A comparison of conventional and patient-specific instruments in total knee arthroplasty
Additional details
Identifiers
- OpenAlex
- W2013311165
- PMID
- 23900384
- URL
- http://link.springer.com/10.1007/s00264-013-2028-9
Dates
- Issued
-
July 31, 2013
References
- Bali, K., Walker, P., & Bruce, W. (2012). Custom-Fit Total Knee Arthroplasty: Our Initial Experience in 32 Knees. The Journal of Arthroplasty, 27(6), 1149–1154. https://doi.org/10.1016/j.arth.2011.12.006
- Barrack, R. L., Ruh, E. L., Williams, B. M., Ford, A. D., Foreman, K., & Nunley, R. M. (2012). Patient specific cutting blocks are currently of no proven value. The Journal of Bone and Joint Surgery. British Volume, 94-B(11_Supple_A), 95–99. https://doi.org/10.1302/0301-620x.94b11.30834
- Bäthis, H., Perlick, L., Tingart, M., Lüring, C., Zurakowski, D., & Grifka, J. (2004). Alignment in total knee arthroplasty. The Journal of Bone and Joint Surgery. British Volume, 86-B(5), 682–687. https://doi.org/10.1302/0301-620x.86b5.14927
- Bjorgul, K., Novicoff, W. M., & Saleh, K. J. (2010). Evaluating comorbidities in total hip and knee arthroplasty: available instruments. Journal of Orthopaedics and Traumatology, 11(4), 203–209. https://doi.org/10.1007/s10195-010-0115-x
- Boonen, B., Schotanus, M. G. M., & Kort, N. P. (2012). Preliminary experience with the patient-specific templating total knee arthroplasty. Acta Orthopaedica, 83(4), 387–393. https://doi.org/10.3109/17453674.2012.711700
- Chareancholvanich, K., Narkbunnam, R., & Pornrattanamaneewong, C. (2013). A prospective randomised controlled study of patient-specific cutting guides compared with conventional instrumentation in total knee replacement. The Bone & Joint Journal, 95-B(3), 354–359. https://doi.org/10.1302/0301-620x.95b3.29903
- Chauhan, S. K., Scott, R. G., Breidahl, W., & Beaver, R. J. (2004). Computer-assisted knee arthroplasty versus a conventional jig-based technique. The Journal of Bone and Joint Surgery. British Volume, 86-B(3), 372–377. https://doi.org/10.1302/0301-620x.86b3.14643
- Cheng, T., Pan, X.-Y., Mao, X., Zhang, G.-Y., & Zhang, X.-L. (2012). Little clinical advantage of computer-assisted navigation over conventional instrumentation in primary total knee arthroplasty at early follow-up. The Knee, 19(4), 237–245. https://doi.org/10.1016/j.knee.2011.10.001
- Chin, P. L., Yang, K. Y., Yeo, S. J., & Lo, N. N. (2005). Randomized Control Trial Comparing Radiographic Total Knee Arthroplasty Implant Placement Using Computer Navigation Versus Conventional Technique. The Journal of Arthroplasty, 20(5), 618–626. https://doi.org/10.1016/j.arth.2005.04.004
- Collier, M. B., Engh, C. A., McAuley, J. P., & Engh, G. A. (2007). Factors Associated with the Loss of Thickness of Polyethylene Tibial Bearings After Knee Arthroplasty. The Journal of Bone & Joint Surgery, 89(6), 1306–1314. https://doi.org/10.2106/jbjs.f.00667
- Conteduca, F., Iorio, R., Mazza, D., Caperna, L., Bolle, G., Argento, G., & Ferretti, A. (2012). Are MRI-based, patient matched cutting jigs as accurate as the tibial guides?. International Orthopaedics, 36(8), 1589–1593. https://doi.org/10.1007/s00264-012-1522-9
- Daniilidis, K., & Tibesku, C. O. (2012). Frontal plane alignment after total knee arthroplasty using patient-specific instruments. International Orthopaedics, 37(1), 45–50. https://doi.org/10.1007/s00264-012-1732-1
- Decking, R., Markmann, Y., Fuchs, J., Puhl, W., & Scharf, H.-P. (2005). Leg Axis After Computer-Navigated Total Knee Arthroplasty. The Journal of Arthroplasty, 20(3), 282–288. https://doi.org/10.1016/j.arth.2004.09.047
- Drummond, M., Barbieri, M., Cook, J., Glick, H. A., Lis, J., Malik, F., Reed, S. D., Rutten, F., Sculpher, M., & Severens, J. (2009). Transferability of Economic Evaluations Across Jurisdictions: ISPOR Good Research Practices Task Force Report. Value in Health, 12(4), 409–418. https://doi.org/10.1111/j.1524-4733.2008.00489.x
- Haaker, R. G., Stockheim, M., Kamp, M., Proff, G., Breitenfelder, J., & Ottersbach, A. (2005). Computer-Assisted Navigation Increases Precision of Component Placement in Total Knee Arthroplasty. Clinical Orthopaedics and Related Research, &NA;(433), 152–159. https://doi.org/10.1097/01.blo.0000150564.31880.c4
- Hafez, M. A., Chelule, K. L., Seedhom, B. B., & Sherman, K. P. (2006). Computer-assisted Total Knee Arthroplasty Using Patient-specific Templating. Clinical Orthopaedics & Related Research, 444, 184–192. https://doi.org/10.1097/01.blo.0000201148.06454.ef
- Hart, R., Janecek, M., Chaker, A., & Bucek, P. (2003). Total knee arthroplasty implanted with and without kinematic navigation. International Orthopaedics, 27(6), 366–369. https://doi.org/10.1007/s00264-003-0501-6
- Heyse TJ, Tibesku CO (2012) Improved femoral component rotation in TKA using patient-specific instrumentation. Knee. doi: 10.1016/j.knee.2012.10.009
- Howell, S. M., Kuznik, K., Hull, M. L., & Siston, R. A. (2008). Results of an Initial Experience With Custom-fit Positioning Total Knee Arthroplasty in a Series of 48 Patients. Orthopedics, 31(9), 857–863. https://doi.org/10.3928/01477447-20080901-15
- Jeffery, R., Morris, R., & Denham, R. (1991). Coronal alignment after total knee replacement. The Journal of Bone and Joint Surgery. British Volume, 73-B(5), 709–714. https://doi.org/10.1302/0301-620x.73b5.1894655
- Jenny, J.-Y., Miehlke, R. K., & Giurea, A. (2008). Learning curve in navigated total knee replacement. A multi-centre study comparing experienced and beginner centres. The Knee, 15(2), 80–84. https://doi.org/10.1016/j.knee.2007.12.004
- Johnson DR (2011) The benefits of customized patient instrumentation to lower-volume joint replacement surgeons: results from practice. Am J Orthop (Belle Mead NJ) 40(11 Suppl):13–16
- Kim, Y.-H., Kim, J.-S., & Yoon, S.-H. (2007). Alignment and orientation of the components in total knee replacement with and without navigation support. The Journal of Bone and Joint Surgery. British Volume, 89-B(4), 471–476. https://doi.org/10.1302/0301-620x.89b4.18878
- Klatt, B. A., Goyal, N., Austin, M. S., & Hozack, W. J. (2008). Custom-Fit Total Knee Arthroplasty (OtisKnee) Results in Malalignment. The Journal of Arthroplasty, 23(1), 26–29. https://doi.org/10.1016/j.arth.2007.10.001
- Koeck, F. X., Beckmann, J., Luring, C., Rath, B., Grifka, J., & Basad, E. (2011). Evaluation of implant position and knee alignment after patient-specific unicompartmental knee arthroplasty. The Knee, 18(5), 294–299. https://doi.org/10.1016/j.knee.2010.06.008
- Lustig, S., Scholes, C. J., Oussedik, S. I., Kinzel, V., Coolican, M. R. J., & Parker, D. A. (2013). Unsatisfactory Accuracy as Determined by Computer Navigation of VISIONAIRE Patient-Specific Instrumentation for Total Knee Arthroplasty. The Journal of Arthroplasty, 28(3), 469–473. https://doi.org/10.1016/j.arth.2012.07.012
- Matsumoto, T., Tsumura, N., Kurosaka, M., Muratsu, H., Kuroda, R., Ishimoto, K., Tsujimoto, K., Shiba, R., & Yoshiya, S. (2004). Prosthetic alignment and sizing in computer-assisted total knee arthroplasty. International Orthopaedics, 28(5), 282–285. https://doi.org/10.1007/s00264-004-0562-1
- Matziolis, G., Krocker, D., Weiss, U., Tohtz, S., & Perka, C. (2007). A Prospective, Randomized Study of Computer-Assisted and Conventional Total Knee Arthroplasty. The Journal of Bone & Joint Surgery, 89(2), 236–243. https://doi.org/10.2106/jbjs.f.00386
- Nam D, Maher PA, Rebolledo BJ, Nawabi DH, McLawhorn AS, Pearle AD (2013) Patient specific cutting guides versus an imageless, computer-assisted surgery system in total knee arthroplasty. Knee. doi: 10.1016/j.knee.2012.12.009
- Ng, V. Y., DeClaire, J. H., Berend, K. R., Gulick, B. C., & Lombardi, A. V. (2012). Improved Accuracy of Alignment With Patient-specific Positioning Guides Compared With Manual Instrumentation in TKA. Clinical Orthopaedics & Related Research, 470(1), 99–107. https://doi.org/10.1007/s11999-011-1996-6
- Noble, J. W., Moore, C. A., & Liu, N. (2012). The Value of Patient-Matched Instrumentation in Total Knee Arthroplasty. The Journal of Arthroplasty, 27(1), 153–155. https://doi.org/10.1016/j.arth.2011.07.006
- Nunley, R. M., Ellison, B. S., Zhu, J., Ruh, E. L., Howell, S. M., & Barrack, R. L. (2012). Do Patient-specific Guides Improve Coronal Alignment in Total Knee Arthroplasty?. Clinical Orthopaedics & Related Research, 470(3), 895–902. https://doi.org/10.1007/s11999-011-2222-2
- RITTER, M. A., FARIS, P. M., KEATING, E. M., & MEDING, J. B. (1994). Postoperative Alignment of Total Knee Replacement Its Effect on Survival. Clinical Orthopaedics and Related Research, 299, 153???156. https://doi.org/10.1097/00003086-199402000-00021
- Sampath, S. A. C., Voon, S. H., Sangster, M., & Davies, H. (2009). The statistical relationship between varus deformity, surgeon's experience, BMI and tourniquet time for computer assisted total knee replacements. The Knee, 16(2), 121–124. https://doi.org/10.1016/j.knee.2008.09.008
- Sharkey, P. F., Hozack, W. J., Rothman, R. H., Shastri, S., & Jacoby, S. M. (2002). Why Are Total Knee Arthroplasties Failing Today?. Clinical Orthopaedics and Related Research, 404, 7–13. https://doi.org/10.1097/00003086-200211000-00003
- Sikorski, J. M. (2008). Alignment in total knee replacement. The Journal of Bone and Joint Surgery. British Volume, 90-B(9), 1121–1127. https://doi.org/10.1302/0301-620x.90b9.20793
- Sparmann, M., Wolke, B., Czupalla, H., Banzer, D., & Zink, A. (2003). Positioning of total knee arthroplasty with and without navigation support. The Journal of Bone and Joint Surgery. British Volume, 85-B(6), 830–835. https://doi.org/10.1302/0301-620x.85b6.13722
- Spencer, B. A., Mont, M. A., McGrath, M. S., Boyd, B., & Mitrick, M. F. (2008). Initial experience with custom-fit total knee replacement: intra-operative events and long-leg coronal alignment. International Orthopaedics, 33(6), 1571–1575. https://doi.org/10.1007/s00264-008-0693-x
- Srivastava, A., Lee, G. Y., Steklov, N., Colwell, C. W., Ezzet, K. A., & D'Lima, D. D. (2012). Effect of tibial component varus on wear in total knee arthroplasty. The Knee, 19(5), 560–563. https://doi.org/10.1016/j.knee.2011.11.003
- St??ckl, B., Nogler, M., Rosiek, R., Fischer, M., Krismer, M., & Kessler, O. (2004). Navigation Improves Accuracy of Rotational Alignment in Total Knee Arthroplasty. Clinical Orthopaedics and Related Research, 426, 180–186. https://doi.org/10.1097/01.blo.0000136835.40566.d9
- STULBERG, S. D., LOAN, P., & SARIN, V. (2002). COMPUTER-ASSISTED NAVIGATION IN TOTAL KNEE REPLACEMENT. The Journal of Bone and Joint Surgery-American Volume, 84, 90–98. https://doi.org/10.2106/00004623-200200002-00011
- TILLETT, E. D., ENGH, G. A., & PETERSEN, T. (1988). A Comparative Study of Extramedullary and Intramedullary Alignment Systems in Total Knee Arthroplasty. Clinical Orthopaedics and Related Research, 230, 176–181. https://doi.org/10.1097/00003086-198805000-00019
- Werner, F. W., Ayers, D. C., Maletsky, L. P., & Rullkoetter, P. J. (2005). The effect of valgus/varus malalignment on load distribution in total knee replacements. Journal of Biomechanics, 38(2), 349–355. https://doi.org/10.1016/j.jbiomech.2004.02.024
- Yaffe, M. A., Patel, A., Mc Coy, B. W., Luo, M., Cayo, M., Ghate, R., & Stulberg, S. D. (2012). Component sizing in total knee arthroplasty: patient-specific guides vs. computer-assisted navigation. Biomedizinische Technik/Biomedical Engineering, 57(4). https://doi.org/10.1515/bmt-2011-0093
- Yau, W. P., Chiu, K. Y., Zuo, J. L., Tang, W. M., & Ng, T. P. (2008). Computer Navigation Did Not Improve Alignment in a Lower-volume Total Knee Practice. Clinical Orthopaedics & Related Research, 466(4), 935–945. https://doi.org/10.1007/s11999-008-0144-4
Citations
- Zhao, C., Jefferies, J. G., Marimuthu, K., Kumar, V. S., Chen, D., Harris, I. A., MacDessi, S. J., & Service, C. C. E. (2026). Patient-specific cutting guides for total knee arthroplasty. Cochrane Database of Systematic Reviews, 2026(1). https://doi.org/10.1002/14651858.cd012589.pub2
- ALSHEWAIER, S. A., ALSHEHRI, M. A. G., BEGUM, S. S., SIKKANDAR, M. Y., ALMUKIL, A. A. A., & ALHAZMI, A. M. (2023). FINITE ELEMENT ANALYSIS OF CUSTOMIZED KNEE IMPLANTS BY VARYING LOADS DURING FLEXION-EXTENSION MOVEMENT. Journal of Mechanics in Medicine and Biology, 23(06). https://doi.org/10.1142/s021951942340016x
- Tibesku, C. O., Haas, S. B., Saunders, C., & Harwood, D. A. (2022). Comparison of clinical outcomes of VISIONAIRE patient-specific instrumentation with conventional instrumentation in total knee arthroplasty: a systematic literature review and meta-analysis. Archives of Orthopaedic and Trauma Surgery, 143(7), 4379–4393. https://doi.org/10.1007/s00402-022-04698-6
- Shetty, V., Shekhar, S., Karade, V., Maurya, A., Sankar, M., & Wagh, Y. (2022). A Study of Surgical Accuracy with X-Ray-Based Patient-Specific Instrument (X3DPSI®) vs Conventional Instrument in Total Knee Arthroplasty Surgeries. Indian Journal of Orthopaedics, 56(7), 1240–1250. https://doi.org/10.1007/s43465-022-00623-6
- Hampton, M. J., Blakey, C. M., Anderson, A. A., Tomouk, W. M., Buckley, S. C., Hamer, A. J., & Sutton, P. M. (2022). Minimum 5-Year Outcomes of a Multicenter, Prospective, Randomized Control Trial Assessing Clinical and Radiological Outcomes of Patient-Specific Instrumentation in Total Knee Arthroplasty. The Journal of Arthroplasty, 37(8), 1579–1585. https://doi.org/10.1016/j.arth.2022.01.039
- Pereira, E. G., Carvalho, M. M., Oliveira, T., Sacramento, T., Cruz, H., Viegas, R., Fontes, A. P., Marreiros, A., & Sousa, J. P. (2021). Benefits of Tranexamic Acid in Total Knee Arthroplasty: A Classification and Regression Tree Analysis in Function of Instrumentation, BMI, and Gender. The Journal of Knee Surgery, 36(02), 173–180. https://doi.org/10.1055/s-0041-1731455
- Massé, V., & Ghate, R. S. (2021). Using standard X-ray images to create 3D digital bone models and patient-matched guides for aiding implant positioning and sizing in total knee arthroplasty. Computer Assisted Surgery, 26(1), 31–40. https://doi.org/10.1080/24699322.2021.1894239
- Tirnovanu, S., Savin, L., Forna, N., Scolobiuc, D., Antonescu, I., Sirbu, M., & Sirbu, P. (2021). Custom-Made Cutting Blocks for Total Knee Arthroplasty: Two Case Reports and Preliminary Results. 2021 International Conference on e-Health and Bioengineering (EHB), 1–4. https://doi.org/10.1109/ehb52898.2021.9657690
- Deng, T., Liu, T., Lei, Q., Cai, L., & Chen, S. (2021). Patient-specific instrumentation combined with a new tool for gap balancing is useful in total knee replacement: a 3-year follow-up of a retrospective study. Journal of Orthopaedic Surgery and Research, 16(1). https://doi.org/10.1186/s13018-021-02467-6
- Foruria, X., Moreta, J., Jaramillo, C., Anton, A., Calvo, I., Guerrero, J. A., & de losMozos, J. L. M. (2020). CLINICAL AND RADIOLOGICAL RESULTS OF TOTAL KNEE REPLACEMENT USING PATIENT-SPECIFIC POSITIONING GUIDES WITH AT LEAST 5 YEARS OF FOLLOW-UP. Journal of Musculoskeletal Research, 23(04), 2050020. https://doi.org/10.1142/s0218957720500207
- Chanalithichai, N., Tammachote, N., Jitapunkul, C., & Kanitnate, S. (2019). Rotational component alignment in patient-specific total knee arthroplasty compared with conventional cutting instrument. European Journal of Orthopaedic Surgery & Traumatology, 29(6), 1297–1304. https://doi.org/10.1007/s00590-019-02423-5
- Cabarcas, B. C., Cvetanovich, G. L., Gowd, A. K., Liu, J. N., Manderle, B. J., & Verma, N. N. (2019). Accuracy of patient-specific instrumentation in shoulder arthroplasty: a systematic review and meta-analysis. JSES Open Access, 3(3), 117–129. https://doi.org/10.1016/j.jses.2019.07.002
- León-Muñoz, V. J., Martínez-Martínez, F., López-López, M., & Santonja-Medina, F. (2019). Patient-specific instrumentation in total knee arthroplasty. Expert Review of Medical Devices, 16(7), 555–567. https://doi.org/10.1080/17434440.2019.1627197
- Pauzenberger, L., Munz, M., Brandl, G., Frank, J. K., Heuberer, P. R., Laky, B., Schwameis, E., & Anderl, W. (2019). Patient-specific instrumentation improved three-dimensional accuracy in total knee arthroplasty: a comparative radiographic analysis of 1257 total knee arthroplasties. Journal of Orthopaedic Surgery and Research, 14(1). https://doi.org/10.1186/s13018-019-1465-6
- McAuliffe, M. J., Beer, B. R., Hatch, J. J., Crawford, R. W., Cuthbert, A. R., & Donnelly, W. J. (2019). Impact of Image-Derived Instrumentation on Total Knee Arthroplasty Revision Rates. Journal of Bone and Joint Surgery, 101(7), 580–588. https://doi.org/10.2106/jbjs.18.00326
- Gong, S., Xu, W., Wang, R., Wang, Z., Wang, B., Han, L., & Chen, G. (2018). Patient-specific instrumentation improved axial alignment of the femoral component, operative time and perioperative blood loss after total knee arthroplasty. Knee Surgery, Sports Traumatology, Arthroscopy, 27(4), 1083–1095. https://doi.org/10.1007/s00167-018-5256-0
- Shoji, H., Teramoto, A., Suzuki, T., Okada, Y., Watanabe, K., & Yamashita, T. (2018). Radiographic assessment and clinical outcomes after total knee arthroplasty using an accelerometer-based portable navigation device. Arthroplasty Today, 4(3), 319–322. https://doi.org/10.1016/j.artd.2017.11.012
- Tammachote, N., Panichkul, P., & Kanitnate, S. (2018). Comparison of Customized Cutting Block and Conventional Cutting Instrument in Total Knee Arthroplasty: A Randomized Controlled Trial. The Journal of Arthroplasty, 33(3), 746–751.e3. https://doi.org/10.1016/j.arth.2017.09.055
- Chi-Kay, L., King-him, C., Kin-bong, L., & Wilson, L. (2018). Computer-Assisted Planning and Three-Dimensional-Printed Patient-Specific Instrumental Guide for Corrective Osteotomy in Post-Traumatic Femur Deformity: A Case Report and Literature Review. Journal of Orthopaedics, Trauma and Rehabilitation, 24(1), 12–17. https://doi.org/10.1016/j.jotr.2016.11.002
- Arbab, D., Reimann, P., Brucker, M., Bouillon, B., & Lüring, C. (2018). Alignment in total knee arthroplasty — A comparison of patient-specific implants with the conventional technique. The Knee, 25(5), 882–887. https://doi.org/10.1016/j.knee.2018.05.017
- Stone, A. H., Sibia, U. S., & MacDonald, J. H. (2018). Functional Outcomes and Accuracy of Patient-Specific Instruments for Total Knee Arthroplasty. Surgical Innovation, 25(5), 470–475. https://doi.org/10.1177/1553350618787074
- Moewis, P., Checa, S., Kutzner, I., Hommel, H., Duda, G. N., & Williams, J. L. (2018). Physiological joint line total knee arthroplasty designs are especially sensitive to rotational placement – A finite element analysis. PLOS ONE, 13(2), e0192225. https://doi.org/10.1371/journal.pone.0192225
- MacDessi, S., Marimuthu, K., Kumar, V. S., Chen, D., Harris, I. A., & Group, C. M. (2017). Patient-specific cutting guides for total knee arthroplasty. Cochrane Database of Systematic Reviews. https://doi.org/10.1002/14651858.cd012589
- Yamamura, K., Minoda, Y., Mizokawa, S., Ohta, Y., Sugama, R., Nakamura, S., Ueyama, H., & Nakamura, H. (2017). Novel alignment measurement technique for total knee arthroplasty using patient specific instrumentation. Archives of Orthopaedic and Trauma Surgery, 137(3), 401–407. https://doi.org/10.1007/s00402-017-2628-8
- Teles Rodrigues, A. S., & Pereira Gutierres, M. A. (2017). Instrumentação personalizada na artroplastia total do joelho. Devemos adotá‐la?. Revista Brasileira de Ortopedia, 52(3), 242–250. https://doi.org/10.1016/j.rbo.2017.04.002
1–25 of 56