Published February 14, 2012 | Journal article | Version v1 | https://doi.org/10.1007/s00246-012-0192-0

Comparison of Transpulmonary Thermodilution and Ultrasound Dilution Technique: Novel Insights into Volumetric Parameters from an Animal Model

Additional details

Dates

Issued
February 14, 2012

References

  1. Martin Bland, J., & Altman, D. (1986). STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT. The Lancet, 327(8476), 307–310. https://doi.org/10.1016/s0140-6736(86)90837-8
  2. Brierley, J., Carcillo, J. A., Choong, K., Cornell, T., DeCaen, A., Deymann, A., Doctor, A., Davis, A., Duff, J., Dugas, M.-A., Duncan, A., Evans, B., Feldman, J., Felmet, K., Fisher, G., Frankel, L., Jeffries, H., Greenwald, B., Gutierrez, J., … Zuckerberg, A. (2009). Clinical practice parameters for hemodynamic support of pediatric and neonatal septic shock: 2007 update from the American College of Critical Care Medicine*. Critical Care Medicine, 37(2), 666–688. https://doi.org/10.1097/ccm.0b013e31819323c6
  3. Brivet, F. G., Jacobs, F., & Colin, P. (2004). Calculated global end-diastolic volume does not correspond to the largest heart blood volume: a bias for cardiac function index?. Intensive Care Medicine, 30(11), 2133–2134. https://doi.org/10.1007/s00134-004-2432-0
  4. Cecchetti, C., Lubrano, R., Cristaldi, S., Stoppa, F., Barbieri, M. A., Elli, M., Masciangelo, R., Perrotta, D., Travasso, E., Raggi, C., Marano, M., & Pirozzi, N. (2008). Relationship between global end-diastolic volume and cardiac output in critically ill infants and children*. Critical Care Medicine, 36(3), 928–932. https://doi.org/10.1097/ccm.0b013e3181653786
  5. Critchley, L. A. H., & Critchley, J. A. J. H. (1999). A Meta-Analysis of Studies Using Bias and Precision Statistics to Compare Cardiac Output Measurement Techniques. Journal of Clinical Monitoring and Computing, 15(2), 85–91. https://doi.org/10.1023/a:1009982611386
  6. Crittendon, I., Dreyer, W. J., Decker, J. A., & Kim, J. J. (2012). Ultrasound dilution. Pediatric Critical Care Medicine, 13(1), 42–46. https://doi.org/10.1097/pcc.0b013e3182196804
  7. Darling, E., Thuramalla, N., & Searles, B. (2011). Validation of Cardiac Output Measurement by Ultrasound Dilution Technique With Pulmonary Artery Thermodilution in a Pediatric Animal Model. Pediatric Cardiology, 32(5), 585–589. https://doi.org/10.1007/s00246-011-9915-x
  8. de Boode, W.-P. (2010). Cardiac output monitoring in newborns. Early Human Development, 86(3), 143–148. https://doi.org/10.1016/j.earlhumdev.2010.01.032
  9. de Boode, W. P., van Heijst, A. F. J., Hopman, J. C. W., Tanke, R. B., van der Hoeven, H. G., & Liem, K. D. (2010). Cardiac output measurement using an ultrasound dilution method: A validation study in ventilated piglets. Pediatric Critical Care Medicine, 11(1), 103–108. https://doi.org/10.1097/pcc.0b013e3181b064ea
  10. Dewey, F. E., Rosenthal, D., Murphy, D. J., Froelicher, V. F., & Ashley, E. A. (2008). Does Size Matter?. Circulation, 117(17), 2279–2287. https://doi.org/10.1161/circulationaha.107.736785
  11. DOBSON, A., & KISLUKHIN, V. V. (2004). Heart Blood Volume by Dilution in Patients on Hemodialysis. ASAIO Journal, 50(3), 278–284. https://doi.org/10.1097/01.mat.0000123636.30437.f2
  12. Egan, J. R., Festa, M., Cole, A. D., Nunn, G. R., Gillis, J., & Winlaw, D. S. (2005). Clinical assessment of cardiac performance in infants and children following cardiac surgery. Intensive Care Medicine, 31(4), 568–573. https://doi.org/10.1007/s00134-005-2569-5
  13. Galstyan, G., Bychinin, M., Alexanyan, M., & Gorodetsky, V. (2010). Comparison of cardiac output and blood volumes in intrathoracic compartments measured by ultrasound dilution and transpulmonary thermodilution methods. Intensive Care Medicine, 36(12), 2140–2144. https://doi.org/10.1007/s00134-010-2003-5
  14. GRAHAM, T. P., JARMAKANI, J. M., ATWOOD, G. F., & CANENT, R. V. (1973). Right Ventricular Volume Determinations in Children. Circulation, 47(1), 144–153. https://doi.org/10.1161/01.cir.47.1.144
  15. GRAHAM, T. P., JARMAKANI, M. M., CANENT, R. V., CAPP, M. P., & SPACH, M. S. (1968). Characterization of Left Heart Volumes and Mass in Normal Children and in Ifants with Intrinsic Myocardial Disease. Circulation, 38(5), 826–837. https://doi.org/10.1161/01.cir.38.5.826
  16. Krivitski, N. M., Kislukhin, V. V., & Thuramalla, N. V. (2008). Theory and in vitro validation of a new extracorporeal arteriovenous loop approach for hemodynamic assessment in pediatric and neonatal intensive care unit patients*. Pediatric Critical Care Medicine, 9(4), 423–428. https://doi.org/10.1097/01.pcc.0b013e31816c71bc
  17. Lemson, J., Backx, A. P., van Oort, A. M., Bouw, T. P. W. J. M., & van der Hoeven, J. G. (2009). Extravascular lung water measurement using transpulmonary thermodilution in children. Pediatric Critical Care Medicine, 10(2), 227–233. https://doi.org/10.1097/pcc.0b013e3181937227
  18. Meier, P., & Zierler, K. L. (1954). On the Theory of the Indicator-Dilution Method for Measurement of Blood Flow and Volume. Journal of Applied Physiology, 6(12), 731–744. https://doi.org/10.1152/jappl.1954.6.12.731
  19. Michard, F. (2007). Bedside assessment of extravascular lung water by dilution methods: Temptations and pitfalls. Critical Care Medicine, 35(4), 1186–1192. https://doi.org/10.1097/01.ccm.0000259539.49339.66
  20. Neumann, P. (1999). Extravascular lung water and intrathoracic blood volume: double versus single indicator dilution technique. Intensive Care Medicine, 25(2), 216–219. https://doi.org/10.1007/s001340050819
  21. NEWMAN, E. V., MERRELL, M., GENECIN, A., MONGE, C., MILNOR, W. R., & MCKEEVER, W. P. (1951). The Dye Dilution Method for Describing the Central Circulation. Circulation, 4(5), 735–746. https://doi.org/10.1161/01.cir.4.5.735
  22. Norozi, K., Beck, C., Osthaus, W. A., Wille, I., Wessel, A., & Bertram, H. (2008). Electrical velocimetry for measuring cardiac output in children with congenital heart disease. British Journal of Anaesthesia, 100(1), 88–94. https://doi.org/10.1093/bja/aem320
  23. Proulx, F., Lemson, J., Choker, G., & Tibby, S. M. (2011). Hemodynamic monitoring by transpulmonary thermodilution and pulse contour analysis in critically ill children. Pediatric Critical Care Medicine, 12(4), 459–466. https://doi.org/10.1097/pcc.0b013e3182070959
  24. Pulsion Medical Inc Irving USA (2009) PiCCO: technology, theory, and practice—Train the trainer folder US. Pulsion Medical, Irving
  25. Renner, J., Meybohm, P., Gruenewald, M., Steinfath, M., Scholz, J., Boening, A., & Bein, B. (2007). Global End-Diastolic Volume During Different Loading Conditions in a Pediatric Animal Model. Anesthesia & Analgesia, 105(5), 1243–1249. https://doi.org/10.1213/01.ane.0000281152.72734.d0

1–25 of 39

Citations

  1. Heringlake, M., Paarmann, H., Heinze, H., Groesdonk, H. V., & Brandt, S. (2024). Hämodynamisches und respiratorisches Monitoring. In Springer Reference Medizin (pp. 263–305). Springer Berlin Heidelberg. https://doi.org/10.1007/978-3-662-68699-7_21
  2. Heringlake, M., Paarmann, H., Heinze, H., Groesdonk, H. V., & Brandt, S. (2023). Hämodynamisches und respiratorisches Monitoring. In Springer Reference Medizin (pp. 1–43). Springer Berlin Heidelberg. https://doi.org/10.1007/978-3-642-54675-4_21-3
  3. https://doi.org/10.1186/s40635-023-00497-4
  4. Heringlake, M., Paarmann, H., Heinze, H., Groesdonk, H.-V., & Brandt, S. (2022). Hämodynamisches und respiratorisches Monitoring. In Springer Reference Medizin (pp. 1–43). Springer Berlin Heidelberg. https://doi.org/10.1007/978-3-642-54675-4_21-2
  5. https://doi.org/10.1186/s40635-020-00330-2
  6. Boehne, M., Baustert, M., Paetzel, V., Boethig, D., Köditz, H., Dennhardt, N., Beerbaum, P., & Bertram, H. (2016). Feasibility and Accuracy of Cardiac Right-to-Left-Shunt Detection in Children by New Transpulmonary Ultrasound Dilution Method. Pediatric Cardiology, 38(1), 135–148. https://doi.org/10.1007/s00246-016-1494-4
  7. Linden, K., Ladage, D., Dewald, O., Gatzweiler, E., Pieper, A., Seehase, M., Duerr, G. D., Breuer, J., & Herberg, U. (2016). Comparison of stroke volumes assessed by three-dimensional echocardiography and transpulmonary thermodilution in a pediatric animal model. Journal of Clinical Monitoring and Computing, 31(2), 353–360. https://doi.org/10.1007/s10877-016-9843-7
  8. Vrancken, S. L., van Heijst, A. F., Hopman, J. C., Liem, K. D., van der Hoeven, J. G., & de Boode, W. P. (2016). Detection and quantification of left-to-right shunting using transpulmonary ultrasound dilution (TPUD): a validation study in neonatal lambs. Journal of Perinatal Medicine, 44(8), 925–932. https://doi.org/10.1515/jpm-2015-0310
  9. Heringlake, M., Paarmann, H., Heinze, H., Groesdonk, H.-V., & Brandt, S. (2015). Hämodynamisches und respiratorisches Monitoring. In Die Intensivmedizin (pp. 1–57). Springer Berlin Heidelberg. https://doi.org/10.1007/978-3-642-54675-4_21-1
  10. Tibby, S. M. (2014). Hemodynamic Monitoring. In Pediatric Critical Care Medicine (pp. 543–567). Springer London. https://doi.org/10.1007/978-1-4471-6362-6_40
  11. Heringlake, M., Paarmann, H., Heinze, H., Groesdonk, H.-V., & Brandt, S. (2014). Hämodynamisches und respiratorisches Monitoring. In Die Intensivmedizin (pp. 173–206). Springer Berlin Heidelberg. https://doi.org/10.1007/978-3-642-54953-3_17
  12. Vrancken, S. L., van Heijst, A. F., Hopman, J. C., Liem, K. D., van der Hoeven, J. G., & de Boode, W. P. (2014). Hemodynamic volumetry using transpulmonary ultrasound dilution (TPUD) technology in a neonatal animal model. Journal of Clinical Monitoring and Computing, 29(5), 643–652. https://doi.org/10.1007/s10877-014-9647-6
  13. Boehne, M., Baustert, M., Paetzel, V., Köditz, H., Schoof, S., Happel, C. M., & Bertram, H. (2014). Determination of cardiac output by ultrasound dilution technique in infants and children: a validation study against direct Fick principle. British Journal of Anaesthesia, 112(3), 469–476. https://doi.org/10.1093/bja/aet382