Deep Learning–Based Distortion Correction for Brain Diffusion-weighted Imaging
Authors/Creators
Description
Background: Single-shot echo-planar imaging DWI (ss-EPI DWI) is susceptible to geometric distortions near air–tissue interfaces, limiting diagnostic accuracy. Multishot readout-segmented DWI (RESOLVE DWI) mitigates these artifacts but requires longer acquisition times. This study evaluated whether ss-EPI DWI with a deep learning–enabled correction of static field inhomogeneities (DL DWI) can achieve effective distortion correction while preserving diagnostic reliability and reducing scan time. Objectives: To compare image quality, geometric distortion, lesion detectability, and diagnostic confidence of ss-EPI DWI with DL-enabled correction of static field inhomogeneities (DL DWI) against conventional ss-EPI DWI (without correction) and RESOLVE DWI. Materials and Methods: In this prospective single-center study (April 2025 to August 2025), 100 patients undergoing clinically indicated brain MRI were enrolled following written informed consent. All patients underwent DL ss-EPI DWI with DL correction (1 min 29 s) and RESOLVE DWI (3 min 17 s); ss-EPI DWI was reconstructed by disabling DL correction for all patients. Qualitative and quantitative analyses were performed. Three board-certified radiologists rated image quality, lesion detectability, distortion, and diagnostic confidence on a 5-point Likert Scale. Two quantitative measures of distortion were applied: geometric conformity with anatomic 3D T1-weighted data through coregistration methods and gray-value distributions within volumes of interest in susceptibility-affected regions (temporal lobe, cerebellum, and brainstem). Results: DL DWI significantly outperformed ss-EPI DWI across all qualitative parameters, including diagnostic confidence (median, 4.0 vs. 3.0; P < 0.001), overall image quality (median, 4.0 vs. 3.0; P < 0.001), and geometric distortion (median, 4.0 vs. 3.0; P < 0.001). RESOLVE DWI achieved the highest ratings overall (median, 5.0). Lesion detectability was comparable between DL DWI and RESOLVE DWI (median, 4.0 for both; P > 0.08), while both significantly outperformed ss-EPI DWI ( P < 0.001). Quantitative analysis confirmed superior geometric accuracy of DL DWI over ss-EPI DWI, with lower coregistration cost-function values and normalization of gray-value distributions in susceptibility-affected regions. Conclusion: DL DWI improved image quality and geometric accuracy compared with uncorrected ss-EPI DWI. Subjective lesion-detectability ratings were similar between DL DWI and RESOLVE DWI, while DL DWI required less than half the acquisition time. These findings support DL-based distortion correction as a promising, time-efficient approach for brain diffusion-weighted imaging that warrants confirmation in a predefined noninferiority design.
Additional details
Identifiers
- OpenAlex
- W7212005892
- PMID
- 42712163
- URL
- https://www.ovid.com/10.1097/RLI.0000000000001311
Dates
- Issued
-
September 9, 2026
References
- Baliyan, V., Das, C. J., Sharma, R., & Gupta, A. K. (2016). Diffusion weighted imaging: Technique and applications. World Journal of Radiology, 8(9), 785. https://doi.org/10.4329/wjr.v8.i9.785
- Drake-Pérez, M., Boto, J., Fitsiori, A., Lovblad, K., & Vargas, M. I. (2018). Clinical applications of diffusion weighted imaging in neuroradiology. Insights into Imaging, 9(4), 535–547. https://doi.org/10.1007/s13244-018-0624-3
- Gaddamanugu, S., Shafaat, O., Sotoudeh, H., Sarrami, A. H., Rezaei, A., Saadatpour, Z., & Singhal, A. (2021). Clinical applications of diffusion-weighted sequence in brain imaging: beyond stroke. Neuroradiology, 64(1), 15–30. https://doi.org/10.1007/s00234-021-02819-3
- Mustafa, W. F., Abbas, M., & Elsorougy, L. (2020). Role of diffusion-weighted imaging in differentiation between posterior fossa brain tumors. The Egyptian Journal of Neurology, Psychiatry and Neurosurgery, 56(1). https://doi.org/10.1186/s41983-019-0145-0
- Department of Radiology, Z. U. and H. K. P., Farhan, N., Khan, S., Department of Neurology, Z. U. and H. K. P., Rasheed, B., Dow Institute of Radiology, D. U. of H. S. K. P., Naz, N., Dow Institute of Radiology, D. U. of H. S. K. P., Rahim, A., Dow Institute of Radiology, D. U. of H. S. K. P., Nasir, A., Department of Pharmacology, Z. U. and H. K. P., Hammad, M., & Riphah International University, I. P. (2025). Role of diffusion-weighted imaging in diagnosing acute ischemic stroke and its limitations in stroke mimics. Romanian Journal of Neurology, 24(2), 160–166. https://doi.org/10.37897/rjn.2025.2.4
- Unveiling opportunities for intervention: a prospective cohort study investigating the clinical significance of diffusion-weighted imaging (DWI)-fluid-attenuated inversion recovery (FLAIR) mismatch beyond the window period in acute ischemic stroke
- Xiong, Y., Li, G., Dai, E., Wang, Y., Zhang, Z., & Guo, H. (2019). Distortion correction for high‐resolution single‐shot EPI DTI using a modified field‐mapping method. NMR in Biomedicine, 32(9). https://doi.org/10.1002/nbm.4124
- Yang, J. Y.-M., Chen, J., Alexander, B., Schilling, K., Kean, M., Wray, A., Seal, M., Maixner, W., & Beare, R. (2022). Assessment of intraoperative diffusion EPI distortion and its impact on estimation of supratentorial white matter tract positions in pediatric epilepsy surgery. NeuroImage: Clinical, 35, 103097. https://doi.org/10.1016/j.nicl.2022.103097
- Thian, Y. L., Xie, W., Porter, D. A., & Weileng Ang, B. (2014). Readout-segmented Echo-planar Imaging for Diffusion-weighted Imaging in the Pelvis at 3T—A Feasibility Study. Academic Radiology, 21(4), 531–537. https://doi.org/10.1016/j.acra.2014.01.005
- Tullos, H., Dale, B., Bidwell, G., Perkins, E., Raucher, D., Khan, M., & James, J. (2012). SU‐E‐I‐67: Multi‐Shot RESOLVE Compared to Single‐Shot EPI Diffusion‐ Weighted MR Imaging Acquisition Scheme. Medical Physics, 39(6Part5), 3640–3640. https://doi.org/10.1118/1.4734783
- Altmann, S., Grauhan, N. F., Mercado, M. A. A., Steinmetz, S., Kronfeld, A., Paul, R., Benkert, T., Uphaus, T., Groppa, S., Winter, Y., Brockmann, M. A., & Othman, A. E. (2024). Deep Learning Accelerated Brain Diffusion-Weighted MRI with Super Resolution Processing. Academic Radiology, 31(10), 4171–4182. https://doi.org/10.1016/j.acra.2024.02.049
- Hanamatsu, S., Murayama, K., Ohno, Y., Yamamoto, K., Yui, M., & Toyama, H. (2023). Deep learning reconstruction for brain diffusion-weighted imaging: efficacy for image quality improvement, apparent diffusion coefficient assessment, and intravoxel incoherent motion evaluation in <i>in vitro</i> and <i>in vivo</i> studies. Diagnostic and Interventional Radiology, 29(5), 664–673. https://doi.org/10.4274/dir.2023.232149
- Liu, Y., Yu, Y., Ouyang, J., Jiang, B., Yang, G., Ostmeier, S., Wintermark, M., Michel, P., Liebeskind, D. S., Lansberg, M. G., Albers, G. W., & Zaharchuk, G. (2023). Functional Outcome Prediction in Acute Ischemic Stroke Using a Fused Imaging and Clinical Deep Learning Model. Stroke, 54(9), 2316–2327. https://doi.org/10.1161/strokeaha.123.044072
- Liao, P., Zhang, J., Zeng, K., Yang, Y., Cai, S., Guo, G., & Cai, C. (2018). Referenceless distortion correction of gradient-echo echo-planar imaging under inhomogeneous magnetic fields based on a deep convolutional neural network. Computers in Biology and Medicine, 100, 230–238. https://doi.org/10.1016/j.compbiomed.2018.07.010
- Hu, Z., Wang, Y., Zhang, Z., Zhang, J., Zhang, H., Guo, C., Sun, Y., & Guo, H. (2020). Distortion correction of single-shot EPI enabled by deep-learning. NeuroImage, 221, 117170. https://doi.org/10.1016/j.neuroimage.2020.117170
- Simultaneous super-resolution and distortion correction for single-shot EPI DWI using deep learning
- Porter, D. A., & Heidemann, R. M. (2009). High resolution diffusion‐weighted imaging using readout‐segmented echo‐planar imaging, parallel imaging and a two‐dimensional navigator‐based reacquisition. Magnetic Resonance in Medicine, 62(2), 468–475. https://doi.org/10.1002/mrm.22024
- Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002). Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magnetic Resonance in Medicine, 47(6), 1202–1210. https://doi.org/10.1002/mrm.10171
- Setsompop, K., Gagoski, B. A., Polimeni, J. R., Witzel, T., Wedeen, V. J., & Wald, L. L. (2011). Blipped‐controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g ‐factor penalty. Magnetic Resonance in Medicine, 67(5), 1210–1224. https://doi.org/10.1002/mrm.23097
- Talagala, S. L., Sarlls, J. E., Liu, S., & Inati, S. J. (2015). Improvement of temporal signal‐to‐noise ratio of GRAPPA accelerated echo planar imaging using a FLASH based calibration scan. Magnetic Resonance in Medicine, 75(6), 2362–2371. https://doi.org/10.1002/mrm.25846
- Hou, Q., Lu, C.-Z., Cheng, M.-M., & Feng, J. (2024). Conv2Former: A Simple Transformer-Style ConvNet for Visual Recognition. IEEE Transactions on Pattern Analysis and Machine Intelligence, 46(12), 8274–8283. https://doi.org/10.1109/tpami.2024.3401450
- Andersson, J. L. R., Skare, S., & Ashburner, J. (2003). How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging. NeuroImage, 20(2), 870–888. https://doi.org/10.1016/s1053-8119(03)00336-7
- Tong, A., Lemberskiy, G., Huang, C., Shanbhogue, K., Feiweier, T., & Rosenkrantz, A. B. (2019). Exploratory study of geometric distortion correction of prostate diffusion‐weighted imaging using B0 map acquisition. Journal of Magnetic Resonance Imaging, 50(5), 1614–1619. https://doi.org/10.1002/jmri.26751
- Landis, J. R., & Koch, G. G. (1977). The Measurement of Observer Agreement for Categorical Data. Biometrics, 33(1), 159. https://doi.org/10.2307/2529310
- Wilpert, C., Russe, M. F., Weiss, J., Voss, C., Rau, S., Strecker, R., Reisert, M., Bedin, R., Urbach, H., Zaitsev, M., Bamberg, F., & Rau, A. (2025). Deep Learning Reconstruction Combined With Conventional Acceleration Improves Image Quality of 3 T Brain MRI and Does Not Impact Quantitative Diffusion Metrics. Investigative Radiology, 60(8), 526–534. https://doi.org/10.1097/rli.0000000000001158
1–25 of 41