Correlation of Electrically Evoked Compound Action Potential Amplitude Growth Function Slope and Anamnestic Parameters in Cochlear Implant Patients—Identification of Predictors for the Neuronal Health Status
Authors/Creators
-
1.
Medizinische Hochschule Hannover
- 2. Department of Otolaryngology, Hannover Medical School, 30625 Hannover, Germany
-
3.
Hearing4all
Description
Cochlear implants (CI) are the treatment of choice in profoundly deaf patients. Measuring the electrically evoked compound action potential (ECAP) has become an important tool for verifying the function of the spiral ganglion neurons (SGN), which are the target cells of the CI stimulation. ECAP measurement is only possible after electrode insertion. No information about the neuronal health status is available before cochlear implantation. We investigated possible correlations between the ECAP amplitude growth function (AGF) slope and anamnestic parameters to identify possible predictors for SGN health status and therefore for CI outcome. The study included patients being implanted with various electrode array lengths. Correlation analysis was performed for the mean AGF slope of the whole array, for separate electrodes as well as for grouped electrodes of the apical, medial, and basal region, with duration of deafness, age at implantation, residual hearing (grouped for electrode length), and etiology. The mean ECAP AGF slopes decreased from apical to basal. They were not correlated to the length of the electrode array or any etiology. For the mean of the full array or when grouped for the apical, middle, and basal part, the ECAP AGF slope was negatively correlated to the duration of hearing loss and the age at implantation. Since a significant negative correlation of the ECAP AGF slope and age at cochlear implantation and duration of deafness was observed, this study supports the statement that early implantation of a CI is recommended for sensorineural hearing loss. Additional factors such as the cochlear coverage and insertion angle influence the ECAP AGF slope and performance of the patient and should be included in future multifactorial analysis to study predictive parameters for the CI outcome.
Additional details
Identifiers
- OpenAlex
- W3135834809
- PMID
- 33807687
- URL
- https://www.mdpi.com/2075-1729/11/3/203
Funding
-
Deutsche Forschungsgemeinschaft
- EXC 2177/1
Dates
- Issued
-
March 5, 2021
References
- WHO (2021, February 01). Deafness and Hearing Loss. Fact Sheet. Available online: https://www.who.int/mediacentre/factsheets/fs300/en
- Hoppe, U., Hocke, T., Hast, A., & Iro, H. (2019). Maximum preimplantation monosyllabic score as predictor of cochlear implant outcome. HNO, 67(S2), 62–68. https://doi.org/10.1007/s00106-019-0648-0
- Shearer, A. E., Eppsteiner, R. W., Frees, K., Tejani, V., Sloan-Heggen, C. M., Brown, C., Abbas, P., Dunn, C., Hansen, M. R., Gantz, B. J., & Smith, R. J. H. (2017). Genetic variants in the peripheral auditory system significantly affect adult cochlear implant performance. Hearing Research, 348, 138–142. https://doi.org/10.1016/j.heares.2017.02.008
- Hall, R. D. (1990). Estimation of surviving spiral ganglion cells in the deaf rat using the electrically evoked auditory brainstem response. Hearing Research, 49(1-3), 155–168. https://doi.org/10.1016/0378-5955(90)90102-u
- Vink, H. A., van Dorp, W. C., Thomeer, H. G. X. M., Versnel, H., & Ramekers, D. (2020). BDNF Outperforms TrkB Agonist 7,8,3′-THF in Preserving the Auditory Nerve in Deafened Guinea Pigs. Brain Sciences, 10(11), 787. https://doi.org/10.3390/brainsci10110787
- Dziemba, O. C., Aristeidou, A., & Brill, S. (2020). Slope of electrically evoked compound action potential amplitude growth function is site-dependent. Cochlear Implants International, 22(3), 136–147. https://doi.org/10.1080/14670100.2020.1853956
- Mlynski, R., Lüsebrink, A., Oberhoffner, T., Langner, S., & Weiss, N. M. (2020). Mapping Cochlear Duct Length to Electrically Evoked Compound Action Potentials in Cochlear Implantation. Otology & Neurotology, 42(3), e254–e260. https://doi.org/10.1097/mao.0000000000002957
- Brill, S., Müller, J., Hagen, R., Möltner, A., Brockmeier, S.-J., Stark, T., Helbig, S., Maurer, J., Zahnert, T., Zierhofer, C., Nopp, P., Anderson, I., & Strahl, S. (2009). Site of cochlear stimulation and its effect on electrically evoked compound action potentials using the MED-EL standard electrode array. BioMedical Engineering OnLine, 8(1). https://doi.org/10.1186/1475-925x-8-40
- Jahn, K. N., & Arenberg, J. G. (2020). Identifying Cochlear Implant Channels With Relatively Poor Electrode-Neuron Interfaces Using the Electrically Evoked Compound Action Potential. Ear & Hearing, 41(4), 961–973. https://doi.org/10.1097/aud.0000000000000844
- Pfingst, B. E., Hughes, A. P., Colesa, D. J., Watts, M. M., Strahl, S. B., & Raphael, Y. (2015). Insertion trauma and recovery of function after cochlear implantation: Evidence from objective functional measures. Hearing Research, 330, 98–105. https://doi.org/10.1016/j.heares.2015.07.010
- Spoendlin, H. (1975). Retrograde Degeneration of the Cochlear Nerve. Acta Oto-Laryngologica, 79(3-6), 266–275. https://doi.org/10.3109/00016487509124683
- Versnel, H., Agterberg, M. J. H., de Groot, J. C. M. J., Smoorenburg, G. F., & Klis, S. F. L. (2007). Time course of cochlear electrophysiology and morphology after combined administration of kanamycin and furosemide. Hearing Research, 231(1-2), 1–12. https://doi.org/10.1016/j.heares.2007.03.003
- Glueckert, R., Pfaller, K., Kinnefors, A., Rask-Andersen, H., & Schrott-Fischer, A. (2005). The Human Spiral Ganglion: New Insights into Ultrastructure, Survival Rate and Implications for Cochlear Implants. Audiology and Neurotology, 10(5), 258–273. https://doi.org/10.1159/000086000
- Nadol, J. B., Young, Y.-S., & Glynn, R. J. (1989). Survival of Spiral Ganglion Cells in Profound Sensorineural Hearing Loss: Implications for Cochlear Implantation. Annals of Otology, Rhinology & Laryngology, 98(6), 411–416. https://doi.org/10.1177/000348948909800602
- Landry, T. G., Fallon, J. B., Wise, A. K., & Shepherd, R. K. (2013). Chronic neurotrophin delivery promotes ectopic neurite growth from the spiral ganglion of deafened cochleae without compromising the spatial selectivity of cochlear implants. Journal of Comparative Neurology, 521(12), 2818–2832. https://doi.org/10.1002/cne.23318
- Seyyedi, M., & Nadol, J. B. (2014). Intracochlear Inflammatory Response to Cochlear Implant Electrodes in Humans. Otology & Neurotology, 35(9), 1545–1551. https://doi.org/10.1097/mao.0000000000000540
- Shepherd, R. K., Coco, A., Epp, S. B., & Crook, J. M. (2005). Chronic depolarization enhances the trophic effects of brain‐derived neurotrophic factor in rescuing auditory neurons following a sensorineural hearing loss. Journal of Comparative Neurology, 486(2), 145–158. https://doi.org/10.1002/cne.20564
- Shibata, S. B., Cortez, S. R., Beyer, L. A., Wiler, J. A., Di Polo, A., Pfingst, B. E., & Raphael, Y. (2010). Transgenic BDNF induces nerve fiber regrowth into the auditory epithelium in deaf cochleae. Experimental Neurology, 223(2), 464–472. https://doi.org/10.1016/j.expneurol.2010.01.011
- Fayad, J. N., & Linthicum, F. H. (2006). Multichannel Cochlear Implants: Relation of Histopathology to Performance. The Laryngoscope, 116(8), 1310–1320. https://doi.org/10.1097/01.mlg.0000227176.09500.28
- Xu, H. X., Kim, G. H., Snissarenko, E. P., Cureoglu, S., & Paparella, M. M. (2012). Multi-channel cochlear implant histopathology: Are fewer spiral ganglion cells really related to better clinical performance?. Acta Oto-Laryngologica, 132(5), 482–490. https://doi.org/10.3109/00016489.2011.647361
- Preliminary experience with neural response telemetry in the nucleus CI24M cochlear implant
- He, S., Teagle, H. F. B., & Buchman, C. A. (2017). The Electrically Evoked Compound Action Potential: From Laboratory to Clinic. Frontiers in Neuroscience, 11. https://doi.org/10.3389/fnins.2017.00339
- Jakobsen, J. C., Gluud, C., Wetterslev, J., & Winkel, P. (2017). When and how should multiple imputation be used for handling missing data in randomised clinical trials – a practical guide with flowcharts. BMC Medical Research Methodology, 17(1). https://doi.org/10.1186/s12874-017-0442-1
- Scheper, V., Schmidtheisler, M., Lasch, F., von der Leyen, H., Koch, A., Schwieger, J., Büchner, A., Lesinski-Schiedat, A., & Lenarz, T. (2020). Randomized placebo-controlled clinical trial investigating the effect of antioxidants and a vasodilator on overall safety and residual hearing preservation in cochlear implant patients. Trials, 21(1). https://doi.org/10.1186/s13063-020-04522-9
- Finley, C. C., Holden, T. A., Holden, L. K., Whiting, B. R., Chole, R. A., Neely, G. J., Hullar, T. E., & Skinner, M. W. (2008). Role of Electrode Placement as a Contributor to Variability in Cochlear Implant Outcomes. Otology & Neurotology, 29(7), 920–928. https://doi.org/10.1097/mao.0b013e318184f492
1–25 of 48
Citations
- Mala, M., Sinha, R., & Singh, R. K. (2026). Predictive Value of Intraoperative ECAP Thresholds and Impedance in Pediatric Cochlear Implantation: A Longitudinal Study. Indian Journal of Otolaryngology and Head & Neck Surgery, 78(11), 5408–5415. https://doi.org/10.1007/s12070-026-06869-y
- Marx, J., Huang, P., Sutter, S. O., Ertelt, M., Kaiser, O., Harre, J., Schott, J., Wilkes, J., Neek-John, P., Rossi, A., Warnecke, A., Schoeder, C. T., Schambach, A., Staecker, H., & Büning, H. (2026). Capsid-engineered AAV vector overcomes a key intracellular barrier and efficiently transduces spiral ganglion neurons in adult mice. Molecular Therapy Advances, 34(1), Article 201669. https://doi.org/10.1016/j.omta.2026.201669
- https://doi.org/10.26599/joto.2026.9540047
- https://doi.org/10.1177/23312165251347138
- https://doi.org/10.3389/fnins.2025.1647513
- Schrank, L., Nachtigäller, P., Müller, J., Hempel, J.-M., Canis, M., Spiegel, J. L., & Rader, T. (2024). ART and AutoART ECAP measurements and cochlear nerve anatomy as predictors in adult cochlear implant recipients. European Archives of Oto-Rhino-Laryngology, 281(7), 3461–3473. https://doi.org/10.1007/s00405-023-08444-5
- https://doi.org/10.1159/000540576
- https://doi.org/10.3390/jcm13164716
- Mussoi, B. S., Woodson, E., & Sydlowski, S. (2023). The Effect of Aging on Auditory Nerve Function: Insights from Intraoperative eCAP Recordings in Cochlear Implant Users. Otology & Neurotology, 44(5), 447–452. https://doi.org/10.1097/mao.0000000000003862
- https://doi.org/10.1186/s43163-023-00448-6
- Lenarz, T., Büchner, A., & Illg, A. (2022). Cochlea-Implantation: Konzept, Therapieergebnisse und Lebensqualität. Laryngo-Rhino-Otologie, 101(S 01), S36–S78. https://doi.org/10.1055/a-1731-9321
- https://doi.org/10.1371/journal.pone.0259347