Published April 1982 | Journal article | Version v1 | https://doi.org/10.1016/s0003-4975(10)63235-3

Malfunction of a St. Jude Medical Heart Valve in Mitral Position

Additional details

Dates

Issued
April 1982

References

  1. Lillehei CW: Worldwide results with the St. Jude cardiac prosthesis. In Abstracts of the St. Jude Medical, Inc., First European Symposium, Paris, France, June 21, 1980, pp 49–71
  2. Curcio, C. A., Commerford, P. J., Rose, A. G., Stevens, J. E., & Barnard, M. S. (1981). Calcification of glutaraldehyde-preserved porcine xenografts in young patients. The Journal of Thoracic and Cardiovascular Surgery, 81(4), 621–625. https://doi.org/10.1016/s0022-5223(19)39497-8
  3. Geha, A. S., Laks, H., Stansel, H. C., Fredrick Cornhill, J., Kilman, J. W., Buckley, M. J., & Roberts, W. C. (1979). Late failure of porcine valve heterografts in children. The Journal of Thoracic and Cardiovascular Surgery, 78(3), 351–364. https://doi.org/10.1016/s0022-5223(19)38101-2
  4. Lewis, B. S., Bakst, A., Rod, J. L., Rein, A., Gotsman, M. S., & Appelbaum, A. (1980). Early Calcification and Obstruction of a Mitral Porcine Bioprosthesis. The Annals of Thoracic Surgery, 30(6), 592–594. https://doi.org/10.1016/s0003-4975(10)61738-9
  5. Oyer, P. E., Craig Miller, D., Stinson, E. B., Reitz, B. A., Moreno-Cabral, R. J., & Shumway, N. E. (1980). Clinical durability of the Hancock porcine bioprosthetic valve. The Journal of Thoracic and Cardiovascular Surgery, 80(6), 824–833. https://doi.org/10.1016/s0022-5223(19)37688-3
  6. Silver, M. M., Pollock, J., Silver, M. D., Williams, W. G., & Trusler, G. A. (1980). Calcification in porcine xenograft valves in children. The American Journal of Cardiology, 45(3), 685–689. https://doi.org/10.1016/s0002-9149(80)80022-1
  7. Thandroyen, F. T., Whitton, I. N., Pirie, D., Rogers, M. A., & Mitha, A. S. (1980). Severe calcification of glutaraldehyde-preserved porcine xenografts in children. The American Journal of Cardiology, 45(3), 690–696. https://doi.org/10.1016/s0002-9149(80)80023-3
  8. Brodie, B. R., Grossman, W., McLaurin, L., Starek, P. J., & Craige, E. (1976). Diagnosis of prosthetic mitral valve malfunction with combined echo-phonocardiography. Circulation, 53(1), 93–100. https://doi.org/10.1161/01.cir.53.1.93
  9. Chaux, A., Gray, R. J., Matloff, J. M., Feldman, H., & Sustaita, H. (1981). An appreciation of the new St. Jude valvular prosthesis. The Journal of Thoracic and Cardiovascular Surgery, 81(2), 202–211. https://doi.org/10.1016/s0022-5223(19)37627-5
  10. Noninvasive evaluation of the St. Jude valve in the mitral position
  11. Rainer WG: Discussion of Chaux et al [11]

Citations

  1. Butany, J., & Schoen, F. J. (2022). Cardiac valve replacement and related interventions. In Cardiovascular Pathology (pp. 707–760). Elsevier. https://doi.org/10.1016/b978-0-12-822224-9.00010-4
  2. Schoen, F. J., & Butany, J. (2016). Cardiac Valve Replacement and Related Interventions. In Cardiovascular Pathology (pp. 529–576). Elsevier. https://doi.org/10.1016/b978-0-12-420219-1.00013-6
  3. Wernly, J. A., & Crawford, M. H. (1998). CHOOSING A PROSTHETIC HEART VALVE. Cardiology Clinics, 16(3), 491–504. https://doi.org/10.1016/s0733-8651(05)70028-x
  4. Debétaz, L.-F., Ruchat, P., Hurni, M., Fischer, A., Stumpe, F., Sadeghi, H., van Melle, G., & Goy, J.-J. (1997). St. Jude medical valve prosthesis: An analysis of long-term outcome and prognostic factors. The Journal of Thoracic and Cardiovascular Surgery, 113(1), 134–148. https://doi.org/10.1016/s0022-5223(97)70409-4
  5. https://doi.org/10.1177/021849239600400408
  6. Schoen, F. J., Levy, R. J., & Piehler, H. R. (1992). Pathological considerations in replacement cardiac valves. Cardiovascular Pathology, 1(1), 29–52. https://doi.org/10.1016/1054-8807(92)90006-a
  7. Wernly, J. A., & Crawford, M. H. (1991). Choosing A Prosthetic Heart Valve. Cardiology Clinics, 9(2), 329–338. https://doi.org/10.1016/s0733-8651(18)30305-9
  8. Rose, A. G. (1987). Cageless, Central-flow, Low-profile, Tilting-disc Valves. In Pathology of Heart Valve Replacement (pp. 81–111). Springer Netherlands. https://doi.org/10.1007/978-94-009-3227-2_6
  9. https://doi.org/10.1111/j.1540-8191.1987.tb00174.x
  10. https://doi.org/10.3109/14017438609105910
  11. Schoen, F. J. (1985). Pathology of Cardiac Valve Replacement. In Guide to Prosthetic Cardiac Valves (pp. 209–238). Springer New York. https://doi.org/10.1007/978-1-4612-5096-8_8
  12. Hjelms, E. (1985). Escape of a Leaflet from a ST. JUDE MEDICAL® Prosthesis in the Mitral Position. In Cardiac Valve Replacement (pp. 285–289). Springer US. https://doi.org/10.1007/978-1-4613-2601-4_33
  13. https://doi.org/10.3109/14017438509102814
  14. Ross, E. M., & Roberts, W. C. (1984). A precaution when using the St. Jude Medical prosthesis in the aortic valve position. The American Journal of Cardiology, 54(1), 231–233. https://doi.org/10.1016/0002-9149(84)90336-9
  15. Pass, H. I., Sade, R. M., Crawford, F. A., & Hohn, A. R. (1984). Cardiac valve prostheses in children without anticoagulation. The Journal of Thoracic and Cardiovascular Surgery, 87(6), 832–835. https://doi.org/10.1016/s0022-5223(19)38409-0
  16. Yoganathan, A. P., Chaux, A., Gray, R. J., Woo, Y.-R., DeRobertis, M., Williams, F. P., & Matloff, J. M. (1984). Bileaflet, tilting disc and porcine aortic valve substitutes: In vitro hydrodynamic characteristics. Journal of the American College of Cardiology, 3(2), 313–320. https://doi.org/10.1016/s0735-1097(84)80014-5