W., & You, J. H. S. (2019). Potential cost‐effectiveness of wearable cardioverter‐defibrillator for patients with implantable cardioverter‐defibrillator explant in a high‐income city of China. Journal of Cardiovascular Electrophysiology, 30(11), 2387–2396. https://doi.org/10.1111/jce.14153
1–25 of 97
Citations
- Velibey, Y., Kahraman, E., Borklu, E. B., Karatas, M. B., Guvenc, T. S., & Bolca, O. (2026). Delayed ejection fraction recovery in the era of contemporary guideline-directed medical therapy: Is the conventional 3-month waiting period for device therapy still enough?. Acta Cardiologica, 1–4. https://doi.org/10.1080/00015385.2026.2714628
- Jakstaite, A. M., Mueller-Leisse, J., Hillmann, H. A. K., Hohmann, S., Eiringhaus, J., Bavendiek, U., Kempf, T., Veltmann, C., Bauersachs, J., Duncker, D., & Berliner, D. (2025). Right Ventricular Dysfunction for Prediction of Long-Term Recovery in de novo HFrEF : A PROLONG-II Substudy. ESC Heart Failure, 12(3), 2166–2176. https://doi.org/10.1002/ehf2.15236
- Guglieri, M., Lenormand, T., Bodin, A., Bisson, A., & Fauchier, L. (2025). Variabiliy in Prescribing Patterns of Wearable Cardiac Defibrillators: Current Data, Guidelines, Challenges, and Controversies. Current Cardiology Reports, 27(1). https://doi.org/10.1007/s11886-025-02321-9
- Duncker, D., Marijon, E., Metra, M., Piot, O., Fudim, M., Siebert, U., Frey, N., Maier, L. S., & Bauersachs, J. (2025). Sudden cardiac death in newly diagnosed non-ischaemic or ischaemic cardiomyopathy assessed with a wearable cardioverter-defibrillator: the German nationwide SCD-PROTECT study. European Heart Journal, 46(43), 4597–4606. https://doi.org/10.1093/eurheartj/ehaf668
- Duncker, D., Garcia, R., Bonderman, D., Casolo, G., Farkowski, M., Israel, C., & Marijon, E. (2025). A review on wearable cardioverter-defibrillators in clinical practice for sudden cardiac death prevention and heart failure management. Europace, 27(11). https://doi.org/10.1093/europace/euaf257
- Aimo, A., Codina, P., Lee, M. M. Y., & Tomasoni, D. (2024). What's New in Heart Failure? June–July 2024. European Journal of Heart Failure, 26(7), 1449–1453. https://doi.org/10.1002/ejhf.3371
- Kikuchi, N., Shiga, T., Sugawara, Y., Suzuki, A., Minami, Y., Hattori, H., Shoda, M., Hagiwara, N., & Yamaguchi, J. (2024). Clinical outcomes during and after wearable cardioverter defibrillator use in Japanese patients with heart failure: A single‐center experience. Journal of Arrhythmia, 40(6), 1462–1472. https://doi.org/10.1002/joa3.13158
- Lenormand, T., Bodin, A., & Fauchier, L. (2024). The Role of the Wearable Defibrillator in Heart Failure. Current Heart Failure Reports, 21(1), 33–42. https://doi.org/10.1007/s11897-023-00641-x
- Hillmann, H. A. K., Albert, K., & Duncker, D. (2024). Device-assoziierte Endokarditis – was ist zu beachten?. Aktuelle Kardiologie, 13(05), 380–385. https://doi.org/10.1055/a-2349-7850
- Veltmann, C., Duncker, D., Doering, M., Gummadi, S., Robertson, M., Wittlinger, T., Colley, B. J., Perings, C., Jonsson, O., Bauersachs, J., Sanchez, R., & Maier, L. S. (2024). Therapy duration and improvement of ventricular function in de novo heart failure: the Heart Failure Optimization study. European Heart Journal, 45(30), 2771–2781. https://doi.org/10.1093/eurheartj/ehae334
- Olic, J.-J., Stöllberger, C., Schukro, C., Odening, K. E., Reuschel, E., Fischer, M., Veltmann, C., Duncker, D., & Baessler, A. (2022). Usage of the wearable cardioverter-defibrillator during pregnancy. IJC Heart & Vasculature, 41, Article 101066. https://doi.org/10.1016/j.ijcha.2022.101066
- Wybraniec, M. T., Orszulak, M., Męcka, K., & Mizia-Stec, K. (2022). Heart Failure with Improved Ejection Fraction: Insight into the Variable Nature of Left Ventricular Systolic Function. International Journal of Environmental Research and Public Health, 19(21), 14400. https://doi.org/10.3390/ijerph192114400