Projector‐based augmented reality system for interventional visualization inside MRI scanners
Authors/Creators
Contributors
Editor:
Description
AbstractBackgroundNavigation support in interventional magnetic resonance imaging (MRI) is separated from the operating field, which makes it difficult to interpret positions and orientations and to coordinate the necessary hand movements.MethodsWe developed a projector‐based augmented reality system to enable visual navigation of tracked instruments on pre‐planned paths and visualization of risk structures directly on the patient inside the MRI bore. To assess the accuracy of the system, a user study was carried out with clinicians in a needle navigation test scenario.ResultsThe targets were reached with an error of 1.7 ± 0.5 mm and the entry points with an error of 1.7 ± 0.8 mm.ConclusionThe accuracy results are similar to those reached by live image–guided interventions and related work and confirm that this projective augmented reality prototype for the interventional MRI can serve as a platform for current and future research in augmented reality visualization and dynamic registration.
Additional details
Identifiers
- OpenAlex
- W2888778109
- PMID
- 30168639
- URL
- https://onlinelibrary.wiley.com/doi/10.1002/rcs.1950
Funding
Dates
- Issued
-
September 4, 2018
References
- Buell, J. F., Thomas, M. T., Rudich, S., Marvin, M., Nagubandi, R., Ravindra, K. V., Brock, G., & McMasters, K. M. (2008). Experience With More Than 500 Minimally Invasive Hepatic Procedures. Annals of Surgery, 248(3), 475–486. https://doi.org/10.1097/sla.0b013e318185e647
- Schullian, P., Widmann, G., Lang, T. B., Knoflach, M., & Bale, R. (2011). Accuracy and diagnostic yield of CT-guided stereotactic liver biopsy of primary and secondary liver tumors. Computer Aided Surgery, 16(4), 181–187. https://doi.org/10.3109/10929088.2011.578367
- MR‐guided freehand biopsy of liver lesions with fast continuous imaging using a 1.0‐T open MRI scanner: experience in 50 patients
- Kariniemi, J., Blanco Sequeiros, R., Ojala, R., & Tervonen, O. (2004). MRI-guided abdominal biopsy in a 0.23-T open-configuration MRI system. European Radiology, 15(6), 1256–1262. https://doi.org/10.1007/s00330-004-2566-z
- Rempp, H., Loh, H., Hoffmann, R., Rothgang, E., Pan, L., Claussen, C. D., & Clasen, S. (2013). Liver lesion conspicuity during real‐time MR‐guided radiofrequency applicator placement using spoiled gradient echo and balanced steady‐state free precession imaging. Journal of Magnetic Resonance Imaging, 40(2), 432–439. https://doi.org/10.1002/jmri.24371
- Weiss, C. R., Nour, S. G., & Lewin, J. S. (2008). MR‐guided biopsy: A review of current techniques and applications. Journal of Magnetic Resonance Imaging, 27(2), 311–325. https://doi.org/10.1002/jmri.21270
- Hoffmann, R., Thomas, C., Rempp, H., Schmidt, D., Pereira, P. L., Claussen, C. D., & Clasen, S. (2011). Performing MR-guided biopsies in clinical routine: factors that influence accuracy and procedure time. European Radiology, 22(3), 663–671. https://doi.org/10.1007/s00330-011-2297-x
- Bock, M., & Wacker, F. K. (2008). MR‐guided intravascular interventions: Techniques and applications. Journal of Magnetic Resonance Imaging, 27(2), 326–338. https://doi.org/10.1002/jmri.21271
- Hillenbrand, C. M., Elgort, D. R., Wong, E. Y., Reykowski, A., Wacker, F. K., Lewin, J. S., & Duerk, J. L. (2004). Active device tracking and high‐resolution intravascular MRI using a novel catheter‐based, opposed‐solenoid phased array coil. Magnetic Resonance in Medicine, 51(4), 668–675. https://doi.org/10.1002/mrm.20050
- Rothgang, E., Gilson, W. D., Wacker, F., Hornegger, J., Lorenz, C. H., & Weiss, C. R. (2013). Rapid freehand MR‐guided percutaneous needle interventions: An image‐based approach to improve workflow and feasibility. Journal of Magnetic Resonance Imaging, 37(5), 1202–1212. https://doi.org/10.1002/jmri.23894
- Manzey, D., Röttger, S., Bahner‐Heyne, J. E., Schulze‐Kissing, D., Dietz, A., Meixensberger, J., & Strauss, G. (2009). Image‐guided navigation: the surgeon's perspective on performance consequences and human factors issues. The International Journal of Medical Robotics and Computer Assisted Surgery, 5(3), 297–308. https://doi.org/10.1002/rcs.261
- Gavaghan, K., Oliveira-Santos, T., Peterhans, M., Reyes, M., Kim, H., Anderegg, S., & Weber, S. (2011). Evaluation of a portable image overlay projector for the visualisation of surgical navigation data: phantom studies. International Journal of Computer Assisted Radiology and Surgery, 7(4), 547–556. https://doi.org/10.1007/s11548-011-0660-7
- Gering, D. T., Nabavi, A., Kikinis, R., Hata, N., O'Donnell, L. J., Grimson, W. E. L., Jolesz, F. A., Black, P. M., & Wells, W. M. (2001). An integrated visualization system for surgical planning and guidance using image fusion and an open MR. Journal of Magnetic Resonance Imaging, 13(6), 967–975. https://doi.org/10.1002/jmri.1139
- Wacker, F. K., Vogt, S., Khamene, A., Jesberger, J. A., Nour, S. G., Elgort, D. R., Sauer, F., Duerk, J. L., & Lewin, J. S. (2006). An Augmented Reality System for MR Image–guided Needle Biopsy: Initial Results in a Swine Model. Radiology, 238(2), 497–504. https://doi.org/10.1148/radiol.2382041441
- Fichtinger, G., Deguet, A., Masamune, K., Balogh, E., Fischer, G. S., Mathieu, H., Taylor, R. H., Zinreich, S. J., & Fayad, L. M. (2005). Image Overlay Guidance for Needle Insertion in CT Scanner. IEEE Transactions on Biomedical Engineering, 52(8), 1415–1424. https://doi.org/10.1109/tbme.2005.851493
- Weiss, C. R., Marker, D. R., Fischer, G. S., Fichtinger, G., Machado, A. J., & Carrino, J. A. (2011). Augmented Reality Visualization Using Image-Overlay for MR-Guided Interventions: System Description, Feasibility, and Initial Evaluation in a Spine Phantom. American Journal of Roentgenology, 196(3), W305–W307. https://doi.org/10.2214/ajr.10.5038
- U-Thainual, P., Fritz, J., Moonjaita, C., Ungi, T., Flammang, A., Carrino, J. A., Fichtinger, G., & Iordachita, I. (2012). MR image overlay guidance: system evaluation for preclinical use. International Journal of Computer Assisted Radiology and Surgery, 8(3), 365–378. https://doi.org/10.1007/s11548-012-0788-0
- Fritz, J., U-Thainual, P., Ungi, T., Flammang, A. J., Cho, N. B., Fichtinger, G., Iordachita, I. I., & Carrino, J. A. (2012). Augmented Reality Visualization With Image Overlay for MRI-Guided Intervention: Accuracy for Lumbar Spinal Procedures With a 1.5-T MRI System. American Journal of Roentgenology, 198(3), W266–W273. https://doi.org/10.2214/ajr.11.6918
- Gavaghan, K., Oliveira-Santos, T., Peterhans, M., Reyes, M., Kim, H., Anderegg, S., & Weber, S. (2011). Evaluation of a portable image overlay projector for the visualisation of surgical navigation data: phantom studies. International Journal of Computer Assisted Radiology and Surgery, 7(4), 547–556. https://doi.org/10.1007/s11548-011-0660-7
- Gavaghan, K. A., Anderegg, S., Peterhans, M., Oliveira-Santos, T., & Weber, S. (2012). Augmented Reality Image Overlay Projection for Image Guided Open Liver Ablation of Metastatic Liver Cancer. In Lecture Notes in Computer Science (pp. 36–46). Springer Berlin Heidelberg. https://doi.org/10.1007/978-3-642-32630-1_4
- Gavaghan, K. A., Peterhans, M., Oliveira-Santos, T., & Weber, S. (2011). A Portable Image Overlay Projection Device for Computer-Aided Open Liver Surgery. IEEE Transactions on Biomedical Engineering, 58(6), 1855–1864. https://doi.org/10.1109/tbme.2011.2126572
- Sugimoto, M., Yasuda, H., Koda, K., Suzuki, M., Yamazaki, M., Tezuka, T., Kosugi, C., Higuchi, R., Watayo, Y., Yagawa, Y., Uemura, S., Tsuchiya, H., & Azuma, T. (2009). Image overlay navigation by markerless surface registration in gastrointestinal, hepatobiliary and pancreatic surgery. Journal of Hepato-Biliary-Pancreatic Sciences, 17(5), 629–636. https://doi.org/10.1007/s00534-009-0199-y
- Besharati Tabrizi, L., & Mahvash, M. (2015). Augmented reality–guided neurosurgery: accuracy and intraoperative application of an image projection technique. Journal of Neurosurgery, 123(1), 206–211. https://doi.org/10.3171/2014.9.jns141001
- Moreno, D., & Taubin, G. (2012). Simple, Accurate, and Robust Projector-Camera Calibration. 2012 Second International Conference on 3D Imaging, Modeling, Processing, Visualization & Transmission, 464–471. https://doi.org/10.1109/3dimpvt.2012.77
- Garrido-Jurado, S., Muñoz-Salinas, R., Madrid-Cuevas, F. J., & Marín-Jiménez, M. J. (2014). Automatic generation and detection of highly reliable fiducial markers under occlusion. Pattern Recognition, 47(6), 2280–2292. https://doi.org/10.1016/j.patcog.2014.01.005
1–25 of 36
Citations
- Vyas, S., Gupta, S., & Tyagi, A. (2025). Role of AR/VR/XR/MR in Meta-Health. In Meta-Health (pp. 95–112). Springer Nature Singapore. https://doi.org/10.1007/978-981-96-5844-2_6
- Foroughi, P., Demir, A., Hossbach, M., Rajan, P., Yarmolenko, P., Vellody, R., Cleary, K., & Sharma, K. (2023). In situ guidance for MRI interventions using projected feedback. International Journal of Computer Assisted Radiology and Surgery, 18(6), 1069–1076. https://doi.org/10.1007/s11548-023-02897-z
- Volmer, B., Baumeister, J., Von Itzstein, S., Schlesewsky, M., Bornkessel-Schlesewsky, I., & Thomas, B. H. (2023). Event Related Brain Responses Reveal the Impact of Spatial Augmented Reality Predictive Cues on Mental Effort. IEEE Transactions on Visualization and Computer Graphics, 29(12), 4990–5007. https://doi.org/10.1109/tvcg.2022.3197810
- Volmer, B., Liu, J.-S., Matthews, B., Bornkessel-Schlesewsky, I., Feiner, S., & Thomas, B. H. (2023). Multi-Level Precues for Guiding Tasks Within and Between Workspaces in Spatial Augmented Reality. IEEE Transactions on Visualization and Computer Graphics, 29(11), 4449–4459. https://doi.org/10.1109/tvcg.2023.3320246
- Boulanger, P. (2023). Projected Augmented Reality to Display Medical Information Directly on a Patient's Skin. In Applications of Augmented Reality - Current State of the Art. IntechOpen. https://doi.org/10.5772/intechopen.1002487
- Patil, V., Narayan, J., Sandhu, K., & Dwivedy, S. K. (2022). Integration of Virtual Reality and Augmented Reality in Physical Rehabilitation: A State-of-the-Art Review. In Design Science and Innovation (pp. 177–205). Springer Singapore. https://doi.org/10.1007/978-981-16-9455-4_10
- Burström, G., Persson, O., Edström, E., & Elmi-Terander, A. (2022). Current Status of Augmented Reality in the Spine. In Technical Advances in Minimally Invasive Spine Surgery (pp. 367–392). Springer Nature Singapore. https://doi.org/10.1007/978-981-19-0175-1_33
- Bhatla, S., & Tripathi, V. (2022). Augmented reality: The emerging technology in medical field. AIP Conference Proceedings, 2767, 020009. https://doi.org/10.1063/5.0106014
- Mbonye, V., & Ebrahim, R. (2022). Integrating Augmented Reality in Science Education in South Africa: Applications in the Mancosa iTEACHlab. 2022 International Conference on Artificial Intelligence, Big Data, Computing and Data Communication Systems (icABCD), 1–5. https://doi.org/10.1109/icabcd54961.2022.9856083
- Velazco‐Garcia, J. D., Navkar, N. V., Balakrishnan, S., Younes, G., Abi‐Nahed, J., Al‐Rumaihi, K., Darweesh, A., Elakkad, M. S. M., Al‐Ansari, A., Christoforou, E. G., Karkoub, M., Leiss, E. L., Tsiamyrtzis, P., & Tsekos, N. V. (2021). Evaluation of how users interface with holographic augmented reality surgical scenes: Interactive planning MR‐Guided prostate biopsies. The International Journal of Medical Robotics and Computer Assisted Surgery, 17(5). https://doi.org/10.1002/rcs.2290
- Sveinsson, B., Koonjoo, N., & Rosen, M. S. (2021). ARmedViewer, an augmented-reality-based fast 3D reslicer for medical image data on mobile devices: A feasibility study. Computer Methods and Programs in Biomedicine, 200, 105836. https://doi.org/10.1016/j.cmpb.2020.105836
- REICH, C. M., SATTLER, B., JOCHIMSEN, T. H., UNGER, M., MELZER, L., LANDGRAF, L., BARTHEL, H., SABRI, O., & MELZER, A. (2021). Practical setting and potential applications of interventions guided by PET/MRI. The Quarterly Journal of Nuclear Medicine and Molecular Imaging, 65(1). https://doi.org/10.23736/s1824-4785.20.03293-8
- Li, J. T. S., Ng, E. E. N., & Lee, V. W. Y. (2021). Student's Perspectives on Augmented Reality in Pharmacy Education in Hong Kong. Frontiers in Education, 6. https://doi.org/10.3389/feduc.2021.756907
- Franson, D., Dupuis, A., Gulani, V., Griswold, M., & Seiberlich, N. (2021). A System for Real-Time, Online Mixed-Reality Visualization of Cardiac Magnetic Resonance Images. Journal of Imaging, 7(12), 274. https://doi.org/10.3390/jimaging7120274
- Mamone, V., Ferrari, V., Condino, S., & Cutolo, F. (2020). Projected Augmented Reality to Drive Osteotomy Surgery: Implementation and Comparison With Video See-Through Technology. IEEE Access, 8, 169024–169035. https://doi.org/10.1109/access.2020.3021940
- Mamone, V., Fonzo, M. D., Esposito, N., Ferrari, M., & Ferrari, V. (2020). Monitoring Wound Healing With Contactless Measurements and Augmented Reality. IEEE Journal of Translational Engineering in Health and Medicine, 8, 1–12. https://doi.org/10.1109/jtehm.2020.2983156
- Heinrich, F., Schwenderling, L., Joeres, F., Lawonn, K., & Hansen, C. (2020). Comparison of Augmented Reality Display Techniques to Support Medical Needle Insertion. IEEE Transactions on Visualization and Computer Graphics, 26(12), 3568–3575. https://doi.org/10.1109/tvcg.2020.3023637
- Kang, C., Kim, M., & Lee, S. (2019). Color refinement using deep neural networks for enhancing color recognition in a projector‐camera system. Journal of the Society for Information Display, 27(12), 795–805. https://doi.org/10.1002/jsid.826
- Koca, B. A., Cubukcu, B., & Yuzgec, U. (2019). Augmented Reality Application for Preschool Children with Unity 3D Platform. 2019 3rd International Symposium on Multidisciplinary Studies and Innovative Technologies (ISMSIT), 1–4. https://doi.org/10.1109/ismsit.2019.8932729
- Heinrich, F., Joeres, F., Lawonn, K., & Hansen, C. (2019). Comparison of Projective Augmented Reality Concepts to Support Medical Needle Insertion. IEEE Transactions on Visualization and Computer Graphics, 25(6), 2157–2167. https://doi.org/10.1109/tvcg.2019.2903942
- Krause, Q., & McCrory, B. (2019). Integration of Currently Available and Emerging Intracorporeal Imaging Technologies in Medicine. Proceedings of the Human Factors and Ergonomics Society Annual Meeting, 63(1), 1692–1696. https://doi.org/10.1177/1071181319631064
- Mewes, A., Heinrich, F., Hensen, B., Wacker, F., Lawonn, K., & Hansen, C. (2018). Concepts for augmented reality visualisation to support needle guidance inside the MRI. Healthcare Technology Letters, 5(5), 172–176. https://doi.org/10.1049/htl.2018.5076