Radiological examination of dental castings – a review of the method and comparisons of the equipment
Authors/Creators
Description
summary The mechanical stability of crowns or bridges as well as frameworks for removable partial dentures depends on factors like thickness and metal structure. The biological compatibility can be influenced by porosities and soldered joints.Radiological testing is a non‐destructive method to check defects in dental castings. As dental precious metal alloys have high X‐ray absorption, testing of high gold alloys should be performed with a suitable X‐ray machine at a tube voltage of 120 kV since the X‐ray penetration of dental X‐ray units using a tube voltage of 70 to 80 kV is not high enough for these alloys. As the absorption of Co–Cr alloys and of titanium is much lower, these materials can be tested with a dental X‐ray apparatus.The radiographs show location and size of metal defects. They enable an examination of metal thickness and content of porosities. Metal defects reducing the biological compatibility or cast stability can be detected prior to clinical fitting.
Additional details
Identifiers
Dates
- Issued
-
July 2002
References
- The fracture of cobalt‐chromium alloy removable partial dentures
- Dharmar, S., Rathnasamy, R. J., & Swaminathan, T. N. (1993). Radiographic and metallographic evaluation of porosity defects and grain structure of cast chromium cobalt removable partial dentures. The Journal of Prosthetic Dentistry, 69(4), 369–373. https://doi.org/10.1016/0022-3913(93)90182-n
- Eisenburger, M., & Tschernitschek, H. (1998). Radiographic inspection of dental castings. Clinical Oral Investigations, 2(1), 11–14. https://doi.org/10.1007/s007840050036
- Elarbi, E. A., Ismail, Y. H., Azarbal, M., & Saini, T. S. (1985). Radiographic detection of porosities in removable partial denture castings. The Journal of Prosthetic Dentistry, 54(5), 674–677. https://doi.org/10.1016/0022-3913(85)90248-3
- Möglichkeiten und Grenzen der Röntgendefektoskopie
- Fractures of cobalt–chromium castings
- Kontrolluntersuchungen an parodontal und parodontal‐gingival gelagerten Teilprothesen
- Mattila, K. (1964). A Roentgenological Study of Internal Defects in Chrome-Cobalt Implants and Partial Dentures. Acta Odontologica Scandinavica, 22(2), 215–228. https://doi.org/10.3109/00016356409003026
- van Noort, R., & Lamb, D. J. (1984). A scanning electron microscope study of CoCr partial dentures fractured in service. Journal of Dentistry, 12(2), 122–126. https://doi.org/10.1016/0300-5712(84)90045-9
- Nachuntersuchungen von Modellgußprothesen nach vierjähriger Tragezeit
- Qualitätsüberprüfung zahnärztlicher Gußobjekte durch Röntgendefektographie
- WICTORIN, L., JULIN, P., & MÖLLERSTEN, L. (1979). Roentgenological detection of casting defects in cobalt‐chromium alloy frameworks. Journal of Oral Rehabilitation, 6(2), 137–146. https://doi.org/10.1111/j.1365-2842.1979.tb01273.x
- Röntgenologische Untersuchung von Modellgußgerüsten
Citations
- Al Jabbari, Y. S., Dimitriadis, K., Sufyan, A., & Zinelis, S. (2024). Microstructural and mechanical characterization of six Co-Cr alloys made by conventional casting and selective laser melting. The Journal of Prosthetic Dentistry, 132(3), 646.e1–646.e10. https://doi.org/10.1016/j.prosdent.2024.06.015
- El-Tamimi, K. M., Bayoumi, D. A., Alshenaiber, R., Aljulayfi, I., Ahmed, M. M. Z., & El-Sayed, M. E. (2024). Deformation and retentive forces variations of the additively manufactured cobalt-chromium and titanium alloys dental clasps. The Saudi Dental Journal, 36(6), 947–953. https://doi.org/10.1016/j.sdentj.2024.04.001
- Chen, Y.-C., Chang, M.-C., Hsiao, W.-Y., & Chen, Y.-C. (2023). Castability of a Ti-7.5Mo alloy for fabricating frameworks for removable partial dentures. The Journal of Prosthetic Dentistry, 130(4), 646–653. https://doi.org/10.1016/j.prosdent.2021.10.014
- Zidan, N., & AL-Saadi, M. H. (2021). Microstructure, Hardness and Corrosion Resistance of Co–Cr Alloy Fabricated by Casting or Selective Laser Melting Technique. Journal of The Institution of Engineers (India): Series C, 102(3), 731–739. https://doi.org/10.1007/s40032-021-00700-z
- https://doi.org/10.4236/jbise.2021.1412038
- Takahashi, K., Torii, M., Nakata, T., Kawamura, N., Shimpo, H., & Ohkubo, C. (2020). Fitness accuracy and retentive forces of additive manufactured titanium clasp. Journal of Prosthodontic Research, 64(4), 468–477. https://doi.org/10.1016/j.jpor.2020.01.001
- Al Jabbari, Y. S., Barmpagadaki, X., Psarris, I., & Zinelis, S. (2019). Microstructural, mechanical, ionic release and tarnish resistance characterization of porcelain fused to metal Co–Cr alloys manufactured via casting and three different CAD/CAM techniques. Journal of Prosthodontic Research, 63(2), 150–156. https://doi.org/10.1016/j.jpor.2018.10.008
- https://doi.org/10.1515/ama-2017-0008
- https://doi.org/10.4012/dmj.2017-137
- https://doi.org/10.3390/ma9070596
- Tuna, S. H., Özçiçek Pekmez, N., & Kürkçüoğlu, I. (2015). Corrosion resistance assessment of Co-Cr alloy frameworks fabricated by CAD/CAM milling, laser sintering, and casting methods. The Journal of Prosthetic Dentistry, 114(5), 725–734. https://doi.org/10.1016/j.prosdent.2015.02.031
- Al Jabbari, Y. S., Koutsoukis, T., Barmpagadaki, X., & Zinelis, S. (2014). Metallurgical and interfacial characterization of PFM Co–Cr dental alloys fabricated via casting, milling or selective laser melting. Dental Materials, 30(4), e79–e88. https://doi.org/10.1016/j.dental.2014.01.008
- https://doi.org/10.4047/jap.2014.6.2.138
- Keni, N. N., Aras, M. A., & Chitre, V. (2012). Customised Attachments Retained Cheek Plumper Prosthesis: A Case Report. The Journal of Indian Prosthodontic Society, 12(3), 198–200. https://doi.org/10.1007/s13191-012-0132-y
- https://doi.org/10.1111/j.1741-2358.2010.00376.x
- https://doi.org/10.1590/s1678-77572010000500010
- https://doi.org/10.1111/j.1532-849x.2009.00459.x
- https://doi.org/10.1111/j.0305-182x.2007.01821.x
- https://doi.org/10.1111/j.1365-2842.2007.01821.x
- https://doi.org/10.4028/www.scientific.net/kem.330-332.1425
- Viennot, S., Dalard, F., Malquarti, G., & Grosgogeat, B. (2006). Combination fixed and removable prostheses using a CoCr alloy: A clinical report. The Journal of Prosthetic Dentistry, 96(2), 100–103. https://doi.org/10.1016/j.prosdent.2006.04.013