Standardization in clinical enzymology: a challenge for the theory of metrological traceability
Description
Abstract The goal of standardization for measurement of the catalytic concentration of enzymes is to achieve comparable results in human samples, independent of the reagent kits, instruments, and laboratory where the assay is performed. To pursue this objective, the IFCC has established reference systems for the most important clinical enzymes. These systems are based on the following requirements: a) reference methods, well described and evaluated extensively; b) suitable reference materials; and c) reference laboratories operating in a highly controlled manner. When these reference systems are used appropriately, the diagnostic industry can assign traceable values to commercial calibrators. Clinical laboratories that use procedures with validated calibrators to measure human specimens can now obtain values that are traceable to higher-order reference procedures. These reference systems constitute the structure of the traceability chain to which the routine methods can be linked via an appropriate calibration process, provided that they have a comparable specificity (i.e., they are measuring the same catalytic quantity). Clin Chem Lab Med 2010;48:301–7.
Additional details
Identifiers
Dates
- Issued
-
February 1, 2010
References
- Forsmark, C. E., & Baillie, J. (2007). AGA Institute Technical Review on Acute Pancreatitis. Gastroenterology, 132(5), 2022–2044. https://doi.org/10.1053/j.gastro.2007.03.065
- Kim, W. R., Flamm, S. L., Di Bisceglie, A. M., & Bodenheimer, H. C. (2008). Serum activity of alanine aminotransferase (ALT) as an indicator of health and disease†. Hepatology, 47(4), 1363–1370. https://doi.org/10.1002/hep.22109
- Schmidt, E. S., & Schmidt, F. W. (1988). Standardization by reference methods: a German viewpoint. Clinica Chimica Acta, 173(1), 9–17. https://doi.org/10.1016/0009-8981(88)90352-x
- Panteghini, M., Ceriotti, F., Schumann, G., & Siekmann, L. (2001). Establishing a Reference System in Clinical Enzymology. Clinical Chemistry and Laboratory Medicine, 39(9). https://doi.org/10.1515/cclm.2001.131
- Panteghini, M. (2009). Traceability as a unique tool to improve standardization in laboratory medicine. Clinical Biochemistry, 42(4-5), 236–240. https://doi.org/10.1016/j.clinbiochem.2008.09.098
- Vesper, H. W., & Thienpont, L. M. (2009). Traceability in Laboratory Medicine. Clinical Chemistry, 55(6), 1067–1075. https://doi.org/10.1373/clinchem.2008.107052
- Thienpont, L. M., Van Uytfanghe, K., & De Leenheer, A. P. (2002). Reference measurement systems in clinical chemistry. Clinica Chimica Acta, 323(1-2), 73–87. https://doi.org/10.1016/s0009-8981(02)00188-2
- Schumann, G., Bonora, R., Ceriotti, F., Clerc-Renaud, P., Ferrero, C. A., Férard, G., Franck, P. F. H., Gella, F.-J., Hoelzel, W., Jørgensen, P. J., Kanno, T., Kessner, A., Klauke, R., Kristiansen, N., Lessinger, J.-M., Linsinger, T. P. J., Misaki, H., & Panteghini, M. (2002). IFCC Primary Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes at 37°C. Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase. Clinical Chemistry and Laboratory Medicine, 40(6). https://doi.org/10.1515/cclm.2002.110
- Schumann, G., Bonora, R., Ceriotti, F., Clerc-Renaud, P., Ferrero, C. A., Férard, G., Franck, P. F. H., Gella, F.-J., Hoelzel, W., Jørgensen, P. J., Kanno, T., Kessner, A., Klauke, R., Kristiansen, N., Lessinger, J.-M., Linsinger, T. P. J., Misaki, H., & Panteghini, M. (2002). IFCC Primary Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes at 37°C. Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase. Clinical Chemistry and Laboratory Medicine, 40(6). https://doi.org/10.1515/cclm.2002.111
- Schumann, G., Bonora, R., Ceriotti, F., Férard, G., Ferrero, C. A., Franck, P. F. H., Gella, F.-J., Hoelzel, W., Jørgensen, P. J., Kanno, T., Kessner, A., Klauke, R., Kristiansen, N., Lessinger, J.-M., Linsinger, T. P. J., Misaki, H., Panteghini, M., Pauwels, J., Schiele, F., & Schimmel, H. G. (2002). IFCC Primary Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes at 37°C. Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine Aminotransferase. Clinical Chemistry and Laboratory Medicine, 40(7). https://doi.org/10.1515/cclm.2002.124
- Schumann, G., Bonora, R., Ceriotti, F., Férard, G., Ferrero, C. A., Franck, P. F. H., Gella, F.-J., Hoelzel, W., Jørgensen, P. J., Kanno, T., Kessner, A., Klauke, R., Kristiansen, N., Lessinger, J.-M., Linsinger, T. P. J., Misaki, H., Panteghini, M., Pauwels, J., Schiele, F., & Schimmel, H. G. (2002). IFCC Primary Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes at 37°C. Part 5. Reference Procedure for the Measurement of Catalytic Concentration of Aspartate Aminotransferase. Clinical Chemistry and Laboratory Medicine, 40(7). https://doi.org/10.1515/cclm.2002.125
- Schumann, G., Bonora, R., Ceriotti, F., Férard, G., Ferrero, C. A., Franck, P. F. H., Gella, F.-J., Hoelzel, W., Jørgensen, P. J., Kanno, T., Kessner, A., Klauke, R., Kristiansen, N., Lessinger, J.-M., Linsinger, T. P. J., Misaki, H., Panteghini, M., Pauwels, J., Schiele, F., & Schimmel, H. G. (2002). IFCC Primary Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes at 37C. Part 6. Reference Procedure for the Measurement of Catalytic Concentration of γ-Glutamyltransferase. Clinical Chemistry and Laboratory Medicine, 40(7). https://doi.org/10.1515/cclm.2002.126
- Schumann, G., Aoki, R., Ferrero, C. A., Ehlers, G., Férard, G., Gella, F.-J., Jørgensen, P. J., Kanno, T., Kessner, A., Klauke, R., Kytzia, H.-J., Lessinger, J.-M., Miller, W. G., Nagel, R., Pauwels, J., Schimmel, H., Siekmann, L., Weidemann, G., Yoshida, K., & Ceriotti, F. (2006). IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37°C: International Federation of Clinical Chemistry and Laboratory Medicine (IFCC): Scientific Division, Committee on Reference Systems for Enzymes (C-RSE): Part 8. Reference procedure for the measurement of catalytic concentration of α-amylase: [α-Amylase: 1,4-α-D-glucan 4-glucanohydrolase (AMY), EC 3.2.1.1]. Clinical Chemistry and Laboratory Medicine (CCLM), 44(9). https://doi.org/10.1515/cclm.2006.212
- Siekmann, L., Bonora, R., Burtis, C. A., Ceriotti, F., Clerc-Renaud, P., Férard, G., Ferrero, C. A., Forest, J.-C., Franck, P. F. H., Gella, F.-J., Hoelzel, W., Jørgensen, P. J., Kanno, T., Kessner, A., Klauke, R., Kristiansen, N., Lessinger, J.-M., Linsinger, T. P. J., & Misaki, H. (2002). IFCC Primary Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes at 37°C. Part 7. Certification of Four Reference Materials for the Determination of Enzymatic Activity of γ-Glutamyltransferase, Lactate Dehydrogenase, Alanine Aminotransferase and Creatine Kinase according to IFCC Reference Procedures at 37°C. Clinical Chemistry and Laboratory Medicine, 40(7). https://doi.org/10.1515/cclm.2002.127
- Scharnhorst, V., Apperloo, J., Baadenhuijsen, H., & Vader, H. L. (2004). Multicenter evaluation of the commutability of a potential reference material for harmonization of enzyme activities. Clinical Chemistry and Laboratory Medicine (CCLM), 42(12). https://doi.org/10.1515/cclm.2004.261
- Ceriotti, F., Hinzmann, R., & Panteghini, M. (2009). Reference intervals: the way forward. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine, 46(1), 8–17. https://doi.org/10.1258/acb.2008.008170
- Schumann, G., & Klauke, R. (2003). New IFCC reference procedures for the determination of catalytic activity concentrations of five enzymes in serum: preliminary upper reference limits obtained in hospitalized subjects. Clinica Chimica Acta, 327(1-2), 69–79. https://doi.org/10.1016/s0009-8981(02)00341-8
- Steinmetz, J., Schiele, F., Gueguen, R., Férard, G., & Henny, J. (2007). Standardization of γ-glutamyltransferase assays by intermethod calibration. Effect on determining common reference limits. Clinical Chemical Laboratory Medicine, 45(10). https://doi.org/10.1515/cclm.2007.290
- Pagani, F., Bonora, R., & Panteghini, M. (2003). Reference Interval for Lactate Dehydrogenase Catalytic Activity in Serum Measured According to the New IFCC Recommendations. Clinical Chemistry and Laboratory Medicine, 41(7). https://doi.org/10.1515/cclm.2003.148
- Heiduk, M., Päge, I., Kliem, C., Abicht, K., & Klein, G. (2009). Pediatric reference intervals determined in ambulatory and hospitalized children and juveniles. Clinica Chimica Acta, 406(1-2), 156–161. https://doi.org/10.1016/j.cca.2009.06.021
- Cattozzo, G., Guerra, E., Ceriotti, F., Franzini, C., & (SIBioC), . the E. W. G. of . the I. S. of C. B. and C. M. B. (2008). Commutable Calibrator with Value Assigned by the IFCC Reference Procedure to Harmonize Serum Lactate Dehydrogenase Activity Results Measured by 2 Different Methods. Clinical Chemistry, 54(8), 1349–1355. https://doi.org/10.1373/clinchem.2007.100081
- Jansen, R., Schumann, G., Baadenhuijsen, H., Franck, P., Franzini, C., Kruse, R., Kuypers, A., Weykamp, C., & Panteghini, M. (2006). Trueness verification and traceability assessment of results from commercial systems for measurement of six enzyme activities in serum. Clinica Chimica Acta, 368(1-2), 160–167. https://doi.org/10.1016/j.cca.2005.12.033
- Fraser, C. G., Petersen, P. H., Libeer, J.-C., & Ricos, C. (1997). Proposals for Setting Generally Applicable Quality Goals Solely Based on Biology. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine, 34(1), 8–12. https://doi.org/10.1177/000456329703400103
Citations
- Staaden, A., Canalias, F., Ceriotti, F., Infusino, I., Veuger, M., Weber, F., & Grote-Koska, D. (2026). IFCC primary reference procedure for the measurement of catalytic activity concentrations of enzymes at 37 °C. Part 10: Reference procedure for the measurement of catalytic concentration of pancreatic α-amylase. Clinica Chimica Acta, 579, Article 120657. https://doi.org/10.1016/j.cca.2025.120657
- https://doi.org/10.1080/10408363.2024.2434562
- https://doi.org/10.1515/cclm-2025-0550
- https://doi.org/10.1111/apt.17914
- https://doi.org/10.1111/apt.17951
- https://doi.org/10.1111/apt.18112
- https://doi.org/10.1515/cclm-2023-0553
- https://doi.org/10.1515/cclm-2023-0900
- Makris, K., Mousa, C., & Cavalier, E. (2022). Alkaline Phosphatases: Biochemistry, Functions, and Measurement. Calcified Tissue International, 112(2), 233–242. https://doi.org/10.1007/s00223-022-01048-x
- Litwack, G. (2022). Enzymes. In Human Biochemistry (pp. 109–146). Elsevier. https://doi.org/10.1016/b978-0-323-85718-5.00006-6
- https://doi.org/10.1515/cclm-2022-1257
- Valenti, L., Pelusi, S., Bianco, C., Ceriotti, F., Berzuini, A., Iogna Prat, L., Trotti, R., Malvestiti, F., D’Ambrosio, R., Lampertico, P., Colli, A., Colombo, M., Tsochatzis, E. A., Fraquelli, M., & Prati, D. (2021). Definition of Healthy Ranges for Alanine Aminotransferase Levels: A 2021 Update. Hepatology Communications, 5(11), 1824–1832. https://doi.org/10.1002/hep4.1794
- https://doi.org/10.1210/clinem/dgab328
- https://doi.org/10.1515/cclm-2019-1336
- https://doi.org/10.1515/cclm-2020-0015
- Litwack, G. (2018). Enzymes. In Human Biochemistry (pp. 95–129). Elsevier. https://doi.org/10.1016/b978-0-12-383864-3.00005-3
- Braga, F., Pasqualetti, S., & Panteghini, M. (2018). The role of external quality assessment in the verification of in vitro medical diagnostics in the traceability era. Clinical Biochemistry, 57, 23–28. https://doi.org/10.1016/j.clinbiochem.2018.02.004
- https://doi.org/10.1080/00365513.2017.1413715
- https://doi.org/10.1515/cclm-2016-0605
- https://doi.org/10.1515/cclm-2016-0661
- https://doi.org/10.1515/cclm-2017-1007
- Cerelli, M. J., Grimm, K., Duan, X., Mulberg, E., Jalilie, M., Sekella, P., Payes, M., Cox, H., Blick, K. E., Fang, K. C., & Zychlinsky, E. (2016). Evaluation of recombinant enzyme calibration to harmonize lipoprotein-associated phospholipase A2 activity results between instruments. Clinical Biochemistry, 49(6), 480–485. https://doi.org/10.1016/j.clinbiochem.2015.11.018
- https://doi.org/10.1097/ftd.0000000000000269
- https://doi.org/10.1515/cclm-2015-0803
- https://doi.org/10.1515/cclm-2015-0869
1–25 of 38