Published February 2015 | Journal article | Version v1 | https://doi.org/10.1007/s12350-014-9994-1

The importance of a correct positioning of the heart using IQ-SPECT system with multifocal collimators in myocardial perfusion imaging: A phantom study

Additional details

Dates

Issued
February 2015

References

  1. Garcia, E. V., Faber, T. L., & Esteves, F. P. (2011). Cardiac Dedicated Ultrafast SPECT Cameras: New Designs and Clinical Implications. Journal of Nuclear Medicine, 52(2), 210–217. https://doi.org/10.2967/jnumed.110.081323
  2. Pizzocaro, C., Paghera, B., Guerra, U. P., & Caobelli, F. (2013). Evaluation of patients with coronary artery disease. Nuklearmedizin, 52(05), 178–185. https://doi.org/10.3413/nukmed-0570-13-03
  3. Rajaram, R., Bhattacharya, M., Ding, X., Malmin, R., Rempel, T. D., Vija, A. H., & Zeintl, J. (2011). Tomographic performance characteristics of the IQ●SPECT system. 2011 IEEE Nuclear Science Symposium Conference Record, 2451–2456. https://doi.org/10.1109/nssmic.2011.6152666
  4. Technetium-99m-1,2-bis[bis(2-ethoxyethyl)phosphino]ethane: Human biodistribution, dosimetry and safety of a new myocardial perfusion imaging agent
  5. Zoccarato, O., Scabbio, C., De Ponti, E., Matheoud, R., Leva, L., Morzenti, S., Menzaghi, M., Campini, R., Marcassa, C., Del Sole, A., Garancini, S., Crivellaro, C., Brambilla, M., & Lecchi, M. (2014). Comparative analysis of iterative reconstruction algorithms with resolution recovery for cardiac SPECT studies. A multi-center phantom study. Journal of Nuclear Cardiology, 21(1), 135–148. https://doi.org/10.1007/s12350-013-9821-0
  6. Rasband WS. ImageJ. Bethesda, MD: U. S. National Institutes of Health; 1997-2012. https://imagej.nih.gov/ij
  7. Imbert, L., Poussier, S., Franken, P. R., Songy, B., Verger, A., Morel, O., Wolf, D., Noel, A., Karcher, G., & Marie, P.-Y. (2012). Compared Performance of High-Sensitivity Cameras Dedicated to Myocardial Perfusion SPECT: A Comprehensive Analysis of Phantom and Human Images. Journal of Nuclear Medicine, 53(12), 1897–1903. https://doi.org/10.2967/jnumed.112.107417
  8. Dong, X., Niu, T., Jia, X., & Zhu, L. (2012). Relationship between x‐ray illumination field size and flat field intensity and its impacts on x‐ray imaging. Medical Physics, 39(10), 5901–5909. https://doi.org/10.1118/1.4750054
  9. Hindorf, C., Oddstig, J., Hedeer, F., Hansson, M. J., Jögi, J., & Engblom, H. (2014). Importance of correct patient positioning in myocardial perfusion SPECT when using a CZT camera. Journal of Nuclear Cardiology, 21(4), 695–702. https://doi.org/10.1007/s12350-014-9897-1

Citations

  1. Azimi, M. S., Karakatsanis, N. A., Sabet, H., Rafecas, M., Nehmeh, S., Alavi, A., King, M., & Zaidi, H. (2026). Instrumentation Digital Twins in PET and SPECT Imaging: Current Status, Challenges, and Future Directions. Computational and Structural Biotechnology Journal, 35(1). https://doi.org/10.34133/csbj.0046
  2. Dundara Debeljuh, D., Matheoud, R., Zoccarato, O., Pribanić, I., Brambilla, M., & Jurković, S. (2024). Characterization of myocardial perfusion imaging systems - an extension of quality metrics. Physica Medica, 125, Article 104510. https://doi.org/10.1016/j.ejmp.2024.104510
  3. Dundara Debeljuh, D., Matheoud, R., Pribanić, I., Brambilla, M., & Jurković, S. (2024). Evaluation of Single-Photon Emission Computed Tomography Myocardial Perfusion Detection Capability through Physical Descriptors. Applied Sciences, 14(12), 5283. https://doi.org/10.3390/app14125283
  4. Krizsan, A. K., Kukuts, K., Al-Muhanna, W., Szoboszlai, Z., Balazs, L., Szabo, B., Kiss, J., Nekolla, S., Barna, S., Garai, I., Bukki, T., & Forgacs, A. (2023). Performance evaluation of a novel multi-pinhole collimator on triple-NaI-detector SPECT/CT for dedicated myocardial imaging. EJNMMI Physics, 10(1). https://doi.org/10.1186/s40658-023-00541-y
  5. Mendoza-Ibañez, O. I., Martínez-Lucio, T. S., Alexanderson-Rosas, E., & Slart, R. H. J. A. (2022). SPECT in Ischemic Heart Diseases. In Nuclear Medicine and Molecular Imaging (pp. 120–136). Elsevier. https://doi.org/10.1016/b978-0-12-822960-6.00015-6
  6. Krizsan, A. K., Kukuts, K., Al-Muhanna, W., Szoboszlai, Z., Balazs, L., Szabo, B., Kiss, J., Nekolla, S., Barna, S., Bukki, T., & Forgacs, A. (2022). Performance Evaluation of a Novel Multi-PinHole Collimator on Triple-detector SPECT/CT for dedicated myocardial imaging. In Research Square. Springer Science and Business Media LLC. https://doi.org/10.21203/rs.3.rs-1978057/v1
  7. Khalil, M. M. (2021). Elements of Gamma Camera and SPECT Systems. In Basic Sciences of Nuclear Medicine (pp. 231–257). Springer International Publishing. https://doi.org/10.1007/978-3-030-65245-6_10
  8. Leva, L., Matheoud, R., Sacchetti, G., Carriero, A., & Brambilla, M. (2020). Agreement between left ventricular ejection fraction assessed in patients with gated IQ-SPECT and conventional imaging. Journal of Nuclear Cardiology, 27(5), 1714–1724. https://doi.org/10.1007/s12350-018-1457-7
  9. Rosenberg, R. D., & Patil, P. V. (2019). Multimodality imaging of the left ventricle: Choosing soundly. Journal of Nuclear Cardiology, 26(6), 1865–1868. https://doi.org/10.1007/s12350-018-1294-8
  10. Okuda, K., Nakajima, K., Matsuo, S., Kondo, C., Sarai, M., Horiguchi, Y., Konishi, T., Onoguchi, M., Shimizu, T., & Kinuya, S. (2018). Creation and characterization of normal myocardial perfusion imaging databases using the IQ·SPECT system. Journal of Nuclear Cardiology, 25(4), 1328–1337. https://doi.org/10.1007/s12350-016-0770-2
  11. Galt, J. R. (2018). New techniques, distinctive population, unique normal databases. Journal of Nuclear Cardiology, 25(4), 1338–1341. https://doi.org/10.1007/s12350-017-0876-1
  12. Dorbala, S., Ananthasubramaniam, K., Armstrong, I. S., Chareonthaitawee, P., DePuey, E. G., Einstein, A. J., Gropler, R. J., Holly, T. A., Mahmarian, J. J., Park, M.-A., Polk, D. M., Russell, R., Slomka, P. J., Thompson, R. C., & Wells, R. G. (2018). Single Photon Emission Computed Tomography (SPECT) Myocardial Perfusion Imaging Guidelines: Instrumentation, Acquisition, Processing, and Interpretation. Journal of Nuclear Cardiology, 25(5), 1784–1846. https://doi.org/10.1007/s12350-018-1283-y
  13. Konishi, T., Nakajima, K., Okuda, K., Yoneyama, H., Matsuo, S., Shibutani, T., Onoguchi, M., & Kinuya, S. (2017). IQ-SPECT for thallium-201 myocardial perfusion imaging: effect of normal databases on quantification. Annals of Nuclear Medicine, 31(6), 454–461. https://doi.org/10.1007/s12149-017-1170-7
  14. Nakajima, K., Okuda, K., Momose, M., Matsuo, S., Kondo, C., Sarai, M., Shibutani, T., Onoguchi, M., Shimizu, T., & Vija, A. H. (2017). IQ·SPECT technology and its clinical applications using multicenter normal databases. Annals of Nuclear Medicine, 31(9), 649–659. https://doi.org/10.1007/s12149-017-1210-3
  15. Erwin, W. D., Jessop, A. C., Mar, M. V., Macapinlac, H. A., & Mawlawi, O. R. (2017). Qualitative and quantitative comparison of gated blood pool single photon emission computed tomography using low-energy high-resolution and SMARTZOOM collimation. Nuclear Medicine Communications, 38(1), 35–43. https://doi.org/10.1097/mnm.0000000000000609
  16. Hippeläinen, E., Mäkelä, T., Kaasalainen, T., & Kaleva, E. (2017). Ejection fraction in myocardial perfusion imaging assessed with a dynamic phantom: comparison between IQ-SPECT and LEHR. EJNMMI Physics, 4(1). https://doi.org/10.1186/s40658-017-0187-2
  17. Yoneyama, H., Shibutani, T., Konishi, T., Mizutani, A., Hashimoto, R., Onoguchi, M., Okuda, K., Matsuo, S., Nakajima, K., & Kinuya, S. (2017). Validation of Left Ventricular Ejection Fraction with the IQ•SPECT System in Small-Heart Patients. Journal of Nuclear Medicine Technology, 45(3), 201–207. https://doi.org/10.2967/jnmt.116.188680
  18. Caobelli, F., Thackeray, J. T., Soffientini, A., Bengel, F. M., Pizzocaro, C., & Guerra, U. P. (2015). Feasibility of one-eighth time gated myocardial perfusion SPECT functional imaging using IQ-SPECT. European Journal of Nuclear Medicine and Molecular Imaging, 42(12), 1920–1928. https://doi.org/10.1007/s00259-015-3142-2
  19. Gremillet, E., & Agostini, D. (2015). How to use cardiac IQ•SPECT routinely? An overview of tips and tricks from practical experience to the literature. European Journal of Nuclear Medicine and Molecular Imaging, 43(4), 707–710. https://doi.org/10.1007/s00259-015-3269-1
  20. Matsuo, S., Nakajima, K., Onoguchi, M., Wakabayash, H., Okuda, K., & Kinuya, S. (2015). Nuclear myocardial perfusion imaging using thallium-201 with a novel multifocal collimator SPECT/CT: IQ-SPECT versus conventional protocols in normal subjects. Annals of Nuclear Medicine, 29(5), 452–459. https://doi.org/10.1007/s12149-015-0965-7
  21. Caobelli, F., Kaiser, S. R., Thackeray, J. T., Bengel, F. M., Chieregato, M., Soffientini, A., Pizzocaro, C., Savelli, G., Galelli, M., & Guerra, U. P. (2014). IQ SPECT Allows a Significant Reduction in Administered Dose and Acquisition Time for Myocardial Perfusion Imaging: Evidence from a Phantom Study. Journal of Nuclear Medicine, 55(12), 2064–2070. https://doi.org/10.2967/jnumed.114.143560