Published August 31, 2023 | Journal article | Version v1 | https://doi.org/10.3390/metabo13090986

Quality Control in Targeted GC-MS for Amino Acid-OMICS

Description

Gas chromatography-mass spectrometry (GC-MS) is suitable for the analysis of non-polar analytes. Free amino acids (AA) are polar, zwitterionic, non-volatile and thermally labile analytes. Chemical derivatization of AA is indispensable for their measurement by GC-MS. Specific conversion of AA to their unlabeled methyl esters (d0Me) using 2 M HCl in methanol (CH3OH) is a suitable derivatization procedure (60 min, 80 °C). Performance of this reaction in 2 M HCl in tetradeutero-methanol (CD3OD) generates deuterated methyl esters (d3Me) of AA, which can be used as internal standards in GC-MS. d0Me-AA and d3Me-AA require subsequent conversion to their pentafluoropropionyl (PFP) derivatives for GC-MS analysis using pentafluoropropionic anhydride (PFPA) in ethyl acetate (30 min, 65 °C). d0Me-AA-PFP and d3Me-AA-PFP derivatives of AA are readily extractable into water-immiscible, GC-compatible organic solvents such as toluene. d0Me-AA-PFP and d3Me-AA-PFP derivatives are stable in toluene extracts for several weeks, thus enabling high throughput quantitative measurement of biological AA by GC-MS using in situ prepared d3Me-AA as internal standards in OMICS format. Here, we describe the development of a novel OMICS-compatible QC system and demonstrate its utility for the quality control of quantitative analysis of 21 free AA and metabolites in human plasma samples by GC-MS as Me-PFP derivatives. The QC system involves cross-standardization of the concentrations of the AA in their aqueous solutions at four concentration levels and a quantitative control of AA at the same four concentration levels in pooled human plasma samples. The retention time (tR)-based isotope effects (IE) and the difference (δ(H/D) of the retention times of the d0Me-AA-PFP derivatives (tR(H)) and the d3Me-AA-PFP derivatives (tR(D)) were determined in study human plasma samples of a nutritional study (n = 353) and in co-processed QC human plasma samples (n = 64). In total, more than 400 plasma samples were measured in eight runs in seven working days performed by a single person. The proposed QC system provides information about the quantitative performance of the GC-MS analysis of AA in human plasma. IE, δ(H/D) and a massive drop of the peak area values of the d3Me-AA-PFP derivatives may be suitable as additional parameters of qualitative analysis in targeted GC-MS amino acid-OMICS.

Additional details

Dates

Issued
August 31, 2023

References

  1. Hušek, P., & Macek, K. (1975). Gas chromatography of amino acids. Journal of Chromatography A, 113(2), 139–230. https://doi.org/10.1016/s0021-9673(00)86962-9
  2. Hušek, P., Švagera, Z., Hanzlíková, D., Řimnáčová, L., Zahradníčková, H., Opekarová, I., & Šimek, P. (2016). Profiling of urinary amino-carboxylic metabolites by in-situ heptafluorobutyl chloroformate mediated sample preparation and gas chromatography–mass spectrometry. Journal of Chromatography A, 1443, 211–232. https://doi.org/10.1016/j.chroma.2016.03.019
  3. Ferré, S., González-Ruiz, V., Guillarme, D., & Rudaz, S. (2019). Analytical strategies for the determination of amino acids: Past, present and future trends. Journal of Chromatography B, 1132, Article 121819. https://doi.org/10.1016/j.jchromb.2019.121819
  4. Xu, W., Zhong, C., Zou, C., Wang, B., & Zhang, N. (2020). Analytical methods for amino acid determination in organisms. Amino Acids, 52(8), 1071–1088. https://doi.org/10.1007/s00726-020-02884-7
  5. Tsikas, D. (2009). De novo synthesis of trideuteromethyl esters of amino acids for use in GC–MS and GC-tandem MS exemplified for ADMA in human plasma and urine: Standardization, validation, comparison and proof of evidence for their aptitude as internal standards. Journal of Chromatography B, 877(23), 2308–2320. https://doi.org/10.1016/j.jchromb.2009.01.005
  6. Hanff, E., Ruben, S., Kreuzer, M., Bollenbach, A., Kayacelebi, A. A., Das, A. M., von Versen-Höynck, F., von Kaisenberg, C., Haffner, D., Ückert, S., & Tsikas, D. (2019). Development and validation of GC–MS methods for the comprehensive analysis of amino acids in plasma and urine and applications to the HELLP syndrome and pediatric kidney transplantation: evidence of altered methylation, transamidination, and arginase activity. Amino Acids, 51(3), 529–547. https://doi.org/10.1007/s00726-018-02688-w
  7. Baskal, S., Bollenbach, A., & Tsikas, D. (2021). Two-Step Derivatization of Amino Acids for Stable-Isotope Dilution GC–MS Analysis: Long-Term Stability of Methyl Ester-Pentafluoropropionic Derivatives in Toluene Extracts. Molecules, 26(6), 1726. https://doi.org/10.3390/molecules26061726
  8. Zhao, L., Ni, Y., Su, M., Li, H., Dong, F., Chen, W., Wei, R., Zhang, L., Guiraud, S. P., Martin, F.-P., Rajani, C., Xie, G., & Jia, W. (2017). High Throughput and Quantitative Measurement of Microbial Metabolome by Gas Chromatography/Mass Spectrometry Using Automated Alkyl Chloroformate Derivatization. Analytical Chemistry, 89(10), 5565–5577. https://doi.org/10.1021/acs.analchem.7b00660
  9. Theodoridis, G., Gika, H. G., & Wilson, I. D. (2011). Mass spectrometry‐based holistic analytical approaches for metabolite profiling in systems biology studies. Mass Spectrometry Reviews, 30(5), 884–906. https://doi.org/10.1002/mas.20306
  10. Gika, H. G., Theodoridis, G. A., Earll, M., & Wilson, I. D. (2012). A Qc Approach to The Determination of Day-To-Day Reproducibility And Robustness of Lc–Ms Methods For Global Metabolite Profiling in Metabonomics/Metabolomics. Bioanalysis, 4(18), 2239–2247. https://doi.org/10.4155/bio.12.212
  11. Gika, H. G., Wilson, I. D., & Theodoridis, G. A. (2014). LC–MS-based holistic metabolic profiling. Problems, limitations, advantages, and future perspectives. Journal of Chromatography B, 966, 1–6. https://doi.org/10.1016/j.jchromb.2014.01.054
  12. Gika, H. G., Zisi, C., Theodoridis, G., & Wilson, I. D. (2016). Protocol for quality control in metabolic profiling of biological fluids by U(H)PLC-MS. Journal of Chromatography B, 1008, 15–25. https://doi.org/10.1016/j.jchromb.2015.10.045
  13. Begou, O., Gika, H. G., Theodoridis, G. A., & Wilson, I. D. (2018). Quality Control and Validation Issues in LC-MS Metabolomics. In Methods in Molecular Biology (pp. 15–26). Springer New York. https://doi.org/10.1007/978-1-4939-7643-0_2
  14. Lynch, K. L. (2018). Accreditation and Quality Assurance for Clinical Liquid Chromatography–Mass Spectrometry Laboratories. Clinics in Laboratory Medicine, 38(3), 515–526. https://doi.org/10.1016/j.cll.2018.05.002
  15. Lippa, K. A., Aristizabal-Henao, J. J., Beger, R. D., Bowden, J. A., Broeckling, C., Beecher, C., Clay Davis, W., Dunn, W. B., Flores, R., Goodacre, R., Gouveia, G. J., Harms, A. C., Hartung, T., Jones, C. M., Lewis, M. R., Ntai, I., Percy, A. J., Raftery, D., Schock, T. B., … Ubhi, B. K. (2022). Reference materials for MS-based untargeted metabolomics and lipidomics: a review by the metabolomics quality assurance and quality control consortium (mQACC). Metabolomics, 18(4), Article 24. https://doi.org/10.1007/s11306-021-01848-6
  16. Kirwan, J. A., Gika, H., Beger, R. D., Bearden, D., Dunn, W. B., Goodacre, R., Theodoridis, G., Witting, M., Yu, L.-R., Wilson, I. D., & (mQACC), . the . metabolomics Q. A. and Q. C. C. (2022). Quality assurance and quality control reporting in untargeted metabolic phenotyping: mQACC recommendations for analytical quality management. Metabolomics, 18(9), Article 70. https://doi.org/10.1007/s11306-022-01926-3
  17. Sens, A., Rischke, S., Hahnefeld, L., Dorochow, E., Schäfer, S. M. G., Thomas, D., Köhm, M., Geisslinger, G., Behrens, F., & Gurke, R. (2023). Pre-analytical sample handling standardization for reliable measurement of metabolites and lipids in LC-MS-based clinical research. Journal of Mass Spectrometry and Advances in the Clinical Lab, 28, 35–46. https://doi.org/10.1016/j.jmsacl.2023.02.002
  18. Tsikas, D. (2005). ReviewMethods of quantitative analysis of the nitric oxide metabolites nitrite and nitrate in human biological fluids. Free Radical Research, 39(8), 797–815. https://doi.org/10.1080/10715760500053651
  19. TSIKAS, D., SCHUBERT, B., GUTZKI, F., SANDMANN, J., & FROLICH, J. (2003). Quantitative determination of circulating and urinary asymmetric dimethylarginine (ADMA) in humans by gas chromatography–tandem mass spectrometry as methyl ester tri(N-pentafluoropropionyl) derivative. Journal of Chromatography B, 798(1), 87–99. https://doi.org/10.1016/j.jchromb.2003.09.001
  20. Begou, O., Drabert, K., Theodoridis, G., & Tsikas, D. (2020). GC-NICI-MS analysis of acetazolamide and other sulfonamide (R-SO2-NH2) drugs as pentafluorobenzyl derivatives [R-SO2-N(PFB)2] and quantification of pharmacological acetazolamide in human urine. Journal of Pharmaceutical Analysis, 10(1), 49–59. https://doi.org/10.1016/j.jpha.2019.11.006
  21. Cheng, W. L., Markus, C., Lim, C. Y., Tan, R. Z., Sethi, S. K., Loh, T. P., & Protocols, . the I. W. G. on M. E. (2022). Calibration Practices in Clinical Mass Spectrometry: Review and Recommendations. Annals of Laboratory Medicine, 43(1), 5–18. https://doi.org/10.3343/alm.2023.43.1.5
  22. Measurement of plasma and urinary amino acids with gas chromatography in healthy subjects. Variations as a function of age and sex
  23. Effect of the age and the sex on plasma concentration of amino acids
  24. Schwedhelm, E., Xanthakis, V., Maas, R., Sullivan, L. M., Schulze, F., Riederer, U., Benndorf, R. A., Böger, R. H., & Vasan, R. S. (2009). Asymmetric Dimethylarginine Reference Intervals Determined with Liquid Chromatography–Tandem Mass Spectrometry: Results from the Framingham Offspring Cohort. Clinical Chemistry, 55(8), 1539–1545. https://doi.org/10.1373/clinchem.2009.124263
  25. Kouchiwa, T., Wada, K., Uchiyama, M., Kasezawa, N., Niisato, M., Murakami, H., Fukuyama, K., & Yokogoshi, H. (2012). Age-related changes in serum amino acids concentrations in healthy individuals. Clinical Chemistry and Laboratory Medicine, 50(5). https://doi.org/10.1515/cclm-2011-0846

1–25 of 31