Renal Blood Flow Using Arterial Spin Labeling (ASL) MRI: Experimental Protocol and Principles

Description

Abstract A noninvasive, robust, and reproducible method to measure renal perfusion is important to understand the physiology of kidney. Arterial spin labeling (ASL) MRI technique labels the endogenous blood water as freely diffusible tracers to measure perfusion quantitatively without relying on exogenous contrast agent. Therefore, it alleviates the safety concern involving gadolinium chelates. To obtain quantitative tissue perfusion information is particularly relevant for multisite and longitudinal imaging of living subjects. This chapter is based upon work from the PARENCHIMA COST Action, a community-driven network funded by the European Cooperation in Science and Technology (COST) program of the European Union, which aims to improve the reproducibility and standardization of renal MRI biomarkers. This experimental protocol chapter is complemented by two separate chapters describing the basic concept and data analysis.

Additional details

Dates

Issued
2021

References

  1. Williams, D. S., Detre, J. A., Leigh, J. S., & Koretsky, A. P. (1992). Magnetic resonance imaging of perfusion using spin inversion of arterial water. Proceedings of the National Academy of Sciences, 89(1), 212–216. https://doi.org/10.1073/pnas.89.1.212
  2. Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992). Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation. Proceedings of the National Academy of Sciences, 89(12), 5675–5679. https://doi.org/10.1073/pnas.89.12.5675
  3. Kim, S. (1995). Quantification of relative cerebral blood flow change by flow‐sensitive alternating inversion recovery (FAIR) technique: Application to functional mapping. Magnetic Resonance in Medicine, 34(3), 293–301. https://doi.org/10.1002/mrm.1910340303
  4. Hueper, K., Gutberlet, M., Rong, S., Hartung, D., Mengel, M., Lu, X., Haller, H., Wacker, F., Meier, M., & Gueler, F. (2014). Acute Kidney Injury: Arterial Spin Labeling to Monitor Renal Perfusion Impairment in Mice—Comparison with Histopathologic Results and Renal Function. Radiology, 270(1), 117–124. https://doi.org/10.1148/radiol.13130367
  5. Rajendran, R., Lew, S. K., Yong, C. X., Tan, J., Wang, D. J. J., & Chuang, K. (2013). Quantitative mouse renal perfusion using arterial spin labeling. NMR in Biomedicine, 26(10), 1225–1232. https://doi.org/10.1002/nbm.2939
  6. Pell, G. S., Thomas, D. L., Lythgoe, M. F., Calamante, F., Howseman, A. M., Gadian, D. G., & Ordidge, R. J. (1999). Implementation of quantitative FAIR perfusion imaging with a short repetition time in time-course studies. Magnetic Resonance in Medicine, 41(4), 829–840. https://doi.org/10.1002/(sici)1522-2594(199904)41:4%3C829::aid-mrm24%3E3.0.co;2-u
  7. Rane, S. D., & Gore, J. C. (2013). Measurement of T1 of human arterial and venous blood at 7T. Magnetic Resonance Imaging, 31(3), 477–479. https://doi.org/10.1016/j.mri.2012.08.008
  8. Hueper, K., Schmidbauer, M., Thorenz, A., Bräsen, J. H., Gutberlet, M., Mengel, M., Hartung, D., Chen, R., Meier, M., Haller, H., Wacker, F., Rong, S., & Gueler, F. (2017). Longitudinal evaluation of perfusion changes in acute and chronic renal allograft rejection using arterial spin labeling in translational mouse models. Journal of Magnetic Resonance Imaging, 46(6), 1664–1672. https://doi.org/10.1002/jmri.25713
  9. Tewes, S., Gueler, F., Chen, R., Gutberlet, M., Jang, M.-S., Meier, M., Mengel, M., Hartung, D., Wacker, F., Rong, S., Hueper, K., & Long, D. (2017). Functional MRI for characterization of renal perfusion impairment and edema formation due to acute kidney injury in different mouse strains. PLOS ONE, 12(3), e0173248. https://doi.org/10.1371/journal.pone.0173248