Skip to main
Determination of the acylcoenzyme A cholesterol acyltransferase inhibitor 447C88 in plasma using gas chromatography-mass spectrometry and liquid chromatography atmospheric pressure chemical ionisation tandem mass spectrometry
Additional details
-
Martin, M., Browner, W., Hulley, S., Kuller, L., & Wentworth, D. (1986). SERUM CHOLESTEROL, BLOOD PRESSURE, AND MORTALITY: IMPLICATIONS FROM A COHORT OF 361 662 MEN. The Lancet, 328(8513), 933–936.
https://doi.org/10.1016/s0140-6736(86)90597-0
-
Morris, M. J., Gilbert, J. D., Hsieh, J. Y.-K., Matuszewski, B. K., Ramjit, H. G., & Bayne, W. F. (1993). Determination of the HMG-CoA reductase inhibitors simvastatin, lovastatin, and pravastatin in plasma by gas chromatography/chemical ionization mass spectrometry. Biological Mass Spectrometry, 22(1), 1–8.
https://doi.org/10.1002/bms.1200220102
-
Takano, T., Abe, S., & Hata, S. (1990). A selected ion monitoring method for quantifying simvastatin and its acid form in human plasma, using the ferroceneboronate derivative. Biological Mass Spectrometry, 19(9), 577–581.
https://doi.org/10.1002/bms.1200190910
-
Wang‐Iverson, D., Ivashkiv, E., Jemal, M., & Cohen, A. I. (1989). Determination of lovastatin acid in serum by gas chromatography/mass spectrometry. Rapid Communications in Mass Spectrometry, 3(5), 132–134.
https://doi.org/10.1002/rcm.1290030504
-
Funke, P. T., Ivashkiv, E., Arnold, M. E., & Cohen, A. I. (1989). Determination of pravastatin sodium and its major metabolites in human serum/plasma by capillary gas chromatography/negative ion chemical ionization mass spectrometry. Biological Mass Spectrometry, 18(10), 904–909.
https://doi.org/10.1002/bms.1200181010
-
Grob, K. (1981). Evaluation of capillary gas chromatography for thermolabile phenylurea herbicides. Journal of Chromatography A, 208(2), 217–229.
https://doi.org/10.1016/s0021-9673(00)81933-0
-
Wachs, T., Conboy, J. C., Garcia, F., & Henion, J. D. (1991). Liquid Chromatography-Mass Spectrometry and Related Techniques via Atmospheric Pressure Ionization. Journal of Chromatographic Science, 29(8), 357–366.
https://doi.org/10.1093/chromsci/29.8.357
-
Kaye, B., Clark, M. W. H., Cussans, N. J., Macrae, P. V., & Stopher, D. A. (1992). The sensitive determination of abanoquil in blood by high-performance liquid chromatography/atmospheric pressure ionization mass spectrometry. Biological Mass Spectrometry, 21(11), 585–589.
https://doi.org/10.1002/bms.1200211110
-
Gilbert, J. D., Hand, E. L., Yuan, A. S., Olah, T. V., & Covey, T. R. (1992). Determination of L-365,260, a new cholecystokinin receptor (CCK-B) antagonist, in plasma by liquid chromatography/atmospheric pressure chemical ionization mass spectrometry. Biological Mass Spectrometry, 21(2), 63–68.
https://doi.org/10.1002/bms.1200210202
-
Morris, M. J., Gilbert, J. D., Hsieh, J. Y.-K., Matuszewski, B. K., Ramjit, H. G., & Bayne, W. F. (1993). Determination of the HMG-CoA reductase inhibitors simvastatin, lovastatin, and pravastatin in plasma by gas chromatography/chemical ionization mass spectrometry. Biological Mass Spectrometry, 22(1), 1–8.
https://doi.org/10.1002/bms.1200220102
-
Sun, S., Gao, Y., Ling, X., & Lou, H. (2005). The combination effects of phenolic compounds and fluconazole on the formation of ergosterol in Candida albicans determined by high-performance liquid chromatography/tandem mass spectrometry. Analytical Biochemistry, 336(1), 39–45.
https://doi.org/10.1016/j.ab.2004.06.038
-
Toh, T. H., Prior, B. A., & van der Merwe, M. J. (2001). Quantification of Plasma Membrane Ergosterol of Saccharomyces cerevisiae by Direct-Injection Atmospheric Pressure Chemical Ionization/Tandem Mass Spectrometry. Analytical Biochemistry, 288(1), 44–51.
https://doi.org/10.1006/abio.2000.4877
-
Plumb, R. S., Dear, G. J., Mallett, D. N., Higton, D. M., Pleasance, S., & Biddlecombe, R. A. (2001). Quantitative analysis of pharmaceuticals in biological fluids using high-performance liquid chromatography coupled to mass spectrometry: a review. Xenobiotica, 31(8-9), 599–617.
https://doi.org/10.1080/00498250110060941
-
Plumb, R. S., Dear, G. J., Mallett, D., Fraser, I. J., Ayrton, J., & Ioannou, C. (1999). The application of fast gradient capillary liquid chromatography/mass spectrometry to the analysis of pharmaceuticals in biofluids. Rapid Communications in Mass Spectrometry, 13(10), 865–872.
https://doi.org/10.1002/(sici)1097-0231(19990530)13:10%3c865::aid-rcm570%3e3.0.co;2-0
-
Maurer, H. H. (1998). Liquid chromatography–mass spectrometry in forensic and clinical toxicology. Journal of Chromatography B: Biomedical Sciences and Applications, 713(1), 3–25.
https://doi.org/10.1016/s0378-4347(97)00514-8
-
van der Hoeven, R. A. M., Hofte, A. J. P., Frenay, M., Irth, H., Tjaden, U. R., van der Greef, J., Rudolphi, A., Boos, K.-S., Varga, G. M., & Edholm, L. E. (1997). Liquid chromatography—mass spectrometry with on-line solid-phase extraction by a restricted-access C18 precolumn for direct plasma and urine injection. Journal of Chromatography A, 762(1-2), 193–200.
https://doi.org/10.1016/s0021-9673(96)01004-7