Published April 4, 2012 | Journal article | Version v1 | https://doi.org/10.1007/s00167-012-1986-6

Femoro‐tibial kinematics after TKA in fixed‐ and mobile‐bearing knees in the sagittal plane

Description

AbstractPurposeLack of the anterior cruciate ligament in total knee arthroplasty results in paradoxical movement of the femur as opposed to the tibia under deep flexion. Total knee arthroplasty with mobile‐bearing inlays has been developed to provide increased physiological movement of the knee joint and to reduce polyethylene abrasion. The aim of this study was to perform an in vitro analysis of the kinematic movement in the sagittal plane in order to show differences between fixed‐ and mobile‐bearing TKA in comparison with the natural knee joint.MethodsSeven knee joints of human cadaver material were used in a laboratory experiment. Fixed‐ and mobile‐bearing inlays were tested in sequences under isokinetic extension in so‐called kinemator for knee joints, which can simulate muscular traction power by the use of hydraulic cylinders, which crossover the knee joint. As a target parameter, the a.p. translation of the tibio‐femoral relative movement was measured in the sagittal plane under ultrasound (Zebris) control.ResultsThe results show a reduced tibial a.p. translation in relation to the femur in the bearing group compared to the natural joint. In the Z‐axis, between 110° and 50° of flexion, linear movement decreases towards caudal movement under extension. Admittedly, the study did not show differences in the movement pattern between "mobile‐bearing" and "fixed‐bearing" prostheses.ConclusionResults of this study cannot prove functional advantages of mobile‐bearing prostheses for the knee joint kinematic after TKA. Both types of prostheses show typical kinematics of an anterior instability, hence they were incapable of performing physiological movement.

Additional details

Dates

Issued
April 4, 2012

References

  1. Bhan, S. (2005). A Comparison of Fixed-Bearing and Mobile-Bearing Total Knee Arthroplasty at a Minimum Follow-up of 4.5 Years. The Journal of Bone and Joint Surgery (American), 87(10), 2290. https://doi.org/10.2106/jbjs.d.02221
  2. https://doi.org/10.1007/s11999%E2%80%90008%E2%80%900440%E2%80%90z https://doi.org/10.1007/s11999%E2%80%90008%E2%80%900440%E2%80%90z
  3. https://doi.org/10.1097/00003086%E2%80%90200011000%E2%80%9000020 https://doi.org/10.1097/00003086%E2%80%90200011000%E2%80%9000020
  4. Daniilidis, K., Skwara, A., Vieth, V., Fuchs-Winkelmann, S., Heindel, W., Stückmann, V., & Tibesku, C. O. (2012). Highly conforming polyethylene inlays reduce the in vivo variability of knee joint kinematics after total knee arthroplasty. The Knee, 19(4), 260–265. https://doi.org/10.1016/j.knee.2011.04.001
  5. https://doi.org/10.1007/s00167%E2%80%90010%E2%80%901320%E2%80%900 https://doi.org/10.1007/s00167%E2%80%90010%E2%80%901320%E2%80%900
  6. Hoff, W. A., Komistek, R. D., Dennis, D. A., Gabriel, S. M., & Walker, S. A. (1998). Three-dimensional determination of femoral-tibial contact positions under in vivo conditions using fluoroscopy. Clinical Biomechanics, 13(7), 455–472. https://doi.org/10.1016/s0268-0033(98)00009-6
  7. Knee kinematics in genesis total knee arthroplasty. A comparison of different tibial designs with and without posterior cruciate substitution in cadaveric specimens
  8. https://doi.org/10.1007/s00167%E2%80%90011%E2%80%901750%E2%80%903 https://doi.org/10.1007/s00167%E2%80%90011%E2%80%901750%E2%80%903
  9. https://doi.org/10.1007/s00167%E2%80%90009%E2%80%900883%E2%80%900 https://doi.org/10.1007/s00167%E2%80%90009%E2%80%900883%E2%80%900
  10. https://doi.org/10.1016/s0883%E2%80%905403(97)90008%E2%80%905 https://doi.org/10.1016/s0883%E2%80%905403(97)90008%E2%80%905
  11. Liu, W., & Maitland, M. E. (2003). Influence of Anthropometric and Mechanical Variations on Functional Instability in the ACL-Deficient Knee. Annals of Biomedical Engineering, 31(10), 1153–1161. https://doi.org/10.1114/1.1615572
  12. https://doi.org/10.1007/s00167%E2%80%90010%E2%80%901143%E2%80%90z https://doi.org/10.1007/s00167%E2%80%90010%E2%80%901143%E2%80%90z
  13. Mechanical evaluation of mobile bearing knees
  14. Most, E., Li, G., Schule, S., Sultan, P., Park, S. E., Zayontz, S., & Rubash, H. E. (2003). The Kinematics of Fixed- and Mobile-Bearing Total Knee Arthroplasty. Clinical Orthopaedics & Related Research, 416, 197–207. https://doi.org/10.1097/01.blo.0000092999.90435.d1
  15. https://doi.org/10.1007/s00132%E2%80%90002%E2%80%900438%E2%80%902 https://doi.org/10.1007/s00132%E2%80%90002%E2%80%900438%E2%80%902
  16. Ostermeier, S., Schlomach, C., Hurschler, C., Windhagen, H., & Stukenborg-Colsman, C. (2006). Dynamic in vitro measurement of posterior cruciate ligament load and tibiofemoral stress after TKA in dependence on tibiofemoral slope. Clinical Biomechanics, 21(5), 525–532. https://doi.org/10.1016/j.clinbiomech.2005.12.019
  17. Post, Z. D., Matar, W. Y., van de Leur, T., Grossman, E. L., & Austin, M. S. (2010). Mobile-Bearing Total Knee Arthroplasty. The Journal of Arthroplasty, 25(6), 998–1003. https://doi.org/10.1016/j.arth.2009.07.014
  18. Siebel, T., & Käfer, W. (2004). Modification of the posterior cruciate ligament tension following total knee arthroplasty: comparison of the Genesis CR and LCS meniscal bearing prostheses. The Knee, 11(3), 203–208. https://doi.org/10.1016/j.knee.2003.07.001
  19. https://doi.org/10.1007/s00402%E2%80%90008%E2%80%900757%E2%80%909 https://doi.org/10.1007/s00402%E2%80%90008%E2%80%900757%E2%80%909
  20. https://doi.org/10.1007/s00167%E2%80%90009%E2%80%900909%E2%80%907 https://doi.org/10.1007/s00167%E2%80%90009%E2%80%900909%E2%80%907
  21. https://doi.org/10.1097/00003086%E2%80%90199712000%E2%80%9000010 https://doi.org/10.1097/00003086%E2%80%90199712000%E2%80%9000010
  22. https://doi.org/10.1007/s00132%E2%80%90002%E2%80%900442%E2%80%906 https://doi.org/10.1007/s00132%E2%80%90002%E2%80%900442%E2%80%906
  23. Stukenborg-Colsman, C., Ostermeier, S., Hurschler, C., & Wirth, C.-J. (2000). Knee endoprosthesis. Biomechanical requirements and consequences. Der Orthopäde, 29(8), 722–726. https://doi.org/10.1007/s001320050517
  24. Stukenborg-Colsman, C., Ostermeier, S., Hurschler, C., & Wirth, C. J. (2002). Tibiofemoral contact stress after total knee arthroplasty: Comparison of fixed and mobile-bearing inlay designs. Acta Orthopaedica Scandinavica, 73(6), 638–646. https://doi.org/10.1080/000164702321039598
  25. Stukenborg-Colsman, C., Ostermeier, S., Wenger, K. H., & Wirth, C. J. (2002). Relative motion of a mobile bearing inlay after total knee arthroplasty – dynamic in vitro study. Clinical Biomechanics, 17(1), 49–55. https://doi.org/10.1016/s0268-0033(01)00103-6

1–25 of 29

Citations

  1. https://doi.org/10.70675/0507bedczfd4fz4210z8ffaz88262aad6a34
  2. https://doi.org/10.1302/0301-620x.100b7.bjj-2017-1473.r1
  3. Steinbrück, A., Schröder, C., Woiczinski, M., Glogaza, A., Müller, P. E., Jansson, V., & Fottner, A. (2017). A lateral retinacular release during total knee arthroplasty changes femorotibial kinematics: an in vitro study. Archives of Orthopaedic and Trauma Surgery, 138(3), 401–407. https://doi.org/10.1007/s00402-017-2843-3
  4. Saxena, V., Anari, J. B., Ruutiainen, A. T., Voleti, P. B., Stephenson, J. W., & Lee, G.-C. (2016). Tibial component considerations in bicruciate-retaining total knee arthroplasty: A 3D MRI evaluation of proximal tibial anatomy. The Knee, 23(4), 593–599. https://doi.org/10.1016/j.knee.2015.12.002
  5. Ettinger, M., Zoch, J. M., Becher, C., Hurschler, C., Stukenborg-Colsman, C., Claassen, L., Ostermeier, S., & Calliess, T. (2015). In vitro kinematics of fixed versus mobile bearing in unicondylar knee arthroplasty. Archives of Orthopaedic and Trauma Surgery, 135(6), 871–877. https://doi.org/10.1007/s00402-015-2214-x
  6. Guglielmetti, L. G. B., Costa, P. P. da ., Cury, R. de P. L., Oliveira, V. M. de ., Severino, N. R., & Camargo, O. P. A. de . (2015). Artroplastia total do joelho com o apoio tibial móvel. Avaliação clínica após seguimento mínimo de cinco anos de pós‐operatório. Revista Brasileira de Ortopedia, 50(3), 290–294. https://doi.org/10.1016/j.rbo.2014.05.008
  7. Guglielmetti, L. G. B., da Costa, P. P., de Paula Leite Cury, R., de Oliveira, V. M., Severino, N. R., & de Camargo, O. P. A. (2015). Total knee arthroplasty with mobile tibial weight-bearing: clinical evaluation after a minimum of five years of postoperative follow-up. Revista Brasileira De Ortopedia (English Edition), 50(3), 290–294. https://doi.org/10.1016/j.rboe.2015.05.004
  8. Urwin, S. G., Kader, D. F., Caplan, N., St Clair Gibson, A., & Stewart, S. (2014). Gait analysis of fixed bearing and mobile bearing total knee prostheses during walking: Do mobile bearings offer functional advantages?. The Knee, 21(2), 391–395. https://doi.org/10.1016/j.knee.2013.10.007