Published July 23, 2018 | Journal article | Version v1 | https://doi.org/10.1515/iss-2018-0017

Dehydration improves biomechanical strength of bioartificial vascular graft material and allows its long-term storage

Description

AbstractIntroductionWe have recently reported about a novel technique for the generation of bioartificial vascular grafts based on the use of a compacted fibrin matrix. In this study, we evaluated the effects of a dehydration process on the biomechanical properties of compacted fibrin tubes and whether it allows for their long-term storage.Materials and methodsFibrin was precipitated from fresh frozen plasma by means of cryoprecipitation and simultaneously with a thrombin solution applied in a high-speed rotating casting mold. Subsequent dehydration of the fibrin tubes (29/38) was performed in dry air with a dilator inside the tube to prevent the collapse of the lumen. Dehydrated fibrin tubes were stored for six (n=9) and 12 months (n=10) at room temperature. Comparative analysis was done on initially generated and dehydrated fibrin tubes before and after storage to evaluate the effects of the dehydration process and storage on the biomechanical properties and structure of the tubes.ResultsThirty-eight fibrin tubes were generated by high-speed rotation-molding from 142±3 mg fibrinogen with an inner diameter of 5.8±0.1 mm and a length of 100 mm. A centrifugal force of nearly 900×gcompacted applied fibrin, while fluid was pressed out of the matrix and drained from the mold via holes resulting in a 16-fold compaction of the fibrin matrix. Dehydration was characterized by shrinkage of the tubes to a diameter of 3.2±0.2 mm, while the length remained at 100 mm equivalent to a further two-fold compaction. The biomechanical strength of the dehydrated fibrin tubes significantly increased to values comparable to that of native ovine carotid arteries and maintained during the first 6 months of storage. After 12 months of storage, only five of 10 tubes were intact, and only one showed maintained biomechanical strength.DiscussionCompaction of a fibrin matrix in high-speed rotation-moulding and subsequent dehydration enables for the construction of small-caliber fibrin grafts. Over and above, the dehydration process allows their storage and stockpiling as a prerequisite for clinical use.

Additional details

Dates

Issued
July 23, 2018

References

  1. Cameron, A., Davis, K. B., Green, G., & Schaff, H. V. (1996). Coronary Bypass Surgery with Internal-Thoracic-Artery Grafts — Effects on Survival over a 15-Year Period. New England Journal of Medicine, 334(4), 216–220. https://doi.org/10.1056/nejm199601253340402
  2. Oversized biodegradable arterial grafts promote enhanced neointimal tissue formation.
  3. Long, J. L., & Tranquillo, R. T. (2003). Elastic fiber production in cardiovascular tissue-equivalents. Matrix Biology, 22(4), 339–350. https://doi.org/10.1016/s0945-053x(03)00052-0
  4. Niklason, L. E. (1999). Replacement Arteries Made to Order. Science, 286(5444), 1493–1494. https://doi.org/10.1126/science.286.5444.1493
  5. Tschoeke, B., Flanagan, T. C., Cornelissen, A., Koch, S., Roehl, A., Sriharwoko, M., Sachweh, J. S., Gries, T., Schmitz‐Rode, T., & Jockenhoevel, S. (2008). Development of a Composite Degradable/Nondegradable Tissue‐engineered Vascular Graft. Artificial Organs, 32(10), 800–809. https://doi.org/10.1111/j.1525-1594.2008.00601.x
  6. Niklason, L. E. (1999). Replacement Arteries Made to Order. Science, 286(5444), 1493–1494. https://doi.org/10.1126/science.286.5444.1493
  7. Murphy, C. M., Haugh, M. G., & O'Brien, F. J. (2010). The effect of mean pore size on cell attachment, proliferation and migration in collagen–glycosaminoglycan scaffolds for bone tissue engineering. Biomaterials, 31(3), 461–466. https://doi.org/10.1016/j.biomaterials.2009.09.063
  8. Samson, R. H., Morales, R., Showalter, D. P., Lepore, M. R., & Nair, D. G. (2016). Heparin-bonded expanded polytetrafluoroethylene femoropopliteal bypass grafts outperform expanded polytetrafluoroethylene grafts without heparin in a long-term comparison. Journal of Vascular Surgery, 64(3), 638–647. https://doi.org/10.1016/j.jvs.2016.03.414
  9. Aper, T., Wilhelmi, M., Hoeffler, K., Benecke, N., & Haverich, A. (2016). Engineering of small diameter tubular compacted fibrin matrices. BioNanoMaterials, 17(1-2), 13–17. https://doi.org/10.1515/bnm-2015-0029
  10. Aper, T., Wilhelmi, M., Gebhardt, C., Hoeffler, K., Benecke, N., Hilfiker, A., & Haverich, A. (2016). Novel method for the generation of tissue-engineered vascular grafts based on a highly compacted fibrin matrix. Acta Biomaterialia, 29, 21–32. https://doi.org/10.1016/j.actbio.2015.10.012
  11. Klinkert, P., van Dijk, P. J. E., & Breslau, P. J. (2003). Polytetrafluoroethylene Femorotibial Bypass Grafting: 5-year Patency and Limb Salvage. Annals of Vascular Surgery, 17(5), 486–491. https://doi.org/10.1007/s10016-003-0036-8
  12. Aper, T., Teebken, O. E., Steinhoff, G., & Haverich, A. (2004). Use of a Fibrin Preparation in the Engineering of a Vascular Graft Model. European Journal of Vascular and Endovascular Surgery, 28(3), 296–302. https://doi.org/10.1016/j.ejvs.2004.05.016
  13. Tschoeke, B., Flanagan, T. C., Cornelissen, A., Koch, S., Roehl, A., Sriharwoko, M., Sachweh, J. S., Gries, T., Schmitz‐Rode, T., & Jockenhoevel, S. (2008). Development of a Composite Degradable/Nondegradable Tissue‐engineered Vascular Graft. Artificial Organs, 32(10), 800–809. https://doi.org/10.1111/j.1525-1594.2008.00601.x
  14. Heart disease and stroke statistics–2010 update: a report from the American Heart Association
  15. Aper, Haverich, & Teebken. (2009). New developments in tissue engineering of vascular prosthetic grafts. Vasa, 38(2), 99–122. https://doi.org/10.1024/0301-1526.38.2.99
  16. Drury, P. J., Olsen, E. G., & Ross, D. N. (1982). Morphological assessment of sucrose preservation for porcine heart valves. Thorax, 37(6), 466–471. https://doi.org/10.1136/thx.37.6.466
  17. Klinkert, P., van Dijk, P. J. E., & Breslau, P. J. (2003). Polytetrafluoroethylene Femorotibial Bypass Grafting: 5-year Patency and Limb Salvage. Annals of Vascular Surgery, 17(5), 486–491. https://doi.org/10.1007/s10016-003-0036-8
  18. Aper, T., Wilhelmi, M., Hoeffler, K., Benecke, N., & Haverich, A. (2016). Engineering of small diameter tubular compacted fibrin matrices. BioNanoMaterials, 17(1-2), 13–17. https://doi.org/10.1515/bnm-2015-0029
  19. Aper, T., Teebken, O., Krüger, A., Heisterkamp, A., Hilfiker, A., & Haverich, A. (2013). Development of Implantable Autologous Small-Calibre Vascular Grafts from Peripheral Blood Samples. Zentralblatt für Chirurgie - Zeitschrift für Allgemeine, Viszeral-, Thorax- und Gefäßchirurgie, 138(02), 173–179. https://doi.org/10.1055/s-0032-1315112
  20. Cameron, A., Davis, K. B., Green, G., & Schaff, H. V. (1996). Coronary Bypass Surgery with Internal-Thoracic-Artery Grafts — Effects on Survival over a 15-Year Period. New England Journal of Medicine, 334(4), 216–220. https://doi.org/10.1056/nejm199601253340402
  21. Oversized biodegradable arterial grafts promote enhanced neointimal tissue formation.
  22. Heart disease and stroke statistics–2010 update: a report from the American Heart Association
  23. Klinkert, P., Post, P. N., Breslau, P. J., & van Bockel, J. H. (2004). Saphenous Vein Versus PTFE for Above-Knee Femoropopliteal Bypass. A Review of the Literature. European Journal of Vascular and Endovascular Surgery, 27(4), 357–362. https://doi.org/10.1016/j.ejvs.2003.12.027
  24. Klinkert, P., Post, P. N., Breslau, P. J., & van Bockel, J. H. (2004). Saphenous Vein Versus PTFE for Above-Knee Femoropopliteal Bypass. A Review of the Literature. European Journal of Vascular and Endovascular Surgery, 27(4), 357–362. https://doi.org/10.1016/j.ejvs.2003.12.027
  25. Long, J. L., & Tranquillo, R. T. (2003). Elastic fiber production in cardiovascular tissue-equivalents. Matrix Biology, 22(4), 339–350. https://doi.org/10.1016/s0945-053x(03)00052-0
  26. Lau, S., Eicke, D., Carvalho Oliveira, M., Wiegmann, B., Schrimpf, C., Haverich, A., Blasczyk, R., Wilhelmi, M., Figueiredo, C., & Böer, U. (2018). Low Immunogenic Endothelial Cells Maintain Morphological and Functional Properties Required for Vascular Tissue Engineering. Tissue Engineering Part A, 24(5-6), 432–447. https://doi.org/10.1089/ten.tea.2016.0541
  27. Murphy, C. M., Haugh, M. G., & O'Brien, F. J. (2010). The effect of mean pore size on cell attachment, proliferation and migration in collagen–glycosaminoglycan scaffolds for bone tissue engineering. Biomaterials, 31(3), 461–466. https://doi.org/10.1016/j.biomaterials.2009.09.063
  28. Aper, T., Wilhelmi, M., Gebhardt, C., Hoeffler, K., Benecke, N., Hilfiker, A., & Haverich, A. (2016). Novel method for the generation of tissue-engineered vascular grafts based on a highly compacted fibrin matrix. Acta Biomaterialia, 29, 21–32. https://doi.org/10.1016/j.actbio.2015.10.012
  29. Böer, U., Spengler, C., Jonigk, D., Klingenberg, M., Schrimpf, C., Lützner, S., Harder, M., Kreipe, H.-H., Haverich, A., & Wilhelmi, M. (2013). Coating Decellularized Equine Carotid Arteries with CCN1 Improves Cellular Repopulation, Local Biocompatibility, and Immune Response in Sheep. Tissue Engineering Part A, 19(15-16), 1829–1842. https://doi.org/10.1089/ten.tea.2012.0558
  30. Samson, R. H., Morales, R., Showalter, D. P., Lepore, M. R., & Nair, D. G. (2016). Heparin-bonded expanded polytetrafluoroethylene femoropopliteal bypass grafts outperform expanded polytetrafluoroethylene grafts without heparin in a long-term comparison. Journal of Vascular Surgery, 64(3), 638–647. https://doi.org/10.1016/j.jvs.2016.03.414
  31. Goh, E., Wong, E., Farhatnia, Y., Tan, A., & Seifalian, A. (2014). Accelerating in Situ Endothelialisation of Cardiovascular Bypass Grafts. International Journal of Molecular Sciences, 16(1), 597–627. https://doi.org/10.3390/ijms16010597
  32. Sarkar, S., Schmitz-Rixen, T., Hamilton, G., & Seifalian, A. M. (2007). Achieving the ideal properties for vascular bypass grafts using a tissue engineered approach: a review. Medical & Biological Engineering & Computing, 45(4), 327–336. https://doi.org/10.1007/s11517-007-0176-z
  33. Böer, U., Spengler, C., Jonigk, D., Klingenberg, M., Schrimpf, C., Lützner, S., Harder, M., Kreipe, H.-H., Haverich, A., & Wilhelmi, M. (2013). Coating Decellularized Equine Carotid Arteries with CCN1 Improves Cellular Repopulation, Local Biocompatibility, and Immune Response in Sheep. Tissue Engineering Part A, 19(15-16), 1829–1842. https://doi.org/10.1089/ten.tea.2012.0558
  34. ANGELINI, G. D., & NEWBY, A. C. (1989). The future of saphenous vein as a coronary artery bypass conduit. European Heart Journal, 10(3), 273–280. https://doi.org/10.1093/oxfordjournals.eurheartj.a059476
  35. Evaluation of autologous tissue sources for the isolation of endothelial cells and adipose tissue-derived mesenchymal stem cells to pre-vascularize tissue-engineered vascular grafts
  36. Cleary, M. A., Geiger, E., Grady, C., Best, C., Naito, Y., & Breuer, C. (2012). Vascular tissue engineering: the next generation. Trends in Molecular Medicine, 18(7), 394–404. https://doi.org/10.1016/j.molmed.2012.04.013
  37. Chiu, K. W. H., Davies, R. S. M., Nightingale, P. G., Bradbury, A. W., & Adam, D. J. (2010). Review of Direct Anatomical Open Surgical Management of Atherosclerotic Aorto-Iliac Occlusive Disease. European Journal of Vascular and Endovascular Surgery, 39(4), 460–471. https://doi.org/10.1016/j.ejvs.2009.12.014
  38. Aper, T., Teebken, O. E., Steinhoff, G., & Haverich, A. (2004). Use of a Fibrin Preparation in the Engineering of a Vascular Graft Model. European Journal of Vascular and Endovascular Surgery, 28(3), 296–302. https://doi.org/10.1016/j.ejvs.2004.05.016
  39. Chiu, K. W. H., Davies, R. S. M., Nightingale, P. G., Bradbury, A. W., & Adam, D. J. (2010). Review of Direct Anatomical Open Surgical Management of Atherosclerotic Aorto-Iliac Occlusive Disease. European Journal of Vascular and Endovascular Surgery, 39(4), 460–471. https://doi.org/10.1016/j.ejvs.2009.12.014
  40. Aper, Haverich, & Teebken. (2009). New developments in tissue engineering of vascular prosthetic grafts. Vasa, 38(2), 99–122. https://doi.org/10.1024/0301-1526.38.2.99
  41. Lau, S., Eicke, D., Carvalho Oliveira, M., Wiegmann, B., Schrimpf, C., Haverich, A., Blasczyk, R., Wilhelmi, M., Figueiredo, C., & Böer, U. (2018). Low Immunogenic Endothelial Cells Maintain Morphological and Functional Properties Required for Vascular Tissue Engineering. Tissue Engineering Part A, 24(5-6), 432–447. https://doi.org/10.1089/ten.tea.2016.0541
  42. Drury, P. J., Olsen, E. G., & Ross, D. N. (1982). Morphological assessment of sucrose preservation for porcine heart valves. Thorax, 37(6), 466–471. https://doi.org/10.1136/thx.37.6.466
  43. Goh, E., Wong, E., Farhatnia, Y., Tan, A., & Seifalian, A. (2014). Accelerating in Situ Endothelialisation of Cardiovascular Bypass Grafts. International Journal of Molecular Sciences, 16(1), 597–627. https://doi.org/10.3390/ijms16010597
  44. Aper, T., Teebken, O., Krüger, A., Heisterkamp, A., Hilfiker, A., & Haverich, A. (2013). Development of Implantable Autologous Small-Calibre Vascular Grafts from Peripheral Blood Samples. Zentralblatt für Chirurgie - Zeitschrift für Allgemeine, Viszeral-, Thorax- und Gefäßchirurgie, 138(02), 173–179. https://doi.org/10.1055/s-0032-1315112
  45. Cleary, M. A., Geiger, E., Grady, C., Best, C., Naito, Y., & Breuer, C. (2012). Vascular tissue engineering: the next generation. Trends in Molecular Medicine, 18(7), 394–404. https://doi.org/10.1016/j.molmed.2012.04.013
  46. Evaluation of autologous tissue sources for the isolation of endothelial cells and adipose tissue-derived mesenchymal stem cells to pre-vascularize tissue-engineered vascular grafts
  47. ANGELINI, G. D., & NEWBY, A. C. (1989). The future of saphenous vein as a coronary artery bypass conduit. European Heart Journal, 10(3), 273–280. https://doi.org/10.1093/oxfordjournals.eurheartj.a059476
  48. Sarkar, S., Schmitz-Rixen, T., Hamilton, G., & Seifalian, A. M. (2007). Achieving the ideal properties for vascular bypass grafts using a tissue engineered approach: a review. Medical & Biological Engineering & Computing, 45(4), 327–336. https://doi.org/10.1007/s11517-007-0176-z