Published July 30, 2020 | Journal article | Version v1 | https://doi.org/10.3390/s20154251

An Approach towards Motion-Tolerant PPG-Based Algorithm for Real-Time Heart Rate Monitoring of Moving Pigs

Description

Animal welfare remains a very important issue in the livestock sector, but monitoring animal welfare in an objective and continuous way remains a serious challenge. Monitoring animal welfare, based upon physiological measurements instead of the audio–visual scoring of behaviour, would be a step forward. One of the obvious physiological signals related to welfare and stress is heart rate. The objective of this research was to measure heart rate (beat per minutes) in pigs with technology that soon will be affordable. Affordable heart rate monitoring is done today at large scale on humans using the Photo Plethysmography (PPG) technology. We used PPG sensors on a pig′s body to test whether it allows the retrieval of a reliable heart rate signal. A continuous wavelet transform (CWT)-based algorithm is developed to decouple the cardiac pulse waves from the pig. Three different wavelets, namely second, fourth and sixth order Derivative of Gaussian (DOG), are tested. We show the results of the developed PPG-based algorithm, against electrocardiograms (ECG) as a reference measure for heart rate, and this for an anaesthetised versus a non-anaesthetised animal. We tested three different anatomical body positions (ear, leg and tail) and give results for each body position of the sensor. In summary, it can be concluded that the agreement between the PPG-based heart rate technique and the reference sensor is between 91% and 95%. In this paper, we showed the potential of using the PPG-based technology to assess the pig′s heart rate.

Additional details

Related works

Is new version of
10.20944/preprints202007.0652.v1 (DOI)

Dates

Issued
July 30, 2020

References

  1. Kovács, L., Jurkovich, V., Bakony, M., Szenci, O., Póti, P., & Tőzsér, J. (2014). Welfare implication of measuring heart rate and heart rate variability in dairy cattle: literature review and conclusions for future research. Animal, 8(2), 316–330. https://doi.org/10.1017/s1751731113002140
  2. Hopster, H., & Blokhuis, H. J. (1994). Validation of a heart-rate monitor for measuring a stress response in dairy cows. Canadian Journal of Animal Science, 74(3), 465–474. https://doi.org/10.4141/cjas94-066
  3. von Holst, D. (1998). The Concept of Stress and Its Relevance for Animal Behavior. In Advances in the Study of Behavior (pp. 1–131). Elsevier. https://doi.org/10.1016/s0065-3454(08)60362-9
  4. Ivanov, K. P. (2006). The development of the concepts of homeothermy and thermoregulation. Journal of Thermal Biology, 31(1-2), 24–29. https://doi.org/10.1016/j.jtherbio.2005.12.005
  5. Whittow, G. C., & Tazawa, H. (1991). The Early Development of Thermoregulation in Birds. Physiological Zoology, 64(6), 1371–1390. https://doi.org/10.1086/physzool.64.6.30158220
  6. Youssef, A., Exadaktylos, V., & Berckmans, D. (2014). Modelling and quantification of the thermoregulatory responses of the developing avian embryo: Electrical analogies of a physiological system. Journal of Thermal Biology, 44, 14–19. https://doi.org/10.1016/j.jtherbio.2014.05.006
  7. Nie, L., Berckmans, D., Wang, C., & Li, B. (2020). Is Continuous Heart Rate Monitoring of Livestock a Dream or Is It Realistic? A Review. Sensors, 20(8), 2291. https://doi.org/10.3390/s20082291
  8. von Borell, E., Langbein, J., Després, G., Hansen, S., Leterrier, C., Marchant, J., Marchant-Forde, R., Minero, M., Mohr, E., Prunier, A., Valance, D., & Veissier, I. (2007). Heart rate variability as a measure of autonomic regulation of cardiac activity for assessing stress and welfare in farm animals — A review. Physiology & Behavior, 92(3), 293–316. https://doi.org/10.1016/j.physbeh.2007.01.007
  9. Elgendi, M. (2016). Optimal Signal Quality Index for Photoplethysmogram Signals. Bioengineering, 3(4), 21. https://doi.org/10.3390/bioengineering3040021
  10. Youssef, A., Viazzi, S., Exadaktylos, V., and Berckmans, D. (2013, January 10–12). Semi-invasive, non-contact measurements of chicken embryo heart rate using video imaging and signal processing. Proceedings of the 6th European Conference on Precision Livestock Farming, Leuven, Belgium.
  11. Lee, Y., Han, H., and Kim, J. (2008, January 14–17). Influence of motion artifacts on photoplethysmographic signals for measuring pulse rates. Proceedings of the 2008 International Conference on Control, Automation and Systems, Seoul, Korea.
  12. Jang, D.-G., Kwon, U. K., Yoon, S. K., Park, C., Ku, Y., Noh, S. W., & Kim, Y. H. (2018). A Simple and Robust Method for Determining the Quality of Cardiovascular Signals Using the Signal Similarity. 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 478–481. https://doi.org/10.1109/embc.2018.8512341
  13. Sabeti, E., Reamaroon, N., Mathis, M., Gryak, J., Sjoding, M., & Najarian, K. (2019). Signal quality measure for pulsatile physiological signals using morphological features: Applications in reliability measure for pulse oximetry. Informatics in Medicine Unlocked, 16, Article 100222. https://doi.org/10.1016/j.imu.2019.100222
  14. Tang, S. K. D., Goh, Y. Y. S., Wong, M. L. D., & Lew, Y. L. E. (2016). PPG signal reconstruction using a combination of discrete wavelet transform and empirical mode decomposition. 2016 6th International Conference on Intelligent and Advanced Systems (ICIAS), 1–4. https://doi.org/10.1109/icias.2016.7824118
  15. Elgendi, M., Liang, Y., & Ward, R. (2018). Toward Generating More Diagnostic Features from Photoplethysmogram Waveforms. Diseases, 6(1), 20. https://doi.org/10.3390/diseases6010020
  16. Daubechies, I. (1990). The wavelet transform, time-frequency localization and signal analysis. IEEE Transactions on Information Theory, 36(5), 961–1005. https://doi.org/10.1109/18.57199
  17. Torrence, C., & Compo, G. P. (1998). A Practical Guide to Wavelet Analysis. Bulletin of the American Meteorological Society, 79(1), 61–78. https://doi.org/10.1175/1520-0477(1998)079%3C0061:apgtwa%3E2.0.co;2
  18. The Use of Continuous Wavelet Transform Based on the Fast Fourier Transform in the Analysis of Multi-channel Electrogastrography Recordings
  19. Montejo, L. A., & Suarez, L. E. (2013). An improved CWT-based algorithm for the generation of spectrum-compatible records. International Journal of Advanced Structural Engineering, 5(1). https://doi.org/10.1186/2008-6695-5-26
  20. Li, L.-. chuan . (2010). A New Method of Wavelet Transform Based on FFT for Signal Processing. 2010 Second WRI Global Congress on Intelligent Systems, 203–206. https://doi.org/10.1109/gcis.2010.22
  21. Sahambi, J. S., Tandon, S. N., & Bhatt, R. K. P. (1997). Using wavelet transforms for ECG characterization. An on-line digital signal processing system. IEEE Engineering in Medicine and Biology Magazine, 16(1), 77–83. https://doi.org/10.1109/51.566158
  22. Colquhoun, D. A., Forkin, K. T., Durieux, M. E., & Thiele, R. H. (2012). Ability of the Masimo pulse CO-Oximeter to detect changes in hemoglobin. Journal of Clinical Monitoring and Computing, 26(2), 69–73. https://doi.org/10.1007/s10877-012-9335-3
  23. The effects of motion artifact and low perfusion on the performance of a new generation of pulse oximeters in volunteers undergoing hypoxemia
  24. Cannesson, M., Delannoy, B., Morand, A., Rosamel, P., Attof, Y., Bastien, O., & Lehot, J.-J. (2008). Does the Pleth Variability Index Indicate the Respiratory-Induced Variation in the Plethysmogram and Arterial Pressure Waveforms?. Anesthesia & Analgesia, 106(4), 1189–1194. https://doi.org/10.1213/ane.0b013e318167ab1f
  25. Krishnan, R., Natarajan, B., & Warren, S. (2010). Two-Stage Approach for Detection and Reduction of Motion Artifacts in Photoplethysmographic Data. IEEE Transactions on Biomedical Engineering, 57(8), 1867–1876. https://doi.org/10.1109/tbme.2009.2039568

1–25 of 27

Citations

  1. Youssef, A., Sun, C., & Norton, T. (2026). An expert-informed synthetic animal data generator : A physiology-consistent generative framework for high-fidelity animal digital twins. Smart Agricultural Technology, 14, 102285. https://doi.org/10.1016/j.atech.2026.102285
  2. Song, D., Zou, F., Wang, L., & Wang, H. (2026). Applications and prospects of photoplethysmography technology in animal husbandry: A comprehensive review. Computers and Electronics in Agriculture, 240, Article 111164. https://doi.org/10.1016/j.compag.2025.111164
  3. Yin, M., Zhao, Q., Yan, W., Chen, K., Hu, J., & Zhang, M. (2026). Advanced multi-sensor-based wearable electronic system with interpretable supervised model for stress response recognition of Hu sheep. Computers and Electronics in Agriculture, 243, 111399. https://doi.org/10.1016/j.compag.2025.111399
  4. https://doi.org/10.1080/01652176.2026.2739038
  5. Yin, M., Ma, R., Huang, W., Chi, F., Zhao, Q., & Zhang, M. (2025). High-performance flexible wearable electronics for sheep physiological information wireless sensing and health assessment. Computers and Electronics in Agriculture, 231, Article 109917. https://doi.org/10.1016/j.compag.2025.109917
  6. Miller, M., Byfield, R., Crosby, M., Schiltz, P., Johnson, P. J., & Lin, J. (2023). A wearable photoplethysmography sensor for non-invasive equine heart rate monitoring. Smart Agricultural Technology, 5, 100264. https://doi.org/10.1016/j.atech.2023.100264
  7. https://doi.org/10.1109/enbeng58165.2023.10175338
  8. https://doi.org/10.3389/fanim.2023.1103812
  9. https://doi.org/10.35848/1347-4065/acc8df
  10. https://doi.org/10.1145/3565995.3566037
  11. https://doi.org/10.1155/2022/1870094
  12. https://doi.org/10.3389/fanim.2022.1046557
  13. Byrne, C., & Logas, J. (2021, October 8). The Future of Technology and Computers in Veterinary Medicine. In Diagnostics and Therapy in Veterinary Dermatology (1st ed., pp. 245–250). Wiley. https://doi.org/10.1002/9781119680642.ch26