Anterior mitral leaflet laceration using the MitraCut technique for transapical transcatheter Tendyne implantation after unsuccessful Carillon indirect annuloplasty: a case report
Authors/Creators
Contributors
Description
Abstract Background The introduction of a transapical transcatheter beating heart replacement system has significantly expanded therapeutic options for patients with severely diseased mitral valves, particularly those ineligibles for traditional surgery or transcatheter repair. However, challenges, such as left ventricular outflow tract obstruction (LVOT-O) and the risk of dynamic systolic anterior motion (SAM) in cases with elongated anterior mitral leaflet (AML) post-prosthesis implantation, impede the widespread adoption of transcatheter mitral valve replacement (TMVR). Case summary In 2022, a 75-year-old male with severe mixed-genesis mitral regurgitation (MR) underwent Carillon Mitral Contour System annuloplasty. Recurrent heart failure admissions (New York Heart Association IV) and prohibitive risk for open-heart surgery (European System for Cardiac Operative Risk Evaluation II 8.27%) prompted evaluation for Tendyne TMVR with the MitraCut technique. This beating heart transapical approach involved scissor-mediated splitting of the elongated 27 mm AML, essential for mitigating LVOT-O risk and dynamic SAM. The screening echocardiogram revealed the poorly tethered AML near the thickened septum at the simulated neo-LVOT site. Discussion This case underscores the intricate management challenges associated with severe MR, highlighting the successful application of the MitraCut technique as a viable alternative in high-risk scenarios. The imperative for further research and clinical studies is emphasized to comprehensively elucidate outcomes and safety parameters, providing valuable insights for refining TMVR applications within this context.
Additional details
Identifiers
Funding
Dates
- Issued
-
January 31, 2024
References
- Alperi, A., Granada, J. F., Bernier, M., Dagenais, F., & Rodés-Cabau, J. (2021). Current Status and Future Prospects of Transcatheter Mitral Valve Replacement. Journal of the American College of Cardiology, 77(24), 3058–3078. https://doi.org/10.1016/j.jacc.2021.04.051
- Charitos, E. I., Busch, N., Renker, M., Liakopoulos, O. J., Fischer-Rasokat, U., Colli, A., Hamm, C. W., Choi, Y.-H., & Kim, W.-K. (2023). Direct, Transapical, Scissors-Mediated LAMPOON. JACC: Cardiovascular Interventions, 16(8), 991–992. https://doi.org/10.1016/j.jcin.2022.12.014
- Prevention and treatment of left ventricular outflow tract obstruction after transcatheter mitral valve replacement
- Andreas, M., Kerbel, T., Chaplygin, A., Simon, P., Bartunek, A., & Mach, M. (2023). Novel technique to prevent outflow tract obstruction in transapical transcatheter mitral valve replacement: The MitraCut technique. JTCVS Techniques, 18, 53–56. https://doi.org/10.1016/j.xjtc.2023.01.019
- Mach, M., Kerbel, T., Poschner, T., Bartunek, A., Sauer, J., Laufer, G., & Andreas, M. (2022). Mitral Leaflet Cutting Before Transcatheter Mitral Valve Replacement. JACC: Cardiovascular Interventions, 15(20), 2107–2108. https://doi.org/10.1016/j.jcin.2022.08.035
- Russo, G., Gennari, M., Gavazzoni, M., Pedicino, D., Pozzoli, A., Taramasso, M., & Maisano, F. (2021). Transcatheter Mitral Valve Implantation: Current Status and Future Perspectives. Circulation: Cardiovascular Interventions, 14(9). https://doi.org/10.1161/circinterventions.121.010628
- Babaliaros, V. C., Greenbaum, A. B., Khan, J. M., Rogers, T., Wang, D. D., Eng, M. H., O’Neill, W. W., Paone, G., Thourani, V. H., Lerakis, S., Kim, D. W., Chen, M. Y., & Lederman, R. J. (2017). Intentional Percutaneous Laceration of the Anterior Mitral Leaflet to Prevent Outflow Obstruction During Transcatheter Mitral Valve Replacement. JACC: Cardiovascular Interventions, 10(8), 798–809. https://doi.org/10.1016/j.jcin.2017.01.035
- Transcatheter valve-in-valve implantation in a degenerated mitral bioprosthesis using a trans-septal anterograde approach and 3-D transesophageal echocardiography guidance
- Rudzinski, P. N., Leipsic, J. A., Schoepf, U. J., Dudek, D., Schwarz, F., Andreas, M., Zlahoda-Huzior, A., Thilo, C., Renker, M., Burt, J. R., Emrich, T., Varga-Szemes, A., Amoroso, N. S., Steinberg, D. H., Pukacki, P., Demkow, M., Kepka, C., & Bayer, R. R. (2022). CT in Transcatheter-delivered Treatment of Valvular Heart Disease. Radiology, 304(1), 4–17. https://doi.org/10.1148/radiol.210567
- Reid, A., Ben Zekry, S., Turaga, M., Tarazi, S., Bax, J. J., Wang, D. D., Piazza, N., Bapat, V. N., Ihdayhid, A. R., Cavalcante, J. L., Blanke, P., & Leipsic, J. (2021). Neo-LVOT and Transcatheter Mitral Valve Replacement. JACC: Cardiovascular Imaging, 14(4), 854–866. https://doi.org/10.1016/j.jcmg.2020.09.027
- Regueiro, A., Granada, J. F., Dagenais, F., & Rodés-Cabau, J. (2017). Transcatheter Mitral Valve Replacement. Journal of the American College of Cardiology, 69(17), 2175–2192. https://doi.org/10.1016/j.jacc.2017.02.045
- Bapat, V., Rajagopal, V., Meduri, C., Farivar, R. S., Walton, A., Duffy, S. J., Gooley, R., Almeida, A., Reardon, M. J., Kleiman, N. S., Spargias, K., Pattakos, S., Ng, M. K., Wilson, M., Adams, D. H., Leon, M., Mack, M. J., Chenoweth, S., Sorajja, P., … Redwood, S. (2018). Early Experience With New Transcatheter Mitral Valve Replacement. Journal of the American College of Cardiology, 71(1), 12–21. https://doi.org/10.1016/j.jacc.2017.10.061
- Urena, M., Vahanian, A., & Søndergaard, L. (2018). Patient selection for transcatheter mitral valve implantation: why is it so hard to find patients?. EuroIntervention, 14(AB), AB83–AB90. https://doi.org/10.4244/eij-d-18-00510
- Yoon, S.-H., Whisenant, B. K., Bleiziffer, S., Delgado, V., Dhoble, A., Schofer, N., Eschenbach, L., Bansal, E., Murdoch, D. J., Ancona, M., Schmidt, T., Yzeiraj, E., Vincent, F., Niikura, H., Kim, W.-K., Asami, M., Unbehaun, A., Hirji, S., Fujita, B., … Makkar, R. R. (2018). Outcomes of transcatheter mitral valve replacement for degenerated bioprostheses, failed annuloplasty rings, and mitral annular calcification. European Heart Journal, 40(5), 441–451. https://doi.org/10.1093/eurheartj/ehy590
- Ludwig, S., Kalbacher, D., Waldschmidt, L., Schaefer, A., Modine, T., Dvir, D., Carasso, S., Denti, P., Schofer, N., & Conradi, L. (2023). Prevention of LVOT Obstruction by Device-Mediated Laceration of the Anterior Mitral Valve Leaflet During TMVR. JACC: Case Reports, 16, 101873. https://doi.org/10.1016/j.jaccas.2023.101873
Citations
- Azzola Guicciardi, N., Ascione, G., Russo, G., Onishi, T., Swaminathan, S., Granada, J. F., Freeman, P., Tang, G. H. L., & Denti, P. (2026). Left ventricular outflow tract obstruction in transcatheter mitral interventions: percutaneous anterior leaflet modification. European Heart Journal. https://doi.org/10.1093/eurheartj/ehag837
- Andreas, M., Kerbel, T., Mach, M., Zierer, A., Kuhn, E., Sauer, J. S., Ruge, H., Reguiero, A., & Colli, A. (2024). Prevention of left ventricular outflow tract obstruction in transapical mitral valve replacement: the MitraCut procedure. EuroIntervention, 20(22), 1419–1429. https://doi.org/10.4244/eij-d-24-00490